• Title/Summary/Keyword: mixed construction

Search Result 1,274, Processing Time 0.036 seconds

The Properties of Cement Paste Mixed with Carbon Nanotubes Dispersion Solution (탄소나노튜브 분산용액을 혼입한 시멘트 페이스트의 특성 변화)

  • Park, Sung-Hwan;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.201-202
    • /
    • 2021
  • Currently, the domestic construction industry is trying to expand the range of building materials due to overload of growth. In particular, several studies are being conducted to make up for the weakness of building materials by solving problems such as reduction of tensile strength and brittle behavior of concrete. Among them, efforts to maximize the use of carbon nanotubes (CNT) that has excellent mechanical and electrical conductivity properties are continuing. However, CNT is hydrophobic and have a strong Van der Waals force between particles, making it difficult to obtain an effective dispersion state. Therefore, in this study, various kinds of surfactants like DOC (Sodium Deoxycholate), PVP (Polyvinylpyrrolidone), and PCE (Polycarboxylate ester) were added to improve the dispersibility of CNT, and analyzed the changes in the properties of the cement paste mixed with them.

  • PDF

50MPa Ternary Non-Cement Mortar Strength Development Mixing with Hybrid Fibers Cured by Room Temperature (상온양생에 의한 하이브리드 섬유를 혼입한 50MPa급 3성분계 무시멘트 모르타르 강도발현)

  • Cho, Sung-Won;Cho, Sung-Eun;Kim, Young-su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.179-180
    • /
    • 2020
  • CO2 emissions are caused by cement manufacturing process. To solve this problem construction industry are using industrial by-products to replace cement. In this study, three different industrial by products were used and mixed with hybrid fibers to enhance bond strength. As the result, Regardless of the mixing rate of silica fume, the compressive strength of the ternary non cent mortar was higher than that of OPC and binary. And mixed hybrid fibers cured by room temperature compressive strength were 23% higher than those without hybrid fibers.

  • PDF

Effect of Stress Ratio on Fatigue Crack Growth in Mixed Mode(I+II) (혼합모드(I+II)에서 피로균열진전에 미치는 응력비의 영향)

  • Gong, Byeong-Chae;Choi, Myoung-Su;Kwon, Hyun-Kyu;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.90-96
    • /
    • 2009
  • The loading condition of actual construction works is complex. The shear effect of mixed-mode load component are crack propagation mechanism in step larger than the crack initial mechanism. Therefore, in this study received a mixed-mode loading on fatigue crack stress ratio on crack propagation path and speed of progress to learn whether stress affects crack propagation. ${\Delta}$ P a constant state of fatigue tests in Mode I, II give the same stress ratio, frequency 10Hz, sinusoidal waveform was used. A lower stress ratio fatigue crack propagation angle is small. This is less affected by the Mode II. Therefore, a mixed-mode fatigue crack propagation is to progress by the Mode. Stress ratio in a mixed mode crack in the path of progress and found a lot of impact.

  • PDF

An Experimental Study on the Engineering Properties of Concrete using Fine Aggregate of PS ball Slag (풍쇄슬래그 잔골재를 사용한 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Lee Sang-Soo;Song Ha-Young;Kim Eul-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.3 s.21
    • /
    • pp.107-114
    • /
    • 2006
  • In this study, the experiment was carried out to investigate and analyze the engineering properties of concrete using fine aggregate of PS bal slagl. The main experimental variables were water/cement ratio 30, 40, 50(%), water content $170kg/m^3$, replacement ratio of slag fine aggregate 0, 25, 50, 75(%) in experiment I and water/cement ratio 30, 40, 50(%), water content 165, 170, 175($kg/m^3$), replacement ratio of fine aggregate of PS ball 0, 50 in experiment II. According to the test results, the principle conclusions are summarized as follows (1) The workability of slag fine aggregate-mixed concrete tends to improve, as the replacement rate increases. (2) The air content of slag fine aggregate-mixed concrete tends to decrease, as the replacement rate increases. (3) The unit volume weight of slag fine aggregate-mixed concrete tends to significantly increase, as the replacement rate increases. (4) The compressive strength of slag fine aggregate-mixed concrete tends to show more increasing propensity, in case the curing period is relatively long, as the replacement rate increases.

Optimal Road Maintenance Section Selection Using Mixed Integer Programming (혼합정수계획법을 활용한 도로포장 보수구간 선정 최적화 연구)

  • Cho, Geonyoung;Lim, Heejong
    • International Journal of Highway Engineering
    • /
    • v.19 no.3
    • /
    • pp.65-70
    • /
    • 2017
  • PURPOSES : Pavement Management System contains the data that describe the condition of the road. Under limited budget, the data can be utilized for efficient plans. The objective of this research is to develop a mixed integer program model that maximizes remaining durable years (or Lane-Kilometer-Years) in road maintenance planning. METHODS : An optimization model based on a mixed integer program is developed. The model selects a cluster of sectors that are adjacent to each other according to the road condition. The model also considers constraints required by the Seoul Metropolitan Facilities Management Corporation. They select two lanes at most not to block the traffic and limit the number of sectors for one-time construction to finish the work in given time. We incorporate variable cost constraints. As the model selects more sectors, the unit cost of the construction becomes smaller. The optimal choice of the number of sectors is implemented using piecewise linear constraints. RESULTS : Data (SPI) collected from Pavement Management System managed by Seoul Metropolitan City are fed into the model. Based on the data and the model, the optimal maintenance plans are established. Some of the optimal plans cannot be generated directly in existing heuristic approach or by human intuition. CONCLUSIONS:The mathematical model using actual data generates the optimal maintenance plans.

