• Title/Summary/Keyword: mixed array

Search Result 100, Processing Time 0.023 seconds

A Numerical Study of the Heat Transfer Characteristics in a Printed Circuit Board (PCB내의 열전달특성에 관한 수치적 연구)

  • Pak, H.Y.;Park, K.W.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.461-472
    • /
    • 1995
  • The interaction of laminar mixed convection and surface radiation in a two-dimensional channel with an array of rectangular blocks is analyzed numerically. Three blocks are maintained at high temperature and the other bottom and top horizontal walls are insulated. Discrete ordinate method(DOM) is introduced to analyze the radiative heat transfer. The effects of the variations of Reynolds number and channel specifications on the heat transfer characteristics are investigated. The average Nusselt numbers along the block surfaces are correlated and presented in terms of Reynolds number and dimensionless geometric parameters such as the block spacing, height and channel spacing. For the conditions considered in this study, average Nusselt numbers along the block surfaces are strongly influenced by the channel spacing and Reynolds number but weakly influenced by the block spacing and block height.

  • PDF

Hearing Rehabilitation with Combined Electroacoustic Stimulation and Ossiculoplasty

  • Lee, Jeon Mi;Na, Gina;Choi, Jae Young
    • Korean Journal of Audiology
    • /
    • v.25 no.2
    • /
    • pp.110-114
    • /
    • 2021
  • We report a case of hearing rehabilitation following combined cochlear implantation and ossiculoplasty. A 71-year-old patient visited the clinic for right-sided mixed hearing loss. We targeted neural and conductive components, performing two different operations simultaneously. At two months post-operative, the patient showed satisfactory results with respect to hearing threshold and speech comprehension. Our experience suggests that careful evaluation of patients and consideration of the diverse array of available treatment strategies can be used to provide personalized rehabilitation with maximal effectiveness. To the best of our knowledge, this is the first report to take such an integrated approach to treat hearing impairment and is thus likely to have clinical importance for otologists.

Hearing Rehabilitation with Combined Electroacoustic Stimulation and Ossiculoplasty

  • Lee, Jeon Mi;Na, Gina;Choi, Jae Young
    • Journal of Audiology & Otology
    • /
    • v.25 no.2
    • /
    • pp.110-114
    • /
    • 2021
  • We report a case of hearing rehabilitation following combined cochlear implantation and ossiculoplasty. A 71-year-old patient visited the clinic for right-sided mixed hearing loss. We targeted neural and conductive components, performing two different operations simultaneously. At two months post-operative, the patient showed satisfactory results with respect to hearing threshold and speech comprehension. Our experience suggests that careful evaluation of patients and consideration of the diverse array of available treatment strategies can be used to provide personalized rehabilitation with maximal effectiveness. To the best of our knowledge, this is the first report to take such an integrated approach to treat hearing impairment and is thus likely to have clinical importance for otologists.

Immunohistochemical Array Analysis of Cemento-Ossifying Fibroma Exhibiting aneurysmal Cystic Changes (백악-골화섬유종에서 보이는 동맥류성 낭종변화의 면역조직화학염색 배열분석)

  • Lee, Sang Shin;Kim, Yeon Sook;Lee, Suk Keun
    • The Korean Journal of Oral and Maxillofacial Pathology
    • /
    • v.42 no.6
    • /
    • pp.189-198
    • /
    • 2018
  • A 31 years old female had been suffered from a bony swelling in right premolar region of the mandible for 12 years, recently grown rapidly. A fistula tract developed on the right anterior mandibular border, but the lesion was relatively asymptomatic. In the radiological examination, the tumor mass was irregularly mixed with radiolucent and radiopaque areas, forming multiple cystic spaces. Under the diagnosis of calcifying odontogenic cyst, the mandibular mass was resected and examined pathologically. After decalcification, the dissected tumor mass showed multiple small cystic spaces and calcifying fibrous tissue, mimicking calcifying odontogenic cyst or ameloblastoma. Histological observation showed many calcifying cementoid materials and ossifying trabeculae. The cystic spaces were turned out to be dilated vascular channels lined by endothelial cells, containing plasma fluid. However, the main lesion was diagnosed as cemento-ossifying fibroma (COF), and the atypical vascular channels were greatly dilated and gradually expanded the whole tumor mass. The present COF was examined through immunohistochemical (IHC) array, and investigated for tumor cell characteristics, exhibiting abnormal ossification and aneurysmal cystic changes. IHC array disclosed that the tumor cells grew progressively in the lack of apoptosis, and that they showed lower expression of RUNX2 than BMP-2, RANKL, and OPG, and increases of protein expression in $HIF-1{\alpha}$, VEGF-A, and CMG2. These data suggested that the reduced expression of RUNX2, osteoblast differentiation factor, be relevant to abnormal ossification of COF, and that the consistent expressions of angiogenesis factors be relevant to de novo angiogenesis in COF, subsequently resulted in aneurysmal cystic changes.

