• 제목/요약/키워드: mortar-bar

검색결과 112건 처리시간 0.023초

전자기파를 이용한 모르타르 시편 내 철근탐사 (Probing of Steel Bar Inside Mortar Specimens Using Electromagnetic Wave Method)

  • 김우석;박경현;임홍철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.663-666
    • /
    • 1999
  • Ground Penetrating Radar (GPR) attached with 1 GHz center frequency antenna has been used to measure a dielectric constant of mortar, and to detect and locate a steel bar embedded inside laboratory size mortar specimens at various depth. Mortar specimens are made for the measurements with the dimensions of 100cm (width)$\times$100cm (length)$\times$14cm (depth). Each specimen has a 13mm diameter D13 steel bar at 2, 4, 6, 8, 10 and 12cm depth. In this paper, results of radar measurments are provided with a sample output, which successfully located the bar. It has been found that the reflected wave of the steel bar interacts with that of surface when the steel bar has the close distance to the surface.

  • PDF

Lateral confining action of mortar-filled sleeve reinforcement splice

  • Kim, Hyong-Kee;Lee, Sang-Ho
    • Structural Engineering and Mechanics
    • /
    • 제41권3호
    • /
    • pp.379-393
    • /
    • 2012
  • Of the various methods of splicing reinforcing bar in reinforced concrete structure, mortar-filled sleeve reinforcement splice offers diverse benefits, not only in terms of structural performance but also for the construction process. Consequently, after the mortar-filled sleeve splices have been developed in recent years, research and development on these splices has been actively carried out, in order to evaluate its macro structural performance, such as its strength and stiffness, with the aim of enabling this system to be applied to construction in the field as early as possible. However, to make a proper evaluation on the overall structural performance of the mortar-filled sleeve reinforcing bar splice, it is of critical importance to understand the lateral confining action of the sleeve, which is known to affect the bond strength between the embedded bar and mortar in the sleeve. Accordingly, in this study, an experiment of monotonic loading and cyclic loading was conducted with a full-sized mortar-filled sleeve splice attaching strain gauges on the sleeve surface with experimental variables such as development length of bar, etc. Based on the test results, the effect of the lateral confining action of the sleeve was analyzed and considered in terms of the bond strength between the bar and mortar in this splice.

Effect of Fineness Modulus of Reactive Aggregate on Alkali Silica Reaction

  • Jun, Ssang-Sun;Jin, Chi-Sub
    • International Journal of Concrete Structures and Materials
    • /
    • 제4권2호
    • /
    • pp.119-125
    • /
    • 2010
  • In this study, the effects of the fineness modulus of reactive aggregate on ASR expansion and ASR products have been investigated. The reactive aggregate used was metamorphic aggregate originated from Korea. ASR tests were conducted according to accelerated mortar bar test. The morphology and chemical composition of products formed in mortar bars, 5 years after the mortar bar test had been performed, were studied by scanning electron microscopy equipped with energy dispersive spectroscopy. Test results indicated that ASR expansion of mortar bars decrease in linear proportion to the fineness modulus of reactive aggregate. SEM images indicated that mortar bars showed reactive products formed in cement paste, within air voids and within cracks through particles except for the mortar bar with the fineness modulus of 3.25. The EDS analysis of the reactive products showed presence of silica, calcium and sodium, typical of ASR product composition.

Imaging of Steel Bars Embedded inside Mortar Specimens for Nondestructive Testing

  • Rhim, Hong-Chul;Park, Kyung-Hyun
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.139-144
    • /
    • 2000
  • Ground Penetrating Radar (GPR) with 1 GHz antenna has been used to locate a steel bar embedded inside laboratory-prepared mortar specimens. Four mortar specimens are made with the dimensions of 100 cm (length) x 100 cm (width) x 14 cm (depth). One specimen had no bars and the other three specimens had a Dl9 steel bar at 4, 6. and 8 cm depth. As a part of the experimental work, the dielectric constants of mortar specimens are measured during curing. As the curing time increased. the dielectric constant decreased with decreasing moisture content inside the specimen. The steel bar embedded inside mortar specimens has been successfully identified in all three cases. The results using signal processing scheme developed in this study significantly improved the output of a commercially available radar system.

