• 제목/요약/키워드: monitoring display

검색결과 437건 처리시간 0.031초

Development of the HDTV Camera and Monitor for Stereoscopic 3D Display

  • Kim, Nam;Kwon, Ki-Chul;Park, Jae-Hyeung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1033-1036
    • /
    • 2008
  • In this paper, we describe the development of the polarized-light stereoscopic monitoring system based on full HDTV. The system consists of the stereoscopic camera part, image processing device for the stereoscopic image recording and stereoscopic display. The developed stereoscopic imaging display system reduces eyestrain and viewer fatigue.

  • PDF

윈도우즈 기반 영상 감시 시스템에서의 Tearing 현상 개선 (A Study on the Improvement of Tearing Artifact for Windows-Based Visual Monitoring Systems)

  • 정연권;이동학;정선태
    • 한국통신학회논문지
    • /
    • 제27권11C호
    • /
    • pp.1097-1105
    • /
    • 2002
  • 아날로그 모니터를 사용하는 디스플레이 시스템의 경우, 프레임 버퍼의 영상 정보 갱신 주기와 모니터 주사 주기가 맞지 않는 경우, 장면 변화가 심한 동영상 디스플레이시에 화면이 상단과 하단으로 다른 영상이 나타나는 tearing 현상이 발생한다. 다중 카메라 채널을 디스플레이하여야 하는 영상 감시 시스템인 DVR(Digital Video Recorder) 시스템에서는 프레임 버퍼 갱신율이 매우 높기 때문에 tearing 현상이 심하게 된다. 본 논문에서는 윈도우즈 기반 DVR에서 디스플레이 속도 성능의 저하가 별로 없으면서, tearing 현상을 방지한 개선된 디tm플레이 시스템 구조를 제안한다. 제안된 디스플레이 시스템의 효율성은 실험을 통하여 입증하였다.

원자로 제어봉구동장치 제어시스템용 이벤트 기록 방법 (Event Logging Method for Control Rod Control System)

  • 천종민;김춘경;조창희;정순현;남정한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.552-554
    • /
    • 2003
  • This paper is about the method by which Power Control Unit(PCU) of Control Rod Control System(CRCS) logs events in the system and the real-time monitoring display. This method enables the functions like the event logging of Control Rod Drive Mechanism(CRDM)/power Cabinet, the off-line show of the event data logged and the on-line show by communication between the PCU and the monitoring display. Operators in a nuclear power plant must be able to grasp any possible abnormal states correctly. Because our newly designed system has a good ability to log and display the kinds, tine, and the prior and posterior states of urgent or non-urgent events, the operators can judge, maintain and repair the abnormal event more easily.

  • PDF

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

진공 환경내 실시간 입자 모니터링 시스템의 개발 및 성능평가 (Development and Performance Test of In-situ Particle Monitoring System using Ion-counter in Vacuum Environments)

  • 안강호;김용민;권용택
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.45-49
    • /
    • 2006
  • In this paper, a new method that monitors the quantity of particles using ion-counter in vacuum environment is introduced. In-situ particle monitoring (ISPM) system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. The ion-counter applied by positive voltage detects only positive charged particles. Therefore the particles to be detected should be in known charge state for further data analysis. ion-counter is installed at the exhaust line of process equipment where the pressure loss is structurally low. ISPM system performance has been verified with SMPS (Scanning Mobility Particle Sizer) system. The correlation coefficient is above 0.98 at the particle size range of $20{\sim}300nm$ in diameter with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현 (Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX)

  • 양오;이헌국
    • 반도체디스플레이기술학회지
    • /
    • 제15권3호
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

발전소 운전 감시용 그래픽 디스플례이 및 오퍼레이터 console 시스템의 개발 (The Development of Graphic Display and Operator Console System for Monitoring the Operation of Power Plant)

  • 조영조;문봉채;김병국;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.216-220
    • /
    • 1987
  • A graphic display and operator console system is developed for monitoring the operation of power plant. It has multiprocessor structure using VME bus and common memory. The graphic monitoring system is applied to fault tolerant control system for enhancing reliability of boiler analog controller. As a result, it displays all the operating date as color graphic images with 14 pages. Moreover, it can transfer the operator commands to the other micro-processors through common memory.

  • PDF

산화 그래핀을 이용한 구리이온 흡착과 투과도 특성을 이용한 구리이온 농도 실시간 측정 (Cu Ions Removal Using Graphene Oxide and in-situ Spectroscopic Monitoring Method of Residual Cu Ions)

  • 김승두;류희중;오훈정;황완식
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.87-91
    • /
    • 2021
  • Various Cu ions are discharged into water from various industries, which results in a severe trouble for groundwater, soil, air, and eventually animals and humans. In this work, graphene oxide (GO) is introduced as a Cu removal absorber and the real-time monitoring method is demonstrated. The results show that GO is a very effective material to absorb Cu ions in the solution. In addition, the residual Cu ions in the solution is monitored via optical transmittance method, which well match with Inductively Coupled Plasma Mass Spectrometer (ICP-MS) analysis.

Effective Characterization Methods of Polycrystalline Silicon Films Fabricated by Ni Induced Crystallization

  • Koo, Hyun-Woo;Maidanchuk, Ivan;Jung, Jae-Wan;Lee, Ki-Yong;Berkeley, Brian H.;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.250-253
    • /
    • 2009
  • Effective methods for monitoring the quality of polycrystalline silicon (poly-Si) films are discussed. Raman spectroscopy is typically used to determine crystallinity of poly-Si, but this method has limitations for data gathering on large substrates for mass production of poly-Si TFT backplanes. Spectroscopic ellipsometry is proposed as an alternative for fast and simple estimation of poly-Si quality on large substrates. By using both ellipsometry and Raman spectroscopy, it is possible to determine whether the quality and uniformity of the poly-Si films meet the criteria required for mass production of TFT backplanes for AMOLED panels.

  • PDF

Display System Design Based On The Abstraction Hierarchy

  • Sohn, Kwang-Young;Shin, Hyun-Kook
    • Nuclear Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.339-348
    • /
    • 1996
  • Plant monitoring algorithm developments seem to be saturated which means that display system to show the results from the algorithm should be the well-defined and interactive tools for operator's diagnosing, controlling, restoring the abnormal plant situations. On the other hand, very little generalized display design concepts and evaluations are available. Events that are unfamiliar to operators and that has not been anticipated by designers may cause great threats to the nuclear power plant system safety operation. The abstraction hierarchy, considered most popular display design methodology but not generalized for nuclear power plant design space, has ken proposed as a representation frame work that can be adopted to design interfaces and supports operators in diagnosing overlooked events that should have been considered to operate plant safely. However most practical plant display systems do not fully stick to this design concept but partially rely on their philosophy from design experiences. Abstraction hierarchy display design concept will be do scribed and the trend of Advanced Control Room(ACR) CRT design will also be presented with the conventional display for the several type of plants. Consequently this complementary material should be of interest to designer and regulators concerned with nuclear power plant.

  • PDF