Preliminary Study on Rapid Measurement of Gross Alpha/Beta and 90Sr Activities in Surface Soil by Mobile ZnS(Ag)/PTV Array and Handheld PVT Rod with Gated Energy Channels

  • Lee, Chanki;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.194-203
    • /
    • 2021
  • Background: Surface soil radiation monitoring around nuclear facilities is important to classify and characterize the contaminated areas. A scanning and direct measurement technique can survey the sites rapidly before starting sampling analysis. Materials and Methods: Regarding this, we test and suggest a measurement technique for gross alpha/beta and 90Sr activities in surface soil based on a mobile ZnS(Ag)/PVT (polyvinyltoluene) array and a handheld PVT rod, respectively. To detect 90Sr selectively in soil mixed with naturally occurring radioactive materials, chosen energy channel counts from the multichannel analyzers were used instead of whole channel counts. Soil samples contaminated with exempt liquid 90Sr with 1 Bq·g-1, 3 Bq·g-1, and 10 Bq·g-1 were prepared and hardened by flocculation. Results and Discussion: The mobile ZnS(Ag)/PVT array could discriminate gross alpha, gross beta, and gamma radiation by the different pulse-shaped signal features of each sensor material. If the array is deployed on a vehicle, the scan minimum detectable concentration (MDC) range will be about 0.11-0.17 Bq·g-1 at 18 km·h-1 speed, highly sensitive to actual sites. The handheld PVT rod with 12 mm (Φ) × 20 mm (H) size can directly measure 90Sr selectively if channels on which energies are from 1,470 and 2,279 keV are gated, minimizing crossdetection of other radionuclides. These methods were verified by measuring soil samples fabricated with homogeneous 90Sr concentrations, showing static MDC of 2.16 Bq·g-1 at a measurement time of 300 seconds. Conclusion: Based on the results, comprehensive procedures using these detectors are suggested to optimize soil sites survey.

Simple closed-form solution for a single source estimation in mixed far-field and near-field conditions (원근 혼합환경에서 간단한 닫힌 형식을 이용한 단일 음원 위치 추정 기법)

  • Jung, Tae-Jin;Lee, KyunKyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.35-41
    • /
    • 2016
  • Based on correlation and least square method, a closed-form algorithm for estimating the location of mixed far-field and near-field source is presented using the Uniform Circular Array (UCA). Recently, for a homogeneous circular arrangement case, a correlation based closed-form algorithm is proposed to estimate 2-D angle (azimuth, elevation) and the extended algorithm is proposed to 3-D location (azimuth, elevation, range). These algorithms assume the far-field source or near-field source only. Therefore, for mixed source localization, the proposed algorithm estimates source location with the assumption of far-field source, and then estimates the range to distinguish the far-field from the near-field source. For both cases, numerical experiments have been performed, which confirmed the validity of the proposed algorithm.

Low cost 2.4-GHz VCO design in 0.18-㎛ Mixed-signal CMOS Process for WSN applications (저 가격 0.18-㎛ 혼성신호 CMOS공정에 기반한 WSN용 2.4-GHz 밴드 VCO설계)

  • Jhon, Heesauk;An, Chang-Ho;Jung, Youngho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.325-328
    • /
    • 2020
  • This paper demonstrated a voltage-controlled oscillator (VCO) using cost-effective (1-poly 6-metal) mixed signal standard CMOS process. To have the high-quality factor inductor in LC resonator with thin metal thickness, patterned-ground shields (PGS) was adopted under the spiral to effectively reduce the ac current of low resistive Si substrate. And, because of thin top-metal compared with that of RF option (2 ㎛), we make electrically connect between the top metal (M6) and the next metal (M5) by great number of via array along the metal traces. The circuit operated from 2.48 GHz to 2.62 GHz tuned by accumulation-mode varactor device. And the measured phase noise of LC VCO has -123.7 dBc/Hz at 1MHz offset at 2.62 GHz and the dc-power consumption shows 2.07 mW with 1.8V supply voltage, respectively.

Sensing Characterization of Metal Oxide Semiconductor-Based Sensor Arrays for Gas Mixtures in Air

  • Jung-Sik Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.5
    • /
    • pp.195-204
    • /
    • 2023
  • Micro-electronic gas sensor devices were developed for the detection of carbon monoxide (CO), nitrogen oxides (NOx), ammonia (NH3), and formaldehyde (HCHO), as well as binary mixed-gas systems. Four gas sensing materials for different target gases, Pd-SnO2 for CO, In2O3 for NOx, Ru-WO3 for NH3, and SnO2-ZnO for HCHO, were synthesized using a sol-gel method, and sensor devices were then fabricated using a micro sensor platform. The gas sensing behavior and sensor response to the gas mixture were examined for six mixed gas systems using the experimental data in MEMS gas sensor arrays in sole gases and their mixtures. The gas sensing behavior with the mixed gas system suggests that specific adsorption and selective activation of the adsorption sites might occur in gas mixtures, and allow selectivity for the adsorption of a particular gas. The careful pattern recognition of sensing data obtained by the sensor array made it possible to distinguish a gas species from a gas mixture and to measure its concentration.

Low Power ADC Design for Mixed Signal Convolutional Neural Network Accelerator (혼성신호 컨볼루션 뉴럴 네트워크 가속기를 위한 저전력 ADC설계)

  • Lee, Jung Yeon;Asghar, Malik Summair;Arslan, Saad;Kim, HyungWon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1627-1634
    • /
    • 2021
  • This paper introduces a low-power compact ADC circuit for analog Convolutional filter for low-power neural network accelerator SOC. While convolutional neural network accelerators can speed up the learning and inference process, they have drawback of consuming excessive power and occupying large chip area due to large number of multiply-and-accumulate operators when implemented in complex digital circuits. To overcome these drawbacks, we implemented an analog convolutional filter that consists of an analog multiply-and-accumulate arithmetic circuit along with an ADC. This paper is focused on the design optimization of a low-power 8bit SAR ADC for the analog convolutional filter accelerator We demonstrate how to minimize the capacitor-array DAC, an important component of SAR ADC, which is three times smaller than the conventional circuit. The proposed ADC has been fabricated in CMOS 65nm process. It achieves an overall size of 1355.7㎛2, power consumption of 2.6㎼ at a frequency of 100MHz, SNDR of 44.19 dB, and ENOB of 7.04bit.

Design of Low-complexity FFT Processor for Narrow-band Interference Signal Cancellation Based Array Antenna (배열 안테나 기반 협대역 간섭신호 제거를 위한 저면적 FFT 프로세서 설계 연구)

  • Yang, Gi-jung;Won, Hyun-Hee;Park, Sungyeol;Ahn, Byoung-Sun;Kang, Haeng-Ik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.621-622
    • /
    • 2017
  • In this paper, a low-complexity FFT processor is proposed for narrow-band interference signal cancellation based array antenna. The proposed FFT pocessor can support the variable length of 64, 128 and 512. By reducing number of non-tirval multipliers with mixed radix-4/2/4/2/4/2 algorithm and flexible multi-path delay commutator(MDC) architecture, the complexity of the proposed FFT processor is dramatically decreased. The proposed FFT processor was designed in Xilinx system generator and Implemented with Xilinx Virtex-7 FPGA. With the proposed architecture, the number of slices for the processor is 11454, and the number of DSP48s is 194.

  • PDF