Development of a 3.5 mm Coaxial Microcalorimeter for Microwave Power Standards (3.5 mm 동축형 미소열량계 개발과 전자파전력 측정표준 확립)

  • Kwon, Jae-Yong;Kim, Jeong-Hwan;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.989-996
    • /
    • 2009
  • RF and microwave power is a basic quantity in electromagnetic metrology which linked directly to major electro-magnetic quantities such as attenuation, RF voltage, antenna characteristics and field strength. This paper deals with a power meter and power sensor with associated theory for RF and microwave power measurement. We study the theory and the key aspects in design of a 3.5 mm coaxial microcalorimeter which works from 50 MHz to 26.5 GHz as a primary microwave power standard.

W-band MMIC Low Noise Amplifier for Millimeter-wave Seeker using Tuner System (Tuner System을 이용한 밀리미터파 탐색기용 W-band MMIC 저잡음 증폭기)

  • An, Dan;Kim, Sung-Chan;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.11
    • /
    • pp.89-94
    • /
    • 2011
  • In this paper, we developed the W-band MMIC low noise amplifier for the millimeter-wave seeker using the tuner system. The MHEMT devices for MMIC LNA exhibited DC characteristics with a drain current density of 692mA/mm, an extrinsic transconductance of 726mS/mm. The current gain cutoff frequency(fT) and maximum oscillation frequency($f_{max}$) were 195GHz and 305GHz, respectively. The fabricated W-band low noise amplifier represented S21 gain of 7.42dB at 94 GHz and noise figure of 2.8dB at 94.2 GHz.

Stereo 3 mm Millimeter Wave Imaging for Distance Estimation to Concealed Objects (스테레오 3mm 밀리미터파 영상을 이용한 은닉물체의 거리추정에 관한 연구)

  • Yeom, Seokwon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.1
    • /
    • pp.21-24
    • /
    • 2017
  • Passive millimeter wave (MMW) imaging penetrates clothing to detect concealed objects. The distances extraction to the concealed objects is critical for the security and defense. In this paper, we address a passive stereo 3 mm MMW imaging system to extract the longitudinal distance to the concealed object. The concealed object area is segmented and extracted by the k-means clustering algorithm with splitting initialization. The distance to the concealed object is estimated by the corresponding centers of the segmented objects. In the experimental two pairs (each pair for horizontal and vertical polarization) of stereo MMW images are obtained to estimate distances to concealed objects.

  • PDF

Extracorporeal Shock Wave Therapy for Painful Heterotopic Ossification after Traumatic Transtibial Amputation (외상성 하퇴 절단지에 발생한 이소성 골화증에 대한 체외충격파 치료)

  • Jeon, Hyun Min;Yang, Hee Seung;Seo, Jin Seok;Han, Seok Cheol;Kim, Wan Tae
    • Clinical Pain
    • /
    • v.19 no.1
    • /
    • pp.28-31
    • /
    • 2020
  • The incidence of heterotopic ossification (HO) was reported to be higher in combat-injured patients than in civilian trauma patients. HO is often considered a possible cause of residual limbs pain in amputee. Here, we report the case of a 21-year-old male, who underwent a traumatic right transfemoral and left transtibial amputation with two segments of painful HO around his left amputation site. We report the effect of extracorporeal shock wave therapy (ESWT) on size and pain associated with HO. After ESWT, the visual analog scale score decreased from 5~6 to 0~1 and the size of two masses decreased from 13.1 × 6.7 mm and 12.5 mm to 11.9 × 4.7 mm and 12.2 mm, respectively. To the best of our knowledge, this is the first case that has reported on the treatment of HO using ESWT for a traumatic transtibial amputation patient. The case suggests that ESWT could serve as a complementary treatment for HO in traumatic amputation patient.

Dynamic Properties of Tiny Piezoelectric linear Motor by Applied Voltage (인가 전압에 따른 초소형 압전 리니어 모터의 동특성)

  • Yoo, Kyoung-Ho;Ko, Hyun-Phill;Kang, Chong-Yun;Kim, Hyun-Jai;Ko, Tae-Kuk;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.62-63
    • /
    • 2005
  • Recently, a tiny piezoelectric linear motor using a vibration made of the transducer has been invented. The motor consists of a shaft, mobile element, and piezoelectric transducer using a piezoelectric radial mode bimorph disk. The fringe of the bimorph disk is fixed firmly which means this area has no degree of freedom. Therefore, the radial mode of the tranducer transfers to the flexurd mode. The mobile elements move along the shaft by the impact force generated by the flexurd mode of the piezoelectric transducer. The piezoelectric ceramic disks have thickness of 0.1 mm and diameter of 3.5 mm. The elastic disk is introduced between two disks of the ceramic, which has thickness of 0.1 mm and diameter of 3.8 mm. The fringe of the elastic disk is fixed by a brass cylinder which height is 1.2 mm. The Pyrex shaft is used which has diameter of 1 mm and height of 10 mm. The motors are operated at their resonant frequencies. The dynamic properties of the motor have been intensively measured and analyzed according to the applied voltage wave forms at the resonant frequencies. As the sawtooth and rectangular voltage waves are applied, the velocity, the thrust force, and the velocity dependence of the mobile position are measured. The dynamic characteristics are also analyzed within a period of each wave using laser vibrometer. The velocity of the mobile is moderately constant along the shaft. The better dynamic characteristics are obtained in the case of applying the rectangular wave.

