• Title/Summary/Keyword: monitoring

Search Result 26,335, Processing Time 0.071 seconds

A Monitoring of Aflatoxins in Commercial Herbs for Food and Medicine (식·약공용 농산물의 아플라톡신 오염 실태 조사)

  • Kim, Sung-dan;Kim, Ae-kyung;Lee, Hyun-kyung;Lee, Sae-ram;Lee, Hee-jin;Ryu, Hoe-jin;Lee, Jung-mi;Yu, In-sil;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.267-274
    • /
    • 2017
  • This paper deals with the natural occurrence of total aflatoxins ($B_1$, $B_2$, $G_1$, and $G_2$) in commercial herbs for food and medicine. To monitor aflatoxins in commercial herbs for food and medicine not included in the specifications of Food Code, a total of 62 samples of 6 different herbs (Bombycis Corpus, Glycyrrhizae Radix et Rhizoma, Menthae Herba, Nelumbinis Semen, Polygalae Radix, Zizyphi Semen) were collected from Yangnyeong market in Seoul, Korea. The samples were treated by the immunoaffinity column clean-up method and quantified by high performance liquid chromatography (HPLC) with on-line post column photochemical derivatization (PHRED) and fluorescence detection (FLD). The analytical method for aflatoxins was validated by accuracy, precision and detection limits. The method showed recovery values in the 86.9~114.0% range and the values of percent coefficient of variaton (CV%) in the 0.9~9.8% range. The limits of detection (LOD) and quantitation (LOQ) in herb were ranged from 0.020 to $0.363{\mu}g/kg$ and from 0.059 to $1.101{\mu}g/kg$, respectively. Of 62 samples analyzed, 6 semens (the original form of 2 Nelumbinis Semen and 2 Zizyphi Semen, the powder of 1 Nelumbinis Semen and 1 Zizyphi Semen) were aflatoxin positive. Aflatoxins $B_1$ or $B_2$ were detected in all positive samples, and the presence of aflatoxins $G_1$ and $G_2$ were not detected. The amount of total aflatoxins ($B_1$, $B_2$, $G_1$, and $G_2$) in the powder and original form of Nelumbinis Semen and Zizyphi Semen were observed around $ND{\sim}21.8{\mu}g/kg$, which is not regulated presently in Korea. The 56 samples presented levels below the limits of detection and quantitation.

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

Soluble IL-2R, IFN-$\gamma$ and Neopterin as Immunologic Markers in Patients with Tuberculosis (결핵 환자에서 면역학적 지표로서의 sIL-2R, IFN-$\gamma$, Neopterin에 관한 연구)

