• Title/Summary/Keyword: modified technique

Search Result 2,204, Processing Time 0.023 seconds

Management of Tracheostomal Stenosis : Modified Fish-Mouth Technique (변형된 Fish-Mouth Technique을 이용한 새로운 기관공성형술식)

  • Baek, Seung-Jae;Lim, Jae-Yol;Hong, Hyun-Jun;Choi, Hong-Shik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.1
    • /
    • pp.27-29
    • /
    • 2010
  • Tracheostomal stenosis after total laryngectomy is brothersome problem to surgeon and patient. To prevent tracheostomal stenosis, tension around the tracheostoma must be released. Advancement flap, V-Y inset and Z-plasty were suggested as solution to tracheostomal stenosis. But such methods need elevation of superior flap and it is very difficult when the patients received radiotherapy and has high change of developing pharyngocutaneous fistula. We suggested new stomaplasty technique which named "Modified Fish-Mouth Technique" that does not need to elevate superior skin flap.

Coded Single Input Channel for Color Pattern Recognition in Joint Transform Correlator

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.335-339
    • /
    • 2011
  • Recently, we reported a single input channel joint transform correlator for the color pattern recognition which decomposes the input color image into three R, G, and B gray components and adds those components into a single gray image in the input plane. This technique has the merit of a single input channel instead of three input channels. However, we found this technique has some problems with discrimination impossibility in the case of a simple primary color pattern which results in the same gray level through the addition process. Thus, we propose a modified coding technique which selectively recombines the decomposed three R, G, and B gray components instead of the simple adding process. Simulated results show that the modified coding technique can accurately discriminate a variety of kinds of color images.

Modified SNR-Normalization Technique for Robust Speech Recognition

  • Jung, Hoi-In;Shim, Kab-Jong;Kim, Hyung-Soon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3E
    • /
    • pp.14-18
    • /
    • 1997
  • One fo the major problems in speech recognition is the mismatch between training and testing environments. Recently, SNR normalization technique, which normalizes the dynamic range of frequency channels in mel-scaled filterbank, was proposed[1]. While it showed improved robustness against additive noise, it requires a reliable speech detection mechanism and several adaptation parameters to be optimized. In this paper, we propose a modified SNR normalization technique. In this technique, we take simply the maximum of filterbank output and predetermined masking constant for each frequency band. According to the speaker-independent isolated word recognition in car noise environments, proposed modification yields better recognition performance that the original SNR normalization method, with rather reduced complexity.

  • PDF

The Inverse Design Technique of Axial Blade Using the Parallel Calculation (병렬 연산을 이용한 축류 블레이드의 역설계)

  • Cho, J. K.;Ahn, J. S.;Park, W. G.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.200-207
    • /
    • 1999
  • An efficient inverse design technique based on the MGM (Modified Garabedian-McFadden) method has been developed. The 2-D Navier-Stokes equations are solved for obtaining the surface pressure distributions and coupled with the MGM method to perform the inverse design. The solver is parallelized by using the domain decomposition method and the standard MPI library for communications between the processors. The MGM method is a residual-correction technique, in which the residuals are the difference between the desired and the computed pressure distribution. The developed code was applied to several airfoil shapes and the axial blade. It has been found that they are well converged to their target pressure distribution.

  • PDF

Numerical Simulation of Nearshore Tsunami Using a Digital Wave Tank Simulation Technique (디지털 수치수조 기법에 의한 연안 Tsunami의 수치 시뮬레이션)

  • Park, Jong-Chun;Chun, Ho-Hwan
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.231-239
    • /
    • 2003
  • A Digital Wave Tank simulation technique based on a finite-difference method and a modified marker-and-cell (MAC) algorithm is applied to investigate the characteristics of nonlinear Tsunami propagations and their interactions with a 2D sloping beach and Ohkushiri island, and to predict maximum wave run-up around the island. The Navier-Stokes (NS) and continuity equation are governed in the computational domain and the boundary values updated at each time step by a finite-difference time-marching scheme in the frame of rectangular coordinate system. The fully nonlinear kinematic free-surface condition is satisfied by the modified marker-density function technique. The Nearshore Tsunami is assumed to be a solitary wave and generated from the numerical wavemaker in the developed Digital Wave Tank. The simulation results are compared with the experiments and other numerical methods based on the shallow-water wave theory.

