• Title/Summary/Keyword: motor development

Search Result 2,521, Processing Time 0.032 seconds

Study of Robust Position Recognition System of a Mobile Robot Using Multiple Cameras and Absolute Space Coordinates (다중 카메라와 절대 공간 좌표를 활용한 이동 로봇의 강인한 실내 위치 인식 시스템 연구)

  • Mo, Se Hyun;Jeon, Young Pil;Park, Jong Ho;Chong, Kil To
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.655-663
    • /
    • 2017
  • With the development of ICT technology, the indoor utilization of robots is increasing. Research on transportation, cleaning, guidance robots, etc., that can be used now or increase the scope of future use will be advanced. To facilitate the use of mobile robots in indoor spaces, the problem of self-location recognition is an important research area to be addressed. If an unexpected collision occurs during the motion of a mobile robot, the position of the mobile robot deviates from the initially planned navigation path. In this case, the mobile robot needs a robust controller that enables the mobile robot to accurately navigate toward the goal. This research tries to address the issues related to self-location of the mobile robot. A robust position recognition system was implemented; the system estimates the position of the mobile robot using a combination of encoder information of the mobile robot and the absolute space coordinate transformation information obtained from external video sources such as a large number of CCTVs installed in the room. Furthermore, vector field histogram method of the pass traveling algorithm of the mobile robot system was applied, and the results of the research were confirmed after conducting experiments.

A Study on Development of ECS for Severly Handicaped (중증 장애인을 위한 생활환경 제어장치개발에 관한 연구)

  • 임동철;이행세;홍석교;이일영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.427-434
    • /
    • 2003
  • In this paper, we present a speech-based Environmental Control System(ECS) and its application. In the concrete, an ECS using the speech recognition and an portable wheelchair lift control system with the speech synthesis are developed through the simulation and the embodiment. The developed system apply to quadriplegic man and we evaluate the result of physical effect and of mental effect. Speech recognition system is constructed by real time modules using HMM model. For the clinical application of the device, we investigate the result applied to 54-years old quadriplegic man during a week through the questionnaires of Beck Depression Inventory and of Activity Pattern Indicator. Also the motor drive control system of potable wheelchair lift is implemented and the mechanical durability is tested by structural analysis. Speech recognition rate results in over 95% through the experiment. The result of the questionnaires shows higher satisfaction and lower nursing loads. In addition, the depression tendency of the subject were decreased. The potable wheelchair lift shows good fatigue life-cycle as the material supporting the upper wheelchair and shows the centroid mobility of safety. In this paper we present an example of ECS which consists of real-time speech recognition system and potable wheelchair lift. Also the experiments shows needs of the ECS for korean environments. This study will be the base of a commercial use.

The Study on the Application of He-Ne Laser with Low Energy ILIB to the Superficial Venules (저용량(低容量) He-Ne 레이저침의 혈락적용(血絡適用) 연구(硏究))

  • Kim Sung-Chul;Cho Eun-Hee;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.20 no.3
    • /
    • pp.35-47
    • /
    • 2003
  • Objective : The purpose of this study was to investigate the significance of the Oriental medical treatment using He-Ne laser with low energy intravascular Laser Irradiation of Blood(ILIB) through the superficial venules. Methods : The investigation of details connected with the superficial venules in the literature is performed. The investigation of details connected with the pricking blood techniques through the superficial venules in the literature is performed. The classification of the pricking blood techniques through the superficial venules by the blood-letting puncture methods in the literature is performed. The arrangement of domestic clinical treatises on the effectiveness of medical treatment using He-Ne laser with low energy ILIB through the superficial venules is performed. The consideration on the methodology for the improvement of the clinical effectiveness of He-Ne laser with low energy ILIB through superficial venules is performed. Results and Conclusions : The superficial venules are small arteries, veins and capillaries in the superficial region of the human body. In the pricking blood techniques, there are the blood-letting puncture using the implement of acupuncture to the Jing points, Extra points and superficial blood vessels and the acupuncture using the Hirudo. The methods of the blood-letting puncture are classified into the venous blood-letting puncture, the pricking , the picking out white fiber-like substances from the subcutaneous tissue, the cluster needling, the scattered needling, the blood-letting puncture of the tready collateral branch of the large channel and the blood-letting puncture of skin. The He-Ne laser with low energy ILIB through the superficial venules belongs to the Oriental medical treatment as the method of the blood-letting puncture in the vein of cubital fossa. The He-Ne laser with low energy ILIB has an effect on hyperfibrinogenemia, hyperlipidemia, speech and motor dysfunction in the case of cerebral infarction, headache, dizziness, pain and numbness. It is considered that fundamental research on the biological change of the human body, the experimental animal and the unicellular animal, and research on the effectiveness and the safety, and the development of He-Ne laser with low energy ILIB of an effective wavelength range are necessary.

