Study for improvement of grounds subjected to cyclic loads

  • Mittal, Satyendra;Meyase, Kenisevi
    • Geomechanics and Engineering
    • /
    • 제4권3호
    • /
    • pp.191-208
    • /
    • 2012
  • Due to rapid industrialisation, large scale infrastructure development is taking place worldwide. This includes railways, high speed highways, elevated roads etc. To meet the demands of society and industry, many innovative techniques and materials are being developed. In developed nations like USA, Japan etc. for railways applications, new material like geocells, geogrids are being used successfully to enable fast movement of vehicles. The present research work was aimed to develop design methodologies for improvement of grounds subjected to cyclic loads caused by moving vehicles on roads, rail tracks etc. Deformation behavior of ballast under static and cyclic load tests was studied based on square footing test. The paper presents a study of the effect of geo-synthetic reinforcement on the (cumulative) plastic settlement, of point loaded square footing on a thick layer of granular base overlying different compressible bases. The research findings showed that inclusion of geo-synthetics significantly improves the performance of ballasted tracks and reduces the foundation area. If the area is kept same, higher speed trains can be allowed to pass through the same track with insertion of geosynthetics. Similarly, area of machine foundation may also be reduced where geosynthetics is provided in foundation. The model tests results have been validated by numerical modeling, using $FLAC^{3D}$.

압광 페인트를 이용한 콘크리트 파괴시험시 골재크기가 균열성상에 미치는 영향조사 (Investigation of Aggregate Size Effect on Cracking Behavior in Concrete Fracture Test using Mechanoluminescent Paint)

  • 이창준;김화중;김지식;전기용
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.93-98
    • /
    • 2012
  • In order to capture the fast crack propagation in an unmanipulated concrete fracture test, we employed mechanoluminascent(ML) material, which emits visible light when stressed, as a crack visualization tool. Three-point bending fracture test setup, a paint type ML material and a high speed camera were used to capture the images of fast moving cracks. The maximum size of coarse aggregates of concrete was used as an experimental parameter. The crack images, loading, and crack mouth opening displacement were successfully recorded as a function of time elapsed. From the test results, several interesting cracking behavior in the unmanipulated fracture test was observed in such that (1) the crack moves fast while the load is slowly decreased after the maximum loading, and (2) the crack in concrete with larger coarse aggregates moves faster than the others.

50KW 터보제너레이터용 가스터빈 엔진의 설계점/ 탈설계/과도성능해석 (On/Off-Design/Transient Analysis of a 50KW Turbogenerator Gas Turbine Engine)

  • 김수용;박무룡;조수용
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.87-99
    • /
    • 1997
  • Present paper describes on/off design performance of a 50KW turbogenerator gas turbine engine for hybrid vehicle application. For optimum design point selection, relevant parameter study is carried out. The turbogenerator gas turbine engine for a hybrid vehicle is expected to be designed for maximum fuel economy, ultra low emissions, and very low cost. Compressor, combustor, turbine, and permanent-magnet generator will be mounted on a single high speed (82,000 rpm) shaft that will be supported on air bearings. As the generator is built into the shaft, gearbox and other moving parts become unnecessary and thus will increase the system's reliability and reduce the manufacturing cost. The engine has a radial compressor and turbine with design point pressure ratio of 4.0. This pressure ratio was set based on calculation of specific fuel consumption and specific power variation with pressure ratio. For the given turbine inlet temperature, a rather conservative value of $1100^\circK$ was selected. Designed mass flow rate was 0.5 kg/sec. Parametric study of the cycle indicates that specific work and efficiency increase at a given pressure ratio and turbine inlet temperature. Off design analysis shows that the gas turbine system reaches self operating condition at N/$N_{DP}$ = 0.53. Bleeding air for turbine stator cooling is omitted considering low TIT and for a simple geometric structure. Various engine performance simulations including, ambient temperature influence, surging at part load condition. Transient analysis were performed to secure the optimum engine operating characteristics. Surge margin throughout the performance analysis were maintained to be over 80% approximately. Validation of present results are yet to be seen as the performance tests are scheduled by the end of 1998 for comparison.

