• 제목/요약/키워드: minimum horizontal load

검색결과 32건 처리시간 0.024초

Seismic performance of precast assembled bridge piers with hybrid connection

  • Shuang, Zou;Heisha, Wenliuhan;Yanhui, Liu;Zhipeng, Zhai;Chongbin, Zhang
    • Structural Engineering and Mechanics
    • /
    • 제85권3호
    • /
    • pp.407-417
    • /
    • 2023
  • Precast assembled bridge piers with hybrid connection (PASP) use both tendons and socket connections. To study the seismic performance of PASP, a full-scale in-situ test was performed based on an actual bridge project. The elastic-plastic fiber model of PASP was established using finite element software, and numerical analyses were performed to study the influence of prestress degree and socket depth on the PASP seismic performance. The results show that the typical failure mode of PASP under horizontal load is bending failure dominated by concrete cracking at the joint between the column and cushion cap. The cracking of the pier concrete and opening of joints depend on the prestress degree and socket depth. The prestressing tendons and socket connection can provide enough ductility, strength, restoration capability, and bending strength under small horizontal displacements. Although the bearing capacity and post yield stiffness of the pier can be improved to some extent by increasing the prestressing force, ductility is reduced, and residual deformation is increased. Overall, there are reasonable minimum socket depths to ensure the reliability of the socket connection.

ADAMS를 이용한 항공기 착륙장치 지상 충격하중 및 동적거동 해석 (An analysis on the ground impact load and dynamic behavior of the landing gear system using ADAMS)

  • 최섭;이종훈;조기대;정창래
    • 한국항공우주학회지
    • /
    • 제30권4호
    • /
    • pp.114-122
    • /
    • 2002
  • 착륙장치 시스템의 개발은 설계특성상 충격흡수 성능에 대한 설계 파라메터, 최소한의 작동공간, 복잡성 및 중량과 비용 등의 복합적인 관계를 가지고 있다. 특히 항공기 착륙에 따른 지상충격하중 및 동적거동은 착륙장치 자체 구성품 뿐만 아니라 장착구조물의 설계 하중으로 적용되는 중요한 설계분야이다. 본 연구에서는 T-50 착륙장치를 모델로 ADAMS를 이용하여 지상 충격하중 및 동적거동을 해석할 수 있는 프로그램을 개발하였다. 항공기 운용/환경조건을 고려한 충격흡수특성 해석은 다양한 설계경험을 토대로 수행하였다. 설계변수 설정, 완충기에 작용하는 내력정의, 운동방정식을 유도하여 착륙 수직속도, 착륙 자세, 착륙 수평속도, 완충효율, 장착위치 작용하중 등을 고려한 해석결과와 동적거동 특성을 분석하고 제시하였다. 이러한 해석 결과를 바탕으로 향후 새로운 착륙장치 개발시 범용적인 해석이 용이할 뿐만 아니라 지상/비행시험의 문제점 발생시 고장탐구 해결에 활용할 수 있다.

열간 압연에서 2단 사이징 프레스 금형에 의한 슬래브의 변형거동 예측 (Deformation Behavior of Slab by Two-Step Sizing Press in a Hot Strip Mill)

  • 이상호;김동환;변상민;박해두;김병민
    • 소성∙가공
    • /
    • 제14권9호통권81호
    • /
    • pp.791-797
    • /
    • 2005
  • Extensive width reduction of slabs is an important technology for achieving continuous production between the steelmaking and hot rolling processes. However, the vertical horizontal rolling process has many disadvantages, e.g., large width deviations and less efficient width reduction. This study was carried out to investigate the deformation of slab by sizing press with two steps die. To do it, dog-bone and camber are discussed in width sizing process considering the deformation behavior according to the deviation of anvil velocity and the deviation of initial slab temperature. In this paper, the various causes of the sizing press phenomena are mentioned for the purpose of understanding of rolling conditions. As a result, the optimal anvil shape having a minimum-forming load is obtained by FE-simulation and ANN.

지상용 소형 루프히트파이프 성능에 관한 연구 (Thermal Performance of a Small-scale Loop Heat Pipe for Terrestrial Application)

  • 정원복;부준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1052-1057
    • /
    • 2004
  • A small-scale loop heat pipe with polypropylene wick was fabricated and tested for its thermal performance. The container and tubing of the system was made of stainless steel and several working fluids were used to see the difference in performance including methanol, ethanol, acetone, R134a, and water. The heating area was 35 mm ${\times}$ 35 mm and there were nine axial grooves in the evaporator to provide a vapor passage. The pore size of the polypropylene wick inside the evaporator was varied from 0.5 m to 25 m. The size of condenser was 40 mm (W) ${\times}$ 50 mm (L) in which ten coolant paths were provided. The inner diameter of liquid and vapor transport lines were 2.0 mm and 4.0 mm, respectively and the length of which were 0.5 m. The PP wick LHP was operated with methanol, acetone, and ethanol normally. R134a was not compatible with PP wick and water was unsuitable within operating limit of $100^{\circ}C$. The minimum thermal load of 10 W (0.8 W/cm2) and maximum thermal load of 80 W (6.5 W/cm2) were achieved using methanol as working fluid with the condenser temperature of $20^{\circ}C$ with horizontal position.

