• Title/Summary/Keyword: moment capacity

Search Result 937, Processing Time 0.026 seconds

Determination of Resistance Factors for Drilled Shaft Based on Load Test (현장타설말뚝의 주면지지력 저항계수 산정)

  • Kim, Seok-Jung;Jung, Sung-Jun;Kwon, Oh-Sung;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.427-434
    • /
    • 2010
  • Load Resistance Factor Design method is used increasingly in geotechnical design world widely and resistance factors for drilled shafts are suggested by AASHTO. However, these resistance factors are determined for intact rock conditions, by comparison most of bedrocks in Korea are weathered condition, so that applying the AASHTO resistance factors is not reasonable. Thus, this study suggests the proper resistance factors for design of drilled shaft in Korea. The 22 cases of pile load test data from 8 sites were chosen and reliability-based approach is used to analyze the data. Reliability analysis was performed by First Order Second Moment Method (FOSM) applying 4 bearing capacity equations. As a result, when the Factor of Safety(FOS) were selected as 3.0, the target reliability index($\beta_c$) were evaluated about 2.01~2.30. Resistance factors and load factors are determined from optimization based on above results. The resistance factors ranged between 0.48 and 0.56 and load factor for dead load and live load are evaluated approximately 1.25 and 1.75 respectively. However, when the target reliability are considered as 3.0, the resistance factors are evaluated as approximately 50% of results when the target reliability index were 2.0.

  • PDF

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECT OF CORTICAL ENGAGEMENT ON IMPLANT LOAD TRANSFER IN POSTERIOR MANDIBLE (하악구치부 피질골 engagement가 임플란트 하중전달에 미치는 영향에 관한 3차원 유한요소법적 응력분석)

  • Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.607-619
    • /
    • 1999
  • Cortical support is an important factor, as the engagement of the fixture in strong compact bone offers an increased load-carrying capacity and initial stability. Because of the poor bone quality in the posterior mandible and other anatomic considerations, it has been suggested that implant fixtures be placed in these locations with apical engagement of the lingual cortical plate for so-called bicortication. The purpose of this investigation was to determine the effect of cortical engagements and in addition polyoxymethylene(POM) intramobile connector(IMC) of IMZ implant on implant load transfer in edentulous posterior segment of mandible, using three-dimensional (3D) finite element analysis models composed of cortical and trabecular bone involving single implant. Variables such as (1) the crestal peri-implant defect, (2) the apical engagement of lingual cortical plate, (3) the occlusal contact position (a vertical load at central fossa or buccal cusp tip), and (4) POM IMC were investigated. Stress patterns were compared and interfacial stresses along the bone-implant interface were monitored specially. Within the scope of this study, the following observations were made. 1) Offset load and angulation of fixture led to increase the local interfacial stresses. 2) Stresses were concentrated toward the cortical bones, but the crestal peri-implant defect increased the interfacial stresses in trabecular bone. 3) For the model with bicortication, it was noticed that the crestal cortical bone provided more resistance to the bending moment and the lingual cortical plate provided more support for the vertical load. But Angulation problem of the fixture from the lingual cortical engagement caused the local interfacial stress concentrations. 4) It was not clear that POM IMC had the effect on stress distribution under the present experimental conditions, especially for the cases of crestal peri-implant defect.

  • PDF

Lattice Shear Reinforcement for Slab-Column Connection Subjected to Unbalanced Moment (불균형모멘트를 받는 슬래브-기둥 접합부를 위한 래티스 전단 보강)

  • Park, Hong-Gun;Kim, You-Ni;Song, Jin-Kyu;Kim, Sun-Kyu;Lee, Chul-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.301-312
    • /
    • 2007
  • A slab-column connection is susceptible to brittle punching shear failure, which may result in the necessity of shear reinforcement. In the present study, to investigate the earthquake resistance of newly developed lattice shear reinforcement, experimental study was performed for interior slab-column connections subjected to cyclic loading. For comparison, specimens with existing shear reinforcement method such as stud rail, shear band and stirrup were also tested. The test result showed that the structural capacity of the lattice shear reinforcement was superior to those of the existing methods and was greater than the code-specified strength. On the other hand, the existing methods did not significantly improve the shear strength of the specimens. The shear strengths of the existing methods were much less than the code-specified shear strength.

