• Title/Summary/Keyword: mode coupling

Search Result 781, Processing Time 0.027 seconds

Dynamic Characteristics and Stability Analysis of a Rotating Cantilever Pipe Conveying Fluid (유체유동 회전 외팔 파이프의 동특성 및 안정성 해석)

  • Kim, Dong-Jin;Yoon, Han-Ik;Son, In-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1185-1190
    • /
    • 2007
  • In this paper the vibration system is consisted of a rotating cantilever pipe conveying fluid. The equation of motion is derived by using the Lagrange's equation. Also, the equation of motion is derived applying a modeling method that employs hybrid deformation variables. Generally, the system of pipe conveying fluid becomes unstable by flutter. So, we studied about the influences of the rotating angular velocity, mass ratio and the velocity of fluid flow on the stability of a cantilever pipe by the numerical method. The influences of mass ratio, the velocity of fluid, the angular velocity of a cantilever pipe and the coupling of these factors on the stability of a cantilever pipe are analytically clarified. The critical fluid velocity$(u_{cr})$ is proportional to the angular velocity of the cantilever pipe. In this paper Flutter(instability) always occur in the second mode of the system.

  • PDF

Seismic design and elastic-plastic analysis of the hengda group super high-rise office buildings

  • Zhang, Xiaomeng;Ren, Qingying;Liu, Wenting;Yang, Songlin;Zhou, Yilun
    • Earthquakes and Structures
    • /
    • v.19 no.3
    • /
    • pp.175-188
    • /
    • 2020
  • The Hengda Group super high-rise building in Jinan City uses the frame-core tube structural system. With a height of 238.3 m, it is above the B-level height limit of 150 m for buildings within 7-magnitude seismic fortification zones. Therefore, it is necessary to apply performance-based seismic design to this super high-rise building. In this study, response spectrum analysis and comparative analysis of the structure are conducted using two software applications. Moreover, elastic time-history analysis, seismic analysis under an intermediate earthquake, and elastic-plastic time-history analysis under rare earthquakes are performed. Based on the analysis results, corresponding strengthening measures are implemented at weaker structural locations, such as corners, wall ends connected to framed girders, and coupling beams connected to framed girders. The failure mode and failure zone of major stress components of the structure under rare earthquakes are analysed. The conclusions to this research demonstrate that weaker locations and important parts of the structure satisfy the requirements for elastic-plastic deformation in the event of rare earthquakes.

An Improved Handoff Technique for a Seamless Multimedia Services (끊김 없는 멀티미디어 서비스를 위한 향상된 핸드오프 기법)

  • Kim Jeong-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.283-288
    • /
    • 2005
  • Packet transmission and independent addressing in the mobile environments are very similar to the ones in the multicasting environment. So, in this paper, we propose a new scheme about how to manage the multicasting group and to set the communication path in the mobile environment by applying two-level addressing mode, which is similar to mobile If, for location-independent address setting. And we propose the smooth handoff scheme that minimizes the handoff delay for mobile multimedia services. To check the performance of our proposed scheme, we modified the NS-2 network simulator and as a result, we showed that our proposed scheme is better than other techniques in terms of handoff delay and transmitted packets' throughput.

Resonant Properties of Modified $PvTiO_3$System Ceramics for High frequency Resonator (고주파 레조네이터용 변성 $PvTiO_3$계 세라믹스의 공진특성)

  • 민석규;류주현;박창엽;김종선;윤현상;정회승
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.976-980
    • /
    • 2001
  • In this study, P $b_{0.88}$(L $a_{a}$N $d_{l-a}$)$_{0.08}$(M $n_{1}$3/S $b_{2}$3/)$_{0.02}$ $Ti_{0.98}$ $O_3$system ceramics were manufactured for 20 MHz class resonator application. Electromechanical coupling factor, mechanical quality factor and dynamic range of 3rd overtone thickness vibration mode were measured as the variations of La and Nd molar ratio. Mechanical quality factor and dynamic range at $\alpha$=0.6 composition ceramics showed the highest value of 2, 691 and 52.37 dB, respectively. The tempearture coefficient of resonant frequency measured from -2$0^{\circ}C$ to 8$0^{\circ}C$ showed an excellent value of 5ppm/$^{\circ}C$ at $\alpha$ = 1 composition ceramics. ceramics.s.

  • PDF

A Rotordynamic and Stability Analysis of Process Gas Turbo-Compressor in accordance with API 617 Standard (API 617 규격에 의거한 프로세스 가스 터보압축기의 로터다이나믹 해석 및 안정성 검토)

  • Kim, Byung-Ok;Lee, An-Sung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.47-53
    • /
    • 2009
  • A rotordynamic and detailed stability analysis in accordance with API 617 standard were performed with a turbo-compressor, which is one of key rotating machinery in refinery, petroleum, and power plants. The system is composed of rotor shaft, impeller, sleeve hub, balance drum, and coupling hub. The rotor system is supported by tilting pad bearings, which has 5 pads and pad on loading condition. The rotordynamic analysis specified by API 617 includes the critical speed map, mode shape analysis, Campbell diagram, unbalance response analysis, and stability analysis. In particular, the specifications of stability analysis consist of a Level 1 analysis that approximates the destabilizing effects of the labyrinth seals and aerodynamic excitations, and Level 2 analysis that includes a detailed labyrinth seal aerodynamic analysis. The results of a rotordynamic analysis and stability analysis can evaluate the operating compressor health and can be utilized as a guide of its maintenance, repair and trouble solution.