  • PDF

3 패드 가스 포일 저널 베어링의 프리로드 증가에 따른 성능 해석 (Analysis of Three-Pad Gas Foil Journal Bearing for Increasing Mechanical Preloads)

  • 이종성;김태호
    • Tribology and Lubricants
    • /
    • 제30권1호
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, a three-pad gas foil journal bearing with a diameter of 40 mm and an axial length of 35 mm was modeled to predict the static and dynamic performances with regard to an increasing mechanical preload. The Reynolds equation for an isothermal and isoviscous ideal gas was coupled with a simple elastic foundation foil model to calculate the hydrodynamic pressure solution iteratively. In the prediction results, the journal eccentricity, journal attitude angle, and minimum film thickness decreased, but the friction torque increased with the preload. A quick comparison implied a lower load capacity but higher stability for a three-pad gas foil bearing compared to a one-pad gas foil journal bearing. The direct stiffness coefficients increased with the preload, but the cross-coupled stiffness coefficients decreased. The direct damping coefficient increased in the horizontal direction but decreased in the vertical direction as the preload increased. These model predictions will be useful as a benchmark against experimental test data.

Experimental Study on the Thermal Performance of a Small-scale Loop Heat Pipe with Polypropylene Wick

  • Boo Joon Hong;Chung Won Bok
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1052-1061
    • /
    • 2005
  • A small-scale loop heat pipe (LHP) with polypropylene wick was fabricated and tested for investigation of its thermal performance. The container and tubing of the system were made of stainless steel and several working fluids were tested including methanol, ethanol, and acetone. The heating area was $35\;mm\;{\times}\;35\;mm$ and nine axial grooves were provided in the evaporator to provide vapor passages. The pore size of the polypropylene wick inside the evaporator was varied from $0.5\; {\mu}m\;to\;25\;{\mu}m.$ The inner diameter of liquid and vapor transport lines were 2.0 mm and 4.0 mm, respectively and the length of which were 0.5 m. The size of condenser was $40\;mm\;(W)\;{\times}\;50\;mm\;(L)$ in which ten coolant paths were provided. Start-up characteristics as well as steady-state performance was analyzed and discussed. The minimum thermal load of $10\;W\;(0.8\;W\;/cm^{2})$ and maximum thermal load of $80\;W\;(6.5\;W\;/cm^{2})$ were achieved using methanol as working fluid with the condenser temperature of $20^{\circ}C$ with horizontal position.

고무코어패드와 강재이력감쇠장치를 결합한 복합감쇠장치의 이력특성에 관한 연구 (A Study on Characteristics of Hybrid Damping Device Combining Rubber Core Pad and Hysteretic Steel Slit)

  • 박병태;이준호
    • 한국공간구조학회논문집
    • /
    • 제23권1호
    • /
    • pp.45-52
    • /
    • 2023
  • This study proposes an RCS composite damping device that can achieve seismic reinforcement of existing buildings by dissipating energy by inelastic deformation. A series of experiments assessing the performances of the rubber core pad, hysteretic steel slit damping device, and hybrid RCS damping device were conducted. The results showed that the ratios of the deviations to the mean values satisfied the domestic damping-device conformity condition for the load at maximum device displacement in each direction, at the maximum force and minimum force at zero displacement, as well as the hysteresis curve area. In addition, three analysis models based on load-displacement characteristics were proposed for application to seismic reinforcement design. In addition, the validity of the three proposed models was confirmed, as they simulated the experimental results well. Meanwhile, as the shear deformation of the rubber-core pad increased, the hysteretic behavior of super-elasticity greatly increased the horizontal force of the damping device. Therefore, limiting the allowable displacement during design is deemed to be necessary.

불연속암반의 공학적 특성에 따른 원형수직구 편하중에 관한 연구 (A study on asymmetric load on circular shaft due to engineering characteristics of discontinuous rock masses)