  • Ryu, Yon-Ju;Ryu, Kum-Hei;Kim, Su-Hyun;Lee, Jong-Soo;Cheon, Seon-Hee;Seoh, Ju-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.3
    • /
    • pp.294-308
    • /
    • 2002
  • Background : The cell-mediated immune response plays an important role in tuberculosis. After being activated by mycobacterial antigens, T lymphocytes express a high affinity receptor (IL-2R) for interleukin-2 (IL-2) on their own surface and release a soluble fraction of the IL-2 receptor (sIL-2R) from the cell membrane into the circulation. Neopterin is a metabolite of guanosine-triphosphate, which is produced by stimulated macrophages under the influence of IFN-$\gamma$ with a T lymphocyte origin. Therefore, the utility of sIL-2R, IFN-$\gamma$ and the neopterin levels as immunologic indices of the cell-mediated immune response and severity of disease in patients with pulmonary tuberculosis was assessed. Methods : The serum sIL-2R, IFN-$\gamma$ and neopterin levels were measured in 39 patients with pulmonary tuberculosis, 6 patients with tuberculous lymphadenitis prior to treatment and 10 healthy subjects. The serum and pleural sIL-2R, neopterin and ADA levels were measured in 22 patients with tuberculous pleurisy. The patients with pulmonary tuberculosis were divided into a mild, moderate and severe group according to the severity by ATS guidelines. To compare the results from these patients with those of the pretreatment levels, the sIL-2R, IFN-$\gamma$ and neopterin levels were measured in 36 of the 39 patients(1 patient, expired; 2 patients were referred to a sanitarium) with pulmonary tuberculosis after 2 months of treatment. Results : 1) the serum sIL-2R and IFN-$\gamma$ levels were elevated in patients with tuberculosis when compared to those of healthy subjects (p>0.05). The neopterin concentration in the serum was significantly lower in patients with pulmonary tuberculosis($2967{\pm}2132.8$ pg/ml) than in healthy controls($4949{\pm}1242.1$ pg/ml)(p<0.05). 2) In the pulmonary tuberculosis group, the serum sIL-2R and IFN-$\gamma$ levels were higher in patients with severe disease than those in patients with mild and moderate disease. However, the neopterin levels declined as the pulmonary tuberculosis became more severe (p<0.01). 3) The mean serum sIL-2R and IFN-$\gamma$ levels declined from $1071{\pm}1139.4$ U/ml to $1023{\pm}1920.9$ U/ml(p>0.05), $41{\pm}52.8$ pg/ml to $22{\pm}23.9$ gm/ml(p<0.05), respectively, after 2 month of treatment. The mean serum neopterin levels increased from $3158{\pm}2272.6$ pg/ml to $3737{\pm}2307.5$ pg/ml(p>0.05) after a 2 month of treatment. These findings were remarkable in the severe group of pulmonary tuberculosis with a clinical correlation. 4) In the patients with tuberculous pleurisy, the serum sIL-2R and ADA were significantly higher than those in the pleural fluid, However, the neopterin levels in the sera and pleural effusion were similar. Conclusion : On the basis of this study, sIL-2R, IFN-$\gamma$ and neopterin measurements may not only provide an insight into the present state of the cell-mediated immune response, but also serve as parameters monitoring of the prognosis of the disease, particularly in patients with severe pulmonary tuberculosis. In addition, an assay of the pleural sIL-2R levels might signal a stimulated local immunity including T cell activation in the tuberculous pleural effusion.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

The Influence of Obstructive Sleep Apnea on Systemic Blood Pressure, Cardiac Rhythm and the Changes of Urinary (폐쇄성 수면 무호흡이 전신성 혈압, 심조율 및 요 Catecholamines 농도 변화에 미치는 영향)

  • Lo, Dae-Keun;Choi, Young-Mee;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.153-168
    • /
    • 1998
  • Background: The existing data indicate that obstructive sleep apnea syndrome contributes to the development of cardiovascular dysfunction such as systemic hypertension and cardiac arrhythmias, and the cardiovascular dysfunction has a major effect on high long-term mortality rate in obstructive sleep apnea syndrome patients. To a large extent the various studies have helped to clarify the pathophysiology of obstructive sleep apnea, but many basic questions still remain unanswered. Methods: In this study, the influence of obstructive sleep apnea on systemic blood pressure, cardiac rhythm and urinary catecholamines concentration was evaluated. Over-night polysomnography, 24-hour ambulatory blood pressure and ECG monitoring, and measurement of urinary catecholamines, norepinephrine (UNE) and epinephrine (UEP), during waking and sleep were undertaken in obstructive sleep apnea syndrome patients group (OSAS, n=29) and control group (Control, n=25). Results: 1) In OSAS and Control, UNE and UEP concentrations during sleep were significantly lower than during waking (P<0.01). In UNE concentrations during sleep, OSAS showed higher levels compare to Control (P<0.05). 2) In OSAS, there was a increasing tendency of the number of non-dipper of nocturnal blood pressure compare to Control (P=0.089). 3) In both group (n=54), mean systolic blood pressure during waking and sleep showed significant correlation with polysomnographic data including apnea index (AI), apnea-hypopnea index (AHI), arterial oxygen saturation nadir ($SaO_2$ nadir) and degree of oxygen desaturation (DOD). And UNE concentrations during sleep were correlated with AI, AHI, $SaO_2$ nadir, DOD and mean diastolic blood pressure during sleep. 4) In OSAS with AI>20 (n==14), there was a significant difference of heart rates before, during and after apneic events (P<0.01), and these changes of heart rates were correlated with the duration of apnea (P<0.01). The difference of heart rates between apneic and postapneic period (${\Delta}HR$) was significantly correlated with the difference of arterial oxygen saturation between before and after apneic event (${\Delta}SaO_2$) (r=0.223, P<0.001). 5) There was no significant difference in the incidence of cardiac arrhythmias between OSAS and Control In Control, the incidence of ventricular ectopy during sleep was significantly lower than during waking. But in OSAS, there was no difference between during waking and sleep. Conclusion : These results suggested that recurrent hypoxia and arousals from sleep in patients with obstructive sleep apnea syndrome may increase sympathetic nervous system activity, and recurrent hypoxia and increased sympathetic nervous system activity could contribute to the development of cardiovascular dysfunction including the changes of systemic blood pressure and cardiac function.

