• Title/Summary/Keyword: multi-objective

Search Result 2,141, Processing Time 0.029 seconds

Prospective Multi-Center Korean Registry of Transcatheter Arterial Chemoembolization with Drug-Eluting Embolics for Nodular Hepatocellular Carcinoma: A Two-Year Outcome Analysis

  • Myungsu Lee;Jin Wook Chung;Kwang-Hun Lee;Jong Yun Won;Ho Jong Chun;Han Chu Lee;Jin Hyoung Kim;In Joon Lee;Saebeom Hur;Hyo-Cheol Kim;Yoon Jun Kim;Gyoung Min Kim;Seung-Moon Joo;Jung Suk Oh
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1658-1670
    • /
    • 2021
  • Objective: To assess the two-year treatment outcomes of chemoembolization with drug-eluting embolics (DEE) for nodular hepatocellular carcinoma (HCC). Materials and Methods: This study was a prospective, multicenter, registry-based, single-arm trial conducted at five university hospitals in Korea. Patients were recruited between May 2011 and April 2013, with a target population of 200. A DC Bead loaded with doxorubicin was used as the DEE agent. Patients were followed up for two years. Per-patient and per-lesion tumor response analysis, per-patient overall survival (OS) and progression-free survival (PFS) analysis, and per-lesion tumor control analysis were performed. Results: The final study population included 152 patients, with 207 target lesions for the per-lesion analysis. At one-month, six-month, one-year, and two-year per-patient assessments, complete response (CR) rates were 40.1%, 43.0%, 33.3%, and 19.6%, respectively. The objective response (OR) rates were 91.4%, 55.4%, 35.1%, and 19.6%, respectively. The cumulative two-year OS rate was 79.7%. The cumulative two-year PFS rate was 22.4% and the median survival was 9.3 months. In multivariable analysis, the Child-Pugh score (p = 0.019) was an independent predictor of OS, and tumor multiplicity (p < 0.001), tumor size (p = 0.020), and Child-Pugh score (p = 0.006) were independent predictors of PFS. In per-lesion analysis, one-month, six-month, one-year and two-year CR rates were 57.5%, 58.5%, 45.2%, and 33.3%, respectively, and the OR rates were 84.1%, 65.2%, 46.6%, and 33.3%, respectively. The cumulative two-year per-lesion tumor control rate was 36.2%, and the median time was 14.1 months. The Child-Pugh score (p < 0.001) was the only independent predictor of tumor control. Serious adverse events were reported in 11 patients (7.2%). Conclusion: DEE chemoembolization for nodular HCCs in the Korean population showed acceptable survival, tumor response, and safety profiles after a two-year follow-up. Good liver function (Child-Pugh score A5) was a key predictor of per-patient OS, PFS, and per-lesion tumor control.

A Study on Design Education Re-engineering by Multi-disciplinary Approach (다학제적 접근을 통한 대학디자인 교육혁신 프로그램 연구)

  • Lee, Soon-Jong;Kim, Jong-Won;Chu, Wu-Jin;Chae, Sung-Zin;Yoon, Su-Hyun
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.299-314
    • /
    • 2007
  • For the past 20 years, the growth and development of university-design-educational institutes contributed to the industrial development of our country. Due to the technological fluctuation and changes in the industrial structure in the latter half of the 20th century, the enterprise is demanding professionally-oriented design manpower. The principle which appears from instances of the advanced nations is to accommodate the demands in social changes and apply them to educational design programs. In order to respond promptly to the industrial demand especially, the advanced nations adopted "multidisciplinary design education programs" to lead innovation in the area of design globally. The objective of the research consequently is to suggest an educational system and a program through which the designer can be educated to obtain complex knowledge and the technique demanded by the industry and enterprise. Nowadays in order to adapt to a new business environment, designers specially should have both the knowledge and techniques in engineering and business administration. We suggest that the IPDI, a multidisciplinary design educational system and program is made up of the coordinated operation of major classes, on-the-job training connection, educational system for research base creation, renovation design development program for the application and the synthesis of alternative proposals about the training facility joint ownership by connecting with the education of design, business administration and engineering.