Growth of $LiNbO_3$ single crystals and evaluation of the dependence of its piezoelectric properties on temperature ($LiNbO_3$단결정 성장 및 온도에 따른 압전 특성 평가)

  • 정화구;김병국;강길영;윤종규
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.2
    • /
    • pp.155-165
    • /
    • 1996
  • Growth of $LiNbO_3$ single crystal by Czochralski method was carried out to study the piezoelectric effects. Piezoelectric coefficients and elastic compliances of the $LiNbO_3$ single crystal were determined by the resonance method of length-extentional mode of bar resonator from the room temperature up to $100^{\circ}C$. Two dielectric constants of $LiNbO_3$ were also determined by measuring the capacitance of the plate specimen. Measured constants were piezoelectric coefficients $d_{15},d_{22},d_{31},d_{33}$ elastic compliances $s^E_{11},s^E_{33},2s^E_{13}+2s^E_{44},s^E_{14}$ and dielectric constants $K^T_{11},K^T_{33}$. As temperature increased, elastic compliances changed very slowly while piezoelectric coeffiecients and dielectric constant $K^T_{33}$ changed very rapidly. Electromechanical coupling constant of zyw ($45^{\circ}C$)-bar was as high as 0.51 in room temperature and nearly constant up to $1000^{\circ}C$. The increase of piezoelectric coefficients was mainly due to the increase of dielectric permittivity.

  • PDF

Dynamic Characteristic Analysis of 3-Level Half-bridge SSSC (3-레벨 반브리지로 구성된 SSSC의 동특성 분석)

  • 박상호;하요철;백승택;김희중;한병문
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.317-324
    • /
    • 2001
  • This paper proposes a SSSC based on 3-level half-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-but power system. The proposed SSC has six 3-level half-bridge inverters per phase, which operates in PWM mode. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

접합요소를 이용한 복합기초지반의 변형해석

  • Park, Byeong-Gi;Jeong, Jin-Seop;Lee, Mun-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1987.06a
    • /
    • pp.51-80
    • /
    • 1987
  • In this studys a numerical analysis on the defomation of foundation layer was carried out by indroducing joint element. The method using the joust element between adj assent different materials has been originally developed for rock behavior(Goodman, et al. 1968) . The application of this method to the interface between the footing and soil layer proved satisfactory(Ghaboussi p et at. 1973). Authors tried to obtain the deformation of rrcompound foundation layerg", which vertically or horizontally or both consists of the natural(or intact) soft clay layer and the layer improved artificially in order to get high stiff-fness with replacement or chemical treatment to reduce the excessively detrimental settlemellt or lateral displacement in case of banking or building the civil structure on the soft layer. The joint conditions were classified into three categories : contacts sliding and separation. By coupling "JOINT" as a subroutine into multi-purpose code for the finite element method of the foundatlion daveloped by authors on the assumption that shearing and normal displacement can not be coupledl which terms pinon-dilatant" and by selecting modified Cam-clay modeIP the deformation analysis was performmed. The results using joint element were compared with those secured without introduction of joint element Nain results analized are as follows : 1. For the prediction of settlement and lateral desplacement, the result due to joint element was evaluated larger, which was regarded safe. 2. For the determination of ultimate bearing capacetyi the value using joint element appeared smaller by 20%, which was also safe.

  • PDF

A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser (리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘)

  • Kim, Seul-Ki;Kim, Eung-Sang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.5
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.

A Study on the Analysis of Axial Vibration of Flexible Shafting System for Propulsion and Lift in Air Cushion Vehicle (공기부양선의 추진 및 부양축계 종진동 해석에 관한 연구)

  • Son, Seon-Tae;Kil, Byung-Lea;Kim, Jung-Ryul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.768-776
    • /
    • 2007
  • In this study, axial vibration analysis has been conducted on a propulsion and lift shafting system for an air cushion vehicle using ANSYS code. The shafting system is totally flexible multi-elements system including wood composite material of air propeller. aluminum alloy of lift fan and thin walled shaft with flexible coupling. The analysis calculated the axial natural frequencies and mode shapes of the shafting system taking into account an equivalent mass-elastic model for shafting system as well as the three-dimensional models for propeller blade and fan impeller. Such a flexible shafting system has very intricate vibrating characteristics and especially, axial natural frequencies of flexible components such as propeller blade and impeller of lift fan can be lower to the extent that causes a resonance in the range of operating revolution. The results for axial vibration analysis are presented and compared with the results of axial vibration test for lift fan conducted during Sea Trial.