• Title/Summary/Keyword: mpy

Search Result 20, Processing Time 0.033 seconds

Microstructural, mechanical, and electrochemical analysis of carbon doped AISI carbon steels

  • Muhammad Ishtiaq;Aqil Inam;Saurabh Tiwari;Jae Bok Seol
    • Applied Microscopy
    • /
    • v.52
    • /
    • pp.10.1-10.15
    • /
    • 2022
  • The effect of carbon doping contents on the microstructure, hardness, and corrosion properties of heat-treated AISI steel grades of plain carbon steel was investigated in this study. Various microstructures including coarse ferrite-pearlite, fine ferrite-pearlite, martensite, and bainite were developed by different heat treatments i.e. annealing, normalizing, quenching, and austempering, respectively. The developed microstructures, micro-hardness, and corrosion properties were investigated by a light optical microscope, scanning electron microscope, electromechanical (Vickers Hardness tester), and electrochemical (Gamry Potentiostat) equipment, respectively. The highest corrosion rates were observed in bainitic microstructures (2.68-12.12 mpy), whereas the lowest were found in the fine ferritic-pearlitic microstructures (1.57-6.36 mpy). A direct correlation has been observed between carbon concentration and corrosion rate, i.e. carbon content resulted in an increase in corrosion rate (2.37 mpy for AISI 1020 to 9.67 mpy for AISI 1050 in annealed condition).

Area Effect on Galvanic Corrosion of Condenser Materials with Titanium Tubes in Nuclear Power Plants (Titanium 전열관을 사용하는 원전 복수기 재료의 Galvanic Corrosion에 미치는 면적의 영향)

  • Hwang, Seong-Sik;Kim, Joung-Soo;Kim, Uh-Chul
    • Nuclear Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.507-514
    • /
    • 1993
  • Titanium tubes have recently been used in condensers of nuclear power plants since titanium has very good corrosion resistance to seawater. However, when it is connected to Cu alloys as tube sheet materials and these Cu alloys are connected to carbon steels as water box materials, it makes significant galvanic corrosion on connected materials. It is expected from electrochemical tests that the corrosion rate of carbon steel will increase when it is galvanically coupled with Ti or Cu in sea water and the corrosion rate of Cu will increase when it is coupled with Ti, if this couple is exposed to sea water for a long time. It is also expected that the surface area ratios, R$_1$(surface area of carbon steel/surface area of Ti) and R$_2$(surface area of carbon steel/surface area of Cu) are very important for the galvanic corrosion of carbon steel and that these should not be kept to low values in order to minimize the galvanic corrosion on the carbon steel of the water box. Immersed galvanic corrosion tests show that the corrosion rate of carbon steel is 4.4 mpy when the ratio of surface area of Fe/ surface area of Al Brass is 1 while it is 570 mpy when this ratio is 10$^{-2}$ . The galvanic corrosion rate of this carbon steel is increased from 4.4 mpy to 13 mpy at this area ratio, 1, when this connected galvanic specimen is galvanically coupled with a Ti tube. This can be rationalized by the combined effects of R$_1$ and R$_2$ on the polarization curve.

  • PDF

Study of Corrosion of Brass Coated Steel Cords in the Acetonitrile Solution of Sulfenamide Derivatives by Tafel Plot and AC Impedance Measurements

