• Title/Summary/Keyword: multi-generator

Search Result 413, Processing Time 0.038 seconds

A Study on Probabilistic Reliability Evaluation of Power System Considering Solar Cell Generators (태양광발전원(太陽光發電原)을 고려한 전력계통(電力系統)의 확률논적(確率論的)인 신뢰도(信賴度) 평가(評價)에 관한 연구(硏究))

  • Park, Jeong-Je;Liang, Wu;Choi, Jae-Seok;Cha, Jun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.486-495
    • /
    • 2009
  • This paper proposes a new methodology on reliability evaluation of a power system including solar cell generators (SCG). The SCGs using renewable energy resource such as solar radiation(SR) should be modeled as multi-state operational model because the uncertainty of the resource supply may occur an effect as same as the forced outage of generator in viewpoint of adequacy reliability of system. While a two-state model is well suited for modeling conventional generators, a multi-state model is needed to model the SCGs due to the random variation of solar radiation. This makes the method of calculating reliability evaluation indices of the SCG different from the conventional generator. After identifying the typical pattern of the SR probability distribution function(pdf) from SR actual data, this paper describes modelling, methodology and details process for reliability evaluation of the solar cell generators integrated with power system. Two test results indicate the viability of the proposed method.

Development of a Ejection Gas Generator for precluding Erosive Burning by using Bundle Cylindrical Grains (침식연소가 방지되는 사출용 다발 원통형 그레인 가스발생기 개발)

  • Oh, Seok-Jin;Cha, Hong-Seok;Jang, Seung-Gyo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.432-439
    • /
    • 2011
  • An achieving method of highly progressive pressure gradient is presented to enhance the missile ejection system's performance by using a gas generator in the condition of preventing erosive burning. To obtain and confirm a stable burning, a ground burning test was performed to evaluate the new methods of a radial-hole and a multi-row propellant grain. The test results show that a radial-hole grain takes good effect on erosive burning and not on ejection performance. On the other hand, a multi-row grain which reduces the legnth-to-diameter ratio(L/D) of grain is very effective to prevent the erosive burning and to enhance the ejection performance simultaneously.

  • PDF

Fuzzy Applications in a Multi-Machine Power System Stabilizer

  • Sambariya, D.K.;Gupta, Rajeev
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.503-510
    • /
    • 2010
  • This paper proposes the use of fuzzy applications to a 4-machine and 10-bus system to check stability in open conditions. Fuzzy controllers and the excitation of a synchronous generator are added. Power system stabilizers (PSSs) are added to the excitation system to enhance damping during low frequency oscillations. A fuzzy logic power system stabilizer (PSS) for stability enhancement of a multi-machine power system is also presented. To attain stability enhancement, speed deviation ($\Delta\omega$) and acceleration ($\Delta\varpi$) of the Kota Thermal synchronous generator rotor are taken as inputs to the fuzzy logic controller. These variables have significant effects on the damping of generator shaft mechanical oscillations. The stabilizing signals are computed using fuzzy membership functions that are dependent on these variables. The performance of the fuzzy logic PSS is compared with the open power system, after which the simulations are tested under different operating conditions and changes in reference voltage. The simulation results are quite encouraging and satisfactory. Similarly, the system is tested for the different defuzzification methods, and based on the results, the centroid method elicits the best possible system response.

Performance Analysis of digital phase shifter using Hilbert transform (힐버트 변환을 이용한 디지털 위상천이기의 성능 분석)

  • Seo, Sang Gyu;Jeong, Bong-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.39-44
    • /
    • 2013
  • In this paper digital phase-shifter for multi-arm spiral antennas was designed by using Hilbert transform. All frequency components in input signal are phase-shifted for 90 degree by Hilbert transform, and the transform is implemented by FIT and IFIT. Digital phase-shifter generates two signals with phase difference of 90 degree by using Hilbert transform from input signals sampled by analog-digital converter(ADC), and then the input signal is phase-shifted for a given phase by using two signals. Hilbert transform based on digital phase-shifter is designed by Xilinx System generator, and the effects of input noise, FIT point, sampling period, initial phase of input signal, and shifted phase are simulated and its results are compared with Matlab results.

Multi-Stage Generation Allocation Game Considering Ramp-rate Constraints (경쟁적 전력시장에서 발전기 증감발률을 고려한 다중시간 발전량 배분 게임)

  • Park, Yong-Gi;Park, Jong-Bae;Roh, Jae-Hyung;Kim, Hyeong-Jung;Shin, Jung-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.509-516
    • /
    • 2011
  • This paper studies a novel method to find the profit-maximizing Nash Equilibriums in allocating generation quantities with consideration of ramp-rates under competitive market environment. Each GenCo in a market participates in a game to maximize its profit through competitions and play a game with bidding strategies. In order to find the Nash equilibriums it is necessary to search the feasible combinations of GenCos' strategies which satisfy every participant's profit and no one wants various constraints. During the procedure to find Nash equilibriums, the payoff matrix can be simplified as eliminating the dominated strategies. in each time interval. Because of the ramp-rate, generator's physically or technically limits to increase or decrease outputs in its range, it can restrict the number of bidding strategies of each generator at the next stage. So in this paper, we found the Nash Equilibriums for multi-stage generation allocation game considering the ramp-rate limits of generators. In the case studies, we analyzed the generation allocation game for a 12-hour multi-stage and compared it with the results of dynamic economic dispatch. Both of the two cases were considered generator's ramp-rate effects.

