• Title/Summary/Keyword: monitor

Search Result 7,292, Processing Time 0.081 seconds

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

Validity of Clinically Used Tray Transmission Factor (임상적으로 쓰이는 차폐선반투과율의 타당성에 관한 연구)

  • 윤형근
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.218-224
    • /
    • 2003
  • Purpose:By evaluating the dependence of the tray transmission factor (tray factor) on collimator setting and tray thickness, we determined the validity of the clinically used single tray factor for standard radiation field size (10${\times}$10 $\textrm{cm}^2$). Methods and Materials:For each X ray energies (6 and 10 MV), outputs were measured by using 5 steps of tray thickness (0, 6, 8, 10, 12 mm) and 7 steps of radiation field size (5${\times}$5, 10${\times}$10, 15${\times}$15, 20${\times}$20, 25${\times}$25, 30${\times}$30, 35${\times}$35 $\textrm{cm}^2$) at 10 cm phantom depth. Outputs were measured in both 'with tray' and 'without tray' conditions by using radiation with the same monitor units, and the tray factors were determined by the ratios of the two outputs. To evaluate the validity of a single tray factor obtained for standard radiation field, we analyzed the pattern of the field sizes in cases treated at our hospital in 2002. Results : In the 6 MV X-ray, the increases in the tray factor between the standard field (l0${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.835%, 1.058%, 1.066% in 6, 8, 10, and 12 mm thickness tray, respectively. In the 10 MV X-ray, the increases in the fray factor between the standard field (10${\times}$10 $\textrm{cm}^2$) and the largest field (35${\times}$35 $\textrm{cm}^2$) were 0.517%, 0.836%, 1.058%, 1.066% in 6, 8, 10, 12 mm thickness tray, respectively. In a major portion of clinical cases, when the field size was smaller than 20${\times}$20 $\textrm{cm}^2$, the tray factor was in good agreement with the standard tray factor. However, in cases where the field sizes were 30${\times}$30 $\textrm{cm}^2$ and 35${\times}$35 $\textrm{cm}^2$, the error could exceed 1.0%. Conclusion:The tray factor increased with increasing field size or decreasing tray thickness. The difference of tray factor between the small field and the large field increased with increasing tray thickness. Furthermore, the standard tray factor was valid in most clinical cases except for when the field size was greater than 30${\times}$30 $\textrm{cm}^2$, wherein the error could exceed 1.0%.

  • PDF

Nocturnal Arterial Oxygen Saturation Monitoring in Patients with Respiratory Disease (호흡기 질환 환자들에서 야간 동맥혈 산소포화도 감시 성적)

  • Choi, In-Seon;Yang, Jae-Beom;Kim, Young-Chul;Chung, Ik-Joo;Kang, Yu-Ho;Koh, Yeoung-Il;Park, Sang-Seon;Lee, Min-Su;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.103-110
    • /
    • 1994
  • To find out the predictors of nocturnal arterial oxygen desaturation in patients with respiratory diseases, transcutaneous oxygen saturation($StcO_2$) monitoring studies using a pulse oximeter were performed during sleep in 20 patients. $StcO_2$ was decreased more than 4% from the baseline value in 18 patients(90%) and more than 10%("Desaturator") in 8(40%). Five of the seven patients(71.4%) with awake $PaO_2$<60mmHg and three of the thirteen patients(23.1%) with awake $PaO_2{\geq}60mmHg$ were "desaturators". The awake $PaO_2/FIO_2$ and $PaO_2/PAO_2$ could distinguish "desaturator" from "nondesaturator", and $PaO_2,\;SaO_2$ or $StcO_2$ could not. These results suggest that the nocturnal oxygen desaturation depends on the severity of the underlying disease rather than the baseline $PaO_2$. Anthropomorphic and lung function factors could not separate between "desaturator" and "non-desaturator", and about a quater of patients with a wake $PaO_2{\geq}60mmHg$ developed significant desaturation. Therefore, it is necessary to monitor the nocturnal arterial oxygen saturation in patients with respiratory diseases regardless of their severity of airflow obstruction or awake $PaO_2$.

