• Title/Summary/Keyword: monitoring measurement

Search Result 2,742, Processing Time 0.039 seconds

Analysis of Unrest Signs of Activity at the Baegdusan Volcano (백두산 화산의 전조활동 분석 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • The Baegdusan volcano is one of the most active volcanoes in northeastern Asia, and the 10th century eruption was the most voluminous eruption in the world in recent 2,000 years. During the period from 2002 to 2005, volcanic earthquakes and abnormal surface distortions by suspected subsurface magma intrusion beneath the volcano were observed in the Baegdusan area. Seismic activity has gradually increased with earthquake swarms during 2002-2003 and hundreds of seismic event in a day, especially annual peak of 2,100 in 2003. Then the number of seismic activity has declined since 2006 to the background level in 1999-2001. According to the typical frequency of volcanic earthquakes in the Baegdusan volcano, the frequency distribution of typical volcanic earthquakes between 2002 and 2005 indicates that all the main frequency of the earthquakes basically falls down less than 5 Hz and 5-10 Hz. These events are all the VT-B and LP events caused by the shallow localized fracture and intrusion of magma. The horizontal displacement measurement by GPS during the period from 2000 to 2007 of the Baegdusan stratovolcano area indicates that an inflated process has been centered at the summit caldera since 2002. The displacement between 2002 and 2003 reached at a maximum value of 4 cm. After 2003, the deformation rate of the volcano continued to decrease with unusual variation during the period from 2006 to 2007. After 2003 the vertical displacement uplift rate falls down gradually but still keeps in an uplift trend in northern slope. It is generally believed that when $^3He/^4He(R)$ in a gas sample from a hot spring exceeds $^3He/^4He(R)$ in the atmosphere, it can be concluded that mantle-source. And temperatures of hot springs are rising steadily to $83^{\circ}C$. It is unrest signals at the Baegdusan, which is potentially active. The Baegdusan volcano is now in unrest status, there is eruption threat in the near future. Intensified monitoring and emergency response plan for volcanic risk mitigation are urgent for the volcano.

Validation of the Korean Version of the St. George's Respiratory Questionnaire for Patients with Chronic Respiratory Disease (한국어판 세인트조지 호흡기설문의 타당도와 신뢰도 검정)

  • Kim, Young Sam;Byun, Min Kwang;Jung, Wou Young;Jeong, Jae Hee;Choi, Sang Bong;Kang, Shin Myung;Moon, Ji Ae;Han, Jung Suk;Nam, Chung-Mo;Park, Moo Suk;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • Background: The "health-related quality of life" (HRQL) for patients with chronic respiratory disease has been emphasized, because chronic respiratory disease (CRD) is chronic and progressive, and it finally causes disability. HRQL instruments may be useful for monitoring patients' progress or for determining the most appropriate choice of treatment. We describe the adapting St George's Respiratory Questionnaire (SGRQ), which is a self-administered questionnaire developed by Jones et al. (1991), into the Korean version for covering three domains of health for the patients suffering with airways disease. Method: We obtained the original SGRQ from the author after gaining permission. For adaptation, we created an expert panel and translated the original questionnaire into Korean language. The translated questionnaire was then back-translated by bilingual experts and we compared it with the original questionnaire. After correction and feasibility testing, 74 patients with chronic respiratory disease (COPD, asthma, destroyed lung) completed the Korean version of the SGRQ. The clinical status of each patients was evaluated concurrently with measurement of their health status. Result: The Korean version of the SGRQ was acceptable and easy to understand. Cronbach's alpha reliability coefficient was 0.92 for the overall scale and 0.63 for the "Symptoms", subscale, 0.87 for the "Activity", subscale, and 0.89 for the "Impacts" subscales. The correlation coefficients between the overall score and the Borg scale score, oxygen saturation, and forced expiratory volume in one second ($FEV_1$) were 0.52, -0.32 and -0.26, respectively. These results support that the Korean SGRQ was correlated with other measurements. Conclusion: The Korean SGRQ was reliable and valid for patients with chronic respiratory disease, such as COPD, asthma, and destroyed lung. The SGRQ score was well correlated with other respiratory measurements as well. Although further studies should complete the adaptation work, our results suggest that the SGRQ may be used in Korea and also for international studies involving Korean CRD patients.

