• Title/Summary/Keyword: movement time

Search Result 3,689, Processing Time 0.032 seconds

Three-dimensional human activity recognition by forming a movement polygon using posture skeletal data from depth sensor

  • Vishwakarma, Dinesh Kumar;Jain, Konark
    • ETRI Journal
    • /
    • v.44 no.2
    • /
    • pp.286-299
    • /
    • 2022
  • Human activity recognition in real time is a challenging task. Recently, a plethora of studies has been proposed using deep learning architectures. The implementation of these architectures requires the high computing power of the machine and a massive database. However, handcrafted features-based machine learning models need less computing power and very accurate where features are effectively extracted. In this study, we propose a handcrafted model based on three-dimensional sequential skeleton data. The human body skeleton movement over a frame is computed through joint positions in a frame. The joints of these skeletal frames are projected into two-dimensional space, forming a "movement polygon." These polygons are further transformed into a one-dimensional space by computing amplitudes at different angles from the centroid of polygons. The feature vector is formed by the sampling of these amplitudes at different angles. The performance of the algorithm is evaluated using a support vector machine on four public datasets: MSR Action3D, Berkeley MHAD, TST Fall Detection, and NTU-RGB+D, and the highest accuracies achieved on these datasets are 94.13%, 93.34%, 95.7%, and 86.8%, respectively. These accuracies are compared with similar state-of-the-art and show superior performance.

A new experimental protocol to quantitatively assess the motor control capability of low-back pain patinents during dynamic trunk movement

  • Kim, J.Y.
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.156-163
    • /
    • 1995
  • An experimental protocol was developed and tested in this study in order to quantify the motor control capability of the trunk movement for both healthy subjects and low-back pain (LBP) patients. Information processing capacity (bits/second) (Fitts, 1954) and dynamic motor perfor- mance such as flexion/extension velocity and acceleration were measured as motor control parameters under the controlled range of motion (ROM). In this study, the original experimental propocol (Kim et al., 1993, 1994) was re-designed to reduce the length of the test via a series of statistical analyses for clinical application. The accuracy of the shortened protocol was statistically examined and indicated no difference conpared to the original protocol in terms of evaluating information processing capacity. This protocol was also tested among ten healthy subjects and ten LBP patients for validation purpose. The results showed that the information processing capacity was not significantly diffenent between two groups due to the large variation although there was an apparent mean difference. Average movement time showed a significant increase in LBP patients com- pared to healthy subjects. In conclusion, it was found that the new short experimental protocol could quantify the motor control capability of neuromuscular system of the trunk and also showed the applicability to patient population.

  • PDF

The role of nanotechnology in reducing the impact on the ball and increasing the speed of its movement

  • Yongyong Wang;Qixia Jia;Tingting Deng
    • Geomechanics and Engineering
    • /
    • v.32 no.5
    • /
    • pp.463-474
    • /
    • 2023
  • Materials produced with the help of new technology are used in the design of materials used in all science and engineering departments today. A sports engineering and sports equipment department is one of these departments. The use of nanotechnology in sports equipment is one of the most popular uses of this technology today. Nanomaterials have been used in sports equipment for many years, and reputable companies have benefited. Athletes' equipment allows them to display their skills to the fullest extent. It has always been a dream of professional athletes and their coaches to have unique equipment. As a result, engineers have spent all their time and effort solving this problem. Science and engineering can do various things to meet the needs of all sports levels, including specific and detailed designs, the use of appropriate materials, and standardization tests on equipment. However, these aspects must remain aligned with the latest technologies as they develop, just as with other sciences. These technologies, especially nanotechnology, are essential to sports equipment and devices developed today by sports engineers. This article examines the balls that use nanotechnology and can also improve the athlete's performance by using this technology in a specific structure. Using nanotechnology to make nanocomposite poly-hope balls, which makes them lighter and more acceptable, reduces the impact on the ball and increases its movement speed.

