• Title/Summary/Keyword: multi-pulse

Search Result 481, Processing Time 0.032 seconds

A Study on Sapphire Wafer Scribing Using Picosecond Pulse laser (피코초 펄스 레이저를 이용한 사파이어 웨이퍼 스크라이빙에 관한 연구)

  • Moon, Jae-Won;Kim, To-Hoon
    • Laser Solutions
    • /
    • v.8 no.2
    • /
    • pp.7-12
    • /
    • 2005
  • The material processing of UV nanosecond pulse laser cannot be avoided the material shape change and contamination caused by interaction of base material and laser beam. Nowadays, ultra short pulse laser shorter than nanosecond pulse duration is used to overcome this problem. The advantages of this laser are no heat transfer, no splashing material, no left material to the adjacent material. Because of these characteristics, it is so suitable for micro material processing. The processing of sapphire wafer was done by UV 355nm, green 532nm, IR 1064nm. X-Y motorized stage is installed to investigate the proper laser beam irradiation speed and cycles. Also, laser beam fluence and peak power are calculated.

  • PDF

A Study on the Laser Beam Characteristics during Al203 Ceramic Microhole Machining (Al203 세라믹 미세구멍 가공 시 레이저빔 특성에 관한 연구)

  • 백병만;이건상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1056-1059
    • /
    • 2001
  • These days, as dynamic function and special properties to compare traditional material, $Al_20_3$ ceramic use all over the industry. But it is very difficult to process because of high hardness and brittleness. Therefore, in this paper, it was investigated that laser process parameter which can produce appropriate quality of $Al_20_3$ ceramic microhole machining.

  • PDF

Characteristics of multi-stage dye laser amplification and Second Harmonic Generation (색소레이저의 다단 증폭 및 SHG 특성)

  • 이영우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.946-949
    • /
    • 2004
  • We obtained ultra-short single pulse with an energy of 80 uJ from Distributed feedback Dye laser. Using three stages of amplifiers constructed by two stages of dye amplifiers and one bethune cell amplifier, we obtained high power pulse and second harmonic generation with BBO in ultraviolet region.

A Multi-megawatt Long Pulse Ion Source of Neutral Beam Injector for the KSTAR

  • Chang, Doo-Hee;Seo, Chang-Seog;Jeong, Seung-Ho;Oh, Byung-Hoon;Lee, Kwang-Won;Kim, Jin-Choon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.719-720
    • /
    • 2004
  • A multi-megawatt long pulse ion source (LPIS) of neutral beam injector was developed for the KSTAR. Beam extraction experiments of the LPIS were carried out at the neutral beam test stand (NBTS). Design requirements for the ion source were 120 kV/65 A deuterium beam and a 300 s pulse length. A maximum ion density of $9.1310^{11}$ $cm^{-3}$ was measured by using electric probes, and an optimum arc efficiency of 0.46 A/kW was estimated with ion saturation current of the probes, arc power, and total beam area. An arcing problem, caused by the structural defect of decelerating grid supporter, in the third gap was solved by the blocking of backstream ion particles, originated from the plasma in the neutralizer duct, through the unnecessary spaces on the side of grid supporter. A maximum drain power of 1.5 MW (i.e. 70 kV/21 A) with hydrogen was measured for a pulse duration of 0.5 s. Optimum beam perveance was ranged from 0.75 to 0.85. An improved design of accelerator for the effective control of beam particle trajectory should provide higher beam perveance.

