• 제목/요약/키워드: molar tooth

검색결과 805건 처리시간 0.033초

골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석 (PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT)

  • 김영일;정재헌;조규종
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

골 유착성 임프란트 보철수복시 자연지대치와의 고정유무에 따른 유한요소법적 응력분석 (FINITE ELEMENT ANALYSIS OF STRESSES INDUCED BY OSSEOINTEGRATED PROSTHESES WITH OR WITHOUT CONNECT10N BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED ABUTMENTS)

  • 고헌주;정재헌
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.147-160
    • /
    • 1991
  • The purpose of this study was to examine, by the method of finite element analysis, how implant geometry with or without connection between natural tooth and osseointegrated abutments affected the stress distribution in surrounding bone and osseointegrated prosthesis. The mandibular first and second molars were removed and the two osseointegrated implants were placed in the first and second molar sites. Stress analysis induced by prostheses with connection(Model A)or without connection(Model B) between natural tooth(second bicuspid) and two osseointegrated abutments(first molar and second molar) was performed under vertical point load(Load P1) or distributed point load(Load P2). The results were as follows; 1. Under vertical point load, mesial tilting was shown in both Model A and Model B and inferior displacement of Model A was greater than that of Model B in the second bicuspid. 2. Under vortical point load, the first and second molars showed mesial tilting in both Model A and Model B, and inferior displacement of them was similar in Model A and Model B and was less than that of the second bicuspid. 3. Under distributed point load, mesial displacement was shown in Model A and Model B and inferior displacement of Model A was less than that of Model B in the second bicuspid. 4. Under distributed point load, mesial tilting was shown and inferior displacement of Model A was similar to that of Model B in the first and second molars. 5. In Model A under vertical point load, high stress was concentrated in the corneal portion of first molar and distributed throughout the second molar and the second bicuspid, and the stress distribution of the second molar was greater than that of the second bicuspid. 6. In Model B under vertical point load, high stress was concentrated in the coronal and mesio-cervical portion of the first molar. 7. In Model A under distributed point load, high stress was concentrated in the mesio-cervical portion of the first molar and evenly distributed throughout the second molar and the second bicuspid. 8. In Model B under distributed point load, high stress was concentrated in the disto-cervical portion of the second bicuspid and evenly distributed throughout the first and second molars.

  • PDF

하악각 골절에서 제 3 대구치 발치 후 아테로-콜라겐 스펀지의 유용성 (Usefulness of Atelo-collgen sponge (Teruplug$^{(R)}$) for Treatment of Mandibular Angle Fractures with Third Molar Extraction)

  • 오화영;최환준;권준성;이형교;김용배
    • Archives of Plastic Surgery
    • /
    • 제38권2호
    • /
    • pp.155-160
    • /
    • 2011
  • Purpose: Fibrillar collagens like type I collagen, are the major constituent of the extracellular matrix and structural protein of bone. Also, it can be a scaffold for osteoblast migration. The purpose of this study is to estimate the effects of absorbable atelo-collagen sponge (Teruplug$^{(R)}$, Terumo biomaterials Co., Tokyo, Japan) insertion in tooth extraction sites on periodontal healing of the second molar, healing of the fractured mandibular bone and new bone formation of third molar socket after the extraction of the impacted third molar with mandibular angle fracture. Methods: In our study of six cases of mandibular angle fractures, all of them underwent the extraction of the third molar tooth & absorbable atelo-collagen sponge insertion in tooth extraction site. Three of them had a intraoral infection & oral opening to fracture site, two of the six had dental caries, and only one had reduction problem due to third molar position. Six consecutive patients with noncomminuted fractures of the mandibular angle were treated by open reduction and internal fixation using one noncompression miniplates and screws placed through a transoral incision. Results: All of the patients have showed good postoperative functions and have not experienced complications requiring second surgical intervention. There was well healing of the mandibular bone and the most new bone formation of third molar socket after the extraction of the impacted third molar with mandibular angle fracture. Conclusion: The results of this study suggest that absorbable atelo-collagen sponge is relatively favorable bone void filler with prevention of tissue collapse, food packing, and enhance periodontal healing. Thus, the use of atelo-collagen sponge and one noncompression miniplate seems to be relatively easy, safe, and effective for the treatment of fractures of the mandibular angle and third molar extraction.