  • PDF

A Comparative Study of Food Habits and Body Satisfaction of Middle School Students According to Clinical Symptoms (일부 남녀 중학생의 건강 관련 임상증상에 따른 식습관과 체헝관심도에 관한 연구)

  • Sung, Chung-Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.2
    • /
    • pp.202-208
    • /
    • 2005
  • This study was conducted to examine the food habits, knowledge of nutrition and actual conditions of food ingestion of adolescent middle school students according to questionnaire answers. Questionnaires were completed by 524 students, divided into a healthy group (n=289) and an unhealthy group (n=235) according to clinical signs. Further questions were asked of the two groups in the areas of food habits, knowledge of nutrition and nutritional attitude. The results were as follows: Mean age of all subjects was 14, heights for male and female students were 162.0 em, and 157.2 cm, weights were 53.4 kg, and 49.4, respectively. Heights and weights of male students were greater than those of female students. The body mass index (BMI) for male and female students was 20.3 kg/$m^2$ and 20.0 kg/$m^2$, respectively, and all data were within normal ranges. There were no significant differences in mean age, height, weight, and BMI between the healthy and unhealthy groups. There was no significant difference in body image recognition between the two groups, although the ratio of dissatisfaction with their own body shape was significantly higher in the female unhealthy group (46.1%), than in the female healthy group (33.0%) (p<0.05). In the area of the struggle to control body weight during the previous year, the female unhealthy group (59.4%) was higher than the female healthy group (38.4%) (p<0.01). There was no significant difference in the scores between the two groups in the areas of knowledge of nutrition and the nutritional attitude. Meal frequency and meal patterns were showed that having breakfast less than 4x/week was significantly higher in the female unhealthy group (44.0%), than in the female healthy group (30.7%) (p<0.01). Meal frequency for suppers<4x/week showed that the female unhealthy group (18.8%) was also higher than the female healthy group (10.7%). Therefore, the unhealthy group exhibited a higher pattern of missing both breakfast and supper. The male unhealthy group (16.7%) dined out more frequently than the male healthy group (12.3%) (p<0.01), and female unhealthy group also indulged in snacking significantly more frequently than the female healthy group. The unhealthy group also ate only 1 item for meals more frequently than the healthy group and no significant difference. The conclusion of this study is that adolescent Korean middle school students, who showed a higher incidence of clinical symptoms, representing an unhealthy status, missed breakfast and supper, and dined out and indulged in snacking more frequently. Their quality of breakfast and satisfaction of body image were also lower than the healthy group. These results indicated that there is a high correlation between a Korean adolescent's health status, food habits and body image satisfaction. It is recommended that a more intense program of nutritional education and monitoring be introduce into the current Korean middle-school system in order to optimally support and maximize the health potential of the current population of Korean student.