  • PDF

TH-UWB System through Pulse Shaping and Avoiding Interference Technique (펄스 성형을 통한 TH-UWB 시스템 구현과 간섭 회피 제안)

  • Chang, Hong-Mo;Kim, Tae-Hun;Kim, Dong-Hee;Park, Ho-Hwan;Kwak, Kyung-Sub
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.3
    • /
    • pp.111-121
    • /
    • 2007
  • In this paper, we propose a TH-Multiband-UWB system through pulse shaping to fit in domestic UWB spectrum regulation. We propose the transmission pulse of Multi-Carrier type for pulse shaping and use Cognitive Radio to detect interfering frequency. We use Genetic Algorithm in Cognitive Radio's calculation propose and propose solution of interference problem between TH-UWB using Cognitive Radio and typical MB-OFDM UWB system or other communication systems. In this paper, we explain how Cognitive Engine detects the interfering frequency. The technique of TH-Multiband-UWB system using Cognitive Radio shows a good performance in interference condition.

  • PDF

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

Peak Detection of Pulse Wave Based on Fuzzy Inference and Multi Sub-Band Filters for U-Healthcare (U-헬스케어를 위한 퍼지추론과 다중 하위대역 필터를 기반한 맥파 최대치 검출)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2159-2164
    • /
    • 2008
  • Ubiquitous healthcare system is system that monitors and manages user's health information, and most important in the healthcare system is accuracy of the measured health data. But, the accuracy changes remarkably according to user's motion artifacts in real life. To elevate accuracy of health data, we proposed new algorithm to detect maximum point of pulse wave for heart rate extraction. and the proposed algorithm is to detect maximum points detect of pulse wave in photo-plethysmography signal included motion artifacts by fuzzy inference and multi sub-band filters. In results of experiment to evaluate the performance of the proposed algorithm, we could verify the proposed algorithm extracted maximum point of pulse wave in complex motion artifacts.

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

A study on the pulse forming of pulsed $CO_2$ laser using active multi-pulse superposition (능동적 다중 펄스 중첩법(AMPS)을 적용한 펄스형 $CO_2$ 레이저의 펄스 성형에 대한 연구)

  • Chung, Hyun-Ju;Park, Sung-Joon;Jung, Yong-Ho;Song, Gun-Ju;Kim, Hee-Je;Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1631-1633
    • /
    • 2001
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing and the pulseshape is regarded as a dominant factor due to the specific property of processing materials. Therefore, in this study, a variable pulse width, high duty cycle Pulse Forming Network(PFN) is constructed by time sequently. The power supply for this experiment consists of three switching circuits. The PFN elements operate at low voltage and drive the primary of HV leakage transformer. The secondary of the transformer has a full-wave rectifier, which passes the pulse energy to the load in a continuous sequence of properly phased and nested increments. We investigated laser pulse width as various delay time among three switching circuit. As a result, we tan obtain various laser pulse width from about 4ms to 10ms. The maximum laser pulse width obtained at this experiment was about 10ms at delay time of 4ms among each switching circuit.

  • PDF

Design and Construction of Multi-wire Proportional Counter and Preamplifier for Measurement of Charged Particle (하전입자의 측정을 위한 다중선 비례계수기와 전치증폭기의 설계 제작)

  • Kim, Jong-Soo;Yoon, Suk-Chull
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.139-143
    • /
    • 1996
  • A multi-wire proportional counter with large sensitive area was designed and constructed considering diameter of anode wire. its material and space. A preamplifier connecting detector to main amplifier or counter was also designed and constructed for measurement output pulse from multi-wire proportional counter. The preamplifier was composed of charge-sensitive differential circuit. clipping circuit and amplification circuit. To test the performance of this equipment, terminal output pulse from the preamplifier was measured and compared with noise For these tests $^{239}Pu(360 Bq)\;and\; ^{90}Sr/^{90}Y(250 Bq)$ were used as radiation sources. The noise ingredient contributing to the maximum amplitude(180mV from $^{239}Pu$ and 200 mV from $^{90}Sr/^{90}Y$) was found to be very small(8 mV) Piled up pulse occurring at the output pulse of charge-sensitive differential circuit was measured as an independent pulse since this affected the amplification in the clipping circuit and amplification circuit. This information can be used to improve the loss of measurement due to piled up pulse.

  • PDF