  • PDF

A comparative study of the acoustic characteristics of the vowel /a/ between children with spastic and dyskinetic cerebral palsy (경직형과 불수의운동형 뇌성마비아동의 /아/ 모음 음향학적 비교)

  • Jeong, Pil Yeon;Sim, Hyun Sub
    • Phonetics and Speech Sciences
    • /
    • v.12 no.1
    • /
    • pp.65-74
    • /
    • 2020
  • This study aims to compare the acoustic characteristics of vowel phonation in children with spastic and dyskinetic cerebral palsy (CP). Thirty-four children aged 4-12 years with CP participated in the study (spastic 26, dyskinetic 8). Voice samples for the acoustic analysis were extracted from a sustained vowel /a/. All acoustic measures were made using Praat. Group differences were compared by an independent t-test or Welch-Aspin test, if the equivalence assumption was not met. The results of this study are as follow. First, maximum phonation time(MPT) was significantly shorter for the dyskinetic CP than for the spastic CP. Second, shimmer percent was significantly increased in the dyskinetic CP than in the spastic CP. Lastly, there were no significant group differences in both the first formant and the second formant. These findings indicate that the dyskinetic CP has a poorer respiratory capacity and poorer laryngeal function than the spastic CP. On the other hand, both groups have a comparable ability to articulate the vowel /a/. The results of the present study help speech language pathologists identify the speech motor control ability of children with two types of CP (spastic and dyskinetic) and help to make an intervention plan associated with a specific type of CP.

DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC (MIRIS 우주관측카메라의 기계부 개발)

  • Moon, B.K.;Jeong, W.S.;Cha, S.M.;Ree, C.H.;Park, S.J.;Lee, D.H.;Yuk, I.S.;Park, Y.S.;Park, J.H.;Nam, U.W.;Matsumoto, Toshio;Yoshida, Seiji;Yang, S.C.;Lee, S.H.;Rhee, S.W.;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

Development of the Balance Chair for Improving Postural Control Ability & Pelvic Correction (골반교정 및 자세균형능력 증진을 위한 균형의자 개발)

  • Oh, Seung-Yong;Shin, Sun-Hye;Kang, Seung-Rok;Hong, Chul-Un;Kwon, Tae-Kyu
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.271-277
    • /
    • 2017
  • The purpose of this study was to develop a balance chair for improving pelvic correction and postural balance through postural balance training using tactile feedback by a vibration motor provided in real time according to the user's attitude. We built a body frame using mono cast(MC) Nylon, Touch thin film transistor(TFT) for user interface, a main control module using Arduino, a 9-axis acceleration sensor for user's posture determination, and a vibration module for tactile feedback. The prototype of the Balance Chair which surrounds the outside was made with cushion for sitting conformability. In order to verify the effectiveness of the postural balance training system using the built prototype, the muscle activity (% MVIC) of the left and right iliocostalis lumborum those are the main muscles of the spinal movement was measured with ten female subjects. And the balance ability before and after training was measured using Spine Balance 3D, a posture balance ability evaluation device. The muscular activities of the left and right iliocostalis lumborum showed the balance activation according to vibration feedback during exercise protocol and postural balance improved after balance exercise training using balance chair. This study could be apply to use the fundamental research for developing the various postural balance product.