  • PDF

Peak Expiratory Flow in Normal Healthy Korean Subjects Measured by Mini-Wright Peak Flow Meter (Mini-Wright Peak Flow Meter로 측정한 한국 성인의 최고호기유량의 정상치)

  • Kim, Young-Sam;Ahn, Ae-Ran;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Oh, Jai-Joon;Kim, Sung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.320-333
    • /
    • 2001
  • Background : Peak expiratory flow (PEF) provides a simple, quantitative, and reproducible measure of the existence and severity of airflow obstructions. Peak flow meters are designed to monitor the condition asthma patients. There are many reports showing the normal predicted value of PEF in other countries. Studies on healthy Korean adults have been performed in a relatively small sample number and a lower limit for the normal value was not reported. Therefore, an attempt to provide normal predictive PEF value with a lower limit was made. Method : The PEF(Mini-Wright Peak Flow Meter) measurements and spirometry were done in 233 men and 631 women without history of respiratory disease. All subjects were non-smokers with no respiratory symptoms. The normal predictive value and its lower limit were developed by multiple regression analysis. The result was compared with regression equations in other reports. Results : The regression equation for the normal PEF predictive value(L/min) is $25.117+4.587{\times}$Age(year)-$0.064{\times}Age^2+2.931{\times}$Height(cm) in men($R^2=025$), and 146.942-$0.011{\times}Age^2+1.795{\times}$Height(cm)+$0.836{\times}$Weight(kg) in women($R^2=0.21$). The regression equation for the lower limit of this value (L/min) is $25.117+4.587{\times}$Age(year)-$0.064{\times}Age^2+1.936{\times}$Height(cm) in men, and $146.942-0.011{\times}Age^2+1.232{\times}$Height(cm)+$0.481{\times}$Weight(kg) in women. The residuals were normally distributed. The PEF in Korean males was sililar to those reported in British and Japanese subjects. The PEF in Korean females was similar to that in British subjects, but higher than the PEF in Japanese subjects. The lower limit of normal value was 71% of normal predictive PEF value in men and 76% in women. Conclusion : The normal predictive PEF value and its lower limit was measured from 233 male and 631 female asymptomatic, lifelong non-smoking participants. The normal predictive value was different from those of other studies on Korean subjects. Therefore, further studies are required.

  • PDF

A Survey on Added Sugar Intakes from Snacks and Participation Behaviors of Special Event Days Sharing Sweet Foods among Adolescents in Korea (청소년의 간식을 통한 첨가당섭취량 및 고당류식품 관련 이벤트 데이 참여행동에 대한 조사)

  • Kim, Hyun-Ju;Kim, Sun-Hyo
    • Journal of Nutrition and Health
    • /
    • v.42 no.2
    • /
    • pp.135-145
    • /
    • 2009
  • This study was performed to investigate added sugar intakes from processed food-snacks and participation behaviors of special event days sharing sweet foods among adolescents in Korea. Questionnaire survey (n = 959), dietary survey (n = 71) by food record method for 3 days, and snack survey (n = 230) for 3 days were carried out, and subjects were overlapped among three surveys. As a result, middle school students (MS) preferred milks and fermented milks while high school students (HS) preferred breads and fast foods as a snack (p < 0.01). MS and HS took snacks three to six times a week, and HS took snacks more frequently than MS (p < 0.05). Most subjects participated in special event days sharing sweet foods such as friend's birthday (68.4%), Peppro's day (61.5%) and Valentine's day (42.6%). As for merits of these events, MS said ‘they could get along with their friends' and ‘relieve stress', while HS said ‘they could enjoy their own events' and ‘confess their affection to whom they like' (p < 0.01). A group of cookies, biscuits, breads and, cakes was major source of added sugars followed by beverages, sweet jellies of red bean, chocolates and candies for subjects. For MS and HS, daily total added sugar intakes from whole processed food-snacks were $30.5{\pm}23.5g/d$ (3.0-137.9 g/d) and $31.7{\pm}23.2g/d$ (1.2-126.1 g/d), and ratios of daily total energy taken from added sugars of whole processed food-snacks in proportion to daily total energy taken from diet (energy percent of added sugars from snacks) were $6.3{\pm}4.7%$ (0.6-26.1%) and $6.3{\pm}4.4%$ (0.3-23.9%), respectively. These results showed that subjects frequently participated in special event days sharing sweet foods. In addition, energy percent of added sugars from snacks was more than the UL suggested by WHO/FAO for some subjects. Therefore, it is highly critical to monitor adolescents' sugar intakes on a long-term basis and to take nutritional management on their high sugar intakes.

