• Title/Summary/Keyword: multi-beam

Search Result 1,136, Processing Time 0.027 seconds

A Study on the Architectural Characteristic Jang-Dae of Castle in the Joseon Dynasty (조선시대 성곽 장대의 건축특성에 관한 연구)

  • Kim, Ki-hyeon;Chang, Hun-duck
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.2
    • /
    • pp.120-141
    • /
    • 2015
  • This paper is a preliminary study of architectural characteristics of Jangdae (general's podium), which shows one of the technical changes in fortification of Joseon Dynasty. As a facility for commands of generals and training for officers and men, it was located inside a fortress. Although it is not certain when the first Jangdae was built, the number of them dramatically increased around 18th century. Since the top priority function of the Jangdae was the prospect, it was installed at the hilly spot with open architecture. In addition, the open structure of Eupseong fortress towers on the riverside banks could simultaneously offer the functions as viewing around and Jangdae. Since Jangdae was also a place for military drills and reviews of soldiers, a wide podium was positioned at the front to muster the soldiers. This feature was standardized in the space organization of Jangdae in Joseon, and a mere podium was installed unless the topographic restrictions allows enough space. On the other hand, as a place for a commander, the hierarchy of the Jangdae was revealed through a variety of architectural characteristics. The hierarchy was assigned to the commander's space through the altitude difference, and diverse ornaments were added to show a sense of class. The floor plan of the Jangdae building can be largely categorized into rectangle and square, and the typical sizes of the former are $5{\times}4$ Kans (traditional measuring unit between two columns) and $3{\times}2$ Kans. Out of these two types, buildings of $5{\times}4$ Kans were found in flat land and eupseong fortresses with large space, and the relatively smaller ones of $3{\times}2$ Kans in mountain fortresses. All buildings of square floor plan had $3{\times}3$ Kans style, and the center Kan was twice wider than the side Kan to make the central space wide. It seems that the purpose was to secure the interior space of the upper story because the center Kan accounts for the floor area of the upper story. Some Jangdae's had internal story to form overhead space. The multi-roofed tower style with eaves attached to the upper and lower story is found exclusively in Jangdae. The buildings shows the Onkanmulim style which extends Naejinju (inner column) of the lower story to be the Byeonju (outer column) of the upper story, and the log-framed floor in the upper floor was structured by inserting the Changbang (connecting beam) between the Naejinju's and joining the log frames. In addition, the towers in eupseong fortresses had log-framed floor in the upper floor by setting up the high Nuhaju (column underneath a roof) and joining Cheongbang to the upper part of the column while it cannot be regarded as multi-roofed because only the upper part has a roof.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Characteristics of Seafloor Morphology and Manganese Nodule Occurrence in the KODES area, NE Equatorial Pacific (태평양 한국심해환경연구(KODES) 지역 해저변 지형과 망간단괴 분포특성)

  • Jung, Hoi-Soo;Ko, Young-Tak;Chi, Sang-Bum;Kim, Hyun-Sub;Moon, Jai-Woon
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.323-337
    • /
    • 1999
  • Seafloor morphology and manganese nodule occurrence were studied in the Korea Deep-sea Environmental Study (KODES) area, northeast equatorial Pacific, to understand their relationship. Study area is composed of three elongated valleys and hills with about 100~200 m height along NNE-SSW direction. Valley region is generally flat. However, hill region is very rugged with big cliffs of about 100m height and small depressions of several tens of meters depth. Tectonic movement along the Clarion-Clipperton fracture zone, consequent formation of elongated abyssal hills and Valleys, erosion of siliceous bottom sediments by bottom currents, and dissolution of carbonate sediments on the abyssal hills below CCD result in the rugged morphology. Manganese nodule occurrence is closely related to the morphology of the study area; mostly rounded-shaped manganese nodules with about 5 cm diameter are abundant on the flat valley region, whereas irregular shaped nodules (or manganese crust) with less than 5 cm to about 1 m diameter occur on the hill. These results supports the previous reports that nodule abundance, composition, and morphology are variable both on regional and local small scales on the seafloor even within some abundant nodule provinces depending on oceanographic characteristics such as bathymetric features, surface sediment type, sediment thickness, and so on. We suggest that such oceanographic characteristics affect interrelatedly on the formation of manganese nodules, and tectonic movement of the Pacific plate ultimately constrain the nodule occurrence. A potential mining place in the KODES area seems to be the valley region, which is elongated to the NNW-SSE direction with 3-4 km width.