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Development of Proportional Valve Actuator Controller for Industrial Site (산업용 밸브 액추에이터 비례제어 컨트롤러 개발)

  • Park, Han Young;Kim, Jin Young;Ahn, Sung Soo;Kang, Joonhee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.269-274
    • /
    • 2013
  • To proportionally control the electronic valve position of the actuator, we designed and fabricated PCU, CPT, and rotary absolute optical encoder for the detection of absolute angular position in the actuator. We also designed and constructed the test system by using DAQ hardware and Labview. We designed PCU to convert 1-5 V, 0-5 V, 0-10 V, 2-10 V voltage signals and 4-20 mA current signals to the voltage signals in the common 0.5-2.5 V range. We designed CPT to output 4-20 mA current signals corresponding to the valve positions based on the PWM signal input from the MCU. We also designed 20 bit optical encoder by using infrared LED and infrared transistor and made the serial communication with the main board possible. When we tested PCU and CPT with DAQ hardware and Labview software, they operated correctly with the small errors within ${\pm}0.003$ V and ${\pm}0.01$ mA, respectively, showing that our actuator has the excellent performance to employ as the industrial proportional-valve-actuator. The resolution of the encoder was $11.25^{\circ}$ and the maximum revolution to detect was 32,768.

Fungal Development, Respiration and Activity of Oxidative Enzymes in Rice Plants Inoculated with Pyricularia oryzae in Both Compatible and Incompatible Combinations (벼 도열병균에 감염된 친화 및 비친화 조합 벼에서의 균생장, 호흡 및 산화효소 활성)

  • Chung Bong-Koo;Chung Hoo-Sup
    • Korean journal of applied entomology
    • /
    • v.21 no.3 s.52
    • /
    • pp.113-122
    • /
    • 1982
  • Appressorial formation of Pyricularia oryzae on leaves showed no marked difference between highly resistant Tongil and susceptible Norm No. 6. Race N-2 of the blast fungus penetrated directly into motor cells of susceptible cultivar Norm No. 6, later extensively spreading hyphae were developed, while in the cultivar Tongil, after penetration, no further hyphal extension resulted. In discoloration of infected tissues, the highly resistant cultivar Tongil not only discolored rapidly, but also the percentage of discolored cells was higher than the susceptible cultivars, Jinheung and Norm No. 6. The respiratory rate, was generally higher in infected tissue than in healthy tissue. No significant difference in the respiration rate of resistant Suwon No. 180 was not found between the infected and healthy leaf tissue, whereas, in susceptible Jinheung, a marked increase in respiratory rate was caused by blast infection. The respiratory rate increased at the appearance of the first visible symptom in all cultivars resistant or susceptible. Higher peroxidase activity was found in infected tissues as compared with healthy tissue. Peroxidase activity increased in resistant and susceptible reactions. Particularly, in resistant reaction, the increase of the activity was more pronounced. In highly resistant reaction, there was no difference in peroxidase activity between healthy and infected tissues. Ascorbic acid oxidase, hydroquinone oxidase and catechol oxidase had the same trend as the peroxidase. In contrast, activity of catalase rather decreased in leaf tissues infected with compatible races of the fungus.

  • PDF

Development of Rotordynamics Program Based on the 2D Finite Element Method for Flywheel Energy Storage System (2차원 유한요소법을 적용한 플라이휠 에너지 저장 장치 동특성 해석 프로그램 개발)

  • Gu, Dong-Sik;Bae, Yong-Cae;Lee, Wook-Ryun;Kim, Jae-Gu;Kim, Hyo-Jung;Choi, Byeong-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1757-1763
    • /
    • 2010
  • Flywheel energy storage system (FESS) is defined as a high speed rotating flywheel system that can save surplus electric power. The FESS is proposed as an efficient energy storage system because it can accumulate a large amount of energy when it is operated at a high rotating speed and no mechanical problems are encountered. The FESS consists of a shaft, flywheel, motor/generator, bearings, and case. It is difficult to simulate rotor dynamics using common structure simulation programs because these programs are based on the 3D model and complex input rotating conditions. Therefore, in this paper, a program for the FESS based on the 2D FEM was developed. The 2D FEM can model easier than 3D, and it can present the multi-layer rotor with different material each other. Stiffness changing of the shaft caused by shrink fitting of the hub can be inputted to get clear solving results. The results obtained using the program were compared with those obtained using the common programs to determine any errors.