  • PDF

고강도 모르타르를 충전한 기계적 슬리브 철근이음에 대한 단조가력 하에서의 강성 평가 (Evaluation on Stiffness of Mechanical Sleeve Bar Splice Filling High-strength Mortar Under Monotonic Loading)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권4호
    • /
    • pp.79-88
    • /
    • 2012
  • 본 연구에서는 고강도 모르타르 충전식 기계적 슬리브 철근이음에 대한 단조가력 하에서의 강성을 보다 적절하게 평가하기 위하여, 슬리브 철근이음의 주요한 구조요소가 미치는 단조가력 하에서의 철근이음 강성에 대한 영향을 검토하였고 AIJ 규준에서 설정한 단조가력 하에서의 슬리브 철근이음에 대한 강성 기준과 비교평가하였다. 이것을 위하여 단조가력을 실시한 국내외 189여개 고강도 모르타르 충전식 기계적 슬리브 철근이음의 실험데이터를 조사하고 그 실험결과를 분석하였다. 그 결과, AIJ 규준에서 규정하는 목표 강성을 확보하는데 필요한 $f_g$(L/d)의 한계값을 철근의 종류와 슬리브의 종류에 따라서 각각 제시하였다.

국내 쇄석골재를 사용한 모르타르 봉 및 콘크리트 각주 시험편의 알칼리-실리카 반응성 비교 (Comparison of Alkali-Silica Reactivity for Mortar Bar and Concrete Prism Specimens Using Crushed Aggregates in Korea)

  • 김성권;윤경구;허인
    • 한국도로학회논문집
    • /
    • 제14권5호
    • /
    • pp.93-99
    • /
    • 2012
  • PURPOSES: The purpose of this study is to compare the alkali-silica reactivity for mortar bar and concrete prism specimens using crushed aggregates of 5 types in Korea. And the alkali-silica reactivity for those aggregates are measured by chemical test method. METHODS: The alkali-silica reactivity for those aggregates was measured by chemical test method of KS F 2545, mortar-bar test of KS F 2546, accelerated mortar-bar test method of ASTM C 1260 and concrete prism test method of ASTM C 1293, relatively. RESULTS: The alkali-silica reactivity for those aggregates was verified by chemical test of KS F 2546 and accelerated mortar-bar test of ASTM C 1260. However, it was not by mortar-bar test of KS F 2546 and concrete prism test of ASTM C 1293. CONCLUSIONS: The above results showed that relationship among the four test methods were very low. The results from 3 types of test methods using cement-aggregate combinations appeared to be different. Because the environmental conditions of test methods for measuring the alkali-silica reactivity such as equivalent alkali content(external source), humidity, temperature, and times were different though the aggregates were same. Moreover, alkali-silica reactivity showed the biggest impact when alkalis were supplied form outside and exposed to environmental conditions. The accelerated mortar-bar test method seems to be most appropriate test method for concrete structures exposed to alkali environment.

폴리머 시멘트 몰탈의 철근 부착특성 평가 (Bond Properties of Polymer Cement Mortar to Reinforced Steel Bar)

  • 박동천;조규환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.106-107
    • /
    • 2013
  • The purpose of this study is to characterize the bonding properties between reinforced bar and re-emulsion polymer cement mortar through the pull off test. The properties of polymer cement mortar before and after hardening were measured. Spiral reinforced steel bar was used to control the brittleness fracture of test specimens. In addition polymer content as experimental factors, the types of reinforced bar and corrosion were considered as well. Non linear FEM analysis was carried out to expect the behavior of bonding interface under the certain load.

  • PDF

반복하중을 받는 SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음의 구조성능 (Structural Performance of Mortar-filled Sleeve Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.180-192
    • /
    • 2008
  • 본 연구에서는 보다 자유로운 형상의 슬리브를 만들 수 있는 구상흑연 주철을 이용하여 보다 효과적으로 구조성능을 발휘하면서 SD500 고강도 철근에 적합하게 개발된 모르타르 충전식 슬리브 철근이음을 대상으로 실물크기의 19개 실험체를 제작하여 반복가력실험을 실시하였다. 그리고 강도, 강성, 슬립을 중심으로 한 구조성능에 대하여 본 실험의 주요한 변수에 따르는 영향을 분석하고, 국내기준을 비롯한 주요기준의 요구 성능과 비교하였다. 본 연구결과에서는 SD500 고강도 철근용으로 개발한 모르타르 충전식 슬리브 철근이음은 반복하중이 작용하는 경우에 대하여 국내기준을 비롯한 주요기준에서 요구하는 구조성능을 보유하고 있는 것이 확인되었고, SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음에 대한 구조설계 기준 정립에 필요한 정량적인 기술 데이터를 제시하였다.