Comparison of Imposed Work of Breathing Between Pressure-Triggered and Flow-Triggered Ventilation During Mechanical Ventilation (기계환기시 압력유발법과 유량유발법 차이에 의한 부가적 호흡일의 비교)

  • Choi, Jeong-Eun;Lim, Chae-Man;Koh, Youn-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.592-600
    • /
    • 1997
  • Background : The level of imposed work of breathing (WOB) is important for patient-ventilator synchrony and during weaning from mechanical ventilation. Triggering methods and the sensitivity of demand system are important determining factors of the imposed WOB. Flow triggering method is available on several modern ventilator and is believed to impose less work to a patient-triggered breath than pressure triggering method. We intended to compare the level of imposed WOB on two different methods of triggering and also at different levels of sensitivities on each triggering method (0.7 L/min vs 2.0 L/min on flow triggering ; $-1\;cmH_2O$ vs $-2cm\;H_2O$ on pressure triggering). Methods : The subjects were 12 patients ($64.8{\pm}4.2\;yrs$) on mechanical ventilation and were stable in respiratory pattern on CPAP $3\;cmH_2O$. Four different triggering sensitivities were applied at random order. For determination of imposed WOB, tracheal end pressure was measured through the monitoring lumen of Hi-Lo Jet tracheal tube (Mallincrodt, New York, USA) using pneumotachograph/pressure transducer (CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). Other data of respiratory mechanics were also obtained by CP-100 pulmonary monitor. Results : The imposed WOB was decreased by 37.5% during 0.7 L/min on flow triggering compared to $-2\;cmH_2O$ on pressure triggering and also decreased by 14% during $-1\;cmH_2O$ compared to $-2\;cmH_2O$ on pressure triggering (p < 0.05 in each). The PTP(Pressure Time Product) was also decreased significantly during 0.7 L/min on flow triggering and $-1\;cmH_2O$ on pressure triggering compared to $-2\;cmH_2O$ on pressure triggering (p < 0.05 in each). The proportions of imposed WOB in total WOB were ranged from 37% to 85% and no significant changes among different methods and sensitivities. The physiologic WOB showed no significant changes among different triggering methods and sensitivities. Conclusion : To reduce the imposed WOB, flow triggering with sensitivity of 0.7 L/min would be better method than pressure triggering with sensitivity of $-2\;cm\;H_2O$.

  • PDF

The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP (Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과)