Reproducibility of Gated Myocardial Perfusion SPECT for the Assessment of Myocardial Function: Comparison with Thallium-201 and Technetium-99m-MIBI (심근 기능 측정에 사용된 게이트 심근 관류 SPECT 방법의 재현성 평가: $^{201}Tl$$^{99m}Tc$-MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Hong, Eui-Soo;Kim, Dae-Hyuk;Kim, Sung-Eun;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2000
  • Purpose: We compared the reproducibility of $^{201}Tl\;and\;^{99m}Tc$-sestamibi (MIBI) gated SPECT measurement of myocardial function using the Germano algorithm Materials and Methods: Gated SPECT acquisition was repeated in the same position in 30 patients who received $^{201}Tl$ and in 26 who received $^{99m}Tc$-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on $^{201}Tl\;and\;^{99m}Tc$-MIBI gated SPECT was processed independently using Cedars quantitative gated SPECT software. The reproducibility of the assessment of myocardial function on $^{201}Tl$ gated SPECT was compared with that of $^{99m}Tc$-MIBI gated SPECT Results: Correlation between the two measurements for volumes and EF was excellent by the repeated gated SPECT studies of $^{201}Tl$ (r=0.928 to 0.986; p<0.05) and $^{99m}Tc$-MIBI (r=0.979 to 0.997; p<0.05). However, Bland Altman analysis revealed the 95% limits of agreement (2 SD) for volumes and EF were tighter by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 14.1 ml, ESV: 9.4 ml and EF: 5.5%) than by repeated $^{201}Tl$ gated SPECT (EDV: 24.1 ml, ESV: 18.6 ml and EF: 10.3%). The root mean square (RMS) values of the coefficient of variation (CV) for volumes und EFs were smaller by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 2.1 ml, ESV 2.7 ml and EF: 2.3%) than by repeated $^{201}Tl$ gated SPECT (EDV: 3.2 ml, ESV: 3.5 ml and EF: 5.2%). Conclusion: $^{99m}Tc$-MIBI provides more reproducible volumes and EF than $^{201}Tl$ on repeated acquisition gated SPECT. $^{99m}Tc$-MIBI gated SPECT is the preferable method for the clinical monitoring of myocardial function.

  • PDF

A cluster analysis of the audit result on quality management system in architectural design and engineering firms (설계 및 엔지니어링분야의 품질경영시스템 심사결과에 대한 유형분석)

  • Bae Dae-kwon;Kim Soo-Yoo;Kim Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.2 s.24
    • /
    • pp.120-128
    • /
    • 2005
  • ISO 9001, the quality management system issued by the International Organization for Standardization, is being used by architectural design and engineering firms in order to strengthen the capability of business activities through the implementation of the international and advanced quality management systems. However, there have been significant problems in stable implementation and settlement of ISO 9001 in construction industry, which seem to be caused by key employees' lack of proper recognition and comprehension. The purpose of this research, accordingly, is to find and analyze nonconformity results which were found when the third party registrars audited the conformity of companies' quality management systems for ISO 9001 certification especially in architectural design and engineering firms. For this purpose this research was conducted by a cluster analysis of 647 audit reports out of representative 15 architectural design and engineering firms that have been audited periodically from 1997 to 2003 by the third party registrars. The analysis showed that the most frequent problems were generated in the areas of $\ulcorner$Design and Development$\lrcorner$ , $\ulcorner$production and Service Provision$\lrcorner$ , and $\ulcorner$General requirements$\lrcorner$ of the quality management system. The following, the areas of $\ulcorner$Monitoring and Measurement$\lrcorner$ and $\ulcorner$purchasing$\lrcorner$ were also analyzed as main factors which caused frequent nonconformity results. This research also shows that the corrective actions for nonconformity results are closely connected with the whole management activities in architectural design and engineering firms. Consequently, corrective actions for disposition of nonconformities should be implemented more specifically in order to settle and activate the quality management systems in architectural design and engineering firms.

