• Title/Summary/Keyword: minimum safety factor

Search Result 149, Processing Time 0.029 seconds

The prediction of the critical factor of safety of homogeneous finite slopes subjected to earthquake forces using neural networks and multiple regressions

  • Erzin, Yusuf;Cetin, T.
    • Geomechanics and Engineering
    • /
    • v.6 no.1
    • /
    • pp.1-15
    • /
    • 2014
  • In this study, artificial neural network (ANN) and multiple regression (MR) models were developed to predict the critical factor of safety ($F_s$) of the homogeneous finite slopes subjected to earthquake forces. To achieve this, the values of $F_s$ in 5184 nos. of homogeneous finite slopes having different slope, soil and earthquake parameters were calculated by using the Simplified Bishop method and the minimum (critical) $F_s$ for each of the case was determined and used in the development of the ANN and MR models. The results obtained from both the models were compared with those obtained from the calculations. It is found that the ANN model exhibits more reliable predictions than the MR model. Moreover, several performance indices such as the determination coefficient, variance account for, mean absolute error, root mean square error, and the scaled percent error were computed. Also, the receiver operating curves were drawn, and the areas under the curves (AUC) were calculated to assess the prediction capacity of the ANN and MR models developed. The performance level attained in the ANN model shows that the ANN model developed can be used for predicting the critical $F_s$ of the homogeneous finite slopes subjected to earthquake forces.

A Study on the Structural Safety Evaluation of Light Weight Damper for Offshore Rigs (해양시추선용 경량수밀댐퍼의 구조안전성 평가에 관한 연구)

  • Jang, Ji-Seong;Ji, Sang-Won;Han, Seung-Hun
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.80-86
    • /
    • 2016
  • In this study, The watertight damper was designed to improve conventional DN 350A butterfly valve. The FSI(Fluid-Structure Interaction) analysis has performed to investigate the safety factor for the watertight damper. When watertight damper of disk was closed, the disk of pressure value is constant. However depending on the opening angle of disk, the flow velocity and pressure are changed. The maximum velocity was appeared at the end of disk on the small outlet area of duct. When the opening angel of disk is $90^{\circ}$, the maximum velocity was appeared at the center of ending disk. So we were found the opening angle of disk is bigger, the flow rate is increased and velocity is also increased from the result of FSI analysis. We can find the least deformation and stress when the opening angel of damper is $90^{\circ}$. When the $45^{\circ}$ opening angle of disk, the largest deformation and stress was found and the minimum safety factor 1.3 was calculated. As a result, we found that the structure of watertight damper is safe enough irrespective of opening angel.

A Study on the Fire Safety Performance of Interior Surface Materials in a Building (건축물의 실내건축 재료에 관한 화재안전성 연구)

  • Seo, Su-Eun;Shin, Seung-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF

Study on Optimum Design for Embankment Construction on Soft Ground Treated by SCP (SCP개량지반상에 성토시공 시 최적설계에 관한 연구)

  • Chae, Jong-gil;Park, Yeong-Mog;Jung, MinSu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6C
    • /
    • pp.251-258
    • /
    • 2009
  • In this study, the optimum design conditions for embankment construction on soft clay layer improved by soil compaction pile (SCP) are discussed by comparing the practical design method to the reliability design which is based on the loss function and advanced first order second moment (AFOSM) method. The results are summarized as follows; 1) the relationship between safety factor and failure probability becomes heavy exponentially, failure probability decreases rapidly till 1% approximately until safety factor is smaller than 1.2 and after then, failure probability decrease gradually along the increase of the safety factor. The design safety factor of 1.2 may be the critical value that has been established on considering both relationships appropriately, 2) the safety factor of 1.15 at the minimum expected total cost is a little smaller than the design safety factor of 1.2 and the failure probability is about 1%, 3) the sensitivities of the ratio of stress share and the internal friction angle of sand is larger than the variables related the undrained shear strength of soft layer. This result means that the distribution characteristic of n and ${\phi}$ influences on the stability analysis considerably and they should be considered necessarily on stability analysis of embankment on soft layer improved by SCP, 4) new failure points of the input variables at the design safety factor of 1.2(below failure probability of 0.1~0.3%) is far 1~2 times of standard deviation from the initial design values of themselves.

An Analytical Study on the Slope Safety Factor Considering Various Conditions (다양한 조건을 고려한 사면안전율에 관한 해석적 연구)

  • Park, Choon-Sik;Ahn, Sang-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.5
    • /
    • pp.31-41
    • /
    • 2019
  • This paper demonstrates safety factor for effective planning at initial stage by utilizing results on changes of safety factor according to various conditions of slop and examines impacts of factors that affect slope safety factors as well. Firstly, it describes shear strength which satisfies minimum allowable safety factor: 1.20 depending on height and slope. As the height increases by 5.0 m, the safety factors decrease by 0.04 while it tends to consistently reduce by approximately 20%, 30% and 40% after height goes to 10.0 m. As slope reduces by about 0.3, the safety factors increases by 0.4, which shows the rate of safety factors on slope grows by about 10%, 20% and 30% on lowering slope. When cohesion goes up by 10.0 kPa the safety factors increases by around 40% respectably while the angle of internal friction grows by $5^{\circ}$, it increases by about 8%. The rate of safety factors is identified as $Fs=3.86H^{-0.59}$, Fs = 0.43 s, Fs = 0.04 c, $Fs=0.02{\phi}$ depending on height, slope and shear strength. The safety factor with rainfall infiltration tends to increase by 18% compared to the condition of saturated surface on earth.

