• Title/Summary/Keyword: multi-cycle

Search Result 715, Processing Time 0.03 seconds

Residual seismic performance of steel bridges under earthquake sequence

  • Tang, Zhanzhan;Xie, Xu;Wang, Tong
    • Earthquakes and Structures
    • /
    • v.11 no.4
    • /
    • pp.649-664
    • /
    • 2016
  • A seismic damaged bridge may be hit again by a strong aftershock or another earthquake in a short interval before the repair work has been done. However, discussions about the impact of the unrepaired damages on the residual earthquake resistance of a steel bridge are very scarce at present. In this paper, nonlinear time-history analysis of a steel arch bridge was performed using multi-scale hybrid model. Two strong historical records of main shock-aftershock sequences were taken as the input ground motions during the dynamic analysis. The strain response, local deformation and the accumulation of plasticity of the bridge with and without unrepaired seismic damage were compared. Moreover, the effect of earthquake sequence on crack initiation caused by low-cycle fatigue of the steel bridge was investigated. The results show that seismic damage has little impact on the overall structural displacement response during the aftershock. The residual local deformation, strain response and the cumulative equivalent plastic strain are affected to some extent by the unrepaired damage. Low-cycle fatigue of the steel arch bridge is not induced by the earthquake sequences. Damage indexes of low-cycle fatigue predicted based on different theories are not exactly the same.

A Study on the Impact of Business Cycle on Corporate Credit Spreads (글로벌 회사채 스프레드에 대한 경기요인 영향력 분석: 기업 신용스프레드에 대한 경기사이클의 설명력 추정을 중심으로)

  • Jae-Yong Choi
    • Asia-Pacific Journal of Business
    • /
    • v.14 no.3
    • /
    • pp.221-240
    • /
    • 2023
  • Purpose - This paper investigates how business cycle impacts on corporate credit spreads since global financial crisis. Furthermore, it tests how the impact changes by the phase of the cycle. Design/methodology/approach - This study collected dataset from Barclays Global Aggregate Bond Index through the Bloomberg. It conducted multi-regression analysis by projecting business cycle using Hodrick-Prescott filtering and various cyclical variables, while ran dynamic analysis of 5-variable Vector Error Correction Model to confirm the robustness of the test. Findings - First, it proves to be statistically significant that corporate credit spreads have moved countercyclicaly since the crisis. Second, It indicates that the corporate credit spread's countercyclicality to the macroeconomic changes works symmetrically by the phase of the cycle. Third, the VECM supports that business cycle's impact on the spreads maintains more sustainably than other explanatory variable does in the model. Research implications or Originality - It becomes more appealing to accurately measure the real economic impact on corporate credit spreads as the interaction between credit and business cycle deepens. The economic impact on the spreads works symmetrically by boom and bust, which implies that the market stress could impact as another negative driver during the bust. Finally, the business cycle's sustainable impact on the spreads supports the fact that the economic recovery is the key driver for the resilience of credit cycle.

New-Type Stirling Engine Employing the Scroll Mechanism (스크롤기구를 적용한 신형식 스털링 엔진)

  • Kim, Y.M.;Shin, D.K.;Lee, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1709-1716
    • /
    • 2003
  • Stirling engine is a heat engine with a high potential efficiency, multi-fuel capability, its low emission, quiet operation, very low maintenance requirement and long life. The Stirling cycle can ideally achieve optimum thermodynamic efficiency of the Carnot cycle. But the actual efficiency of practical reciprocating Stirling engine is much less than that of ideal Stirling cycle due to several mechanical limits. This paper presents a new-type Stirling engine employing the scroll mechanism superior to the reciprocating Stirling engine. The new-type Stirling engine is characterized as traits of continuous and wholly seperated compression and expansion, one-way flow, direct cooling and heating through the extensive surfaces of scroll wraps. By means of this traits, the new-type Stirling engine can achieve thermodynamic cycle closer to the ideal Stirling cycle and have many mechanical merits. Also, the new-type Stirling cycle can be applied as Stirling refrigerator and Duplex Stirling machine.

  • PDF

A Simulation Study on the Cascade Refrigeration Cycle for the Liquefaction of the Natural Gas [2]: An Application to the Multistage Cascade Refrigeration Cycle (천연가스 액화를 위한 캐스케이드 냉동사이클의 전산모사에 대한 연구 [2]: 다단 캐스케이드 냉동 사이클에 적용)

  • Cho, Jung-Ho;Kim, Yu-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.1013-1019
    • /
    • 2011
  • In this paper, simulation works for a multi-stage cascade refrigeration cycle using propane, ethylene and methane as refrigerants have been performed for the liquefaction of natural gas using Peng-Robinson equation of state built-in PRO/II with PROVISION release 8.3. The natural gas feed compositions were supplied from Korea Gas Corporation and the flow rate was assumed to be 5.0 million tons per annual. Supply temperature for propane refrigerant was fixed as $-40^{\circ}C$, that for ethylene refrigerant as $-95^{\circ}C$, and that for methane refrigerant as $-155^{\circ}C$. For the multi-stage refrigeration cycle, three-stage refrigeration was assumed for propane refrigeration cycle, two-stage refrigeration for ethylene refrigeration cycle and three-stage refrigeration for methane refrigeration cycle. Natural gas was finally cooled and liquefied to $-162^{\circ}C$ by Joule-Thomson expansion. Conclusively, 91.71% by mole of the natural gas liquefaction ratio was obtained through a cascade refrigeration cycle and Joule-Thomson expansion and 0.433 kW of compression power was consumed for the liquefaction of 1.0 kg/hr of natural gas.

