R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구 (Performance characteristics of a multi type refrigerator)

  • 안지훈;장용희;김용찬;장의영;박용종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.292-297
    • /
    • 2008
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi function refrigerator which has different purposes in each evaporator. In this study, the performance of a multi type refrigerator system, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator system was tested by varying the number of refrigerator cabinet, refrigerant charge amount, temperature condition. Based on experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type) At the same external load condition, the COP of the multi type refrigerator was $1.22{\sim}1.29$, but the COP of the single type refrigerator was 1.0.

  • PDF

R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Multi Type Refrigerator Using R600a)

  • 안지훈;장용희;김용찬;최원섭;오승환;김창년;이재승
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.222-228
    • /
    • 2009
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi type refrigerator combining these refrigerators to save space and energy consumption. In this study, the performance of a multi type refrigerator, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator was tested by varying the number of refrigerator cabinet, refrigerant charge, and temperature conditions. In addition, the multi type refrigerator with a suction line heat exchanger(SLHX) was tested to improve system performance. Based on the experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type system). Besides, the COP of the single system increased from 1.0 to 1.37, and those of the dual and triple system increased from 1.29 to 1.39, and 1.22 to 1.51, respectively, by applying the SLHX.

멀티냉장고용 에너지 절감형 전력변환기 및 통합 제어시스템 개발 (Development of Multi-refrigerator Energy-saving Power Converter and the Combined Control System)

  • 이상택;김희준;김대경
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.516-522
    • /
    • 2012
  • Recently trends of home appliance has been changed in house and the demand for functional refrigerator has been increased. Power consumption of refrigerator accounts for a large proportion in consumer electronics. Also, compressor accounts for most of the power consumption in refrigerator parts. Therefore, this paper proposes a multi-refrigerator system with single compressor & condenser fan in order to reduce energy. To verify the availability of the proposed multi refrigerant system, integration experiment is carried out.

모세관 변경에 따른 가정용 소형 멀티 냉동시스템의 성능에 관한 연구 (A Study on the Performance of a Domestic Small Multi Refrigerator According to a Capillary Tube Change)

  • 김상욱;이무연
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.763-771
    • /
    • 2005
  • This paper is an experimental study on the performance according to a capillary tube diameter and length in a domestic small multi refrigerator[kimchi refrigerator]. Pressure drop in a capillary tube is predicted by theoretical analysis and experimental method as the reduction of capillary tube diameter from 0.74 to 0.6 mm. The differences between experimental results and analytical results are mainly caused by friction factor in a capillary tube. Because there are no adequate equations used to calculate pressure drop of capillary tube diameter under 1.0mm. The empirical equations necessary for interpretation of capillary tube were derived from capillary tube test results data using curve fitting method. This study shows that the optimized designs of system, which is capillary tube length and refrigerant charge amount, are 2000mm, 83g at the capillary tube diameter 0.6mm and 3000mm, 73g at the capillary tube diameter 0.74mm. And capillary design tools and system matching techniques necessary for development of the kimchi refrigerator were also developed through this study.

다공판을 활용한 냉장고 저주파 흡음개선 (Low frequency sound absorption improvement in refrigerator using multi perforated plate)

  • 권호진;김형진;송경준;김태훈;구준효
    • 한국음향학회지
    • /
    • 제41권6호
    • /
    • pp.723-729
    • /
    • 2022
  • 본 논문은 냉장고 기계실 내부 압축기의 저주파 대역에서 소음을 줄이기 위해 다공판을 사용하는 연구이다. 흡음 결과를 예측하기 위해 흡음재의 표면 임피던스를 측정하여, 측정된 임피던스 결과를 이용하여 Finite Element Method(FEM) 분석에 사용된 결과가 실험값과 거의 유사함을 확인하였다. 다공판의 구멍 직경과 배치를 조절하여 냉장고 기계실 내부의 목표 주파수 대역에서 동작할 수 있는 흡음구조를 설계하였다. 기계실에 다공판과 흡음재를 결합한 흡음구조를 적용하여 기존의 흡음재의 주파수 대역보다 낮아진 저주파대역 소음저감 효과를 확인하였다.

다중재질 접합구조의 등가물성을 이용한 효과적 냉장고 구조 변형 분석에 관한 연구 (Effective Analysis on the Mechanical Behavior of a Refrigerator using Equivalent Material Properties of Multi-layers)

  • 박정현;이동규;박상후;박기홍;하병국;김형식
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1228-1235
    • /
    • 2012
  • A refrigerator has many components which are made from diverse materials such as metal, polymer, plastic, and rubber. So, it generally requires much time and efforts to build up an analysis model in finite element analysis. In this work, to reduce the computational time and efforts a simplified modeling method was proposed for the analysis of a refrigerator. Occasionally, a stick-slip noise occurs in a refrigerator due to relative slip between shelf and inner-case. When we solve the problem by a FE analysis, we should model the structures with detail for considering the contact conditions; by this reason, too many efforts are consumed in the conventional analysis method. Through this work, we shows the concept of simplifying approach and a good agreement with the results of a real model analysis. And also, the evaluation of the proposed method and the application of contact analysis using the simplified model are discussed.