Numerical experimentation for the optimal design for reinforced concrete rectangular combined footings

  • Velazquez-Santilla, Francisco;Luevanos-Rojas, Arnulfo;Lopez-Chavarria, Sandra;Medina-Elizondo, Manuel;Sandoval-Rivas, Ricardo
    • Advances in Computational Design
    • /
    • v.3 no.1
    • /
    • pp.49-69
    • /
    • 2018
  • This paper shows an optimal design for reinforced concrete rectangular combined footings based on a criterion of minimum cost. The classical design method for reinforced concrete rectangular combined footings is: First, a dimension is proposed that should comply with the allowable stresses (Minimum stress should be equal or greater than zero, and maximum stress must be equal or less than the allowable capacity withstand by the soil); subsequently, the effective depth is obtained due to the maximum moment and this effective depth is checked against the bending shear and the punching shear until, it complies with these conditions, and then the steel reinforcement is obtained, but this is not guaranteed that obtained cost is a minimum cost. A numerical experimentation shows the model capability to estimate the minimum cost design of the materials used for a rectangular combined footing that supports two columns under an axial load and moments in two directions at each column in accordance to the building code requirements for structural concrete and commentary (ACI 318S-14). Numerical experimentation is developed by modifying the values of the rectangular combined footing to from "d" (Effective depth), "b" (Short dimension), "a" (Greater dimension), "${\rho}_{P1}$" (Ratio of reinforcement steel under column 1), "${\rho}_{P2}$" (Ratio of reinforcement steel under column 2), "${\rho}_{yLB}$" (Ratio of longitudinal reinforcement steel in the bottom), "${\rho}_{yLT}$" (Ratio of longitudinal reinforcement steel at the top). Results show that the optimal design is more economical and more precise with respect to the classical design. Therefore, the optimal design presented in this paper should be used to obtain the minimum cost design for reinforced concrete rectangular combined footings.

Influence of the stiffness of Vertical Joints on the Behaviour of Precast Shear Walls. Part1. Load Case 1 (연직접합(鉛直接合)의 강성(剛性)이 프리케스트 전단벽(剪斷壁)의 구조적거동(構造的擧動)에 미치는 영향(影響) I. 하중조합(荷重組合) 1에 대하여)

  • Park, Kyung-Ho
    • Journal of Industrial Technology
    • /
    • v.3
    • /
    • pp.103-116
    • /
    • 1983
  • Recent developments in multi-storey buildings for residential purpose have led to the extensive use of shear walls for the basic structural system. When the coupled shear wall system is used, joined together with cast-in-place concrete or mortar (or grout), the function of the continuous joints is a crucial factor in determining the safety of L.P. Precast concrete shear wall structures, because the function of the continuous joints(Vertical wall to wall joints) is to transfer froces from one element(shear wall panel) to another, and if sufficient strength and ductility is not developed in the continuous joints, the available strength in the adjoining elements may not be fully utilized. In this paper, the influence of the stiffness of vertical joints(wet vertical keyed shear joints) on the behaviour of precast shear walls is theoretically investigated. To define how the stiffness of the vertical joints affect the load carrying capacity of L.P.Precast concrete shear wall structure, the L.P.Precast concrete shear wall structure is analyzed, with the stiffness of the vertical joints varying from $K=0.07kg/mm^3$(50MN/m/m) to $K=1.43kg/mm^3$(1000MN/m/m), by using the continuous connection method. The results of the analysis shows that at the low values of the vertical stiffness, i.e. from $K=0.07kg/mm^3$(50MN/m/m) to $K=0.57kg/mm^3$(400MN/m/m), the resisting bending moment and shearing force of precast shear walls, the resisting shearing force of vertical joints and connecting beams are significantly affected. The detailed results of analysis are represented in the following figures and Tables.

  • PDF

Experiment on Flexural Analysis of RC Beams Strengthened with Composite Material Panel (복합재료 패널로 보강된 철근 콘크리트 보의 휨 실험)

  • Kim, Jin-Man;Jung, Mi-Roo;Lee, Jae-Hong;Yoon, Kwang-Sup
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.117-126
    • /
    • 2010
  • Experiment on flexural analysis of RC beams strengthened with composite material panel is presented. Recently, the strengthening of reinforced concrete structures using advanced fiber reinforced plastic (FRP) composites, and in particular the behavior of FRP-reinforced concrete structure is topic that has become very popular because of good corrosion resistance and easy for site handling due to their light weight. In this study, an efficient computational analysis using ABAQUS to predict the ultimate moment capacity of reinforced concrete beams strengthened with FRP is presented. Test parameters in this study are the shape of fiber arrangement (LT, DB, DBT) and the number of carbon fiber sheets (2ply, 3ply). When comparing with results of the analytical model, results of the experiments show similar values. Furthermore, reinforced concrete beam with FRP obtains improved effects for ultimate strength.