Multi-objective Fuzzy-optimization of Crowbar Resistances for the Low-Voltage Ride-through of Doubly Fed Induction Wind Turbine Generation Systems

  • Zhang, Wenjuan;Ma, Haomiao;Zhang, Junli;Chen, Lingling;Qu, Yang
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1119-1130
    • /
    • 2015
  • This study investigates the multi-objective fuzzy optimization of crowbar resistance for the doubly fed induction generator (DFIG) low-voltage ride-through (LVRT). By integrating the crowbar resistance of the crowbar circuit as a decision variable, a multi-objective model for crowbar resistance value optimization has been established to minimize rotor overcurrent and to simultaneously reduce the DFIG reactive power absorbed from the grid during the process of LVRT. A multi-objective genetic algorithm (MOGA) is applied to solve this optimization problem. In the proposed GA, the value of the crowbar resistance is represented by floating-point numbers in the GA population. The MOGA emphasizes the non-dominated solutions and simultaneously maintains diversity in the non-dominated solutions. A fuzzy-set-theory-based is employed to obtain the best solution. The proposed approach has been evaluated on a 3 MW DFIG LVRT. Simulation results show the effectiveness of the proposed approach for solving the crowbar resistance multi-objective optimization problem in the DFIG LVRT.

Design of Single/Multiband Impulse Generator Using SRD for UWB(Ultra Wideband) Technique (SRD를 이용한 UWB 기술용 단일/멀티밴드 Impulse Generator의 설계)

  • Kim, Ki Nam;Kim, Ihn Seok
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, an impulse generator for UWB(Ultra Wide-band) technique with great possibility to be adopted as a next generation indoor WLAN(Wireless Local Area Network) has been designed by using SRD(Step Recovery Diode). Design goal is to design an impulse generator with simple structure, low cost, small size, and high performance. The impulse generator satisfied by FCC's regulation ( frequency range: 3.1~10.6 GHz, limit of power level: -41.25 dBm ) has been simulated by using ADS(Advanced Design System) which is the trade name of the Agilent Technologies. The output power of the impulse generator has been explained separately for single and multi band purposes, respectively.

  • PDF

Comparison of High Frequency Detailed Generator Models for Partial Discharge Localization

  • Hassan Hosseini, S.M.;Hosseini Bafghi, S.M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1752-1758
    • /
    • 2015
  • This paper presents partial discharge localization in stator winding of generators using multi-conductor transmission line (MTL) and RLC ladder network models. The high-voltage (HV) winding of a 6kV/250kW generator has been modeled by MATLAB software. The simulation results of the MTL and the RLC ladder network models have been evaluated with the measurements results in the frequency domain by applying of the Pearson’s correlation coefficients. Two PD generated calibrator signals in kHz and MHz frequency range were injected into different points of generator winding and the signals simulated/measured at the both ends of the winding. For partial discharge localization in stator winding of generators is necessary to calculate the frequency spectrum of the PD current signals and then estimate the poles of the system from the calculated frequency spectrum. Finally, the location of PD can be estimated. This theory applied for the above generator and the simulation/measured results show the good correlation for PD Location for RLC ladder network and MTL models in the frequency range of kHz (10kHz<f<1MHz) and MHz (1MHz<f<5MHz) respectively.

Wear Characteristics of Multi- span Tube Due to Turbulence Excitation (다경간 전열관의 난류 가진에 의한 마모특성 연구)

  • Kim, Hyung-Jin;Sung, Bong-Zoo;Park, Chi-Yong;Ryu, Ki-Whan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.904-911
    • /
    • 2006
  • A modified energy method for the fretting wear of the steam generator tube is proposed to calculate the wear-out depth between the nuclear steam generator tube and its support. Estimation of fretting-wear damage typically requires a non-linear dynamic analysis with the information of the gap velocity and the flow density around the tube. This analysis is very complex and time consuming. The basic concept of the energy method is that the volume wear rate due to the fretting-wear phenomena Is related to work rate which is time rate of the product of normal contact force and sliding distance. The wearing motion is due to dynamic interaction between vibrating tube and its support structure, such as tube support plate and anti-vibration bar. It can be assumed that the absorbed work rate would come from turbulent flow energy around the vibrating tube. This study also numerically obtains the wear-out depth with various wear topologies. A new dissection method is applied to the multi-span tubes to represent the vibrational mode. It turns out that both the secondary side density and the normal gap velocity are important parameters for the fretting-wear phenomena of the steam generator tube.

Magnetic Field Calculation and Multi-objective Optimization of Axial Flux Permanent Magnet Generator with Coreless Stator Windings

  • Zhu, Jun;Li, Shaolong;Song, Dandan;Han, Qiaoli;Li, guanghua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1586-1595
    • /
    • 2018
  • For the problem that the complexity of 3-D modeling and multi parameter optimization, as well as the uncertainty of the winding factor of axial flux permanent magnet generator with coreless windings. The complex 3-D model was simplified into 2-D analytic model, and an analytical formula for the winding factor that adapting different coreless stator winding is proposed in this paper. The analytical solution for air-gap magnetic fields, no-load back EMF, electromagnetic torque, and efficiency are calculated by using this method. The multiple objective and multivariable optimization of the maximum fundamental and the minimum harmonic content of back EMF are performed by using response surface methodology. The proposed optimum design method was applied to make a generator. The generator was tested and the calculated results are compared with the proposed method, which show good agreements.