  • PDF

Mode Matching Technique in a Cylindrical Cavity with Center Wire

  • Han, Dae Hyun
    • Journal of Multimedia Information System
    • /
    • v.5 no.2
    • /
    • pp.143-146
    • /
    • 2018
  • The eigen value problem of a coaxial cavity and a modified pill box cavity is investigated using the mode matching technique. The coaxial cavity has a cylindrical cavity with beam ports and center conductor. The pill box cavity is the same as a coaxial cavity without center conductor. The electric field and magnetic field are formulated in propagation region and resonance region. The boundary and orthogonal conditions are applied to the electric and magnetic fields. We derived the eigen value equation by the proposed procedure in a coaxial cavity and a modified pill box cavity. The electromagnetic field of the real structure is disturbed by the coaxial wire. The effect of the coaxial wire in pill box cavity with beam ports increase the dominant resonant frequency. The coaxial line method of the coupling impedance is not adequate for a cylindrical cavity. The results of the mode matching technique and simulation agree well. The results confirm the proposed formulation is valid.

Voltammetric Behaviors of Chemically Modified Electrodes Based on Zirconium Phosphonate Film

  • 홍훈기
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.9
    • /
    • pp.886-891
    • /
    • 1995
  • Electroactive monolayers based on zirconium(Ⅳ) phosphonate film were prepared on gold and tin oxide electrodes by sequential layer-by-layer depostion technique. High transfer coefficient values and surface coverages of surface bound redox molecules were obtained from the electrochemical measurements of heterogeneous electron transfer rates for monolayer modified electrodes. 1,10-Decanediylbis(phosphonic acid) (DBPA) monolayer as insulating barrier was effective in blocking electron transfer. However, these film modified oxide electrode shows voltammetric behavior of diffusion/permeation process taking place at very small exposed area of modified electrode through channels due to structural defects within film when a very fast redox couple such as Ru(NH3)63+ is hired.

Simultaneous implant placement with sinus augmentation using a modified lateral approach in the pneumatized posterior maxilla: A Case Report (함기화된 상악 구치부에서 변형 측방 접근법을 이용한 상악동 거상술과 임플란트 동시식립에 대한 증례보고)

  • Sun, Yoo-Kyung;Cha, Jae-Kook;Lee, Jung-Seok;Jung, Ui-Won
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.142-150
    • /
    • 2018
  • In the posterior maxillary area, due to resorption of the ridge after extraction and pneumatization of the maxillary sinus, the height of the alveolar ridge may not be sufficient for placement of implants. To solve this problem, sinus augmentation using both crestal and lateral approaches have been widely used. Jung et al. (2010) introduced the modified lateral approach technique, which is a simplified technique that combines the advantages of crestal and lateral approaches. The purpose of this case report is to report two cases in the posterior maxilla in which simultaneous implant placement with maxillary sinus augmentation has been performed using the modified lateral approach technique. In two female patients, 67 and 74 years old, respectively, simultaneous implant placement was performed using the modified lateral approach technique on the left maxillary second premolar and the first molar. In both patients, the residual bone height on the distal side of the maxillary second premolar was measured to be approximately 5 mm, and the residual bone height of the first molar was measured to be 2-3 mm. After flap elevation, osteotomy of the lateral window was performed in the form of a mesiodistally extended slot above the sinus floor and the Schneiderian membrane was elevated. Sequenced drilling was performed while protecting the membrane with a periosteal elevator. Bone graft and implant placement was performed after preparation of the implant site. Sufficient primary stability was achieved for each implant and sinus membrane was not perforated. After four and five months respectively, implant second surgery was performed. Clinically, the implants were observed to be stable. Implants and surrounding peri-implant mucosa were well maintained after prosthodontic treatment. In conclusion, the modified lateral approach could be a predictable and efficient technique for implant placement in the atrophied posterior maxilla.

  • PDF

Numerical Experiments Using Modified POM WAD with Computing Time Saving Technique (계산시간절약기법이 적용된 수정 POM WAD의 수치실험)

  • Park, Il Heum;Choi, Heung Bae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.72-82
    • /
    • 2015
  • In order to effectively and economically apply the previous POM(Princeton Ocean Model) WAD(Wetting And Drying) to the coastal area, the POM WAD was modified such as the water elevation input of tidal harmonics in the open boundaries was included and a CTS(Computing Time Saving) technique was introduced to the model. The modified model was tested to the standing waves in the rectangular bay and the hydraulic experiments for the flow and heat diffusion in the 3D basin. The numerical results showed a good agreement with the analytical solutions of the standing waves and the observed values by the hydraulic experiments, respectively. And also when the modified model with the CTS technique was applied to Gwangyang Bay of Korea, the computing time was decreased by as much as 39.4%.

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.