Analysis of the growth environment and fruiting body quality of Pleurotus eryngii cultivated by Smart Farming (큰느타리(새송이)버섯 스마트팜 재배를 통한 생육환경 분석 및 자실체 품질 특성)

  • Kim, Kil-Ja;Kim, Da-Mi;An, Ho-Sub;Choi, Jin-Kyung;Kim, Seon-Gon
    • Journal of Mushroom
    • /
    • v.17 no.4
    • /
    • pp.211-217
    • /
    • 2019
  • Currently, cultivation of mushrooms using the Information and Communication Technology (ICT)-based smart farming technique is increasing rapidly. The main environmental factors for growth of mushrooms are temperature, humidity, carbon dioxide (CO2), and light. Among all the mentioned factors, currently, only temperature has been maintained under automatic control. However, humidity and ventilation are controlled using a timer, based on technical experience.Therefore, in this study, a Pleurotus eryngii first-generation smart farm model was set up that can automatically control temperature, humidity, and ventilation. After installing the environmental control system and the monitoring device, the environmental condition of the mushroom cultivation room and the growth of the fruiting bodies were studied. The data thus obtained was compared to that obtained using the conventional cultivation method.In farm A, the temperature during the primordia formation stage was about 17℃, and was maintained at approximately 16℃ during the fruiting stage. The humidity was initially maintained at 95%, and the farm was not humidified after the primordia formation stage. There was no sensor for CO2 management, and the system was ventilated as required by observing the shape of the pileus and the stipe. It was observed that, the concentration of CO2 was between 700 and 2,500 ppm during the growth period. The average weight of the mushrooms produced in farm A was 125 g, and the quality was between that of the premium and the first grade.In farm B. The CO2 sensor was in use for measurement purposes only; the system was ventilated as required by observing the shape of the pileus and the stipe. During the growth period, the CO2 concentration was observed to be between 640 and 4,500 ppm. The average weight of the mushrooms produced in farm B was 102 g.These results indicate that the quality of the king oyster mushroom is determined by the environmental conditions, especially by the concentration of CO2. Thus, the data obtained in this study can be used as an optimal smart farm model, where, by improving the environmental control method of farm A, better quality mushrooms were obtained.

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.

A Measures to Implements the Conservation and Management of Traditional Landscape Architecture using Aerial Photogrammetry and 3D Scanning (전통조경 보존·관리를 위한 3차원 공간정보 적용방안)

  • Kim, Jae-Ung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.38 no.1
    • /
    • pp.77-84
    • /
    • 2020
  • This study is apply 3D spatial information per traditional landscape space by comparing spatial information data created using a small drone and 3D scanner used for 3D spatial information construction for efficient preservation and management of traditional landscaping space composed of areas such as scenic sites and traditional landscape architectures. The analysis results are as follows. First, aerial photogrammetry data is less accurate than 3D scanners, but it was confirmed to be more suitable for monitoring landscape changes by reading RGB images than 3D scanners by texture mapping using digital data in constructing orthographic image data. Second, the orthographic image data constructed by aerial photogrammetry in a traditional landscaping space consisting of a fixed area, such as Gwanghalluwon Garden, produced visually accurate and precise results. However, as a result of the data extraction, data for trees, which is one of the elements that make up the traditional landscaping, was not extracted, so it was determined that 3D scanning and aerial surveying had to be performed in parallel, especially in areas where trees were densely populated. Third, The surrounding trees in Soswaewon Garden caused many errors in 3D spatial information data including topographic data. It was analyzed that it is preferable to use 3D scanning technology for precise measurement rather than aerial photogrammetry because buildings, landscaping facilities and trees are dense in a relatively small space. When 3D spatial information construction data for a traditional landscaping space composed of area using a small drone and a 3D scanner free from temporal and spatial constraints and compared the data was compared, the aerial photogrammetry is effective for large site such as Hahoe Village, Gyeongju and construction of a 3D space using a 3D scanner is effective for traditional garden such as Soswaewon Garden.

A Comparative Study on Knowledge of Hypertension and Blood Parameters Between a Well-Controlled Hypertension Group and an Uncontrolled Hypertension Group Commuting to a Public Health Center (보건소의 혈압이 조절되는 고혈압 환자와 조절되지 않는 고혈압 환자의 고혈압관련 지식 및 혈액성상)