Steady-State Performance Analysis of Air Conditioner with Multi-Indoor Units (복수 실내기를 가지는 에어컨의 정상상태 성능해석)

  • Hur, Hyun;Lee, Jin Wook;Jung, Eui Guk;Kim, Byung Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.11
    • /
    • pp.705-715
    • /
    • 2016
  • In this study, the cycle performance of an air conditioner with multi-indoor units is analyzed and simulated. The cycle performance could be predicted through the integration of mathematical formulation for these devices. The condenser pressure is obtained by an iteration process to match the mass flow rates of the compressor and the expansion valve and the evaporator pressure is determined by an iteration process, in which the suction super heat is tracing the targeted super heat. The required software was developed by system programming. the software algorithm is extended to predict the cycle performance of an air conditioner system with multi-indoor units, and then the numerical results are compared with experimental results. This mathematical model is validated from the result of experiments conducted on 8.3kW air conditioner. The errors in capacity, electronic power, and COP are found to be within 10% in general.

Development of 0D Multizone Combustion Model and Its Coupling with 1D Cycle-Simulation Model for Medium-Sized Direct-Injection Diesel Engine (중형 직분식 디젤 엔진의 0-D Multi-zone 연소 모델 및 1-D Cycle Simulation 연계 기법 개발)

  • Choi, Seung-Mok;Min, Kyoung-Doug;Kim, Ki-Doo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.615-622
    • /
    • 2010
  • In this study, a 0D multizone spray-combustion model is developed for the estimation of the performance and NOx emission of medium-sized direct-injection marine diesel engine. The developed combustion model is coupled with the commercial 1D cycle-simulation model, Boost, to analyze the entire engine system, including the intake and exhaust. The combustion model code was generated using Fortran90, and the model was coupled with Boost by connecting the generated code to a user-defined high-pressure cycle (UDHPC) interface. Simulation was performed for two injectors (8 holes and 10 holes) and two engine loads (50% and 100%), and the results of simulation were in good agreement with engine performance test.

A comparative study on the simulation of single-stage and multi-stage refrigeration cycle using propane as a refrigerant (프로판 냉매를 활용한 단일 및 다단 냉동 사이클의 전산모사 비교 연구)

  • Noh, Sanggyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3327-3335
    • /
    • 2014
  • In this study, comparison works have been performed for single-stage and multi-stage refrigeration cycle using propane as a refrigerant in order to cool down the natural gas stream. A comparative analysis has been performed for a single, two, three and four stage refrigeration cycle using propane as a refrigerant for cooling the natural gas stream. For the simulation, natural gas feedstock properties supplied by KOGAS were utilized and Peng-Robinson equation of state model was used. As the number of compression stages increase, the condenser heat duty is decreased. The refrigeration heat duty for a four-stage refrigeration cycle is decreased by 20.36% compared to that for a single-stage refrigeration cycle. Moreover, the total refrigerant circulation rate for a four-stage refrigeration system is was reduced by 14.53% compared to the single stage refrigeration cycle. The total compression power for a four-stage compression was reduced by 41.61% compared to the single stage compression.

A Study on the Development Type of Component Joint Design for Environment Friendly Multi Housing Remodeling-Living Room (I) (공동주택의 친환경 리모델링을 위한 부품접합부 개선방안의 유형화에 관한 연구(I);거실 및 침실을 중심으로)

  • Lim, Seok-Ho;Kim, Soo-Am;Hwang, Eun-Kyoung;Yun, Mae-Han
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.366-369
    • /
    • 2006
  • Multi Housing design has not considered the remodeling even at the beginning of the construction. This severely hindered systematic maintenance, providing fundamental causes of consuming society. In general, in about 20 years when the buildings become too old, they are brought down or removed with a trail of waste left behind. In addition, since the current remodeling or future remodeling type is a general remodeling that leaves only a frame, some question the role of the remodeling as a solution to the reconstruction from economically and environmentally efficient aspects. This study intends to find a solution for long-life span multi-family housing design, promoting sequential remodeling by stating the life cycle of components. Problems were identified by analyzing joints, design and construction of multi-family housing based on the previous researches. Conclusion from characterization of the design plan according to joint parts can be summarized as the following firstly, the problem of the wet was seen in joints between the structure and a finishing materials and ones between separate finishing materials. Secondly, the problem of overlap was frequently seen in joints between the structure and a door/window, ones between a door/window and a finishing materials, and ones between a finishing materials and an electrical/mechanical device.

  • PDF