Comparison of the Changes in the Activation of the Quadriceps Muscle based on the Plantar Flexion Degree of the Ankle Joint in Healthy Young Females during the Stand-to-Sit movement

  • Sung-Min Son
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.2
    • /
    • pp.53-57
    • /
    • 2023
  • Purpose: The purpose of this study was to compare the changes in the muscle activation of the quadriceps muscle (rectus femoris, vastus lateralis, vastus medialis) during the stand-to-sit (StandTS) movement according to the plantar flexion angle of the ankle joint. Methods: A total of 22 healthy young females participated in this study. During the StandTS under the three conditions (plantarflexion angle 0°, 20°, and 45° of the ankle), electromyography (EMG) data (% maximum voluntary iso¬metric contraction) of the rectus femoris, vastus lateralis, and vastus medialis were recorded using a wireless surface EMG system. Results: There was a significant difference in the muscle activation of rectus femoris, vastus lateralis, and vastus medialis according to the plantar flexion angle (0°, 20°, and 45°) of the ankle. The muscle activation of the quadriceps was the highest at a 45° angle of plantarflexion and the lowest at 0°. One-way repeated ANOVA was used to analyze the muscle activation data of the lower extremity muscles according to the angle of the ankle joint. Conclusion: Based on the results of our study, it was confirmed that the muscle activity of the quadriceps can be increased even in the StandTS movement, which involves the eccentric contraction of the quadriceps muscle. This suggests that maintaining a plantar flexion posture for a long time, say by wearing high-heeled shoes, can quickly cause muscle fatigue in the lower-limb muscles, which can cause a decrease in balance ability leading to falls.

A Study on Movement of the Free Face During Bench Blasting (전방 자유면의 암반 이동에 관한 연구)

  • Lee, Ki-Keun;Kim, Gab-Soo;Yang, Kuk-Jung;Kang, Dae-Woo;Hur, Won-Ho
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.29-42
    • /
    • 2012
  • Variables influencing the free face movement due to rock blasting include the physical and mechanical properties, in particular the discontinuity characteristics, explosive type, charge weight, burden, blast-hole spacing, delay time between blast-holes or rows, stemming conditions. These variables also affects the blast vibration, air blast and size of fragmentation. For the design of surface blasting, the priority is given to the safety of nearby buildings. Therefore, blast vibration has to be controlled by analyzing the free face movement at the surface blasting sites and also blasting operation needs to be optimized to improve the fragmentation size. High-speed digital image analysis enables the analyses of the initial movement of free face of rock, stemming optimality, fragment trajectory, face movement direction and velocity as well as the optimal detonator initiation system. Even though The high-speed image analysis technique has been widely used in foreign countries, its applications can hardly be found in Korea. This thesis aims at carrying out a fundamental study for optimizing the blast design and evaluation using the high-speed digital image analysis. A series of experimentation were performed at two large surface blasting sites with the rock type of shale and granite, respectively. Emulsion and ANFO were the explosives used for the study. Based on the digital images analysis, displacement and velocity of the free face were scrutinized along with the analysis fragment size distribution. In addition, AUTODYN, 2-D FEM model, was applied to simulate detonation pressure, detonation velocity, response time for the initiation of the free face movement and face movement shape. The result show that regardless of the rock type, due to the displacement and the movement velocity have the maximum near the center of charged section the free face becomes curved like a bow. Compared with ANFO, the cases with Emulsion result in larger detonation pressure and velocity and faster reaction for the displacement initiation.

A Study of the Reactive Movement Synchronization for Analysis of Group Flow (그룹 몰입도 판단을 위한 움직임 동기화 연구)

