• Title/Summary/Keyword: model concrete

Search Result 5,283, Processing Time 0.028 seconds

Failure mechanisms of hybrid FRP-concrete beams with external filament-wound wrapping

  • Chakrabortty, A.;Khennane, A.
    • Advances in concrete construction
    • /
    • v.2 no.1
    • /
    • pp.57-75
    • /
    • 2014
  • This paper presents an analysis of the results of an experimental program on the performance of a novel configuration of a hybrid FRP-concrete beam. The beam section consists of a GFRP pultruded profile, a CFRP laminate, and a concrete block all wrapped up using filament winding. It was found that the thickness of the concrete block and the confinement by the filament-wound wrapping had a profound effect on the energy dissipation behaviour of the beam. Using a shear punching model, and comparing the predicted results with the experimental ones, it was found that beyond a given value of the concrete block thickness, the deformational behaviour of the beam shifts from brittle to ductile. It was also found that the filament-wound wrap had many benefits such as providing a composite action between the concrete block and the GFRP box, improving the stiffness of the beam, and most importantly, enhancing the load carrying ability through induced confinement of the concrete.

An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

Nonlinear Model of FRP-Confined Concrete Members Considering with Three-Dimensional Behaviors (3차원 거동에 의한 원형 FRP-구속 콘크리트의 부재 비선형 모델)

  • Cho Chang-Geun;Kwon Minho;Park Moon-Ho;Kim Wha-Jung;Bae Soo-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.738-741
    • /
    • 2004
  • This study is concerning on modeling to predict the flexural behaviors of FRP-confined concrete structural members. For compressive behaviors of confined concrete by FRP jackets, the hypoelasticity-based constitutive law of concrete has been presented under the basis of three-dimensional stress states. The strength enhancement of concrete wrapped by FRP jackets has been determined by the failure surface of concrete in tri-axial states, and its corresponding peak strain is computed by the strain enhancement factor. The behavior of FRP jackets has been modeled using the mechanics of orthotropic laminated composite materials in two-dimensional stress states. To be based on the three-dimensional constitutive laws, an algorithm for the prediction of flexural bending behaviors of FRP-confined concrete structural member has been presented.

  • PDF

Nonlinear Finite Element Analysis of Composite Girder with Concrete Infilled Tube (콘크리트 충전 강관을 갖는 프리스트레스트 합성형 거더의 강-콘크리트 계면 거동)

  • Shin, Dong-Hun;Kim, Young-Hoon;Lee, Ta;Kang, Byeong-Su;Lee, Yong-Hak
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.386-389
    • /
    • 2006
  • Prestressed composite girder bridges with concrete infilled steel tube at negative flexural moment region takes the advantages of enhancing local buckling and flexural resistances resulting from the lateral confining effect of concrete due to the interactive reaction in the interface layer of steel tube and concrete. The interface behavior in concrete infilled tube of the test composite girder is analyzed by 8-node zero thickness interface finite element combined with 3-D. elastoplastic concrete constitutive model and 3-D. elastoplastic Mindlin shell element. The interface effects between infillled concrete and steel tube are investigated through the comparision of the experimental and numerical results.

  • PDF

The Analysis of Chloride Ion Penetration into a Concrete Structure in Marine Environment (해안환경하에 있는 콘크리트의 염분침투해석)

  • Cho, Sun-Kyu;Jeon, Gui;Shin, Chee-Burm
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.3 s.29
    • /
    • pp.68-74
    • /
    • 1998
  • An increase of concrete construction in marine environments as well as an increasing use of marine aggregate at the mixing stage of concrete has provoked an important problem. A high concentration of chloride ion in the vicinity of steel bars in concrete is the principal cause of premature reinforcement corrosion in concrete structures. In this study, the behavior of chloride ions introduced into concrete from concrete surface by marine evironment was analysed. A mathematical model including the diffusion of chloride ion in aqueous phase of pores, the adsorption and desorption of chloride ions to and from the surface of solid phase of concrete and the chemical reactions of chloride ions with solid phase was presented. Finite element method was employed to carry out numerical analysis. The results of this study may be used to predict the onset of reinforcement corrosion and to identify the maximum limit of chloride ions contained in concrete admixtures.