  • PDF

Airside Performance of Fin-and-Tube Heat Exchangers Having Round Wave Fins (둥근 웨이브 핀-관 열교환기의 공기 측 전열 성능)

  • Kim, Nae-Hyun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.105-116
    • /
    • 2015
  • In this study, airside performance of round fin-and-tube heat exchangers are compared with that of the herringbone wave fin-and-tube heat exchangers with an aim to investigate the effect of fin shape on thermal performance. Results show that j factors of the round wave fin are 1.2~22% larger than those of herringbone wave fin. The f factors of the round wave fin are -1.0~29% smaller than those of herringbone wave fin for 1 or 2 row configuration. For 3 row configuration, f factors of the round wave fin are 8.3~23% larger. The reason may be attributed to the reduced recirculation zone in the valley of the fin for round wave fin as compared with that of the herringbone wave fin. For round wave fin, the effect of fin pitch on j and f factor is not significant. In addition, j factors decrease as the number of tube row increases. On the other hand, f factors are independent of the number of tube row. A new correlation was developed based on the present data.

Compressed Sensing Techniques for Millimeter Wave Channel Estimation (밀리미터파 채널 추정을 위한 압축 센싱 기법)

  • Han, Yonghee;Lee, Jungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2017
  • Millimeter wave (mmWave) bands are expected to improve date rate of 5G systems due to the wide available bandwidth. While severe path loss in those bands has impeded the utilization, short wavelength enables a large number of antennas packed in a compact form, which can mitigate the path loss. However, estimating the channel with a conventional scheme requires a huge training overhead, hence an efficient estimation scheme operating with a small overhead needs to be developed. The sparsity of mmWave channels caused by the limited scatterers can be exploited to reduce the overhead by utilizing compressed sensing. In this paper, we introduce compressed sensing techniques for mmWave channel estimation. First, we formulate wideband channel estimation into a sparse recovery problem. We also analyze the characteristics of random measurement matrix constructed using quantized phase shifters in terms of mutual incoherence.

A Study on the Measurement Technique of the Characteristics of Electromagnetic Wave Absorber Using $20 mm\phi$ Coaxial Tube ($20 mm\phi$ 동축관을 이용한 전파흡수체의 특성측정법에 관한 연구)

  • 김동일;정중식;백명숙;안영섭;정세모
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.2
    • /
    • pp.17-23
    • /
    • 1993
  • This study aims to measure the reflection loss and the material constants of the fabricated samples for electromagnectic wave absorber by using $20 mm\phi$ coaxial tube with the endshort-type. The authors have established the extraction algorithm of material constants by one port method, and proved that the results of the experiments were in agreement with the calculated ones. On the basis of the above results, the validity of the proposed measuring method is confirmed. This measurement method could be used effectively for the design of microwave absorber and for its evalustion.

  • PDF

Visualization of Underwater Sympathetic Detonation of High Explosives

  • Itoh, Shigeru;Hamada, Toru;Murata, Kenji;Kato, Yukio
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1822-1828
    • /
    • 2001
  • The experiment for the sympathetic detonation (Sudo et al., 1951) (Fukuyama et al., 1958) in water was conducted. Composition B (RDX: 64%, TNT: 36%, Detonation velocity: 7900m/s) was used for both donor (the thickness was 50mm, and the diameter was 31mm) and receptor charges. The distance between the donor and the receptor, and the thickness (5, 7.5, 10mm) of the receptor were varied in the experiments. In order to investigate the basic characteristics of the underwater sympathetic detonation of high explosive, the sympathetic detonation phenomena were visualized by a high-speed camera (HADLAND PHOTONICS, IMACON790) in forms of streak and framing photographs. The 200ns/mm streak velocity was 2㎲. Manganin gauges (KYOWA Electronic INSTRUMENTS CO. SKF-21725) were used for the pressure measurements. The gauges were set under the receptor. The pressures during the complete and incomplete explosions were measured.

  • PDF

Simulation and Measurement of Characteristic in 450 mm CCP Plasma Source

  • Park, Gi-Jeong;Seo, Sang-Hun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.508-508
    • /
    • 2012
  • CST microwave studio is used to simulate the plasma profile of the 450mm CCP source. Standing wave effect becomes important at the high frequency as the electrode radius increases. To solve plasma non-uniformity problem, we designed multi electrode chamber to decreasing standing wave effect. Simulation showed the ratio of input power of each electrode is related with electric field strength. The multi electrode was constructed and measured by 2D probe arrays using floating harmonic method. Uniformity of 450 mm CCP was changed by the ratio of input power of each electrode. We described this dependence with circuit model.

  • PDF