• Title/Summary/Keyword: mixed ratio

Search Result 3,387, Processing Time 0.026 seconds

A Study on the Dynamic Characteristics of Nitrogen Mixed Gas for Thermostatic Expansion Valve Sensing Blub (온도 감지식 팽창밸브 감온통 질소가스 혼합냉매의 동특성 연구)

  • Kim, Si-Young;Koo, Su-Jin;Ju, Chang-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • The pressure and temperature characteristics of mixed refrigerant gases in bulb for thermostatic expansion valve were studied using R22 refrigerant and $N_2$ gases. The characteristics of mixed refrigerant gases were investigated according to pressure variation and the variation of composition ratio of R22 refrigerant and $N_2$ gases in the temperature range of -$15^{\circ}C$~$15^{\circ}C$. The Maximum operating pressure(MOP) of mixed refrigerant gases were showed a tendency to decrease with decreasing the mixing ratio of $N_2$ gas. The characteristics in the case of the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were the same result as Reference refrigerant. In addition, the characteristics of the mixed refrigerant gases in the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were showed almost linear in the measurement range of pressure-temperature, and the physical properties also were showed similar results with Reference refrigerant. It was able to confirm that a MOP on the thermostatic expansion valve for sensing bulb can be maintained by adjusting the mixing ratio of R22 refrigerant and $N_2$ gases.

Co-combustion Characteristics of Mixed Coal with Anthracite and Bituminous in a Circulating Fluidized Bed Boiler (순환유동층 보일러에서 무연탄-유연탄의 혼합연소 특성)

  • Jeong, Eui-Dae;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.6 no.2
    • /
    • pp.70-77
    • /
    • 2010
  • This study investigated the characteristics of co-combustion of mixed anthracite (domestic and Vietnam) and bituminous coal (Sonoma, Australia) at circulating fluidized bed boiler in Donghae thermal power plant when mixing ratio of bituminous coal is variable. Co-combustion of bituminous coal contributes to improvement in general combustion characteristics such as moderately retaining temperature of furnace and recycle loop, reducing unburned carbon powder, and reducing discharge concentration of NOx and limestone supply owing to improvement in anthracite combustibility as the mixing ratio was increased. However, bed materials were needed to be added externally when the mixing ratio exceeded 40% because of reduction in generating bed materials based on reduction in ash production. When co-combustion was conducted in the section of 40 to 60% in the mixing ratio while the supplied particles of bituminous coal was increased from 6 mm to 10 mm, continuous operation was shown to be possible with upper differential pressure of 100 mmH2O (0.98 kPa) and more without addition of bed materials for the co-combustion of mixed anthracite and bituminous coal (to 50% or less of the ratio) and that of domestic coal and bituminous coal (to 60% of the ratio).

  • PDF

Effects of Density, Resin and Particle Types on Properties of Composites from Wood Particle Mixed with Coating Paper

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.57-64
    • /
    • 1999
  • This research was carried out to investigate the effects of density, resin and particle types on the physical and mechanical properties of the composites made from various wood particles mixed with coating paper. The experiment was designed to apply with three particles (flake, chip, and fiber) and three resin types (urea, phenol and PMDI resin). The mixed ratio of coating paper to wood particle was fixed on 50 to 50% in each board making. And also it was designed to apply for four density levels (0.6, 0.7, 0.8 and 0.9 g/$cm^3$) and four mixed formulations of coating paper to wood particle (10:90, 20:80, 30:70, and 40:60 %) to analyze clearly the effects of PMDI resin. Coating paper-wood particle composites have acceptable bending strength (MOR, MOE) though the mixed ratio of coating paper was increased, but have low internal bond strength and poor dimensional stability (WA, TS, LE). Composites with high density had higher mechanical properties but showed lower physical properties than composites with low density. In conclusion, at least up to 20% mixed ratios, coating paper-wood particle composites have acceptable physical and mechanical properties, and PMDI resin has possibility for coating paper-wood particle composite manufacture.

  • PDF

Conversion of Mixed Fat into Biodiesel in Plug Flow Reactor Using Alkali and Mixed Catalysts (관형반응기에서 알칼리 및 혼합촉매를 사용한 혼합지방의 바이오디젤화)

  • Hyun, Young-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • The continuous transesterification of mixed fat was done on the plug flow reactor packed with the static mixers. The transesterification using 0.5 wt% KOH, 0.8 wt% TMAH and mixed catalyst[40 v/v% KOH(0.5 wt%)+60 v/v% TMAH(0.8 wt%)] was conducted with the changes of molar ratios, weight percentage of beef, flow rates and number of static mixer's elements at $65^{\circ}C$. The overall conversion of mixed fat at 1:8 molar ratio, 50 wt% of beef and 24 of static mixer's elements increased until 0.7mL/min of flow rate. The overall conversion of mixed fat showed 96% at those conditions. So, the optimum operating conditions on tublar reactor were 1:8 molar ratio, 50 wt% of beef, 0.7 mL/min of flow rate and 24 of static mixer' s elements.