  • Chin, Jae-Yong;Lim, Chae-Man;Koh, Youn-Suck;Park, Pyung-Whan;Choi, Jong-Moo;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.201-209
    • /
    • 1996
  • Background : Auto-PEEP which develops when expiratory lung emptying is not finished until the beginning of next inspiration is frequently found in patients on mechanical ventilation. Its presence imposes increased risk of barotrauma and hypotension, as well as increased work of breathing (WOB) by adding inspiratory threshold load and/or adversely affecting to inspiratory trigger sensitivity. The aim of this study is to evaluate the relationship of auto-PEEP with WOB and to evaluate the effect of PEEP applied by ventilator (external PEEP) on WOB in patients with auto-PEEP. Method : 15 patients, who required mechanical ventilation for management of acute respiratory failure, were studied. First, the differences in WOB and other indices of respiratory mechanics were examined between 7 patients with auto-PEEP and 8 patients without auto-PEEP. Then, we applied the 3 cm $H_2O$ of external PEEP to patients with auto-PEEP and evaluated its effects on lung mechanics as well as WOB. Indices of respiratory mechanics including tidal volume ($V_T$), repiratory rate, minute ventilation ($V_E$), peak inspiratory flow rate (PIFR), peak expiratory flow rate (PEFR), peak inspiratory pressure (PIP), $T_I/T_{TOT}$, auto-PEEP, dynamic compliance of lung (Cdyn), expiratory airway resistance (RAWe), mean airway resistance (RAWm), $p_{0.1}$, work of breathing performed by patient (WOB), and pressure-time product (PTP) were obtained by CP-100 Pulmonary Monitor (Bicore, USA). The values were expressed as mean $\pm$ SEM (standard error of mean). Results : 1) Comparison of WOB and other indices of respiratory mechanics in patients with and without auto-PEEP : There was significant increase in WOB ($l.71{\pm}0.24$ vs $0.50{\pm}0.19\;J/L$, p=0.007), PTP ($317{\pm}70$ vs $98{\pm}36\;cm$ $H_2O{\cdot}sec/min$, p=0.023), RAWe ($35.6{\pm}5.7$ vs $18.2{\pm}2.3\;cm$ H2O/L/sec, p=0.023), RAWm ($28.8{\pm}2.5$ vs $11.9{\pm}2.0cm$ H2O/L/sec, p=0.001) and $P_{0.1}$ ($6.2{\pm}1.0$ vs 2.9+0.6 cm H2O, p=0.021) in patients with auto-PEEP compared to patients without auto-PEEP. The differences of other indices including $V_T$, PEFR, $V_E$ and $T_I/T_{TOT}$ showed no significance. 2) Effect of 3 cm $H_2O$ external PEEP on respiratory mechanics in patients with auto-PEEP : When 3 cm $H_2O$ of external PEEP was applied, there were significant decrease in WOB ($1.71{\pm}0.24$ vs $1.20{\pm}0.21\;J/L$, p=0.021) and PTP ($317{\pm}70$ vs $231{\pm}55\;cm$ $H_2O{\cdot}sec/min$, p=0.038). RAWm showed a tendency to decrease ($28.8{\pm}2.5$ vs $23.9{\pm}2.1\;cm$ $H_2O$, p=0.051). But PIP was increased with application of 3 cm $H_2O$ of external PEEP ($16{\pm}2$ vs $22{\pm}3\;cm$ $H_2O$, p=0.008). $V_T$, $V_E$, PEFR, $T_I/T_{TOT}$ and Cdyn did not change significantly. Conclusion : The presence of auto-PEEP in mechanically ventilated patients was accompanied with increased WOB performed by patient, and this WOB was decreased by 3 cm $H_2O$ of externally applied PEEP. But, with 3 cm $H_2O$ of external PEEP, increased PIP was noted, implying the importance of close monitoring of the airway pressure during application of external PEEP.

  • PDF

Human Parathyroid Hormone-Related Peptide Measurement in the Lung Cancer Patients (폐암환자에서 인체 부갑상선 호르몬 관련 단백에 대한 연구)

  • Chang, Joon;Kim, Se-Kyu;Lim, Sung-Kil;Lee, Hong-Lyeol;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.855-861
    • /
    • 1995
  • Background: Parathyroid hormone-related protein(PTHrp) was first identified as the cause of hypercalcemia in malignancy. Hypercalcemia can be found in malignancy, especially in the epidermoid carcinoma of the lung, even without extensive metastases to the bones. The application of sensitive assays for PTHrp may help in the early diagnosis of lung cancer, in the monitoring of treatment and in the detection of recurrence. Method: Serum PTHrp was measured by radioimmunoassay detecting the N-terminal 1~34 peptide of human PTHrp(PTHrp 1-34) in 63 histologically confirmed lung cancer patients and 22 healthy controls. Result: Serum PTHrp(mean$\pm$S.E.) was $312{\pm}68.9pg/ml$ in 63 lung cancer patients and $158{\pm}38.2pg/ml$ in 22 controls(p>0.05). PTHrp was $356{\pm}103.9pg/ml$ in 34 epidermoid carcinoma patients, $281{\pm}148.7pg/ml$ in 15 adenocarcinoma patients and $316{\pm}140.8pg/ml$ in 9 small cell carcinoma patients. In epidermoid carcinoma patients, PTHrp was $570{\pm}472.3pg/ml$ in stage II(n=3; p<0.05 vs controls), $166{\pm}22.4pg/ml$ in stage IIIa(n=9), $282{\pm}113.3pg/ml$ in stage IIIb(n=12) and $668{\pm}367.9pg/ml$ in stage IV(n=9; p<0.05 vs controls). PTHrp was significantly increased in 8 epidermoid carcinoma patients with bone metastases($1526{\pm}811.2\;pg/ml$; p<0.0005 vs controls). Hypercalcemia was observed in an epidermoid carcinoma patient whose PTHrp value was 244 pg/ml. Conclusion: The serum PTHrp was increased in advanced epidermoid carcinoma patients even without hypercalcemia. The measurement of PTHrp may be not helpful in the early diagnosis of lung cancer. But the lung cancer should be suspected in the marked elevation of PTHrp. It may be of value in detecting patients of advanced diseases with bone metastases or patients who might develop the malignancy associated hypercalcemia.