  • PDF

Development of B4C Thin Films for Neutron Detection (스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Cho, Sang-Jin;Choi, Young-Hyun;Park, Jong-Won;Moon, Myung Kook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • $^3He$ gas has been used for neutron monitors as the neutron converter owing to its advantages such as high sensitivity, good ${\gamma}$-discrimination capability, and long-term stability. However, $^3He$ is becoming more difficult to obtain in last few years due to a global shortage of $^3He$ gas. Accordingly, the cost of a neutron monitor using $^3He$ gas as a neutron converter is becoming more expensive. Demand on a neutron monitor using an alternative neutron conversion material is widely increased. $^{10}B$ has many advantages among various $^3He$ alternative materials, as a neutron converter. In order to develop a neutron converter using $^{10}B$ (actually $B_4C$), we calculated the optimal thickness of a neutron converter with a Monte Carlo simulation using MCNP6. In addition, a neutron converter was fabricated by the Ar sputtering method and the neutron signal detection efficiencies were measured with respect to various thicknesses of fabricated a neutron converter. Also, we developed a 2-dimensional multi-wire proportional chamber (MWPC) for neutron beam profile monitoring using the fabricated a neutron converter, and performed experiments for neutron response of the neutron monitor at the 30 MW research reactor HANARO at the Korea Atomic Energy Research Institute. The 2-dimensional MWPC with boron ($B_4C$) neutron converter was proved to be useful for neutron beam monitoring, and can be applied to other types of neutron imaging.

Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom (인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향)

  • Wang, Jihwan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.495-501
    • /
    • 2014
  • The objective of this study was to evaluate the differences and reproducibility of Hounsfield unit (HU) value and volume measurements on different computed tomography (CT) scanner types and different collimations by using a gelatin phantom. The phantom consisting of five synthetic simulated calculus spanning diameters from 3.0 mm to 12.0 mm with 100 HU was scanned using a two-channel multi-detector row CT (MDCT) scanner, a four-channel MDCT scanner, and two 64-channel MDCT scanners. For all different scanner types, the thinnest possible collimation and the second thinnest collimation was used. The HU values and volumes of the synthetic simulated calculus were independently measured three times with minimum intervals of 2 weeks and by three experienced veterinary radiologists. ANOVA and Scheff$\acute{e}$ test for the multiple comparison were performed for statistical comparison of the HU values and volumes of the synthetic simulated calculus according to different CT scanner types and different collimations. The reproducibility of the HU value and volume measurements was determined by calculating Cohen's k. The reproducibility of HU value and volume measurements was very good. HU value varied between different CT scanner types, among different beam collimations. However, there was not statistically significant difference. The percent error (PE) decreased as the collimation thickness decreased, but the decrease was statistically insignificant. In addition, no statistically significant difference in the PEs of the different CT scanner types was found. It can be concluded that the CT scanner type insignificantly affects HU value and the volumetric measurement, but that a thinner collimation tends to be more useful for accurate volumetric measurement.

Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

  • Ashamalla, Hani;Tejwani, Ajay;Parameritis, Ioannis;Swamy, Uma;Luo, Pei Ching;Guirguis, Adel;Lavaf, Amir
    • Radiation Oncology Journal
    • /
    • v.31 no.2
    • /
    • pp.104-110
    • /
    • 2013
  • Purpose: Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Materials and Methods: Sixteen patients were studied. Prostate ($PTV_P$), right pelvic ($PTV_{RtLN}$) and left pelvic lymph nodes ($PTV_{LtLN}$), and organs at risk were contoured. $PTV_P$, $PTV_{RtLN}$, and $PTV_{LtLN}$ received 50.40 Gy followed by a boost to $PTV_B$ of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose ($D_{MEAN}$) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Results: Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The $D_{MEAN}$ of bladder was within 2% of each other. The rectum $D_{MEAN}$ in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). Conclusion: For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

The Morphological Change by Slope Erosional Processes in the Dokdo Seamount (독도해산의 사면침식으로 인한 지형변화)

  • Kang, Ji-Hyun;Sung, Hyo-Hyun;Park, Chan-Hong;Kim, Chang-Hwan;Jeong, Eui-Young
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.6
    • /
    • pp.791-807
    • /
    • 2008
  • The purpose of this study is to analyze landform characteristics and geomorphic processes in Dokdo seamount. For geomorphic analysis, bathymetry data were collected by multi-beam echosounder and the seismic survey was also conducted. Through the detailed analysis of depth, slope, aspect and erosional landform, Dokdo Seamount is characterized by a flat or gently sloping top of $2^{\circ}$ or less and seamount slope with $14{\sim}40^{\circ}$ gradient. There are protrusion of landform around the Dokdo on top of the Dokdo seamount. It is inferred that the features are formed by collapsed debris deposits or remained bedrocks by differential erosion in the past. The massmovement topography including slump and slide is shown on seamount slope with $14{\sim}40^{\circ}$ gradient. In addition, gullies with various length are developed on the Dokdo seamount slope. Slope erosional processes occur more actively along the submarine gullies on the Dokdo seamount. It is inferred that the massmovement processes on the slope of Dokdo seamount are related to earthquake activities and evolution of submarine volcano. Consequently, slope of the Dokdo seamount has retreated by erosional processes of mass-movement and submarine gullies.