The study on the height standard and the slenderness ratio according to location types of Mixed-use Residential Tall buildings (초고층 주상복합건축물 입지유형에 따른 높이기준 및 세장비 제안에 관한 연구)

  • Sung, Lee-Yong;Kim, Yun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2779-2788
    • /
    • 2012
  • The housing market is now difficult because of excess of the increase rate of housing and long-term recession but high-rise mixed-use buildings can mix residential facilities with various demand facilities focusing and they have the advantages to secure open space and excellent view by high-rise apartment. But there are problems by hindrance of skyline formation and height of buildings. Therefore, the purpose of this study is to suggest the height standard and the slenderness ratio to location types of Mixed-use Residential Tall buildings. For the method of the study, term arrangement through literature search and the precedent research survey were first done, the level of urban design and the details related to the height of buildings were done as the case research focusing on the 16 cases in Seoul. The following results were drawn by suggesting the height standard and the slenderness ratio by location type based on them. First, the height of mixed-use building by location type in the level of urban design gets higher starting from the secondary center of the city and can be suggested as from less than 150m to more than 200m. Second, the slenderness ratio shall be planned as more than 1:3 because the area of the ground level of mixed-use building is large unlike Mixed-use Residential Tall buildings and visual passage shall be placed so that unity of openness and group formation will be planned. Third, for the height related to Mixed-use Residential Tall buildings, amendment of the special architectural district system and the special law related to super high-rise buildings shall be enacted.

A Study on the Control of Flame Shapes in Laminar Pre-Mixed Flames (층류 예혼합화염의 화염면 형상 제어에 관한 연구)

  • Lee, Won-Nam;Seo, Dong-Kyu
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.103-108
    • /
    • 2003
  • The control of flame shapes in a laminar pre-mixed flame has been experimentally investigated for propane/air pre-mixed laminar flames. Flames of different size and shapes are observed with heated wires or by controlling the equivalence ratio and flow rate of a mixture. The characteristics of the partitioning of a flame or the merge of flames are analyzed and explained by considering the balance between laminar flame speed and upstream mixture velocity. A combustor might be sized down while maintaining its heat production rate the same by partitioning a flame established in it. When the equivalence ratio of mixture is decreased, individual flames are merged together and the upstream mixture velocity can be practically decreased on a nozzle having opening ratio less than unity. As a result, the flame shape is to he adjusted until the newly established balanced condition is satisfied, and then. the stable combustion can be achieved again.

  • PDF

The Effect on Mixed Ratio of Recycled Engineering plastic Resin on the Shrinkage in Molded Parts (엔지니어링 플라스틱 재료의 재활용 혼합비가 성형품 수축에 미치는 영향)

    • Resources Recycling
    • /
    • v.13 no.3
    • /
    • pp.43-49
    • /
    • 2004
  • In this study. an experimental work was performed to mold tensile specimens by using the injection molding machine. Melt temperature, mold temperature and the mixed ratio of recycled resin were selected as processing parameters for studying the effect of those conditions on the shrinkage and weight of molded parts. As a result, the shrinkage was increased with the higher mold and melt temperature and it was more sensitive to the change of mold temperature. On the other hand, the weight of molded parts was decreased with the increment of mold and melt temperature.

A Study on Scheduling of Scrap Disposal for Deap-sea Fishing Industry Using a Mixed Integer Programming Model (혼합정수계획 모형을 활용한 원양산업의 최적 감척 일정계획 수립에 관한 연구)

  • Kim, Jae-Hee
    • Korean Management Science Review
    • /
    • v.27 no.2
    • /
    • pp.55-66
    • /
    • 2010
  • In Korea, deap-sea fishing industry plays an important role in a food industry. However, it is in a difficult situation because of the more competitive business environment. Therefore, there is a need to restructure the deap-sea fishing industry by scraping superannuated ships. This paper is designed to present scrap programs for deap-sea fishing industry of Korea. We performed ratio analysis to evaluate financial performance of fishing companies and then applied a mixed integer programming (MIP) model to identify optimal schedule for scraping. The results of the financial ratio analysis indicates that it is legible to provide governmental aid to Atlantic trawl, Northern Pacific trawl, and Indian ocean trawl with minimum required rate of return (MRR) of 3%, and the Atlantic strip fishing industry is qualified to receive the governmental aid with MRR value of 5%. Furthermore, by applying the MIP model to develop scrap planning, we demonstrate how our model can be used to restructure the deap-sea fishing industry of Korea.

Strength Characteristics of Cement-Mixed Soil (시멘트 혼합토의 강도 특성)

  • Kim, Sang-Chul;Lee, Sang-Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.3
    • /
    • pp.49-56
    • /
    • 2005
  • This study was conducted by the tests of materials engineering and soil mechanics to see the strength characteristics of the ‘Cement-Mixed Soil'. To sum up my experiments, I would like to present the results which are the theoretical base and fundamental data to establish the standard design including the design of mixing proportions of the soil as a construction material. In conclusion, in this study the optimum cement mixing ratio is $9\%$ and in this ratio the optimum moisture content of compaction work is $19.3\%$ from the analysis of the strength characteristics, as well as in consideration of the economic profits and nature familiar facts.

Numerical Study of Unsteady Mixed Convection in a Cavity with High Viscous Fluid (캐비티 내 고 점성유체의 비정상 흔합대류에 관한 수치해석적 연구)

  • Bae, D.S.;Cai, Long Ji
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.11-17
    • /
    • 2009
  • A numerical study of unsteady mixed convection in a cavity with high viscous fluid is presented. Finite volume method was employed for the discretization and PISO algorithm was used for calculating pressure term. The parameters governing the problem are the Rayleigh number ($10^3\;{\leq}\;Ra\;{\leq}\;10^5$), the Reynolds number (0 < Re $\leq$ 1), and the aspect ratio (0.5 $\leq$ AR $\leq$ 2). The fluid used is silicon oil, a high prandtl number fluid, Pr = 909.1. The results show velocity vectors and temperature distributions. It is found that the periodic flows in a cavity are observed at very low Reynolds numbers, and the period of periodic flow decreases with increasing Reynolds and Rayleigh numbers, and increases with increasing aspect ratio. Also, the Reynolds number range of periodic flow increases with increasing Rayleigh numbers and aspect ratio.

  • PDF