• Title/Summary/Keyword: motor block

Search Result 263, Processing Time 0.022 seconds

The Effect of Dual-task Training on a Serial Reaction Time Task for Motor Learning

  • Choi, Jin-Ho;Park, So Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.6
    • /
    • pp.405-408
    • /
    • 2012
  • Purpose: We examined the effect of dual-task and single-task training on serial reaction time (SRT) task performance to determine whether SRT is based more on motor or perception in a dual-task. Methods: Forty healthy adults were divided into two groups: the dual-task group (mean age, $21.8{\pm}1.6$ years) and the single-task group (mean age, $21.7{\pm}1.6$ years). SRT task was conducted total 480 trial. The four figures were presented randomly 16 times. A unit was set as 1 block that would repeat 10 times. Thus, there were a total of 160 trials for each of the three color conditions. The dual-task group performed an SRT task while detecting the color of a specific shape. The end of the task, subjects answered the specific shape number; the single-task group only performed the SRT task. The study consisted of three parts: pre-measurement, task performance, and post-measurement. Results: Differences of pre and post reaction time between two group was higher for the dual-task group as compared to the single task group and there was a significant interaction between time and group (p<0.05). Conclusion: Our results indicate that. short term period SRT is not quiet effective under dual-task conditions, individuals need additional cognitive processes to successfully navigate a task This suggests that dual-task training might not be appropriate for motor learning enhancement, at least when the training is over a short period.

A Study on the Design of Flat-Type IPMSM in Parallel Hybrid Traction Application (병렬형 하이브리드 구동용 매입형 영구자석동기전동기 설계에 대한 연구)

  • Kim Ki-Nam;Yang Hai-Won
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.718-724
    • /
    • 2004
  • This study investigates the design factors of Interior Permanent Magnet Synchronous Motor(IPMSM) which is applied to Hybrid electric vehicle as a driving power. Recently, there are many studies of IPMSM for application to Hybrid Electric Vehicle, because IPMSM has characteristics of high torque, high power density and high efficiency which come from reluctance torque due to difference of inductance as well as magnet torque. This study analyzes the inductance and design characteristics of IPMSM by using finite element method and focuses on design and analysis of IPMSM which can operates with high efficiency at low speed range. For this embodiment, magnet shape is changed from conventional block type to arc type without any change of outline dimension of motor and this change of magnet shape makes it possible to increase back EMF and sinusoidal waveform. Analysis results are verified by test of improved and embodied motor. As a test result , increased back EMF and sharply decrease of harmonics are secured and through this contribution of reduced fuel consumption of Hybrid electric vehicle is expected.

Relationships between upper extremity performance and unified Parkinson's disease rating scale-motor exam

  • Hwang, Wonjeong;Hwang, Sujin;Lee, Kyoungsuk;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.99-103
    • /
    • 2013
  • Objective: Clinical measures that quantify upper extremity function are needed for the accurate evaluation of patients and to plan an intervention strategy. The purpose of this study was to examine the relationship between the Unified Parkinson's Disease Rating Scale (UPDRS)-Motor Exam and upper extremity performance as a quantifying clinical tool of upper extremity function in persons with Parkinson's disease. Design: Cross-sectional study. Methods: Thirty-two idiopathic Parkinson's Disease persons participated in this study. To investigate the relationship between the UPDRS-motor exam, Box and Block test (BBT), and Action Research Arm Test (ARAT) by two physical therapists. The examination took up to 1 hour, and the participants were invited to rest between each clinical measure in order to minimize the effects of fatigue. Clinical measures were assessed while the subjects were in the "on" phase of their medication cycle, generally 1-3 hour after taking their anti-Parkinson's medications. Results: In more affected side, the UPDRS-motor exam was significantly negative correlated with the BBT (p<0.05) but it was not significantly correlated with the ARAT. In less affected side, only positively correlation was significantly shown between BBT and ARAT (p<0.05). On the other hand, between BBT and ARAT were not significantly correlated with the UPDRS-motor exam. Conclusions: The UPDRS-motor exam is effective tool which was significantly correlated with manual dexterity in more affected upper extremity. But The UPDRS-motor exam is not effective tool in less affected upper extremity.