간이 내화시험에 의한 석고계 모르타르의 내화성능 (Fireproof Performance of Mortar using Gypsum in Simplified Heating Test)

  • 강석표
    • 한국건축시공학회지
    • /
    • 제11권2호
    • /
    • pp.181-188
    • /
    • 2011
  • 고강도콘크리트 부재 표면에 내화모르타르를 피복하여 화재시 콘크리트 표층부의 온도상승을 저감시킴으로서 내부 철근온도 상승을 억제한다. 본 논문은 간이내화시험을 통하여 시멘트 및 석고계 내화모르타르 피복 고강도콘크리트의 내부철근 온도상승을 검토하기 위한 것이다. 그 결과 석고계 내화모르타르가 시멘트계 내화모르타르보다 고강도콘크리트의 내부철근 온도상승을 저감시키는데 효과적인 것으로 나타났으며 내화모르타르 피복두께가 작을수록 시멘트계 내화모르타르와의 내부 철근 온도차이가 증가하였다. 또한 ${\alpha}$형 반수석고와 ${\beta}$형 반수석고 종류에 따른 내화모르타르의 온도상승 저감효과의 차이는 없는 것으로 나타났지만, ${\alpha}$형 반수석고 내화모르타르의 압축강도가 ${\beta}$형 반수석고 내화모르타르보다 높게 나타났다.

알칼리-실리카 반응에 의한 모르타르 봉의 SEM과 EPMA 분석을 통한 미세구조 연구 (Microstructural Study of Mortar Bar on Akali-Silica Reaction by Means of SEM and EPMA Analysis)

  • 전쌍순;이효민;진치섭
    • 콘크리트학회논문집
    • /
    • 제21권4호
    • /
    • pp.531-537
    • /
    • 2009
  • 이 연구에서는 알칼리-실리카 반응성을 평가하는데 적용되는 ASTM C 227과 ASTM C 1260 모르타르 봉 시험법으로 쇄석골재의 반응성을 평가하고, 제작된 모르타르를 3년간 일반 환경에 노출시킨 뒤, 알칼리-실리카 반응으 로 인해 생성될 수 있는 반응생성물 확인과 화학분석을 위해 SEM과 EPMA 분석을 실시하였다. 이 연구에서는 SEM의 secondary electron image(SEI)와 EPMA의 backscattered electron image(BSEI)를 이용하였다. 이 연구에 사용된 쇄석골재 는 ASTM C 227에 의해서는 2년간 뚜렷한 팽창을 나타내지 않았지만, KOH 용액을 이용한 반응촉진법에 의해서는 유 해 가능성이 있는 것으로 나타났다. 모르타르 봉 시험 시행 후, SEM SEI 분석 결과, ASTM C 227에 의해 제작된 모 르타르 봉에서는 골재 입자와 시멘트페이스트 사이에 알칼리-실리카 반응에 의한 흔적이나 pore 내에서 반응생성물이 확인되지 않았다. 하지만 ASTM C 1260에 의한 모르타르 봉에서는 알칼리-실리카 반응의 전형적인 반응생성물로 알려 진 꽃잎형(rosette morphology)의 알칼리-실리카 겔(gel)이 확인되었다. EPMA 분석 결과, ASTM C 227에 의한 모르타르 봉에서도 골재 입자 표면에 부분적으로 미세하게 Al-ASR gel이 확인됨에 따라 ASTM C 227에 의해 2년간 무해한 팽 창을 나타내었던 모르타르 봉에서도 알칼리-실리카 반응이 발생하고 있음을 알 수 있었다. 반응성 촉진 시험 후의 모르 타르의 EPMA 분석 결과에서는 골재 입자에 발생된 균열 내부뿐만 아니라 pore 내부에 알칼리-실리카 겔이 축적되어 있는 것으로 나타났으며, 또한 pore 내에서 확인된 겔이 골재 입자 내부에 생성된 겔에 비해 Ca 함량이 더 풍부한 것 으로 나타났다. 국내에서 생산되는 쇄석골재 사용으로 인하여 구조물 내부에 발생한 변화를 미세구조를 통해 확인한 결 과, 알칼리-실리카 반응에 의한 구조물 열화를 알 수 있었다. 따라서, 국내 쇄석골재 사용량 증가에 따라 새로운 건설에 있어서 알칼리-실리카 반응 방지를 위한 고려가 있어야 할 것으로 판단된다.