  • PDF

Recent Trends of Immunologic Studies of Herbal Medicine on Rheumatoid Arthritis (류마티스 관절염에 대한 한약의 면역학적 연구동향)

  • Choi, Do-young;Lee, Jae-dong;Back, Yong-hyeon;Lee, Song-shil;Yoo, Myung-chul;Han, Chung-soo;Yang, Hyung-in;Park, Sang-do;Ryu, Mi-hyun;Park, Eun-kyung;Park, Dong-seok
    • Journal of Acupuncture Research
    • /
    • v.21 no.4
    • /
    • pp.177-196
    • /
    • 2004
  • Objective : Rheumatoid arthritis is an autoimmune disease that pathogenesis is not fully understood and one of the most intractable musculoskeletal diseases. The concern in the immunopathogenesis of rheumatoid arthritis has been increased since 1980's and many immunotherapeutic agents including disease-modifying antirheumatic drugs (DMARDs) were developed and became the mainstay of treatment of rheumatoid arthritis. However, the cure of the disease has hardly been achieved. In oriental medicine, rheumatoid arthritis is related to Bi-Zheng(痺證), that presents pain, swelling, andlor loss of joint function as major clinical manifestations, and also known to be deeply involved in suppression of immune function related to weakness of Jung-Ki(正氣). The herbal medicine, empirically used, could be a potential resource of development of new immunotherapeutic agents for rheumatoid arthritis. Methods : We developed a search strategy using terms to include "rheumatoid arthritis and herbal medicine" combined with "Chinese medicine" and/or "Oriental medicine". The search was focused on experimental studies of herbal medicine (January 1999 to May 2004), which is known to have effects on immune function of patients with rheumatoid arthritis. Computerized search used Internet databases including KISS and RISS4U (Korea), CNKI (China), MOMJ (Main Oriental Medicine Journal, Japan), and PubMed. The articles were selected from journals of universities or major research institutes. Results : The literature search for experimental studies on effects of herbal medicine on immunity of rheumatoid arthritis retrieved a total of 21 articles (Korea; 8, China ; 12, Japan ; 1). Of 21 articles, 10 were related to single-drug formula, 2 to drug interaction, and 9 to multi-drug formula. Single-drug formula was mainly used for aqua-acupuncture and researches on active components. Studies of drug interaction emphasized harmony of Ki-Hyul(氣血) and balance of Han-Yeul(寒熱). Multi-drug regimen was mainly found among formulas for Bo-Ki-Hyul(補氣血) and Bo-Sin(補腎). Conclusion : Studies on rheumatoid arthritis were performed both in vitro and in vivo in vitro study, LPS-stimulated splenocytes and synoviocytes were treated with herbal medicine, resulting in proliferation and activation of immune cells and suppression of cytokine activities in vivo study CIA animal model demonstrated that herbal medicine decreased antibody production and improved function of immune cells. In cellular and molecular study herbal medicine showed profound effects on the level of mRNA expression of certain cytokines related to immune function. This study revealed that herbal medicine has significant immune modulatory action and could be used for recovery of immune dysfunction of rheumatoid arthritis patients.

  • PDF

Comparison Between Methods for Suitability Classification of Wild Edible Greens (산채류 재배적지 기준설정 방법 간의 비교 분석)

  • Hyun, Byung-Keun;Jung, Sug-Jae;Sonn, Yeon-Kyu;Park, Chan-Won;Zhang, Young-Seon;Song, Kwan-Cheol;Kim, Lee-Hyun;Choi, Eun-Young;Hong, Suk-Young;Kwon, Sun-Ik;Jang, Byoung-Choon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.5
    • /
    • pp.696-704
    • /
    • 2010
  • The objective of this study was analysis of two methods of land suitability classification for wild edible green. One method was Maximum limiting factor method (MLFM) and the other was Multi-regression method (MRM) for land suitability classification for wild edible green. The investigation was carried out in Pyeongchang, Hongcheong, Hoeingseong, and Yanggu regions in Korea. The obtained results showed that factors related to the decision classification of the land suitability for wild edible green cultivation were land slope, altitude, soil morphology and gravel contents so on. The classification of the best suitability soil for wild edible greens were fine loamy (silty), valley or fan of soil morphology, well drainage class, B-slope (2~7%), available soil depth deeper than 100cm, and altitude higher than 501m. Contribution of soil that influence to crop yields using Multi-regression method were slope 0.30, altitude 0.22, soil morphology 0.13, drainage classes 0.09, available soil depth 0.07, and soil texture 0.01 orders. Using MLFM, area of best suitable land was 0.2%, suitable soil 15.0%, possible soil 16.7%, and low productive soil 68.0% in Hongcheon region of Gangwon province. But, area of best suitable land was 35.1%, suitable soil 30.7%, possible soil 10.3%, and low productive soil 23.9% by MRM. There was big difference of suitable soil area between two methods (MLFM and MRM). When decision classificatin of the land suitability for wild edible green cultivation should consider enough analysis methods. Furthermore, to establishment of land suitability classification for crop would be better use MRM than MLFM.