A Strategy of a Gap Block Design in the CFRP Double Roller to Minimize Defects during the Product Conveyance (제품 이송 시 결함 최소화를 위한 CFRP 이중 롤러의 Gap block 설계 전략)

  • Seung-Ji Yang;Young-june Park;Sung-Eun Kim;Jun-Geol Ahn;Hyun-Ik Yang
    • Composites Research
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2024
  • Due to the structural characteristic of a double roller, the double roller can have various deformation behaviors depending on a gap block design, even if dimensions and loading conditions for the double roller are the same. Based on this feature, we propose a strategy for designing the gap block of the carbon-fiber reinforced plastic (CFRP) double roller to minimize defects (e.g., sagging and wrinkling), which can be raised during the product conveying process, with the pursue of the lightweight design. In the suggested strategy, analysis cases are first selected by considering main design parameters and engineering tolerances of the gap block, and then deformation behaviors of these selected cases are extracted using the finite element method (FEM). Here, to obtain the optimal gap block parameters that satisfy the purpose of this study, deformation deviations in the contact area are calculated and compared using the extracted deformation behaviors. Note that the contact area in this work is located between the product and the roller. As a result, through the design method of the gap block proposed in this work, it is possible to construct the CFRP double roller that can significantly decrease the defects without changing the overall sizes of the roller. A detailed method is suggested herein, and the results are evaluated in a numerical way.

Effect of Proprioceptive Neuromuscular Facilitation and Action Observation Training on Upper Extremity Motor Function in Stroke Patient: A Single-Subject Study (고유수용성신경근 촉진법 훈련과 동작관찰 훈련이 뇌졸중 환자의 상지 운동기능에 미치는 효과: 단일사례 연구)

  • Park, Hye-Ryoung;Lee, Moon-Kyu;Yun, Tae-Won
    • Physical Therapy Korea
    • /
    • v.22 no.1
    • /
    • pp.69-78
    • /
    • 2015
  • This study evaluated and compared the effectiveness on upper motor extremity function between proprioceptive neuromuscular facilitation which has been frequently used in clinical practice, and action observation training in terms of improving upper motor extremity function. A study with a single-subject design (A-B-C-A') was conducted with a patient who was diagnosed with left hemiplegia. A repeated-measure analysis was conducted to assess results of the Wolf Motor Function Test (WMFT), Box and Block Test (BBT), and grip and pinch strength test performed daily in the study for 4 weeks. The results of the analysis indicated that the WMFT score, BBT score, grip strength, and pinch strength were improved from 29.60 to 39 (24.10%), from 1.67 to 4.93 each (EA) (66.22%), from 2.06 to 2.66 libras (lbs) (22.61%), and from 1.57 to 1.93 lbs (18.94%), respectively, from the baseline period to treatment period B. The values were improved from 29.60 to 42.20 (29.86%), from 1.67 to 7 EA (76.21%), from 2.06 to 3.47 lbs (40.57%), and from 1.57 to 1.67 lbs (6.12%), respectively, from the baseline period to treatment period C. From treatment period B to treatment period C, the WMFT score, BBT score, and grip strength were improved from 39 to 42.20 (7.58%), from 4.93 to 7 EA (29.56%), and from 2.66 to 3.47 lbs (23.20%), respectively, but pinch strength was decreased from 1.93 to 1.67 lbs (15.83%). In conclusion, proprioceptive neuromuscular facilitation and action observation training both have positive effects on upper extremity motor function. However, we suggest that the posttreatment effect of action observation training was better than that of proprioceptive neuromuscular facilitation.

Experimental Study on Thermal Insulation and Cooling for Rotor/Bearing Area in 500W Class Micro Gas Turbine Generator (500W급 마이크로 가스터빈 발전기 회전체-베어링부의 단열 및 냉각 성능에 대한 실험적 연구)

  • Park, Cheol Hoon;Choi, Sang Kyu;Ham, Sang Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.3
    • /
    • pp.19-24
    • /
    • 2014
  • Development of long-term mobile energy sources for mobile robots or small-sized unmanned vehicles are actively increasing. The micro gas turbine generator (MTG) is a good candidate for this purpose because it has both of high energy density and high power density, and 500W class MTG is under development. The designed MTG can be divided into 2 main parts. One part consists of motor/ generator and compressor, and the other one consists of combustor, recuperator and turbine. 500W class MTG is designed to operate at ultra-high speed of 400,000 rpm in high turbine temperature over $700^{\circ}C$ to improve the efficiency. Because the magnetism of NdFeB permanent magnet for the motor/generator could be degraded if the temperature is over $150-200^{\circ}C$, MTG needs the thermal insulation to block the heat transfer from combustor/turbine side to motor/generator side. Moreover, the motor/generator is allocated to get the cooling effect from the rapid air flow by the compressor. This study presents the experimental results to verify whether the thermal insulator and air flow are effective enough to keep the motor/generator part in the low temperature less than $100^{\circ}C$. From the motoring test by using the high temperature test rig, it was confirmed that the motor/generator part could maintain the temperature less than $50^{\circ}C$ under the condition of 1.0 bar compressed air.