Lead Concentrations of Pigeon's Tissue as Indicator of Lead pollution in Air and Soil (대기 및 토양 오염의 지표로서 비둘기 조직의 연농도)

  • Byun, Yung-Woo;Hwang, Tae-Yoon;Lee, Jung-Jeung;Kim, Chang-Yoon;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.15-26
    • /
    • 1996
  • It has been studied that a variety of fauna and flora are sensitive biological indicators which reflect the severity of regional pollution of heavy metals, but in the center of part of Taegu City the controversial issue of lead poisoning attributable to the atmosphere which contains an increased concentrations of lead has been raised recently, it is usually hard to find suitable plants or animal in the areas with heavy traffic. Pigeons are ubiquitous in and around Taegu City area, inhabiting even the most densely populated areas with heavy traffic. With its small body size, high metabolic turnover, and rather limited mobility, a pigeon, as a biological indicator is expected. This study was conducted to monitor lead pollution in the Taegu and Kyongju City in Korea. We measured the lead content of the various tissue of three groups of feral pigeon(Columba livia) and soil and atmospheric lead concentration. First group was obtained in heavy traffic area in Taegu City, the second group was obtained a park in Taegu City and the third group was obtained light traffic area in Kyongju City. The air and soil lead concentration of heavy traffic area in Taegu City was $0.11{\mu}g/m^3,\;4.96{\mu}g/g$, that of park in Taegu City was $0.05{\mu}g/m^3,\;2.65{\mu}g/g$ and that of light traffic area in Kyongju City was $0.03{\mu}g/m^3,\;0.01{\mu}g/g$. The lead content of lung, blood, kidney, femur and liver of feral pigeons in heavy traffic area in Taegu City was significantly higher than pigeons obtained in a park in Taegu City and low traffic density area in Kyongju City(p<0.01). But stomach lead content of three group did not reflect a significant difference. In this study positive correlation was found between atmospheric lead concentrations and the concentration of lead in the pigeon's lung(r=0.5040, p<0.001), blood(r=0.3322, p<0.01), kidney(r=0.4824, p<0.001), femur(r=0.7214, p<0.001) and liver(r=0.4836, p<0.01). We can also found positive correlation between soil lead concentrations and the concentration of lead in the pigeon's femur(r=0.4850, p<0.001), kidney(r=0.4850, p<0.001) and liver(r=0.4386, p<0.01). In the pigeon's tissue there were significant correlations between concentration of lead in the blood and kidney(r=4818, p<0.001), femur(r=0.6157, p<0.001) and liver(r=0.3889, p<0.001). In conclusion, at the heavy traffic area in Taegu City, lead concentrations found in the atmosphere and soil are reflected in the lead concentrations of different tissue of urban pigeons. It is suggested that the tissue of pigeons can be good biological indicators of environmental lead pollution.

  • PDF

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

A Monitoring of Aflatoxins in Commercial Herbs for Food and Medicine (식·약공용 농산물의 아플라톡신 오염 실태 조사)

