• Title/Summary/Keyword: multi-refrigerator

Search Result 34, Processing Time 0.033 seconds

Performance characteristics of a multi type refrigerator (R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구)

  • Ahn, Ji-Hoon;Jang, Yong-Hee;Kim, Yong-Chan;Jang, Ui-Young;Park, Yong-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.292-297
    • /
    • 2008
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi function refrigerator which has different purposes in each evaporator. In this study, the performance of a multi type refrigerator system, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator system was tested by varying the number of refrigerator cabinet, refrigerant charge amount, temperature condition. Based on experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type) At the same external load condition, the COP of the multi type refrigerator was $1.22{\sim}1.29$, but the COP of the single type refrigerator was 1.0.

  • PDF

An Experimental Study on the Performance Characteristics of a Multi Type Refrigerator Using R600a (R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구)

  • Ahn, Ji-Hoon;Jang, Yong-Hee;Kim, Yong-Chan;Choi, Won-Seop;Oh, Seung-Whan;Kim, Chang-Nyeun;Lee, Jae-Seung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.222-228
    • /
    • 2009
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi type refrigerator combining these refrigerators to save space and energy consumption. In this study, the performance of a multi type refrigerator, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator was tested by varying the number of refrigerator cabinet, refrigerant charge, and temperature conditions. In addition, the multi type refrigerator with a suction line heat exchanger(SLHX) was tested to improve system performance. Based on the experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type system). Besides, the COP of the single system increased from 1.0 to 1.37, and those of the dual and triple system increased from 1.29 to 1.39, and 1.22 to 1.51, respectively, by applying the SLHX.

Development of Multi-refrigerator Energy-saving Power Converter and the Combined Control System (멀티냉장고용 에너지 절감형 전력변환기 및 통합 제어시스템 개발)

  • Lee, Sang-Taek;Kim, Hee-Jun;Kim, Dae-Kyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.516-522
    • /
    • 2012
  • Recently trends of home appliance has been changed in house and the demand for functional refrigerator has been increased. Power consumption of refrigerator accounts for a large proportion in consumer electronics. Also, compressor accounts for most of the power consumption in refrigerator parts. Therefore, this paper proposes a multi-refrigerator system with single compressor & condenser fan in order to reduce energy. To verify the availability of the proposed multi refrigerant system, integration experiment is carried out.

A Study on the Performance of a Domestic Small Multi Refrigerator According to a Capillary Tube Change (모세관 변경에 따른 가정용 소형 멀티 냉동시스템의 성능에 관한 연구)

  • Kim Sang Uk;Lee Moo Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.763-771
    • /
    • 2005
  • This paper is an experimental study on the performance according to a capillary tube diameter and length in a domestic small multi refrigerator[kimchi refrigerator]. Pressure drop in a capillary tube is predicted by theoretical analysis and experimental method as the reduction of capillary tube diameter from 0.74 to 0.6 mm. The differences between experimental results and analytical results are mainly caused by friction factor in a capillary tube. Because there are no adequate equations used to calculate pressure drop of capillary tube diameter under 1.0mm. The empirical equations necessary for interpretation of capillary tube were derived from capillary tube test results data using curve fitting method. This study shows that the optimized designs of system, which is capillary tube length and refrigerant charge amount, are 2000mm, 83g at the capillary tube diameter 0.6mm and 3000mm, 73g at the capillary tube diameter 0.74mm. And capillary design tools and system matching techniques necessary for development of the kimchi refrigerator were also developed through this study.

Low frequency sound absorption improvement in refrigerator using multi perforated plate (다공판을 활용한 냉장고 저주파 흡음개선)

  • Ho-Jin, Kwon;Hyoung-Jin, Kim;Kyungjun, Song;Tae-hoon, Kim;Junhyo, Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.723-729
    • /
    • 2022
  • In this study, the multi perforated plate is used to reduce the compressor noise in the low frequency band inside the refrigerator machine room. To predict the sound absorption results, the impedance of the sound absorption material is measured. Using the measured impedance results, it is confirmed that the results used for FEM analysis is almost similar to the experimental values. The sound-absorbing structure that can operate in the target frequency band inside the refrigerator machine room is designed by controlling the hole diameter and arrangement in the perforated plate. The effect of reducing noise in the low frequency band is confirmed by applying perforated plate-based sound absorbing structures to the machine room.

Effective Analysis on the Mechanical Behavior of a Refrigerator using Equivalent Material Properties of Multi-layers (다중재질 접합구조의 등가물성을 이용한 효과적 냉장고 구조 변형 분석에 관한 연구)

  • Park, Jeong-Hyun;Lee, Dong-Kyu;Park, Sang-Hu;Park, Ki-Hong;Ha, Byeong-Kuk;Kim, Hyeong-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1228-1235
    • /
    • 2012
  • A refrigerator has many components which are made from diverse materials such as metal, polymer, plastic, and rubber. So, it generally requires much time and efforts to build up an analysis model in finite element analysis. In this work, to reduce the computational time and efforts a simplified modeling method was proposed for the analysis of a refrigerator. Occasionally, a stick-slip noise occurs in a refrigerator due to relative slip between shelf and inner-case. When we solve the problem by a FE analysis, we should model the structures with detail for considering the contact conditions; by this reason, too many efforts are consumed in the conventional analysis method. Through this work, we shows the concept of simplifying approach and a good agreement with the results of a real model analysis. And also, the evaluation of the proposed method and the application of contact analysis using the simplified model are discussed.