  • PDF

Generalized Analysis of RC and PT Flat Plates Using Limit State Model (한계상태모델을 이용한 철근콘크리트와 포스트텐션 무량판의 통합해석)

  • Kang, Thomas H.K.;Rha, Chang-Soon
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.599-609
    • /
    • 2009
  • This paper discusses generalized modeling schemes for both reinforced concrete (RC) and post-tensioned (PT) flat plate buildings. In this modeling approach, nonlinear behavior due to slab flexure, moment and shear transfer at slab-column connections, and punching shear was included along with linear secant stiffness of each member or connection that accounts for concrete cracking. This generalized model was capable of simulating all different scenarios of slab-column connection failures such as brittle punching, flexure-shear interactive failure, and flexural failure followed by drift-induced punching. Furthermore, automatic detection of drift-induced punching shear and subsequent backbone curve modifications were realistically modelled by incorporating the limit state model, in which gravity shear versus drift capacity relations were adopted. The validation of the model was conducted using one-third scale two-story by two-bay RC and PT flat plate frames. The comparisons revealed that the model was robust and effective.

A Study on Deformation Capacity of High Strength Steel Beam-to-Column Connections According to Welding Detail at Beam End (보 단부 용접상세에 따른 고강도강 기둥-보 접합부의 변형능력에 관한 연구)

  • Oh, Sang Hoon;Park, Hae Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.335-348
    • /
    • 2014
  • For high-strength steel, it is difficult to be applied to flexible structural member because it have high yield ratio and low basic material's toughness. One of the great problems when using high-strength steel connections is the brittle fracture at the end of the beam member in common with general mild steel connections. In the cases of mild steel connections, it has be developed that special moment frame connection details by reinforcing structural member or improvement of welding access hole. But, it is incomplete at yet about applicability estimation of high-strength steel connections. This study is the initial step research for the applicability estimation of beam-to-column connections being applied to developed high-strength steel, HSA800. And, it studied about structural performance of the high-strength steel connections according to the details of welding access hole through full-scale test and analytical method.

Evaluation of Seismic Strengthening Approach at the Boundary Elements of RC Walls using Prestressed Wire Rope Units (프리스트레스트 와이어로프를 사용한 RC 벽체의 단부 경계요소 내진보강 평가)

  • Kwon, Hyuck-Jin;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.56-63
    • /
    • 2018
  • The present study examined the reversal cyclic flexural behavior of walls with jacket section approach for seismic strengthening through forming the boundary elements at both ends of the wall. The prestressed wire ropes were used for the lateral reinforcement to confine the boundary element of the wall. The main parameter investigated was the height of the jacket section for strengthening. The limit height of the strengthening jacket section was determined by comparing the moment distributions between the existing and strengthened walls. Test results showed that the examined jacket section approach was significantly effective in enhancing the flexural resistance of walls, indicating 46% higher stiffness at peak strength and 210% greater work damage indicator, compared with the flexural performance of the unstrengthened wall. The ductility of the strengthened walls was insignificantly affected by the height of the jacket section when the height is greater than twice the wall length. The flexural capacity of the strengthened walls was 22% higher than the predictions obtained using the equivalent stress block specified in ACI 318-14.

A Study on the Korea Database Industry Promotion Act Legislation

  • Bae, Seoung-Hun;Lim, Jung-Sun;Lee, Jae-Jin;Park, Cheon-Woong;Shin, Kwang-Min;Kang, Sang-Kyu;Yoon, Jin-Sun;Shin, Minsoo
    • Journal of Information Science Theory and Practice
    • /
    • v.1 no.3
    • /
    • pp.60-73
    • /
    • 2013
  • The Database Industry Promotion Act was proposed at the National Assembly plenary session on July 26, 2012 and since then it has been in the process of enactment in consultation with all the governmental departments concerned. The recent trend of economic globalization and smart device innovation suggests a new opportunity and challenges for all industries. The database industry is also facing a new phase in an era of smart innovation. Korea is in a moment of opportunity to take an innovative approach to promoting the database industry. Korea should set up a national policy to promote the database industry for citizens, government, and research institutions, as well as enterprises. Above all, the Database Industry Promotion Act could play a great role in promoting the social infrastructure to enhance the capacity of small and medium-sized enterprises. This article discusses the background of the development of the Database Industry Promotion Act and its legislative processes in order to clarify its legal characteristics, including the meaning of the act. In addition, this article explains individual items related to the overall structure of the Database Industry Promotion Act. Finally, this article reviews the economic effects of the database industry for now and the future.