A STUDY ON THE MICROLEAKAGE OF DENTIN BONDING SYSTEMS (상아질 접착제의 미세누출에 관한 연구)

  • Son, Jeong-Min;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho;Park, Yang, Ji-il
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.619-627
    • /
    • 2008
  • The objective of this study was to compare the microleakage of five adhesive systems in the enamel and dentin of permanent teeth. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 25 extracted human molar teeth. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM), Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL) and G-Bond (GB). The results were as follows: 1. At the enamel margins, PL showed the highest leakage value(0.85), and others showed values of SB(0.55), GB(0.50), SM(0.35) and SE(0.25) in decreasing order. There were statistically significant differences in PL vs. SM and PL vs. SE(p<0.05). 2. At the dentin margins, GB showed the highest leakage value(2.10), and others showed values of SE(1.45), PL(1.40), SB(1.05), SM(0.70) in decreasing order. There were statistically significant differences in GB vs. SB and GB vs. SM(p<0.05). 3. Dentin margins showed high dye penetration rate than enamel margins in all material tested groups and there were statistically significant differences for SE, PL and GB.

  • PDF

THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES ON PRIMARY AND PERMANENT TEETH (유치와 영구치에서 치과용 접착제의 전단결합강도)

  • Choi, Jin-Young;Choi, Nam-Ki;Park, Yeong-Joon;Choi, Choong-Ho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.579-589
    • /
    • 2007
  • The objective of this study was to compare the shear bond strengths of five adhesive systems to the enamel and dentin of primary and permanent teeth. Fifty noncarious primary and fifty permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), GBond (GB). For the shear bonding test, the labial and lingual surfaces of primary and permanent teeth were used. To obtain a flat surface, the labial and lingual surfaces of the teeth were sanded on $SiO_2$ with number 600 grit and then divided into 20 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. For primary enamel, shear bond strengths of SM and SB were significantly higher than that of SE and also SM, SB, and PL were higher than GB(p<0.05). 2. For primary dentin, there were no significant differences among the shear bond strengths of any other bonding systems except difference between SE and GB. 3. For permanent enamel, SB showed significantly higher mean shear bond strength than those of any other bonding systems(p<0.05). 4. For permanent dentin, SM showed significantly higher mean shear bond strength than that of PL and GB(p<0.05). 5. Between the primary enamel and dentin, there were significant differences in SM, SB, and GB, whereas there was statistically significant difference in PL between the permanent enamel and dentin(p<0.05). 6. Between the primary and permanent teeth on enamel, there were no significant differences among all bonding systems, whereas there were statistically significant differences in SM and SB between the primary and permanent teeth on dentin(p<0.05).

  • PDF

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES (다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구)

  • Choi, Nam-Ki;Cho, Seong-Hoon;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • The objective of this study was to compare the shear bond strengths of five dentin adhesive systems cured with three different light curing sources. Seventy five noncarious permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), G-Bond (GB). And three light curing unit systems were used: Elipar Free light 2(LED), OptiLux 501 (Halogen), Flipo (PAC). For the shear bonding test, the labial and lingual surfaces of permanent teeth were used. To obtain a flat dentin surface, the labial and lingual surfaces of the teeth were sanded on SiO2 with number 600 grit and then divided into 15 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. When cured with Freelight 2, the shear bond strength of SM was significantly higher than that of PL, GB (p<0.05), whereas no significant difference was found among those of any other bonding agents. 2. When cured with Optilux 501, the shear bond strength of SM was significantly higher than those of any other bonding agents (p<0.05), whereas no singnificant difference was found among those of andy other bonding agents. 3. When cured with Flipo, the shear bond strength of SM was significantly higher than those of SB, SE, GB (p<0.05), whereas no significant differences was found among those of any other bonding agents. 4. For comparison according to three different light cure unit system, except SB and GB, each three dentin bonding agents showed no significant difference. For SB, only Freelight 2 was significantly higher than the others, with no significant difference between Optilux 501 and Flip. For GB, Statistically significant difference was found only between Freelight and Flipo.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF