• Title/Summary/Keyword: modeling guideline

Search Result 182, Processing Time 0.015 seconds

The Study of Radiation Exposed dose According to 131I Radiation Isotope Therapy (131I 방사성 동위원소 치료에 따른 피폭 선량 연구)

  • Chang, Boseok;Yu, Seung-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.653-659
    • /
    • 2019
  • The purpose of this study is to measure the (air dose rate of radiation dose) the discharged patient who was administrated high dose $^{131}I$ treatment, and to predict exposure radiation dose in public person. The dosimetric evaluation was performed according to the distance and angle using three copper rings in 30 patients who were treated with over 200mCi high dose Iodine therapy. The two observer were measured using a GM surverymeter with 8 point azimuth angle and three difference distance 50, 100, 150cm for precise radion dose measurement. We set up three predictive simulations to calculate the exposure dose based on this data. The most highest radiation dose rate was showed measuring angle $0^{\circ}$ at the height of 1m. The each distance average dose rate was used the azimuth angle average value of radiation dose rate. The maximum values of the external radiation dose rate depending on the distance were $214{\pm}16.5$, $59{\pm}9.1$ and $38{\pm}5.8{\mu}Sv/h$ at 50, 100, 150cm, respectively. If high dose Iodine treatment patient moves 5 hours using public transportation, an unspecified person in a side seat at 50cm is exposed 1.14 mSv radiation dose. A person who cares for 4days at a distance of 1 meter from a patient wearing a urine bag receives a maximum radiation dose of 6.5mSv. The maximum dose of radiation that a guardian can receive is 1.08mSv at a distance of 1.5m for 7days. The annual radiation dose limit is exceeded in a short time when applied the our developed radiation dose predictive modeling on the general public person who was around the patients with Iodine therapy. This study can be helpful in suggesting a reasonable guideline of the general public person protection system after discharge of high dose Iodine administered patients.

Establishment of the Room Acoustic Criteria for the Korean Traditional Music Halls Using Subjective Listening Tests (청감실험에 의한 국악당의 음향설계조건 설정)

  • Haan, Chan-Hoon;Shin, Jic-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.343-352
    • /
    • 2007
  • The present study aims to investigate the design standard for acoustic criteria of Korean traditional music which could be used for the design of Korean traditional music halls. In order to do this, subjective listening tests were undertaken to musicians using auralized sounds which were convolved with the impulse response of traditional instruments recorded in an anechoic chamber. 94 pairs of sound were made which have different value of acoustic parameters including RT, BR, Brilliance, G, C80, ITDG, IACC. A paired comparison method(PCM) was used to analyze the results from the subjective listening tests. The results show that the preference of acoustic criteria for the Korean traditional music is far different from those of western music. As a result, specific range of acoustic criteria were suggested for the appropriate acoustic conditions of Korean traditional music. Also, a guideline of the acoustic design of halls for performing the Korean traditional music was suggested which could be used as a basic reference in the future works.