Structural Analysis on Clamp Guide Bar of Drawing Process System for SUS Hexagonal Bar (SUS 육각봉 인발성형 시스템의 클램프 가이드 바에 관한 구조해석)

  • Lee, Young-Sik;Yang, Young-Joon
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.796-802
    • /
    • 2018
  • In order to remove rust and impurities from surface of raw SUS circular bar, peeling machine is used to make lustrous and clean surface of SUS circular bar. Drawing process system is used to manufacture SUS hexagonal bar. SUS hexagonal bar have been widely used to make hexagonal bolt/nut, adapter and fittings and so on. The purpose of this study is to investigate the stabilities for guide bar of clamp in drawing process system. As the results, the guide bar showed structural stability in cases of below load of 50 Ton and over hook radius of 3.0mm. Further as the thickness of guide bar hooking with jaw was increased, minimum safety factor was decreased.

High Power Factor Three-phase AC-DC Flyback Converter Module Using Zero Voltage Switching (영전압 스위칭을 이용한 고역률 3상 AC-DC Flyback 컨버터 모듈)

  • Lee, J.P.;Choi, J.Y.;Song, J.H.;Choy, I.;Yoon, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2701-2703
    • /
    • 1999
  • A new mode of parallel operation of a modular 3-phase AC-DC Flyback converter for high power factor correction along with tight regulation is presented in this thesis. The converter offers input/output transformer isolation for safety, a unity input power factor for minimum reactive power, high efficiency and high power density for minimum weight and volume. Compared with previously developed 3-phase two-stage power converter, the advantage of the proposed converter does not require expensive high voltage and high current devices that are normally needed in popular boost type 3-phase converter. In this paper, a detailed small signal analysis of the modular 3-phase AC-DC flyback converter is provided for control purposes and also experimental results are included to confirm the validity of the analysis.

  • PDF

Analysis of Factors Affecting the Slope Stability of Uncontrolled Waste Landfill (비위생 폐기물 매립지 사면의 안정성에 관한 영향인자 분석)

  • Yoo, Han-Kyu;Choi, Bong-Hyuck
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.1
    • /
    • pp.5-12
    • /
    • 2002
  • The effects of ground water level, shear strength parameters of refuse, and geological condition of ground on the slope stability of uncontrolled waste landfill were studied. The Janbu method of slices based on the limit equilibrium method was used to calculate the minimum factor of safety with respect to slope stability of landfill. The analytical results showed that the factor of safety for a fully dried condition of landfill increased 2.4~2.8 times as great as that for a fully saturated condition of landfill. Under the condition of actual ground water level, the factor of safety linearly increased with increasing both cohesion and internal friction angle of refuse. Also, when the potential failure surface passed through the underlying layer, the factor of safety and shape of potential failure surface were found to depend on geological conditions of underlying layer.

  • PDF

A Study on Effect of Stabilizing Pile on Stability of Infinite Slope (무한사면의 안정성에 미치는 억지말뚝의 영향에 대한 이론적 연구)

  • Lee, Seung-Hyun;Lee, Su-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.496-503
    • /
    • 2016
  • To analyze an infinite slope that is reinforced with stabilizing piles, the forces on the stabilizing pile were estimated by the theory of plastic deformation and the theory of plastic flow and the effects of diverse factors on the factor of safety of an infinite slope were investigated. According to the results of the analyses, the factor of the safety of the slope reinforced with stabilized piles were increased tremendously and the factor of safety decreased as the center to center distance of the stabilizing pile increased. The effect of the existence of seepage of the infinite slope with stabilizing piles on the factor of safety appears to be insignificant. Considering the formulated factor of safety of an infinite slope with stabilizing piles, the width and length of the element of the infinite slope and force on the stabilizing pile influence the factor of safety of the infinite slope with a stabilizing pile including the soil strength parameter, inclination of the slope and depth of the slope, which are important for calculating the factor of safety of a non-reinforced infinite slope. The factor of safety of an infinite slope with stabilizing piles derived from the theory of plastic deformation were increased significantly with the internal friction angle of the soil, and the minimum and the maximum factor of safety under the conditions considered in this study were 13.7 and 65.6, respectively. As the diameter of the stabilizing pile increased, the forces on the stabilizing pile also increased but the factor of safety of the infinite slope with stabilizing piles decreased due to the effects of the width and the length of the element of the infinite slope. The factor of safety of the infinite slope with stabilizing piles derived from plastic flow were much larger than that of the non-reinforced infinite slope and the factor safety of the infinite slope with a stabilizing pile increased with increasing product of the flow velocity and plastic viscosity ( ) and the factor of safety of the infinite slope with stabilizing piles decreased with increasing center to center distance of the pile.

An Assessment of Rock Pillar Stability in Tunnel Asymmetric Diverging Area using the Mohr-Coulomb Failure Theory (Mohr-Coulomb 파괴접근도 방법을 이용한 비대칭 분기부 암반필러의 안정성 평가)

  • Lee, Choul-Kyu;Lee, Kang-Il;Kang, Jae-Gi
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.17-23
    • /
    • 2016
  • This study assessed the behavior of rock pillar in tunnel asymmetric diverging area by using a three dimensional numerical analysis. The stability of pillar is very important for the ensure the stability of the tunnel asymmetric diverging area. Based on parameters affecting the behavior of rock pillar, this study evaluated different safety factors according to pillar width, depth and rock conditions. It turned out that as the rock pillar width increases, the change curve of safety factors in accordance with depth and rock conditions shows more of the nonlinear behavior. By the assessment of the minimum safety factor, a safety factor chart on the behavior of rock pillar in tunnel asymmetric diverging area was suggested.