  • Kim, Sung-dan;Kim, Ae-kyung;Lee, Hyun-kyung;Lee, Sae-ram;Lee, Hee-jin;Ryu, Hoe-jin;Lee, Jung-mi;Yu, In-sil;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.267-274
    • /
    • 2017
  • This paper deals with the natural occurrence of total aflatoxins ($B_1$, $B_2$, $G_1$, and $G_2$) in commercial herbs for food and medicine. To monitor aflatoxins in commercial herbs for food and medicine not included in the specifications of Food Code, a total of 62 samples of 6 different herbs (Bombycis Corpus, Glycyrrhizae Radix et Rhizoma, Menthae Herba, Nelumbinis Semen, Polygalae Radix, Zizyphi Semen) were collected from Yangnyeong market in Seoul, Korea. The samples were treated by the immunoaffinity column clean-up method and quantified by high performance liquid chromatography (HPLC) with on-line post column photochemical derivatization (PHRED) and fluorescence detection (FLD). The analytical method for aflatoxins was validated by accuracy, precision and detection limits. The method showed recovery values in the 86.9~114.0% range and the values of percent coefficient of variaton (CV%) in the 0.9~9.8% range. The limits of detection (LOD) and quantitation (LOQ) in herb were ranged from 0.020 to $0.363{\mu}g/kg$ and from 0.059 to $1.101{\mu}g/kg$, respectively. Of 62 samples analyzed, 6 semens (the original form of 2 Nelumbinis Semen and 2 Zizyphi Semen, the powder of 1 Nelumbinis Semen and 1 Zizyphi Semen) were aflatoxin positive. Aflatoxins $B_1$ or $B_2$ were detected in all positive samples, and the presence of aflatoxins $G_1$ and $G_2$ were not detected. The amount of total aflatoxins ($B_1$, $B_2$, $G_1$, and $G_2$) in the powder and original form of Nelumbinis Semen and Zizyphi Semen were observed around $ND{\sim}21.8{\mu}g/kg$, which is not regulated presently in Korea. The 56 samples presented levels below the limits of detection and quantitation.

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.

Analyzing the User Intention of Booth Recommender System in Smart Exhibition Environment (스마트 전시환경에서 부스 추천시스템의 사용자 의도에 관한 조사연구)

  • Choi, Jae Ho;Xiang, Jun-Yong;Moon, Hyun Sil;Choi, Il Young;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.3
    • /
    • pp.153-169
    • /
    • 2012
  • Exhibitions have played a key role of effective marketing activity which directly informs services and products to current and potential customers. Through participating in exhibitions, exhibitors have got the opportunity to make face-to-face contact so that they can secure the market share and improve their corporate images. According to this economic importance of exhibitions, show organizers try to adopt a new IT technology for improving their performance, and researchers have also studied services which can improve the satisfaction of visitors through analyzing visit patterns of visitors. Especially, as smart technologies make them monitor activities of visitors in real-time, they have considered booth recommender systems which infer preference of visitors and recommender proper service to them like on-line environment. However, while there are many studies which can improve their performance in the side of new technological development, they have not considered the choice factor of visitors for booth recommender systems. That is, studies for factors which can influence the development direction and effective diffusion of these systems are insufficient. Most of prior studies for the acceptance of new technologies and the continuous intention of use have adopted Technology Acceptance Model (TAM) and Extended Technology Acceptance Model (ETAM). Booth recommender systems may not be new technology because they are similar with commercial recommender systems such as book recommender systems, in the smart exhibition environment, they can be considered new technology. However, for considering the smart exhibition environment beyond TAM, measurements for the intention of reuse should focus on how booth recommender systems can provide correct information to visitors. In this study, through literature reviews, we draw factors which can influence the satisfaction and reuse intention of visitors for booth recommender systems, and design a model to forecast adaptation of visitors for booth recommendation in the exhibition environment. For these purposes, we conduct a survey for visitors who attended DMC Culture Open in November 2011 and experienced booth recommender systems using own smart phone, and examine hypothesis by regression analysis. As a result, factors which can influence the satisfaction of visitors for booth recommender systems are the effectiveness, perceived ease of use, argument quality, serendipity, and so on. Moreover, the satisfaction for booth recommender systems has a positive relationship with the development of reuse intention. For these results, we have some insights for booth recommender systems in the smart exhibition environment. First, this study gives shape to important factors which are considered when they establish strategies which induce visitors to consistently use booth recommender systems. Recently, although show organizers try to improve their performances using new IT technologies, their visitors have not felt the satisfaction from these efforts. At this point, this study can help them to provide services which can improve the satisfaction of visitors and make them last relationship with visitors. On the other hands, this study suggests that they managers along the using time of booth recommender systems. For example, in the early stage of the adoption, they should focus on the argument quality, perceived ease of use, and serendipity, so that improve the acceptance of booth recommender systems. After these stages, they should bridge the differences between expectation and perception for booth recommender systems, and lead continuous uses of visitors. However, this study has some limitations. We only use four factors which can influence the satisfaction of visitors. Therefore, we should development our model to consider important additional factors. And the exhibition in our experiments has small number of booths so that visitors may not need to booth recommender systems. In the future study, we will conduct experiments in the exhibition environment which has a larger scale.