  • Cho, Kyung-Ok
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.10
    • /
    • pp.1287-1292
    • /
    • 2007
  • The purpose of this study was to compare knowledge on hypertension and blood parameters through blood pressure control of hypertensive patients commuting to a public health center. Hypertensive subjects were classified according to their blood pressures into a well-controlled group (SBP<140 mmHg and DBP<90 mmHg, n=44) and an uncontrolled group ($SBP\geq140mmHg\;or\;DBP\geq90mmHg$, n=41). All subjects were interviewed for clinical characteristics, effort for health maintenance and knowledge on hypertension and nutrition. Biochemical measurement of blood urea nitrogen, creatinine, triglyceride, total cholesterol, HDL-cholesterol and fasting blood glucose (FBG) were obtained from subjects. The knowledge about hypertension and effort for health maintenance were not significantly different between the groups. However, the nutrition knowledge score of the well-controlled group was significantly higher (p<0.05) than that of the uncontrolled group. On the test of nutrition knowledge, 97.7% of the well-controlled group answered correctly to the item, 'Medication is an easy way to control blood pressure'. This result was significantly higher (p<0.05) than that of the uncontrolled group of whom 82.9% answered correctly. Participants in both groups had only a little understanding about the importance of a balanced diet. Blood parameters were in the normal range and there was not a significant difference between the groups. However total cholesterol, triglyceride and fasting blood glucose levels of the uncontrolled group were higher than those of the well-controlled group. Therefore, education programs about the continuous control of hypertension through careful monitoring, medication, and exercise are required. The uncontrolled group was especially in need of strengthening education. Also more effective nutrition education programs about low salt, high fiber, low cholesterol, and balanced diets are required for hypertensive patients commuting to public health center.

An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter (mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도)

  • Koh, Young-Il;Choi, In-Seon;Na, Hyun-Ju;Park, Seok-Chae;Jang, An-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.298-308
    • /
    • 1997
  • Background : Portable devices for measuring peak expiratory flow(PEF) are now of proved value in the diagnosis and management of asthma and many lightweight PEF meters have become available. However, it is necessary to determine whether peak expiratory flow rate(PEFR) measurements measured with peak flowmeters is accurate and reproducible for clinical application. The aim of the present study is to define accuracy, agreement, and precision of mini-Wright peak flow meter(MPFM) against standard pneumotachygraph. Methods : The lung function tests by standard pneumotachygraph and PEFR measurement by MPFM were performed in a random order for 2 hours in 22 normal and 17 asthmatic subjects and also were performed for 3 successive days in 22 normals. Results : The PEFR measured with MPFM was significantly related to the PEFR and $FEV_1$ measured with standard pneumotachygraph in normal and asthmatics(for PEFR, r = 0.92 ; p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). The accuracy of MPFM was within 100(limits of accuracy recommeded by NAEP) in all the subjects or 22 normal, mean difference from standard pneumotachygraph being 16.5L/min(percentage of difference being 2.90%) or 10.6L/min(percentage of difference being 1.75%), respectively. According to the method proposed by Bland and Altman, the 95% limits of the distribution of differences between MPFM and standard pneumotachygraph after correction of PEFR using our regression equation were +38.2 and -71.5L/min in all the subjects or 20.49~+9.49L/min in 22 normal and was similar to the intraindividual agreements for 3 successive days in normal. There was no statistically significant difference of PEFR measured with MPFM and standard pneumotachygraph among three days(p > 0.05) and the coefficient of variation($2.4{\pm}1.2%$) of PEFR measured with MPFM was significantly lower than that($5.2{\pm}3.5%$) with standard pneumotachygraph in normal (p < 0.05). Conclusion : This results suggest that the MPFM was as accurate and reproducible as standard pneumotachygraph for monitoring of PEFR in the asthmatic subjects.

  • PDF

A Study on Establishment of the Optimum Mountain Meteorological Observation Network System for Forest Fire Prevention (산불 방지를 위한 산악기상관측시스템 구축방안)

  • Lee, Si-Young;Chung, Il-Ung;Kim, Sang-Kook
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.1
    • /
    • pp.36-44
    • /
    • 2006
  • In this study, we constructed a forest fire danger map in the Yeongdong area of Gangwon-do and Northeastern area of Gyeongsangbuk-do using a forest fire rating model and geographical information system (GIS). We investigated the appropriate positions of the automatic weather station (AWS) and a comprehensive network solution (a system including measurement, communication and data processing) for the establishment of an optimum mountain meteorological observation network system (MMONS). Also, we suggested a possible plan for combining the MMONS with unmanned monitoring camera systems and wireless relay towers operated by local governments and the Korea Forest Service for prevention of forest fire.