  • PDF

Confined Effect of Ultra High Strength Reinforced Concrete Tied Columns (초고강도 철근콘크리트 띠철근 기둥의 구속효과)

  • Han, Byum Seok;Shin, Sung Woo;Kim, Tae Soo
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.105-111
    • /
    • 2007
  • As this study investigates the influence about type of transverse reinforcement, spacing of transverse reinforcement(s), volumetric ratios of transverse reinforcement(${\rho}s$) of ultra-high strength concrete columns. It try to offer to resonable basic data of the confined model for the ultra-high concrete of in reinforced concrete columns. Experimental tests with large scaled columns were conducted under concentric axial loads. The ultra-high strength concrete (100MPa) was used. From this test result, it evaluate influence of the strength enhancement and ductility enhancement, important variables about behavior of the confined concrete by confinement of ultra-high strength reinforced concrete.There are two ways to improve the confinement effect of high strength concrete columns through the increase of amounts and/or strength of transverse reinforcement.

The Estimation on the Stirrup Effectiveness of Reinforced High Strength Concrete Beams (고강도 철근콘크리트 보에서 스터럽 유효성의 평가)

  • 김진근;박찬규;이영재;서원명
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.267-272
    • /
    • 1995
  • The objective of this study is to investigate the effect of concrete strength on the stirrup effectiveness factor(K) of reinforced concrete beams with stirrup based on previous test results(a/d$\geq$2.5). In the procedure of the estimation of K, it was assumed that the ultimate shear strength for beams without stirrup is equal to the concrete contribution to shear strength for beam with stirrup. A model equation for calculation the stirrup of compressive strength of concrete. It was shown that the stirrup effective factor of compressive strength of concrete. It wah shown that the stirrup effective factor is greater than 1.0 up to compressive strength 85MPa. Therefore the current ACI Code equation for predicting the shear strength and the stirrup effectiveness factor of 1.0 is conservative for nomal and high stength concrete beams with stirrup.

  • PDF

Constitutive Modeling of Confined High Strength Concrete (고강도 철근콘크리트 기둥의 구성모델)

  • Kyoung Oh, Van;Hyun Do, Yun;Soo Young, Chung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.445-450
    • /
    • 2003
  • The moment-curvature envelope describes the changes in the flexural capacity with deformation during a nonlinear analysis. Therefore, the moment-curvature analysis for reinforced concrete columns, indicating the available flexural strength and ductility, can be conducted providing the stress-strain relation for the concrete and steel are known. The moments and curvatures associated with increasing flexural deformations of the column may be computed for various column axial loads by incrementing the curvature and satisfying the requirements of strain compatibility and equilibrium of forces. Clearly it is important to have accurate information concerning the complete stress-strain curve of confined high-strength concrete in order to conduct reliable moment-curvature analysis to assess the ductility available from high-strength columns. However, it is not easy to explicitly characterize the mechanical behavior of confined high-strength concrete because of various parameter values, such as the confinement type of rectilinear ties, the compressive strength of concrete, the volumetric ratio and strength of rectangular ties, etc. So a stress-strain confinement model is developed which can simulate a complete inelastic moment-curvature relations of a high-strength reinforced concrete column

  • PDF

Derivation of Development Length in Pretensioned Prestressed Concrete Members (프리텐션공법의 프리스트레스트 콘크리트 부재의 정착길이 산정에 관한 실험 및 이론연구)

  • 오병환;김의성;최영철
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.3-11
    • /
    • 2000
  • In pretensioned concrete structures, bond between prestressing steel and concrete is an essential component to ensure the integrity of a pretensioned member. The anchorage and development of the prestressing force depend exclusively on bond. The purpose of this study is to investigate the characteristics of bond and development length between pretensioned steel and concrete. To resolve the controversy over the adequacy of the current code provision on development length of prestressing strands, a comprehensive test program has been scheduled and twenty four rectangular prestressed concrete beams have been tested to determine development length. Major test variables include diameter of strands (12.7mm, 15.2mm) and concrete covers (3cm, 4cm, 5cm). The test results indicate that the development length based on the bond stress-slip relation. The proposed model can evaluate realistically the development length of pretensioned prestressed concrete members and can be the good basis for the future basis of code equations on development length of PSC members.

Mechanical Properties of Concrete with Different Curing Temperature (양생온도변화에 따른 콘크리트의 재료역학적 특성)

  • 김진근;한상훈;양은익;조명석;우상균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.117-124
    • /
    • 1997
  • In this study, mechanical properties of type V cement concrete with different curing temperature were investigated. The tests for mechancial properties, i.e., compressive strength and modulus of elasticity, were carried out on two kinds of type V cement concrete mixes. concrete cylinders cured at 10, 23, 35 and 50℃ were tested at 1, 3, 7 and 8 days. The 'rate constant model' was used to described the combined effects of time and temperature on compressive strength development. Test results show that concrete subjected to high temperature at early age attains greater strength than concrete to low temperature but eventually attains lower later-age strength than that. With type V cement concrete, the linear and Arrhenius rate constant models both accurately describe the development of relative strength as afunction of the equivalent age.

  • PDF