  • Young Chun Ko;Byung Ho Park;Hae Jin Kim;Q Won Choi;Jongbaik Ree;Keun Ho Chung
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.2
    • /
    • pp.122-126
    • /
    • 1994
  • Corrosion of brass coated steel cords in the acetonitrile solution of sulfenamide derivatives, N-Cyclohexylbenzothiazole-2-sulfenamide (CBTS), N,N'-Dicyclohexylbenzothiazole-2-sulfenamide (DCBS), N-tert-Butylbenzothiazole-2-sulfenamide (TBBS), N-tert-Amylbenzothiazole-2-sulfenamide (TABS), and N-Oxydiethylbenzothiazole-2-sulfenamide (OBTS) was investigated by potentiostatic anodic and cathodic polarization (Tafel plot), DC polarization resistance, and AC impedance measurements. The corrosion current densities and rates are 1.236 ${\mu}A /cm^2$ and 0.655 MPY for CBTS; 1.881 ${\mu}A/cm^2$ and 0.988 MPY for DCBS; 2.367 ${\mu}A/cm^2$ and 1.257 MPY for TBBS; 3.398 ${\mu}A /cm^2$ and 1.809 MPY for TABS, respectively. OBTS among derivatives under study shows the lowest corrosion density (0.546 ${\mu}A /cm^2$) and the slowest corrosion rate (0.288 MPY). Also, the charge transfer resistances and the double layer capacitances are 275.21 $k{\Omega}{\cdot}cm^2$ and 7.0 ${\mu}F{cdot}cm^{-2}$ for CBTS; 14.24 ${\mu}F{\cdot}cm^2$ and 26 ${\mu}F{\cdot}cm^{-2}$ for DCBS; 54.15 $k{\Omega}{\cdot}cm^2$ and 26 ${\mu}F{\cdot}cm^{-2}$ for TBBS; 0.96$k{\Omega}{\cdot}cm^2$ and 83 ${\mu}F{\cdot}cm^{-2}$ for TABS, respectively. The weaker the electron donating inductive effect of derivatives is and the smaller the effect of steric hindrance is, the more the corrosion of brass coated steel cords in the acetonitrile solution of sulfenamide derivatives is prevented. The above results agree with that observed in the field of tire industry.

A Study on the Effect of Non-Clean Water Treatment Chemicals for R-134a Turbo-Chiller Condensers (R-134a 터보냉동기 응축기의 무세정 수처리 약품 효과 연구)

  • JUNG, DA-WOON;KIM, MAN-HOE
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.4
    • /
    • pp.437-445
    • /
    • 2022
  • This paper presents an experimental study on the main management factors of the condenser contamination such as fouling and corrosion for the R-134a turbo-chiller to save energy, reduce corrosion rates, and reduce maintenance costs through the application of condenser non-cleaning water treatment chemical. The series of experiment is conducted using combining oxidative microbial sterilizers, non-oxidizing microbial sterilizers, and anti-corrosion agents. The leaving temperature difference and corrosion rates for three different combination of chemicals are collected and analyzed. The experimental results show that the cost reduction (4,066,000 Won/year) of the disinfectant (FT-830) can be achieved by adding the oxidative disinfectant (NaOCl) and the non-oxidizing disinfectant (NX-1116). The LTD value is maintained at 1.9℃, and the corrosion rates of copper and carbon steel specimens are 0.07 mpy and 1.61 mpy, respectively.

NMR Study on Binding Interactions of Cationic Porphyrin Derivatives with double helical $d(CGCGAATTCGCG)_2$

  • Huh, Sungho;Hong, Seokjoo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.5 no.2
    • /
    • pp.118-129
    • /
    • 2001
  • Binding interactions of cationic porphyrins, T4MPyP and TMAP with DNA oligomer d(CGCGAATTCGCG), were studied with NMR spectroscopy, W and CD spectroscopic method. Two porphyrins showed significant differences in NMR, UV and CD data upon binding to DNA. T4MPyP was considered to position more closely to DNA bases through partial intercalation as well as ionic intercalation between the positive charges of porphyrin and phosphate group of DNA at 5’-GC-3’steps. Contrast to this, TMAP was thought to bind to phosphate of DNA more or less outside of the groove.

  • PDF

Evaluation Frequency of Merkel Cell Polyoma, Epstein-Barr and Mouse Mammary Tumor Viruses in Patients with Breast Cancer in Kerman, Southeast of Iran

  • Reza, Malekpour Afshar;Reza, Mollaie Hamid;Mahdiyeh, Lashkarizadeh;Mehdi, Fazlalipour;Hamid, Zeinali Nejad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7351-7357
    • /
    • 2015
  • Breast cancer is the most common cancer among women worldwide. Roles of the Epstein-Barr, Merkel cell polyoma and mouse mammary tumor viruses in breast carcinogenesis are still controversial although any relationship would clearly be important for breast cancer etiology, early detection and prevention. In the present study associations between EBV, MMTV and Merkel cell polyoma virus and breast cancer in 100 Iranian patients were evaluated using paraffin-embedded tissues. EBER RNA and expression of p53 and large T antigen were evaluated by real time PCR and CD34, p63, HER2, PR and ER markers were studied by immunohistochemistry. EBV was detected in 8/100 (8%), MMTV in 12/100 (12%), MPy in 3/100 (3%) and EBER RNA in 18/100 (18%) cases. None of the control samples demonstrated any of the viruses. p53 was suppressed in EBV, MPy and MMTV positive samples. The large T antigen rate was raised in MPy positive samples. Our results showed that EBV, MMTV and the Merkel cell polyoma virus are foundwith some proportion of breast cancers in our patients, suggesting that these viruses might have a significant role in breast cancer in Kerman, southeast of Iran.