  • 신영완;문경선;주경원
    • 한국터널지하공간학회 논문집
    • /
    • 제10권2호
    • /
    • pp.119-128
    • /
    • 2008
  • 원형수직구의 경우 지형적인 요인과 지반의 불균질성으로 인하여 등분포의 대칭하중이 작용하는 경우보다는 비대칭의 편하중이 작용하는 경우가 많을 것으로 예상된다. 지금까지 지반조건에 따른 원형수직구 벽체에 작용하는 편하중 산정을 위한 정량적인 연구는 미흡한 실정이다. 본 연구에서는 불연속암반의 불균질성을 고려한 불연속체 해석을 통하여 이방성 거동에 따른 원형수직구 벽체에 작용하는 편하중 분포특성을 분석하였다. 또한, 깊이에 따른 암반등급 및 초기응력이 편하중에 미치는 영향을 분석하였다. 검토 결과 절리특성에 따라 양호한 경암반에서는 25%이하의 편하중이 발생하는 것으로 분석되었으며, 수직구 깊이에 따른 암반등급의 영향을 검토한 결과 경암의 편하중비는 25%이하, 연암에서는 $30%{\sim}40%$로 나타났다. 또한, 풍화가 진행된 파쇄연암의 편하중비는 $40{\sim}50%$로 나타났다. 깊이 100m의 경암반에 대하여 초기응력을 나타내는 측압계수(Ko)를 변수로 한 불연속체 해석을 수행하였다. 해석 결과 측압계수가 2.0보다 작은 경우의 편하중비는 약 25%의 값을 나타내나 측압계수가 2.0보다 큰 경우에는 편하중비가 점차 증가하는 경향을 나타냈다.

  • PDF

초근접 병설터널의 필라 안정성 확보 (Pillar stability in very near-twin tunnels)

  • 김동규;고성일;이정용;이철희
    • 한국터널지하공간학회 논문집
    • /
    • 제24권6호
    • /
    • pp.699-714
    • /
    • 2022
  • 본 연구의 목적은 2개 터널의 간격이 최소 1 m이내인 초근접 병설터널이 풍화토 또는 풍화암같은 연약대를 통과하는 경우에 대해 안전하며 경제적인 필라보강방법을 제시하는데 있다. 초근접 병설터널의 필라부 보강방법 제시를 위하여 2차로 도로터널 표준단면도를 적용하였다. 필라부의 두께는 1 m로 가정하였다. 터널 통과 주변 지반 조건으로 풍화토 또는 풍화암으로 가정하였다. 필라부 안정성 평가를 위하여 4가지 보강 방법, 록볼트 보강, pre-stress 강연선 보강, 필라부 상부 수평강관 보강 + 그라우팅 보강, 수평 강관 보강 + 그라우팅 + pre-stress 강연선 보강 조건에 대하여 검토하였다. 터널 주변 지반조건이 풍화토인 경우 수평강관 보강 + 그라우팅 + pre-stress 강연선 보강 조건만 필라부에서 파괴가 발생하지 않았다. 터널 주변 지반조건이 풍화암인 경우 수평강관 보강 + 그라우팅 조건과 수평강관 보강 + 그라우팅 + pre-stress 강연선 보강 조건인 경우에서만 필라부에서 파괴가 발생하지 않았다. 수평강관 보강 + 그라우팅은 필라부 상부에 가해지는 상부하중을 지지하여 필라부 상부의 안정성을 증가시키는 역할을 수행한 것으로 판단된다.

기초지반의 지지력보강공법에 관한 연구 (Studies on the Development of Bearing Capacity Reinforcement for the Foundation of Soil)

  • 유동환;최예환;유연택
    • 한국농공학회지
    • /
    • 제30권1호
    • /
    • pp.38-49
    • /
    • 1988
  • This paper presented as follows results of laboratory model tests with various shaped footings on soil bed reinforced with the strips on the base of behaviour of soil structure according to the loads and triaxial test results reinforced with geotextiles. Their parameters studied were the effects on the bearing capacity of a footing of the first layer of reinforcement, horizontal and vertical spacing of layers, number of layers, tensile strength of reinforcement and iclination load to the vertical 1.Depending on the strip arrangement, ultimate bearing capacity values could be more improved than urreinforced soil and the failure of soil was that the soil structure was transfered from the macrospace to microspase and its arrangement, from edge to edge to face to face. 2.The reinforcement was produced the reinforcing effects due to controlling the value of factor of one and permeable reinforcement was never a barrier of drainage condition. 3.Strength ratio was decreased as a linear shape according to increment of saturation degree of soil used even though at the lower strength ratio, the value of M-factor was rot influenced on the strength ratio but impermeable reinforcement decreased the strength of bearing capacity. 4.Ultimate bearing capacity under the plane-strain condition was appeared a little larger than triaxial or the other theoretical formulars and the circular footing more effective. 5.The maximum reinforcing effects were obtained at U I B=o.5, B / B=3 and N=3, when over that limit only acting as a anchor, and same strength of fabric appeared larger reinforcing effects compared to the thinner one. 6.As the LDR increased, more and more BCR occurred and there was appeared a block action below Z / B=O.5, but over the value, decrement of BCR was shown linear relation, and no effects above one. 7.The coefficient of the inclination was shown of minimum at the three layers of fabrics, but the value of H / B related to the ultimate load was decreased as increment of inclination degree, even though over the value of 4.5 there wasn't expected to the reinforcing effects As a consequence of the effects on load inclination, the degree of inclination of 15 per cent was decreased the bearing capacity of 70 per cent but irnproved the effects of 45 per cent through the insertion of geotextile.

  • PDF