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.452-456
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS. Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (${\alpha}$=.05). RESULTS. The discrepancy between the impressions for the canine, premolar, and molar teeth were $6.3{\mu}m$ (95% confidence interval [CI], 5.4-7.2), $6.4{\mu}m$ (95% CI, 5.3-7.6), and $8.9{\mu}m$ (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: $26.7{\mu}m$ (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, $16.3{\mu}m$ (95% CI, 15.3- 17.3), and $14.0{\mu}m$ (95% CI, 12.3-15.7), respectively. CONCLUSION. The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between $6.3{\mu}m$ and $8.9{\mu}m$, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions.

하악 제3대구치가 하악 우각부골절 정복술후 감염에 미치는 영향에 관한 연구 (EFFECT OF THIRD MOLAR ON POSTOPERATIVE INFECTION AFTER REDUCTION OF THE MANDIBULAR ANGLE FRACTURE)

  • 최문기;민승기;이동근;오승환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권3호
    • /
    • pp.217-225
    • /
    • 2001
  • Any fracture passing through the socket of a teeth is compounded intraorally, even if the fracture is not displaced and the tooth is firm in its socket. Before the advent of antibiotic therapy the danger of infection in a compounded fracture posed severe problems in treatment. Infection is reduced by antibiotic therapy but prolonged use of antibiotics is not justified in an attempt to save a tooth which might eventually be sacrificed. There is still controversy in the management of third molar in mandibualr angle fracture, particulary in regard to their retention or removal at the time of fracture treatment. So we surveyed the 159 patients who were treated with open reduction of mandibular angle fracture containing third molar in fracture line, and compared with the postoperative infection rate depending on time intervals between injury and operation, eruption state of third molar, non-extraction or extraction of third molar related to eruption state, non-extraction or extraction of third molar related to condiition of third molar and its surrounding periodontium and were to propose treatment guidline of third molar in mandibular angle fracture The results obtained were as follows : 1. There were no statistical significance between the time from injury to operation and postoperative infection. 2. There were no statistical significance between eruption state of third molar and postoperative infection. 3. In case of retention of the third molar, there were no statistical significance between eruption state of third molar and postoperative infection, but in case of extraction, postoperative infection was high rate in complete impacted cases. 4. There were no statistical significance between non-extraction or extraction of third molar and postoperative infection depending on condition of third molar. There are no difference in infection rate statistically according to the time from injury to operation, eruption state and condition of third molar, but retention of third molar revealed lowered infection rate in completely impacted cases. By terms of the manegement of third molar, we should extract or preserve third molar in the line of the mandibular angle fracture according to possibility of infection.

  • PDF

하악(下顎) 제2대구치(第二大臼齒)의 맹출과정(萌出過程)에 관(關)한 연구(硏究) (THE STUDY OF THE ERUPTION PATTERN OF THE MANDIBULAR SECOND PERMANENT MOLAR)

  • 김무
    • 대한소아치과학회지
    • /
    • 제6권1호
    • /
    • pp.53-63
    • /
    • 1979
  • To Study the eruption pattern of the mandibular second permanent molar, the author took 425 cases of Oblique Cephalogram from 6 to 13 years old children and observed the vertical and mesiodistal directional change and tooth axis change. The following results were obtained. : 1. The eruption pattern of the mandibular second permanent molar was changed at about 10.0~10.1 ages or calcification stage IX. 2. At the early stage, the path of eruption of the mandibular second parmanent molar directed upward and forward and after calcification stage IX it changed to the direction of upward. 3. At the early stage, the distance from the distal end of the mandibular first permanent molar to the anterior portion of the ascending ramus was 0.9~1.0 times larger than the mesio-distal diameter of the mandibular second molar, but at the later stage it was increased 1.4 times larger than the mesio-distal diameter of the mandibular second permanent molar.

