• Title/Summary/Keyword: monitoring interval

Search Result 365, Processing Time 0.029 seconds

Real-time monitoring sensor displacement for illicit discharge of wastewater: identification of hotspot using the self-organizing maps (SOMs) (폐수의 무단 방류 모니터링을 위한 센서배치 우선지역 결정: 자기조직화지도 인공신경망의 적용)

  • Nam, Seong-Nam;Lee, Sunghoon;Kim, Jungryul;Lee, Jaehyun;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.151-158
    • /
    • 2019
  • Objectives of this study were to identify the hotspot for displacement of the on-line water quality sensors, in order to detect illicit discharge of untreated wastewater. A total of twenty-six water quality parameters were measured in sewer networks of the industrial complex located in Daejeon city as a test-bed site of this study. For the water qualities measured on a daily basis by 2-hour interval, the self-organizing maps(SOMs), one of the artificial neural networks(ANNs), were applied to classify the catchments to the clusters in accordance with patterns of water qualities discharged, and to determine the hotspot for priority sensor allocation in the study. The results revealed that the catchments were classified into four clusters in terms of extent of water qualities, in which the grouping were validated by the Euclidean distance and Davies-Bouldin index. Of the on-line sensors, total organic carbon(TOC) sensor, selected to be suitable for organic pollutants monitoring, would be effective to be allocated in D and a part of E catchments. Pb sensor, of heavy metals, would be suitable to be displaced in A and a part of B catchments.

Residue Monitoring and Dietary Risk Evaluation of Fungicide Propiconazole in Leafy Vegetables under Greenhouse Conditions

  • Lawal Abdulkareem;Ji-Eun Oh;Se-Yeon Kwak;Sang-Hyeob Lee;Jae-Won Choi;Aniruddha Sarker;Kee Sung Kyung;Tae Hwa Kim;Jang-Eok Kim
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.3
    • /
    • pp.193-202
    • /
    • 2023
  • Residue monitoring of propiconazole (PCZ) in cabbage, shallot, and spinach was conducted under multi-trial greenhouse conditions. This study aimed to understand the fate of the applied fungicide in these vegetables. Furthermore, the associated health risk of PCZ in leafy vegetables was assessed through dietary risk assessment. Commercially available PCZ (22% suspension concentrate) was administered thrice according to the OECD fungicide application interval guideline. The plant samples were extracted using a slightly modified QuEChERS technique and analyzed using gas chromatography-tandem mass spectrometry. The average PCZ recovery was between 84.5% and 117.6%, with a <5% coefficient of variance. The dissipation of PCZ residue in cabbage, shallot, and spinach after 14 days was 96%, 90%, and 99%, respectively, with half-lives of <5 days. Meanwhile, dietary risk assessments of PCZ residues in the studied vegetables using the risk quotient (RQ) were significant < 100 (RQ < 100). Thus, the population groups considered in this study were not at substantial risk from consuming leafy vegetables sprayed with PCZ following critical, good agricultural practices.

Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature (지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성)

  • Jonghoon Park;Dongyeop Lee;Nam C. Woo
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.563-570
    • /
    • 2022
  • This study was objected to show the complexity of groundwater flow system in a site-scale area as a design parameter of the groundwater monitoring network for early detection of pollutant leakage from a potential source of groundwater contamination (e.g., storage tank). Around the tanks, three monitoring wells were installed at about 22~25 m deep and groundwater level and temperature had been monitored for 22 months by 2-minute interval, and then compared with precipitation and temperature data from nearby weather station. Annual variation of groundwater level and its response to precipitation event, variation of groundwater temperature and delayed response to that of atmospheric temperature indicate the complexity of groundwater flow and flow paths even in the relatively small area. Thus, groundwater monitoring network for early detection of contaminant leakage should be designed with full consideration of the complexity of groundwater flow system, identified from the detailed hydrogeological investigation of the site.

Real-time Remote Monitoring System of Chemical Accident Response based on Multi-hop Communication (멀티 홉 통신을 기반한 화학 사고 대응 실시간 원격 모니터링 시스템)

  • Lee, Seung-Chul;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1706-1712
    • /
    • 2022
  • Recently, the safety of chemical substances has gained attention due to incidents occurring in petrochemical industrial complexes, such as gas leaks and fires. In particular, industrial complexes in Ulsan and Yeosu (South Korea) are valuable as they significantly contribute to the petrochemical industry, but accidents may occur due to chemical leakage. Therefore, in this study, sensor nodes are configured at an interval of 20 [m] based on outdoor facilities standards to respond to chemical accidents, and exposure consideration of 8 h (TWA) and 15 min (STEL) are proposed in TLVs. The proposed system pre-processes data collected in multi-hop communication at a cycle of 0.6-0.75 [s] using Python and stores it in the MySQL database through SQL and a real-time remote monitoring system that updates the stored data once every 5 s is implemented by linking MySQL and Grafana.

Mode Sensing of a Composite Beam Using Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 구조물의 모드 형상 측정)

  • 구본용;류치영;홍창선
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.163-166
    • /
    • 2000
  • Fiber Bra99 grating (FBG) sensor, one of the fiber optic sensor (FOS) offers lots of advantages for structural health monitoring due to its multiplexing capability. Also, it is proper to measure the structural vibration with no mass concentration effect. In this paper, we constructed two sensor arrays composed of 9 FBG sensors for the vibration and mode sensing of a composites beam. For an accurate measurement of wavelength shift, a signal processing board with an electric circuit based on time-interval counting was developed. This sensor system showed a good resolution of dynamic strain (<10${\mu}{\varepsilon}$). Using this sensor system, dynamic strains at 9 points of composite beam was measured and strain measured mode shape of the beam was calculated from the acquired strains and compared with numerical results by ABAQUS.