  • Ryu, Joon Mo;Park, Seung-Bo;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.1
    • /
    • pp.79-94
    • /
    • 2013
  • Recently, the high value added business is steadily growing in the culture and art area. To generated high value from a performance, the satisfaction of audience is necessary. The flow in a critical factor for satisfaction, and it should be induced from audience and measures. To evaluate interest and emotion of audience on contents, producers or investors need a kind of index for the measurement of the flow. But it is neither easy to define the flow quantitatively, nor to collect audience's reaction immediately. The previous studies of the group flow were evaluated by the sum of the average value of each person's reaction. The flow or "good feeling" from each audience was extracted from his face, especially, the change of his (or her) expression and body movement. But it was not easy to handle the large amount of real-time data from each sensor signals. And also it was difficult to set experimental devices, in terms of economic and environmental problems. Because, all participants should have their own personal sensor to check their physical signal. Also each camera should be located in front of their head to catch their looks. Therefore we need more simple system to analyze group flow. This study provides the method for measurement of audiences flow with group synchronization at same time and place. To measure the synchronization, we made real-time processing system using the Differential Image and Group Emotion Analysis (GEA) system. Differential Image was obtained from camera and by the previous frame was subtracted from present frame. So the movement variation on audience's reaction was obtained. And then we developed a program, GEX(Group Emotion Analysis), for flow judgment model. After the measurement of the audience's reaction, the synchronization is divided as Dynamic State Synchronization and Static State Synchronization. The Dynamic State Synchronization accompanies audience's active reaction, while the Static State Synchronization means to movement of audience. The Dynamic State Synchronization can be caused by the audience's surprise action such as scary, creepy or reversal scene. And the Static State Synchronization was triggered by impressed or sad scene. Therefore we showed them several short movies containing various scenes mentioned previously. And these kind of scenes made them sad, clap, and creepy, etc. To check the movement of audience, we defined the critical point, ${\alpha}$and ${\beta}$. Dynamic State Synchronization was meaningful when the movement value was over critical point ${\beta}$, while Static State Synchronization was effective under critical point ${\alpha}$. ${\beta}$ is made by audience' clapping movement of 10 teams in stead of using average number of movement. After checking the reactive movement of audience, the percentage(%) ratio was calculated from the division of "people having reaction" by "total people". Total 37 teams were made in "2012 Seoul DMC Culture Open" and they involved the experiments. First, they followed induction to clap by staff. Second, basic scene for neutralize emotion of audience. Third, flow scene was displayed to audience. Forth, the reversal scene was introduced. And then 24 teams of them were provided with amuse and creepy scenes. And the other 10 teams were exposed with the sad scene. There were clapping and laughing action of audience on the amuse scene with shaking their head or hid with closing eyes. And also the sad or touching scene made them silent. If the results were over about 80%, the group could be judged as the synchronization and the flow were achieved. As a result, the audience showed similar reactions about similar stimulation at same time and place. Once we get an additional normalization and experiment, we can obtain find the flow factor through the synchronization on a much bigger group and this should be useful for planning contents.

DEVELOPMENT OF NANO-FLUID MOVEMENT MEASURING DEVICE AND ITS APPLICATION TO HYDRODYNAMIC ANALYSIS OF DENTINAL FLUID (미세 물 흐름 측정장치의 개발과 상아세관액의 수력학에의 응용)

  • Lee, In-Bog;Kim, Min-Ho;Kim, Sun-Young;Chang, Ju-Hea;Cho, Byung-Hoon;Son, Ho-Hyun;Back, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • This study was aimed to develop an instrument for real-time measurement of fluid conductance and to investigate the hydrodynamics of dentinal fluid. The instrument consisted of three parts; (1) a glass capillary and a photo sensor for detection of fluid movement, (2) a servo-motor, a lead screw and a ball nut for tracking of fluid movement, (3) a rotary encoder and software for data processing. To observe the blocking effect of dentinal fluid movement, oxalate gel and self-etch adhesive agent were used. BisBlock (Bisco) and Clearfil SE Bond (Kuraray) were applied to the occlusal dentin surface of extracted human teeth. Using this new device, the fluid movement was measured and compared between before and after each agent was applied. The instrument was able to measure dentinal fluid movement with a high resolution (0.196 nL) and the flow occurred with a rate of 0.84 to 15.2 nL/s before treatment. After BisBlock or Clearfil SE Bond was used, the fluid movement was decreased by 39.8 to 89.6%.

Separation of Follicular Fluid Components Stimulating Sperm Migration with Chromatographic Paper, $=mu$RPC and Superose Columns (Chromatography용 Paper, $\mu$RPC Column 및 Superose Column을 이용한 정자의 이동을 자극하는 난포액 성분의 분리)