Electric Load Signature Analysis for Home Energy Monitoring System

  • Lu-Lulu, Lu-Lulu;Park, Sung-Wook;Wang, Bo-Hyeun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제12권3호
    • /
    • pp.193-197
    • /
    • 2012
  • This paper focuses on identifying which appliance is currently operating by analyzing electrical load signature for home energy monitoring system. The identification framework is comprised of three steps. Firstly, specific appliance features, or signatures, were chosen, which are DC (Duty Cycle), SO (Slope of On-state), VO (Variance of On-state), and ZC (Zero Crossing) by reviewing observations of appliances from 13 houses for 3 days. Five appliances of electrical rice cooker, kimchi-refrigerator, PC, refrigerator, and TV were chosen for the identification with high penetration rate and total operation-time in Korea. Secondly, K-NN and Naive Bayesian classifiers, which are commonly used in many applications, are employed to estimate from which appliance the signatures are obtained. Lastly, one of candidates is selected as final identification result by majority voting. The proposed identification frame showed identification success rate of 94.23%.

서울 및 경기지역 가정에서의 얼음 사용 실태에 관한 연구 (The Utilization of Ice at Home in Seoul and Kyunggi-Do Area)

  • 장정옥;이영미
    • 동아시아식생활학회지
    • /
    • 제7권3호
    • /
    • pp.355-363
    • /
    • 1997
  • This study was designed to investigate development points for automatic ice maker which met consumer's demand. Basic data about using ices in Korean's dietary life, were collected from Seoul and Kyunggi-do residences and analyzed by SPSS program. The results were as follows; 93.7% of respondents had 3 major domestic brands' refrigerator and 41.4% of them had medium-large capacity(400-519L). 65% of respondents had a refrigerator that was purchased less than five years. 15.5% of respondents had one more refrigerator. Among of them, major refrigerator was located in kitchen(67.7%) and minor was in kitchen(29.8%) and in veranda or multi-purpose room(26.3%). 66.2% of respondents always prepared ices in ice container, and 85% of them used ice only in summer. Boiling water with barley or corn was used as drinking water (45.6%) and boiled or purified tap water was used to make ice (38.6%) commonly. In cooking, ice was used especially in cold soup with cucumber and seaweed(89.9%), ice-tea or ice-coffee(81%), and fruit punch(64%). The next commonly using ice was adding in alcoholic beverage such as whiskey(57.4%), in Koreans traditional drink(Misugaru) (45.2%) and juice. The purpose of using ice was to cool in soft drink (58.6%), to cool in cooking food(19.9%), to eat ice itself(14.0%), and to enjoy more fantastic taste and mood(3.8%). In whiskey, the purpose of using ices was to control alcoholic content (52.9%). There was no significant difference between sex in the purpose of using ice, but there was significant differences between age(p<0.05). Seasonal variations in using ice, there were significant differences according to sex, age, roles in family, amount of preparation of ice, socio-economic level and brand and capacity of refrigerator in respondent's home.

  • PDF

단열 특성을 고려한 가정용 소형 멀티 냉동시스템의 성능에 관한 연구 (Performance Evaluations of a Residential Small Multi-Refrigeration System Considering the Adiabatic Characteristics)

  • 이무연;;;김상욱;김용찬
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.868-875
    • /
    • 2007
  • In this paper, performance characteristics of a domestic kim-chi refrigerator are predicted by using the theoretical calculation and experimental method. The objective of this study is to find out the best design points of the refrigeration system and to calculate an adiabatic characteristic with variation to outdoor temperatures. The best design points such as refrigerant charge amount and capillary length were experimentally investigated. And the theoretical calculation is conducted as a function of calculation parameters and outdoor temperatures. According to this study results, the best design points of a refrigeration system with 2 rooms are 95 g of a refrigerant charge amount and 3500 / 3500 mm of capillary lengths and the best design points of a refrigeration system with 3 rooms are 100 g of a refrigerant charge amount and 3000/3000/6000mm of capillary lengths. And the power consumptions of both systems are 13.57 and 18.2 kWh/month. The worst part of heat loss is a front side of a domestic kim-chi refrigerator body.

모세관 내경 축소에 따른 소형멀티 냉동시스템의 성능특성변화 (A Study on Performance Characteristics of R134a Variation with a Capillary Tube Diameter and Length in a Domestic Small multi Refrigerator [Kim_Chi Refrigerator])

  • 이무연;최석재;김상욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1598-1603
    • /
    • 2004
  • This paper is an experimental study on the performance characteristic with a variation of capillary diameter and length. The performance characteristic of a refrigeration system is predicted that it is occurring changes of flow pattern and pressure drop in a capillary tube because of reduction of capillary diameter 0.74 to 0.6 mm. The difference between experimental results and analytical results is mainly caused by values of friction factor for using to calculate pressure drop through a small diameter capillary tube under 0.74mm. The experimental equation is derived from capillary tube test data using curve fitting method.

  • PDF