  • PDF

Improving the Performance of Market Surveillance (증권시장에서의 효과적인 주가감시모형)

  • 안철환
    • Journal of Korean Society for Quality Management
    • /
    • v.28 no.1
    • /
    • pp.1-12
    • /
    • 2000
  • Since Black Monday there has been a rash of systems developments which aimed at automating and upgrading the surveillance mechanism of monitoring the many facets of security trading. A more sophisticated mathematical model for detecting abnormal trading activities was created by Davis and Ord of Penn State along with Nobel prize laureates Solow and Modigliani of MIT. They used CAPM(Capital Asset Pricing Model) to explain the movements of stock price and applied an idea of residuals to detect unusual movements. In this paper, their idea is discussed and a new method is proposed, which involves a confidence interval of future observation in linear regression. One of the examples of the stock watch system adopting this statistical method is also presented.

  • PDF

Determinating Sensor Location for Guided-Wave-Based Long Range Pipeline Inspection (유도파 기반 장거리 파이프라인 검사를 위한 모니터링 센서의 위치결정)

  • Na Won-Bae;Ryu Yeon-Sun;Kim Jeong-Tae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.232-239
    • /
    • 2006
  • Guided wave techniques have been used for pipeline inspection because of the long range inspection capability of guided waves. One of main concerns of these technique is how ones decide the axial interval of sensors when they are utilized for pipeline inspection. This question is related to the characteristic of cylindrical guided wave propagation, especially wave attenuation. Thus, attenuation of fundamental longitudinal guided wave propagating liquid-filled steel pipes is numerically investigated in the paper. Several liquids such as water, diesel oil, castor oil etc. are considered for the filing materials in the pipes. Sink is considered for numerical models for abandoning standing wave modes; hence, the attenuation dispersion curves become much simpler. Those attenuation calculations can be utilized for guided-wave-based nondestructive testing of pipelines when one inspects pipelines, using monitoring sensors, which are installed outside pipes.

  • PDF

A Case of Recurrent Ventricular Tachycardia after Pimozide and Haloperidol Overdose (Pimozide와 Haloperidol 과량 복용 후 반복적으로 발생한 심실 빈맥 1례)

  • Jung, Jin-Hee;Jang, Hye-Young;Eo, Eun-Kyung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.1
    • /
    • pp.67-70
    • /
    • 2005
  • Pimozide and haloperidol are typical antipsychotics. They share a similarity in pharmacotherapeutic and adverse effect profiles. Cardiovascular effects may be seen as alterations in heart rate, blood pressure, and cardiac conduction. Conduction disturbances may occur ranging from asymptomatic prolongation of the QT interval to fatal ventricular arrhythmia. So in the case of anti psychotics overdose, the patient must be carefully monitored by continuous electrocardiography (ECG). We experienced a 34-year-old woman of schizophrenia with recurrent ventricular tachycardia after pimozide and haloperidol overdose. Initially she was slightly drowsy, however her ECG showed normal sinus rhythm. After 6 hours on emergency department entrance, her ECG monitoring showed ventricular tachycardia and we successfully defibrillated. There were five times events of ventricular arrhythmia during the in-hospital stay. She was discharged 5 days later without any other complications.

  • PDF

$\bar{X}$ control charts of automcorrelated process using threshold bootstrap method (분계점 붓스트랩 방법을 이용한 자기상관을 갖는 공정의 $\bar{X}$ 관리도)

  • Kim, Yun-Bae;Park, Dae-Su
    • Journal of Korean Society for Quality Management
    • /
    • v.28 no.2
    • /
    • pp.39-56
    • /
    • 2000
  • ${\overline{X}}$ control chart has proven to be an effective tool to improve the product quality. Shewhart charts assume that the observations are independent and normally distributed. Under the presence of positive autocorrelation and severe skewness, the control limits are not accurate because assumptions are violated- Autocorrelation in process measurements results in frequent false alarms when standard control chats are applied in process monitoring. In this paper, Threshold Bootstrap and Moving Block Bootstrap are used for constructing a confidence interval of correlated observations. Monte Carlo simulation studies are conducted to compare the performance of the bootstrap methods and that of standard method for constructing control charts under several conditions.

  • PDF

Video-based Walking Distance Measurement for the Visually Impaired (시각 장애인을 위한 비디오 기반 보행거리 측정)

  • Park, Su-Woo;Song, Byung-Seop;Do, Yong-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.2
    • /
    • pp.139-147
    • /
    • 2009
  • When the visually impaired walks inside a building like corridor, a GPS cannot be useful for the walker in estimating his or her position unlike the case of outdoor space. This paper presents two novel methods to measure the walking distance using a low cost camera worn on the chest of the visually impaired. In the first method we analyze the periodic variation of image focusing values. Walking steps are counted by checking the period for the rough measure of the walking distance. The second method counts the step number by monitoring fixtures on the ceiling, which have a certain interval. Lamps on the ceiling appeared on the video are monitored in this paper. The T-S fuzzy theory is used to detect lamps, and the walking steps are estimated by the positional variation of the lamp due to the gait of the walker. The two methods are tested in real experiment, and the results are compared.