• 제목/요약/키워드: moisture conditioning

검색결과 105건 처리시간 0.032초

열.수분 동시이동 모델을 이용한 지하구조물 및 주변지반의 열수분성상 예측에 관한 연구 (Computational Analysis of the Heat/Moisture Characteristics and Heat Load of Underground Structures)

  • 박경순;손원득
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.901-905
    • /
    • 2008
  • This study was conducted to clarify the heat load characteristics and heat and moisture behavior of underground structures. The authors achieved this by carrying out a numerical analysis using simple heat diffusion and simultaneous heat and moisture transfer equations based on measurement data. This paper presents the results of a numerical analysis on the heat load characteristics and heat and moisture behavior of an underground basement and its surrounding ground under a condition of internal heat generation. The authors found it difficult to predict the heat behavior and heat load of the underground basement by simple heat diffusion alone. Accurate prediction of the thermal environment and heat load requires careful consideration of the influences of moisture and precipitation

  • PDF

건축자재 내의 수분이 곰팡이 성장에 미치는 영향 (Influence of Moisture on Mold Growth in Building Materials)

  • 서장후
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.852-857
    • /
    • 2012
  • Recently, the indoor air pollution by microbes such as fungi and mites have become a concern as important research topic on indoor air quality. Fungal growth is significantly affected by humidity. In this study, we examined the influence of relative humidity on the surface of building materials and the water content of building materials on the fungal growth rate by measuring the mycelium length of fungi in the fungal detector placed on the surface of building materials. As a result, even if the relative humidity on the surface of building materials is identical, the more water content of building materials is, the more fungi grow faster. It was suggested that fungal growth rate depends on not only the relative humidity on the surface of building materials but also the water content of building materials.

혼합과 건조가 가능한 건조기 개발에 관한 연구 (Development of the Dryer Designed for Mixture and Drying)

  • 금성민
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.327-333
    • /
    • 2008
  • The purpose of this study is to develop a paddle-type dryer and to commercialize the dryer, in which mixing and drying can be done simultaneously. According to a performance test, a newly-designed paddle-type dryer can dry Chitosan salt to a low moisture contents below 0.3%. Also the newly-designed dryer can dry air pollution materials, because the dryer can operate in a closed system. The economic efficiency of a newly-designed system and an existing system was compared in a performance test. As a result, the economic efficiency of a newly-designed system was higher than an existing system. In conclusion, it is thought that the newly-designed system has a high commercial value.

태양열 온풍 이용을 위한 재생기의 설계 최적화 모델에 관한 연구 (Response Surface Approach to Design Optimization of Regenerator Using Hot Air Heated by Solar Collector)

  • 우종수;최광환;윤정인
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.7-14
    • /
    • 2003
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an energy efficient regenerator, this study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called response surface methodology(RSM), which may provide a functional relationship between independent and dependent variables. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

MILLING CHARACTERISTICS OF BROWN RICE USING A CONTINUOUS TYPE CONDITIONER

  • Song, D.B.;Han, K.Y.;Kim, S.T.;Choi, B.J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.423-429
    • /
    • 2000
  • The water conditioning experiments of brown rice were performed to verify the effect of brown rice conditioner and to decide the optimum operating variables for the conditioner. The initial moisture contents of 13-14%(wb) brown rice were used as experimental samples. The flow rate of brown rice passing through the conditioner was 2,940 kg/hr and water was supplied proportionally from 80 cc/min to 240 cc/min. The differences between expected and measured moisture contents were neglected except 0.25%(wb) of the maximum differences at 0.2920((cc/min)-water/(kg/min)'%-brown rice) of water supply rate. For the initial moisture contents of 13-14%(wb) brown rice, it was found that a proper water supply rate was 0.2415((cc/min)-water/(kg/min).%-brown rice) and the increments of whole rice was 2.3% compared to non conditioned ones. It was considered that the conditioning process did not influence the whiteness of milled rice because the whiteness differences between conditioned and non-conditioned milled rice were negligible.

  • PDF

온·습도 조건이 전자 복사용지의 물리적 특성에 미치는 영향 (Effects of Temperature and Relative Humidity on the Physical Properties of Electronic Copying Paper)

  • 강광호;김형진
    • 펄프종이기술
    • /
    • 제44권3호
    • /
    • pp.70-78
    • /
    • 2012
  • For evaluating the printing suitability of electronic copying papers in the aspect of climate conditions, 12 samples of copying papers being generally used in Korea and worldwide were collected. The copying papers were controlled by various temperature and humidity options in conditioning equipment in order to simulate the specific circumstances of dry, temperate or tropical climate, and the pre-heating system of photocopying machines during printing. As results, some copying papers showed several physical problems, especially in recycled copying papers and a normal paper with original printing faulty. These problems of copying papers were mostly resulted in extremely high moisture circumstance, and in lower levels of tensile strength and tensile stiffness. The moisture contents of copying papers during passing through the pre-heater system of photocopying machine could be rapidly decreased because paper is exposed to high temperature around the pre-heating zone. The copying paper, for example of XR3 sample, containing low moisture contents below 2% had high exfoliating possibility of toner transfer from copying paper.

골심지의 흡습제 함침에 의한 종이 재질 판형 전열교환 소자의 성능 향상 (Performance Improvement of a Paper Enthalpy Exchange Element by Impregnation of the Spacer)

  • 김내현
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.142-147
    • /
    • 2017
  • Improvement of the enthalpy exchange element's energy efficiency is of current interest from anenergy-saving viewpoint. In this study, a LiCl-impregnated spacer was devised as a means to improve the performance of the enthalpy exchange element. Two samples were tested : one with and one without impregnated spacers of $338{\times}338{\times}380mm$ sizes with 2.0 mm channel spacing. The results showed that the temperature efficiencies of the two samples were approximately the same. The humidity efficiency, however, was strongly affected by the LiCl impregnation. The impregnated sample yielded a 9% higher humidity efficiency under cooling and the difference increased to 14% under aheating condition. It was anticipated that more moisture would beadsorbed on the LiCl-impregnated spacers, which was delivered to their roots and eventually to the air in neighboring channels. Separate moisture adsorption tests revealed that both the adsorption rate and the amount of the adsorbed moisture are higher for the LiCl-impregnated specimen.

동결층소멸을 이용한 동결건조 속도에 관한 연구 (A Study on the Freeze Drying Rate with Frozen Layer)

  • 홍성선;이희명;오창섭
    • 설비공학논문집
    • /
    • 제2권2호
    • /
    • pp.105-111
    • /
    • 1990
  • The drying rate in freeze drying was obtained by experiment of garlic moisture contents depending on the drying time. Freeze drying experiment of garlic juice was carried out in vaccum freeze drier of laboratory scale by backface heating, and a mathematical model is also used to simulate the process of simultaneous heat and mass transfer in freeze drying to compare with experimental data.

  • PDF

Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF