• 제목/요약/키워드: minitab PGM

검색결과 2건 처리시간 0.014초

실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구 (A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation)

  • 이병설;최충석
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

디지털 측정기로 측정된 급기가압 제연구역의 출입문 개방력에 대한 신뢰성 분석 및 최적 조건 제시 (Reliability Analysis of Access Door Opening Force Measured with a Digital Force Gauge of a Pressurized Smoke Control Zone and Presentation of Optimum Conditions for the Opening Force)

  • 이재오;최충석
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.468-473
    • /
    • 2016
  • 본 연구는 디지털 측정기(Digital Force Gauge)를 이용해 급기가압 제연구역 출입문의 개방력을 측정하여 신뢰성을 검증하는데 있다. 개방력은 제연구역에 급기가압 기류가 들어가기 전과 후의 개방 부하를 측정하였다. 측정값은 미니탭 프로그램(Minitab PGM)의 AD(Anderson Darling) 통계분석법으로 신뢰도를 검증하였다. 분석된 P값은 제연설비의 작동 전과 후의 일부 층을 제외하고는 0.05 이상을 나타낸 것으로 보아 95% 신뢰도가 있는 것으로 해석된다. 측정값의 정규분포는 제연설비의 작동 여부와 관계가 없었으며, 계측기의 정밀도는 신뢰할 수 있는 것으로 분석된다. 그리고 급기가압 제연설비의 최적설계 조건은 계측기의 정밀도와 신뢰성, 측정자의 바른 자세, 출입문의 동일한 조건 등이 주요 인자로 판단된다. 따라서 급기가압 제연구역 출입문의 개방력의 측정은 디지털 측정기가 적합한 것으로 판단된다. 또한 효과적인 개방력의 측정은 측정자의 자세 표준화, 출입문의 초기 개방력의 설정 등이 주요 변수로 작용하고 있음을 알 수 있었다.