Development of Structure Analysis Program for Jointed Concrete Pavement Applying Load Discretization Algorithm (하중변환 알고리듬을 적용한 줄눈 콘크리트 포장해석 프로그램 개발)

  • Yun, Tae-Young;Kim, Ji-Won;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.5 no.4 s.18
    • /
    • pp.1-11
    • /
    • 2003
  • Recently, the new pavement design method considering Korean environment and the specification for improving performance of pavement are being developed in Korea. The Jointed Concrete Pavement Program Applying Load Discretization Algorithm (called HEART-JCP) is one of the results of Korea Pavement Research Project in Korea. HEART-JCP program is developed to analyze various loading condition using the load discretization algorithm without mesh refinement. In addition, it can be modified easily into multi-purpose concrete pavement nidyses program because of the modularized structure characteristic of HEART-JCP. The program consists of basic program part and load discretization part. In basic program part, the displacement and stress are computed in the concrete slab, sub-layer, and dowel bar, which are modeled with plate/shell element, spring element and beam element. In load discretization program part, load discretization algorithm that was used for the continuum solid element is modified to analyze the model with plate and shell element. The program can analyze the distributed load, concentrated load, thermal load and body load using load discretization algorithm. From the result of verification and sensitivity study, it was known that the loading position, the magnitude of load, and the thickness of slab were the major factors of concrete pavement behavior as expected. Since the result of the model developed is similar to the results of Westergaard solution and ILLISLAB, the program can be used to estimate the behavior of jointed concrete pavement reasonably.

  • PDF

Usefulness of Dual Energy CT to Improve Image Quality Degradation due to Lens Shielding (수정체 차페로 기인한 화질저하 개선을 위한 듀얼 에너지 CT의 유용성)

  • Yoon, Joon;Kim, Hyeonju
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.969-977
    • /
    • 2019
  • Applying the bismuth shield used to reduce the radiation exposure, image quality may be reduced due to beam hardening caused by the shield during CT scan. Therefore, we tried to find out the energy range that can reduce image degradation by applying GSI mode of G company's dual energy CT and examine the possibility through experiment. As a result, after bismuth shielding, 118 ± 10.6 HU and 50.1 ± 14.6 HU at 50 keV after dual-energy CT scan were the most similar to the CT value before image deterioration(p> 0.05). It was measured 176.6 ± 7.1 and 138.3 ± 1.1 at 50 keV(p> 0.05). Experiments showed that the use of the shield during CT inspection inevitably degrades the image quality, but experiments show that the GSI function of the dual energy CT can maintain the image quality even when the shield is used. If the various shields are secured after the evaluation using the dual energy CT, it is expected to overcome the disadvantages of poor image quality caused by the use of the radiation shield for reducing the exposure, which is the biggest disadvantage of the CT scan.

Slope Stability and Development of Debris Flow Deposit in the Ulleung Basin, East Sea (동해 울릉분지의 사면안정성 및 쇄설류 퇴적체의 발달)

  • Lee, Sun-Jong;Lee, Jeong-Min;Yoo, Dong-Geun;Lee, Go-Eun;Park, Soo-Chul
    • Economic and Environmental Geology
    • /
    • v.50 no.2
    • /
    • pp.129-143
    • /
    • 2017
  • The shallow sediments in the southwestern Ulleung Basin consist of mass flow deposits such as slide/slump and debris flow deposits (DFD), caused by slope failure. These sediments are proven to be important in studying geological disaster and stability of the seafloor. In this paper, we analysised the flow accumulation and slope failure susceptibility of the Ulleung Basin on the basis of multi-beam data, collected in this area. We also studied the distribution pattern and the seismic characteristics of the DFD in the uppermost layer of the Ulleung Basin on the basis of seismic data. The slope susceptibility was calculated as the frequency ratio of each factors including slope, aspect, curvature and stream power index (SPI), which causes the slope failure. These results indicate that the slope failure is frequently to occur in the southern and western continental slope of the Ulleung Basin. The sediment flow (mass flow) caused by the slope failure converges to the north and northwest of the Ulleung Basin. According to the seismic characteristics, the uppermost layer in study area can be divided into four sedimentary unit. These sedimentary units develop from the south and southwest to the north and northwest in association with slope susceptibility and flow accumulation.