Meta-analysis of factors affecting milk component yields in dairy cattle

  • Lee, Junsung;Seo, Jakyeom;Lee, Se Young;Ki, Kwang Seok;Seo, Seongwon
    • Journal of Animal Science and Technology
    • /
    • v.56 no.2
    • /
    • pp.5.1-5.5
    • /
    • 2014
  • The objectives of this study were thus to identify most significant factors that determine milk component yield (MCY) using a meta-analysis and, if possible, to develop equations to predict MCY using variables that can be easily measured in the field. A literature database was constructed based on the research articles published in the Journal of Dairy Science from Oct., 2007 till May, 2010. The database consisted of a total of 442 observed means for MCY from 118 studies. The candidate factors that determine MCY were those which can be routinely measured in the field (e.g. DMI, BW, dietary forage content, chemical composition of diets). Using a simple linear regression, the best equations for predicting milk fat yield(MFY) and milk protein yield (MPY) were $MFY=0.351({\pm}0.068)+0.038({\pm}0.003)$ DMI ($R^2=0.27$), and $MPY=0.552({\pm}0.071)+0.031({\pm}0.002)DMI-0.004({\pm}0.001)$ FpDM (%, forage as a percentage of dietary DM) ($R^2=0.38$), respectively. The best equation for predicting milk fat content (%) explained only 12% of variations in milk fat content, and none of a single variable can explain more than 5% of variations in milk protein content. We concluded that among the tested variables, DMI was the only significant factor that affects MFY and both DMI and FpDM significantly affect MPY. However, predictability of linear equations was relatively low. Further studies are needed to identify other variables that can predict milk component yield more accurately.

The Assessments of Integrity of SA516 Gr.70 Material for the 60 days Exposure in over 40% Relative Humidity Environments (상대습도 40%이상 환경에서 SA516 Gr.70 재료의 장기간 노출에 따른 건전성 평가)

  • Gwon, Hyeok-Cheol;Lee, Du-Ho;Seong, Gi-Bang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.193-194
    • /
    • 2014
  • 원전은 고온기능시험 이후 2차계통 내부를 상대습도 40%이하로 관리하여 계통 재질 부식을 최소화하고 있다. 일반적으로 발전소에서는 운전 정지 후 상대습도 40%이하로 낮추는데 15일정도 소요되지만, 발전소 계통 중 일부 곡관부위는 약 60일정도 소요된다. 본 연구는 일부 계통 재료가 상대습도 제한치(<40%) 이상의 환경에서 장기간(최대 60일) 노출시 재료 건전성에 미치는 영향 평가이다. 평가를 위해 시편의 실험 전, 후 무게변화를 이용한 부식률 측정과 표면분석을 위해 광학현미경을 이용하였다. 사용 시편의 재료는 SA516 Gr.70이며 표면상태를 인위적으로 산화피막을 생성 시킨 것(2개)과 산화피막이 없는 것(6개)으로 2종류로 제작하였다. 총 시험기간은 60일이고 시험기간 중 산화피막이 없는 시편은 7일, 21일, 60일에 시편을 2개씩 꺼내어 무게를 측정하여 부식률을 계산하였다. 실험결과, 산화피막이 없는 시편은 노출되는 시간에 따라 부식률이 각각 0.35(7일), 0.21(21일), 0.67(60일) mpy이었고 산화피막이 있는 시편은 0.06(60일) mpy였다. 산화표면 분석결과, 산화피막이 없는 시편은 노출되는 시간에 관계없이 물방울이 맺힌 부분에 pitting을 확인하였다. 하지만, 산화피막이 있는 시편은 pitting의 흔적은 없었다. 산화피막이 없는 시편의 경우 시간에 따라 부식률은 높아지지만 학계에서 통용되는 뛰어난 내부식성 재료의 부식률 기준인 < 1 mpy이하기 때문에 재료 건전성에 미치는 영향은 거의 없을 것으로 판단된다. 또한, 대부분 원전의 경우 고온기능시험 또는 운전기간 동안에 2차계통 구성 재료 표면에 산화막이 생성되었기 때문에 산화피막이 있는 시편의 결과로 판단하면 상대습도 40%이상에 60일 이상 노출되어도 부식은 거의 일어나지 않았을 것으로 사료된다. 실증실험결과를 가지고 종합적으로 평가하면 상대습도 40%이상 환경에서 곡관부위가 60일이상 노출되어도 재료 건전성에 미치는 영향은 거의 없을 것으로 판단된다.