Development of an Image Tracking System Using an USB Camera on an Embedded System (USB Camera를 이용한 이미지 트래킹을 위한 Pan/Tilt 제어용 Embedded System 개발)

  • Kim, Hie-Sik;Nam, Chul;Ayurzana, Odgera;Ha, Kwan-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.182-184
    • /
    • 2005
  • An embedded system has been applied to many fields including households and industrial sites. The embedded system is implemented fur image tracking in security area. This system supports a fixed IP far the reliable server operation on TCP/IP networks. A real time video image on the is analyzed to detect a certain invader who jumped into the observed area. The digital camera is connected at the USB host port of the target board. The video images from the video camera is continuously analyzed and displayed at the Linux web-server. The moving vector of the invaders on the continuous image frames is calculated and then it sends the calculated pan/tilt movement. That used Block matching algorithm and edge detection algorithm for past speed. And the displacement vector is used at pan/tilt motor control through RS232 serial cable. The experiment result showed tracking performance by the moving part speed of 10 to 150 pixels/sec.

  • PDF

Literature Review of Neurogenic Bladder Care (신경인성 방광 간호에 관한 고찰)

  • Kim Won-Ock
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.225-236
    • /
    • 1998
  • The literature review about bladder management method given to maintain and improve health of neurogenic bladder patients was done. Because the study of neurogenic bladder patients in nursing field is not enough, I tried to find report the study tendency through literature review, 1. There are five types of neurogenic bladder such as uninhibited neurogenic bladder, reflex neurogenic bladder, autonomous neurogenic bladder, sensory paralytic neurogenic bladder, and motor paralytic neurogenic bladder. 2. The accurate assessment of neurogenic bladder is done mainly through urodynamics and especially cystometrogram and urethrogram are used. 3. As the study of therapeutic management, the effect of Desmopressin, bladder auto-augmentation, incision of external urethral sphincter muscle, subarachnoid block and pudendal never block using phenol was studied. 4. For the study of general management, the effect of bladder training progam, intermittent catheterization and infection control has been studied but there has not been any obvious study in nursing field. Reviewed the study condition, it is necessary to develope bladder training program in order to increase life quality of neurogenic bladder patients.

  • PDF

The Control of DC Servo Motor Applying High-speed Design System (고속 설계시스템을 응용한 DC 서보 모터의 제어)

  • 최환도;김재헌;김중완
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.675-678
    • /
    • 2002
  • A controller was designed generally using C or assembly languages on high-speed design controller. But, in this paper, DC servo controller is designed using the cord of the block-diagram of SIMTool. By the method, we can design, realized and analyzed a control system quickly in real-time. And we expect that the various plants of a robot vehicles are controled through the outside I/O board changing the structure of the block-diagram of SIMTool into AUTOTool. In addition, our developed system helps the most suitable automatic controller design and tester with hight-speed.

  • PDF

Paraplegia Caused by Vertebral Metastasis during Pain Control in Cervical Cancer Patient -A case report- (자궁경부암 환자의 통증치료중 척추전이에 의한 하반신 마비 -증례 보고-)

  • Kim, In-Jung;Chun, Bum-Soo;Kyeon, Il-Soo;Lee, Jung-Koo
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.304-307
    • /
    • 1997
  • Continuous epidural infusion, a combination of local anesthetic and opioid, have been widely administered for treatment of chronic cancer pain. A serious complications of epidural block is paraplegia which can also be caused by : direct spinal cord injury, epidural hematoma, epidural abscess, ischemic change, neurotoxicity, preexisting disease. Continuous epidural block for pain control of patient with cervical cancer was performed at $T_{12}/L_1$ interspace. A 4 cm catheter was inserted cephalad into the epidural space. After four months, back pain and motor weariless of lower extremities progressively developed. Spine CT showed bony destruction and soft mass-like lesion at $T_9$ & $T_{12}$ spine. We propose paraplegia was caused by spinal cord compression which resulted from vertebral metastasis of cervical cancer.

  • PDF