  • PDF

Clinical Efficacy of Erdosteine in Patients with Acute or Chronic Bronchitis -A Randomized, Double Blind, Comparative Study vs. Ambroxol- (급.만성 기관지염 환자에서 엘도스$^{(R)}$(Erdosteine)의 임상효과 -염산 암브록솔과의 무작위 이중맹검 비교시험-)

  • Kim, Seok-Chan;Lee, Sang-Hoak;Song, So-Hyang;Kim, Young-Kyoon;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1296-1307
    • /
    • 1997
  • Background : Erdosteine is a thiol derivative developed for the treatement of chronic obstructive bronchitis, including acute infective exacerbation of chronic bronchitis. Erdosteine has mucomodulating and antioxidant properties and especially exhibits excellent gastrointestinal tolerability. Methods : The study was conducted as a prospective evaluation, with 2 comparative groups orally treated with erdosteine 300mg (bid.) or ambroxol 30mg (b.i.d.) for 7 days and the design of trial was double-blind. The treatments have been assigned randomly to patients (n=80) with acute or chronic bronchitis. The primary end-point used to determine efficacy in this study was subjective symptoms including expectorating frequence, expectoration volume, expectorating difficulty, expectoration viscosity, cough intensity and dyspnea. The secondary end-points of efficacy was the result of arterial blood gas analysis and pulmonary function test. Safety was evaluated with adverse drug reactions and laboratory tests monitoring. 61 patients was included in the efficacy analysis, due to the fact that 19 patients drop-out for different reasons. The obtained values have been analyzed with paired Hest., ANOVA test., multivariate $t^2$-test, repeated measures analysis of covariance, two sample t-test, loglinear-logit model analysis, Fisher's exact test. Results : 1) There was no significant difference on demographic data and vital signs between erdosteine and ambroxol treated groups. 2) The comparison between erdosteine and ambroxol treated groups showed no significant difference in improvement of each symptom in spite of the more favorable efficacy obtained with erdosteine. No difference on the contrary was observed for arterial blood gas analysis and pulmonary function test. 3) As safety is concerned, no clinical significant changes in laboratory test and symptom were induced in erdosteine and ambroxol treated group and two patients in ambroxol treated group drop-out for adverse reactions in symptom. 4) In the evaluation of final clinical efficacy, erdosteine improved more effectively patient's overall symptoms {very good effect (11/31), good effect (12/31), moderate effect (6/31), no effect (2/31), aggravation (0/31)} than ambroxol {very good effect (6/30), good effect (14/30), moderate effect (5/30), no effect (4/30), aggravation (2/30)}. And the probability of symptomatic improvement by erdosteine compared to ambroxol was 2.5 times. (p<0.05). Conclusion : This study showed that erdosteine was clinically effective and safe drug for treatment of acute and chronic bronchitis.

  • PDF