  • PDF

Development of High Erosion Resistant Fe-based Alloy for Continuous Hot Dipping Line (연속용융 도금라인 용 고내침식 Fe계 합금 개발)

  • Baek, Min-Sook;Kim, Yong-Cheol;Baek, Kyeong-Cheol;Kwak, Joon-Seop;Yoon, Dong-Joo
    • Journal of Surface Science and Engineering
    • /
    • v.53 no.3
    • /
    • pp.95-103
    • /
    • 2020
  • In this study, the material used in the hot dip galvanizing equipment was poorly corrosion-resistant, so it was performed to solve the cost and time problems caused by equipment replacement. The theoretical calculation was performed using the DV-Xα method(Discrete Variational Local-density approximation method). The alloy (STS4XX series) of the equipment currently used has a martensite phase. Therefore, the theoretical calculation was performed by applying P4 / mmm, which is a tetragonal structure. The new alloy was chosen by designing theoretical values close to existing materials. Considering elements that contribute to corrosion, most have high prices. Therefore, the design was completed by adjusting the content using only the components of the reference material in the theoretical design. The final design alloys were chosen as D6 and D9. Designed D6 and D9 were dissolved and prepared using an induction furnace. After the heat treatment process was completed, the corrosion rate of the alloys was confirmed by using the potentiodynamic polarization test. The surface of the prepared alloys were processed horizontally and then polished to # 1200 using sand paper to perform potentiodynamic polarization test. Domestic products: 4.735 mpy (mils / year), D6: 0.9166 mpy, D9: 0.3372 mpy, alloys designed than domestic products had a lower corrosion rate. Therefore, the designed alloy was expected to have better erosion resistance.

Public Exposure to Natural Radiation and the Associated Increased Risk of Lung Cancer in the Betare-Oya Gold Mining Areas, Eastern Cameroon

  • Joseph Emmanuel Ndjana Nkoulou II;Louis Ngoa Engola;Guy Blanchard Dallou;Saidou;Daniel Bongue;Masahiro Hosoda;Moise Godefroy Kwato Njock;Shinji Tokonami
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.59-67
    • /
    • 2023
  • Background: This study aims to reevaluate natural radiation exposure, following up on our previous study conducted in 2019, and to assess the associated risk of lung cancer to the public residing in the gold mining areas of Betare-Oya, east Cameroon, and its vicinity. Materials and Methods: Gamma-ray spectra collected using a 7.62 cm×7.62 cm in NaI(Tl) scintillation spectrometer during a car-borne survey, in situ measurements and laboratory measurements performed in previous studies were used to determine the outdoor absorbed dose rate in air to evaluate the annual external dose inhaled by the public. For determining internal exposure, radon gas concentrations were measured and used to estimate the inhalation dose while considering the inhalation of radon and its decay products. Results and Discussion: The mean value of the laboratory-measured outdoor gamma dose rate was 47 nGy/hr, which agrees with our previous results (44 nGy/hr) recorded through direct measurements (in situ and car-borne survey). The resulting annual external dose (0.29±0.09 mSv/yr) obtained is similar to that of the previous study (0.33±0.03 mSv/yr). The total inhalation dose resulting from radon isotopes and their decay products ranged between 1.96 and 9.63 mSv/yr with an arithmetic mean of 3.95±1.65 mSv/yr. The resulting excess lung cancer risk was estimated; it ranged from 62 to 216 excess deaths per million persons per year (MPY), 81 to 243 excess deaths per MPY, or 135 excess deaths per MPY, based on whether risk factors reported by the U.S. Environmental Protection Agency, United Nations Scientific Committee on the effects of Atomic Radiation, or International Commission on Radiological Protection were used, respectively. These values are more than double the world average values reported by the same agencies. Conclusion: There is an elevated level of risk of lung cancer from indoor radon in locations close to the Betare-Oya gold mining region in east Cameroon. Therefore, educating the public on the harmful effects of radon exposure and considering some remedial actions for protection against radon and its progenies is necessary.