  • 박영식
    • Journal of Embryo Transfer
    • /
    • v.13 no.3
    • /
    • pp.301-312
    • /
    • 1998
  • To efficiently separate a protein stimulating sperm swim-up migration and movement from follicular proteins, the effect of paper chromatography and liquid chromatography with reverse phase column and superose column on protein separation was examined. And the results obtained were as follows; 1. The band component that was separated with paper chromatography stimulated sperm migration and movement depending on its additional levels. Especially, band I component significantly increased sperm migration. But, all components of bands 1, 2 and 3 showed lower sperm migration and movement, compared to follicular fluid at the same additional level. 2. Among the components separated from follicular protein of 2~5mm follicles with reverse phase column ($\mu$RPC), components at retention time (RT) of 3.33, 7.00, 13.87, and 16.6A minutes stimulated sperm migration within a limited range. 3. All components separated from follicular protein of 10mm follicles with $\mu$RPC column didn't stimulate sperm migration and movement. 4. Among the components separated from follicular protein of 2~5m follicles with superose column, components at retention volume (RV) of 1.35 and 0.82 ml significantly stimulated sperm migration and movement. In conclusion, protein components stimulating sperm migration and movement were efficiently separated with superose column in Smart system. Especially, components of RV 1.35 and RV0.82 stimulated sperm swim-up separation.

  • PDF

British movement of 'Science and Citizenship' during the 1930-50s and L. Hogben's Science for the Citizen (1930-50년대 영국의 '과학식민의식' 운동과 L. Hogben의 Science for the Citizen)

  • Song, Jin-Woong
    • Journal of The Korean Association For Science Education
    • /
    • v.21 no.2
    • /
    • pp.385-399
    • /
    • 2001
  • In this study, the contexts and values of the movement called 'Science and Citizenship' during the 1930-50s are discussed in relation to the historical development of school science education in Britain and to the current STS movement in school science. A special attention is given to the activities and ideas of a then eminent biologist, Lancelot Hogben(1895-1975) who published a textbook-like science book, called "Science for the Citizen"(1938). From the beginning of the 20th century, there was a growing realization that British education system needed to be changed in order to provide school science teaching to a wider audience with more emphasis on the relevance, industrial and humanistic aspects of science. This was echoed by a lecture series called 'Science and Citizenship' which was reported in the School Science Review, then the only nationwide professional journal for science educators and by a group of professional scientists who had socialist ideas toward society. Hogben was one of the key member of the group and delivered the second lecture of 'Science and Citizenship', titled "Biological Instruction and education for Citizenship". Hogben's main idea, illustrated in this lecture as well as in "Science for the Citizen", was that science education should be a way of teaching citizen for promoting democratic society and to achieve that science need to be taught in more integrated, utilitarian and humanistic manners, for example by showing the usefulness, relevance, historical and democratic aspects of science. In addition, a summary of his own life and activities, the social background and socialist scientists of the time, and comparisons between 'Science and Citizenship' movement and the General Science movement in the UK as well as the progressive science education in the USA, and the STS education movement in 1980s are discussed.

  • PDF

Analysis of the Visual Attention to the 'Arrows' and the Affordance of Eye-movement of the 'Arrows' that Appear during the Course of Learning Science Textbooks of Pre-service Teachers: Focusing on the 'Weather and Our Life' Unit (예비교사의 과학교과서 학습 과정 중에 나타나는 '화살표'에 대한 시각적 주의 및 '화살표'의 시선 행동 유도성 분석: '날씨와 우리 생활' 단원을 중심으로)

  • Lim, Sung-man
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.13 no.3
    • /
    • pp.211-225
    • /
    • 2020
  • The purpose of this study was to investigate and analyze pre-service teachers' eye-movement in science textbooks in the learning process, whether they perceived "arrow" presented in textbooks, and changes in eye-movement by arrows. For the study, an eye-tracker, a eye-movement tracking device, was used, and 10 pre-service teachers attending a teacher training college were selected and conducted. The science textbook unit used in the research was the "Weather and Our Life" unit, one of the areas of earth science. As a result of the study, first, it was investigated that pre-service teachers devote more time to texts rather than illustrations in the learning process of science textbooks. Second, it was analyzed that pre-service teachers did not pay attention to the "arrow" presented in science textbooks. Third, it was confirmed that in order for "affordance of the eye-movement by arrow" to occur, sufficient concentration on "arrow" should be made. These findings suggest the importance of the learner's visual attention to learning elements in science textbooks such as "arrow". In addition, it suggests the importance of developing a textbook editing design that can induce visual attention to learning elements in textbooks through eye-movement research data for effective learning.