Electric Load Signature Analysis for Home Energy Monitoring System

  • Lu-Lulu, Lu-Lulu;Park, Sung-Wook;Wang, Bo-Hyeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.12 no.3
    • /
    • pp.193-197
    • /
    • 2012
  • This paper focuses on identifying which appliance is currently operating by analyzing electrical load signature for home energy monitoring system. The identification framework is comprised of three steps. Firstly, specific appliance features, or signatures, were chosen, which are DC (Duty Cycle), SO (Slope of On-state), VO (Variance of On-state), and ZC (Zero Crossing) by reviewing observations of appliances from 13 houses for 3 days. Five appliances of electrical rice cooker, kimchi-refrigerator, PC, refrigerator, and TV were chosen for the identification with high penetration rate and total operation-time in Korea. Secondly, K-NN and Naive Bayesian classifiers, which are commonly used in many applications, are employed to estimate from which appliance the signatures are obtained. Lastly, one of candidates is selected as final identification result by majority voting. The proposed identification frame showed identification success rate of 94.23%.

The Utilization of Ice at Home in Seoul and Kyunggi-Do Area (서울 및 경기지역 가정에서의 얼음 사용 실태에 관한 연구)

  • 장정옥;이영미
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.7 no.3
    • /
    • pp.355-363
    • /
    • 1997
  • This study was designed to investigate development points for automatic ice maker which met consumer's demand. Basic data about using ices in Korean's dietary life, were collected from Seoul and Kyunggi-do residences and analyzed by SPSS program. The results were as follows; 93.7% of respondents had 3 major domestic brands' refrigerator and 41.4% of them had medium-large capacity(400-519L). 65% of respondents had a refrigerator that was purchased less than five years. 15.5% of respondents had one more refrigerator. Among of them, major refrigerator was located in kitchen(67.7%) and minor was in kitchen(29.8%) and in veranda or multi-purpose room(26.3%). 66.2% of respondents always prepared ices in ice container, and 85% of them used ice only in summer. Boiling water with barley or corn was used as drinking water (45.6%) and boiled or purified tap water was used to make ice (38.6%) commonly. In cooking, ice was used especially in cold soup with cucumber and seaweed(89.9%), ice-tea or ice-coffee(81%), and fruit punch(64%). The next commonly using ice was adding in alcoholic beverage such as whiskey(57.4%), in Koreans traditional drink(Misugaru) (45.2%) and juice. The purpose of using ice was to cool in soft drink (58.6%), to cool in cooking food(19.9%), to eat ice itself(14.0%), and to enjoy more fantastic taste and mood(3.8%). In whiskey, the purpose of using ices was to control alcoholic content (52.9%). There was no significant difference between sex in the purpose of using ice, but there was significant differences between age(p<0.05). Seasonal variations in using ice, there were significant differences according to sex, age, roles in family, amount of preparation of ice, socio-economic level and brand and capacity of refrigerator in respondent's home.

  • PDF

Performance Evaluations of a Residential Small Multi-Refrigeration System Considering the Adiabatic Characteristics (단열 특성을 고려한 가정용 소형 멀티 냉동시스템의 성능에 관한 연구)

  • Lee, Moo-Yeon;Lee, Dong-Yeon;Joo, Young-Ju;Kim, Sang-Uk;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.868-875
    • /
    • 2007
  • In this paper, performance characteristics of a domestic kim-chi refrigerator are predicted by using the theoretical calculation and experimental method. The objective of this study is to find out the best design points of the refrigeration system and to calculate an adiabatic characteristic with variation to outdoor temperatures. The best design points such as refrigerant charge amount and capillary length were experimentally investigated. And the theoretical calculation is conducted as a function of calculation parameters and outdoor temperatures. According to this study results, the best design points of a refrigeration system with 2 rooms are 95 g of a refrigerant charge amount and 3500 / 3500 mm of capillary lengths and the best design points of a refrigeration system with 3 rooms are 100 g of a refrigerant charge amount and 3000/3000/6000mm of capillary lengths. And the power consumptions of both systems are 13.57 and 18.2 kWh/month. The worst part of heat loss is a front side of a domestic kim-chi refrigerator body.

A Study on Performance Characteristics of R134a Variation with a Capillary Tube Diameter and Length in a Domestic Small multi Refrigerator [Kim_Chi Refrigerator] (모세관 내경 축소에 따른 소형멀티 냉동시스템의 성능특성변화)

  • Lee, Moo-Yeon;Choi, Seok-Jae;Kim, Sang-Ok
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1598-1603
    • /
    • 2004
  • This paper is an experimental study on the performance characteristic with a variation of capillary diameter and length. The performance characteristic of a refrigeration system is predicted that it is occurring changes of flow pattern and pressure drop in a capillary tube because of reduction of capillary diameter 0.74 to 0.6 mm. The difference between experimental results and analytical results is mainly caused by values of friction factor for using to calculate pressure drop through a small diameter capillary tube under 0.74mm. The experimental equation is derived from capillary tube test data using curve fitting method.

  • PDF