The Fundamental Study on Reusing Method of Ready-Mixed Concrete Sludge as Cement Binder (시멘트계 결합재로서 레미콘 슬러지의 재활용 방안에 관한 기초적 연구)

  • Park Jin-Sub;;;Kang Byeung-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.21-26
    • /
    • 2004
  • This study deals with the Hydrated Ability of the Ready-Mixed Concrete's Sludge which is the recycling technology of that sludge. The experiment gathers sludge from Ready-mixed factory. shatters these into pieces in dry condition and understands the differences between current using Portland cement. And then. this examines the possibility of the recycle as a bonding agent through the Compressive Strength and considers the recovery of the hydration. This experiment concludes the same Chemical Composition with the normal Portland cement. while. under the appropriate procedure in hydration recovery. this sludge can be used as the bonding agent in cement. The chemical composition of solid Remicon sludge shows that it has 1.8 times $SiO_2$ than the normal Portland cement. meaning lots of aggregate in Remicon sludge. Also. the specific gravity of Remicon sluge increases with the rise of Baking Temperature and has no difference between 2.77 and 2.94. The mortar flow used for combining the baking material of Remicon sludge does was not changed and is the highest between $750^{\circ}C{\cdot}120min\;and\;800^{\circ}C{\cdot}180min$. Additionally. the Compressive Strength increases with the age, certifying the same Hydrated Ability like cement and the best condition for hydration is $750^{\circ}C{\cdot}120min.$

  • PDF

Hydrostatic Pressure Resistance Performance Testing of Cement Mixed Siliceous Powder Waterproofing Coationgs (규산질계 분말형 도포방수재의 내투수성 성능평가 연구)

  • Park, So-Young;Kwon, Si-Won;Kim, Soo-Yeon;Kim, Byong-il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.31-32
    • /
    • 2018
  • Lately, cement mixed siliceous powder waterproofing coating has been used as a waterproofing material in the wet environment condition of an underground concrete structure. Underground is exposed to environmental influences such as pressure of ground water, pressure of soil. However, the quality standard for pressure (water pressure, earth pressure) is not specified in the specification of the cement mixed siliceous powder waterproofing coating. Therefore, in this study, the permeability test was carried out based on the assumption that the durability should be verified in consideration of the environmental aspects of the material in actual field. As a result of the test, the permeability was generated from the inorganic single type material, but it was caused by the sealing failure and the test error, and the permeability was not generated in most of the materials. The results of this study will be analyzed by reviewing the physical properties of the material, and the research direction will be resumed.

  • PDF

Chloride Penetration Resistance of Concrete Mixed with High Volume Blast Furnace Slag (고르슬래그미분말을 다량 혼입한 콘크리트의 염분침투저항성)

  • Park, Ki-Cheol;Kim, Dong-Hun;Park, Shin;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.40-41
    • /
    • 2014
  • As a result of strength test on BFS concrete, those mixed with 30% and 50% of BFS8000, respectively, showed higher or equivalent strength compare to OPC. As a result of test of chloride penetration on BFS, diffusion coefficients of concrete mixed with 30% FA4000 and FA5000, respectively, showed to restrain average 6.5% of diffusion coefficient compared to OPC. And in case of BFS concrete, those mixed with BFS6000 and BFS8000, restrained diffusion of chloride ions 253% and 336%, respectively, compared to OPC. Therefore, Mixing 50% of BFS was most efficient in order to maximize restraint of chloride penetration according to metathesis of large amount. In this study, when mixing BFS to concrete for long-run durability and restraint against chloride penetration, for BFS, as fineness was higher and mixing it to concrete with less or equivalent 50% of replacement rate, there were results of higher strength compared to OPC and more efficient restraint of chloride ions.

  • PDF

Table Flow Evaluation of CNT-Mixed Fiber Reinforced Cement Composite by Dispersion Method (분산방법에 따른 CNT를 혼입한 섬유보강 시멘트복합체의 유동성 평가)

  • Kim, Moon-Kyu;Kim, Gyu-Yong;Pyeon, Su-Jeong;Choi, Byung-Cheol;Park, Jun-Young;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.95-96
    • /
    • 2023
  • In this study, the table flow of fiber reinforced cement composites mixed with CNTs dispersed differently according to the dispersion method was evaluated. The mixture was composed of plain mixture according to the presence or absence of ultrasonic dispersion and PCE-based dispersants A and B of 0.5% and 1.0%, respectively, CNT was mixed with 0.03% of cement weight and fiber was mixed with 1.5% of total volume. As a result of the experiment, NC-A0.5 showed a fluidity similar to that of P without CNT. The fluidity of NC-A0.5 and P-N showed a similar tendency, which is considered to be due to the distribution of evenly dispersed CNT particles without agglomeration between cement particles due to the dispersant. NC-B0.5 showed a similar level of firmness to P-U, but after hitting 250 mm, B Agent seems to have a significant effect on liquidity improvement.Both NC-A1.0 and NC-B1.0 seem to have increased flow due to excessive dispersion.

  • PDF

Comparison the Effect of In-situ Mixing Method and Mixed Laying Method for Construction of Stabilizing Layer on Heavy Metal Contaminated Soil (중금속 오염토양 안정화층 시공을 위한 원위치 교반방식과 혼합포설방식의 효과비교)

  • Lee, Sang-Moo;Kim, Jin-Hwan;Yun, Yeo-Joon;Kim, Yoon-Su;Park, Nam-Seo
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.505-514
    • /
    • 2015
  • In this study, a stabilizing equipment was developed to resolve the problems of existing stabilization construction method for contaminated soil. The field application and workability of the stabilizing equipment were verified through field demonstration tests and laboratory tests. The field application of the stabilizing equipment was identified through field demonstration tests. As a result of laboratory tests for field mixed soil, the mixing capability of stabilizer of the developed construction method was better than that of existing construction method.