  • PDF

변형 Widman 판막술 후 치아 동요도 변화에 관한 연구 (Comparative Study on the Tooth Mobility after Modified Widman Flap)

  • 김수용;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제33권1호
    • /
    • pp.103-111
    • /
    • 2003
  • Tooth mobility is an important part of a periodontal examination and represents a function of the persisting height of the alveolar bone and the width of the periodontal ligament. The purpose of this study was to evaluate the changes of the tooth mobility over 4 week-period following surgical therapy on the periodontal disease. Thirty five patients presenting with moderate periodontal pockets were selected and tooth mobility was measured at weekly intervals using Periotest (Siemens Co., Germany) beginning at the pre-operation examination and ending four weeks following the modified Widman Flap. All data were statistically analyzed using the one-way ANOVA test. The results were obtained as follows; 1. All teeth exhibited the greatest change in mobility at 1 week post-op, mobility generally decreasing with time. 2. Comparison of the weekly tooth mobility data regarding the 1st premolars showed significant differences only between weeks 1 (9.94) and 4 (6.14) (p<0.05). 3. Comparison of the weekly tooth mobility data regarding the 1st molar showed significant changes in the intervals between pre-op (6.49) and week 1 (11.22), pre-op and week 2 (9.37), weeks 1 and 3 (7.65), weeks 1 and 4 (5.62), and weeks 2 and 4 (p<0.05). 4. Comparison of the weekly tooth mobility data regarding the 2nd premolar and 2nd molar showed significant differences between pre-op (6.91, 8.60) and week 1 (11.02, 12.62), weeks 1 and 3 (8.00, 8.05), weeks 3 ad 4 (6.22, 6.71), and weeks 2 (9.34, 11.01) and 4 (p<0.05).

콘빔 CT를 이용한 하악 제3대구치부의 부하악관 평가 (Assessment of accessory mandibular canal in mandibular third molars using cone-beam computed tomography)

  • 조봉혜;정연화
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.753-761
    • /
    • 2014
  • Purpose: This study was performed to examine distribution of accessory mandibular canal and its characteristics in mandibular third molars. Materials and methods: A total of 251 subjects (166 males and 85 females) having mandibular third molars bilaterally were included in the study. Cone-beam computed tomographic images were reviewed for bifid or trifid accessory mandibular canal. The prevalence of accessory mandibular canal was evaluated according to gender, side and its branching type. Proximity and crosssectional position of accessory mandibular canal to mandibular third molar was analyzed. Results: Accessory mandibular canals were found in 66 (26.3%) of 251 patients and 86 (17.1%) of 502 hemi-mandibles. Gender and sides showed no statistically significant differences in prevalence. Retromolar canal (46.1%) was the most common branching type. Proximity of accessory canal to mandibular third molars showed mean distance of 2.8 mm from third molar and a statistically significant difference was found among types of accessory canal. Dental canal was the closest to tooth among branching types and closer to tooth than main canal. On cross-sectional view, accessory canal was generally located on buccal side of mandibular third molar. Conclusion: Accessory mandibular canal was common and well detected with cone-beam computed tomography. Their localization is significant in all anesthetic and surgical procedures involving mandibular third molars.

Peripheral Neuropathy in the Orofacial Region after Third Molar Extraction as an Initial Manifestation of Anemia: Two Case Reports

  • Kim, Hye-Kyoung;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • 제44권1호
    • /
    • pp.40-44
    • /
    • 2019
  • Third molar extraction, one of the important surgical treatments commonly practiced in dentistry, presents various symptoms after surgery ranging from temporary or mild symptoms to permanent or severe complications. However, oral burning pain, dysesthesia, parageusia, dry mouth, headache and pain in multiple teeth are not the common symptoms that patients often complain after dental extraction. Here, the authors report two cases who presented acute neuropathic symptoms mentioned above in the orofacial regions following third molar extraction. At the initial examination, the healing of the tooth sockets of two patients was normal. One patient was diagnosed as megaloblastic anemia associated with Vitamin $B_{12}$ deficiency and was referred to the Department of Hematology for assessing the underlying etiology of anemia. The laboratory test for the other patient revealed microcytic anemia related to iron deficiency. The patient with iron deficiency anemia was successfully treated with iron supplement. These two cases suggest that anemia, as an underlying systemic disease, may be a rare etiology explaining acute onset of peripheral neuropathy in the orofacial regions after third molar extraction and should be considered in the assessment of patients who report neuropathic symptoms after dental extraction.