  • PDF

고강도 콘크리트의 부착거동에 관한 실험적 연구 (The Experimental Study on the Bond behavior of High strength concrete)

  • 이준구;김우;박광수;김대중;이응찬;김한중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.774-780
    • /
    • 1999
  • The study of bond behavior between concrete and rebar has been performed for a long time. On this study, we tried to analysed variation of bond behaviors quantitatively with varying the strength of concrete. Bond stress which observed below the neutral surface of beam and at connecting part of beam and column is affected by various bond parameters. Resistance of deformed bars which embedded in concrete to the pullout force is divided 1) chemical adhesive force 2) frictional force 3) mechanical resistance of ribs to the concrete and these horizontal components of resistance is being bond strength. We selected the most common and typical variable which is concrete strength among various variables. So we used two kinds of concrete strength like as 25MPa(NSC) and 65MPa(HSC). Tension Test was performed to verify how bond behavior varied with two kinds of concrete strength. Concentration of bond stress was observed at load-end commonly in Tension Test of the initial load stage. At this stage stress distribution was almost coincident at each strength. As tension load added, this stress distribution had difference gradually and movement of pick point of bond stress to free-end and central section was observed. This tendency was observed at first and moving speed was more fast in NSC. At the preceeding result the reason of this phenomenon is considered to discretion of chemical adhesion and local failure of concrete around rebar in load-end direction. Especially, when concrete strength was increased 2.6 times in tension test, ultimate bond strength was increased 1.45 times. In most recent used building codes, bond strength is proportioned to sqare root of concrete compressive strength but comparison of normalized ultimate bond strength was considered that the higher concrete strength is, the lower safety factor of bond strength is in each strength if we use existing building codes. In Tension Test, in case of initial tensile force state, steel tensile stress of central cross section is not different greatly at each strength but tensile force increasing, that of central cross section in NSC was increased remarkably. Namely, tensile force which was shared in concrete in HSC was far greater than that of concrete in NSC at central section.

  • PDF

열차 증속에 따른 콘크리트 궤도 노반의 동적 응력 변화 (Dynamic Change of Stresses in Subsoil under Concrete Slab Track Subjected to Increasing Train Speeds)

  • 이태희;최찬용;;정영훈
    • 한국지반공학회논문집
    • /
    • 제29권10호
    • /
    • pp.57-66
    • /
    • 2013
  • 보다 빠른 교통 수단에 대한 사회적 관심이 현재 운영 중인 KTX의 운행속도인 350km/h을 넘어서는 고속 열차의 운행을 요구하고 있다. 본 연구에서는 콘크리트 궤도 구조물에서 열차 속도 변화에 따른 노반 변위의 변화양상을 추적하고 비선형적인 노반 응력 변화를 살펴보기 위해 유한요소해석을 실시하였다. 궤도-차량 상호작용을 간단한 형태로 고려하기 위해 이동 하중의 질점 시스템을 개발하였다. 열차 하중의 이동 속도를 100km/h에서 700km/h까지 변화시켜 결과를 얻었다. 열차 속도 증가에 따라 레일과 노반 변위는 비선형적으로 증가하였으나 뚜렷한 임계 속도 효과는 나타나지 않았다. 낮은 열차 속도 대역에서는 열차 속도보다 노반에서 에너지를 전달하는 탄성파 속도가 빠르다. 하지만 400km/h 이상의 열차 속도 대역에서는 열차 속도와 에너지 전달 속도가 거의 일치하였다. 열차 속도 증가에 따라 노반 응력 이력이 크게 변하며 경로 의존적인 토질 재료에서 상당한 크기의 소성 변형률이 예상된다.