• Title/Summary/Keyword: minimum fluidization air velocity

Search Result 10, Processing Time 0.022 seconds

Effect of Pressure on Minimum Fluidization Velocity and Transition Velocity to Fast Fluidization of Oxygen Carrier for Chemical Looping Combustor (케미컬루핑 연소를 위한 산소전달입자의 최소유동화속도 및 고속유동층 전이유속에 미치는 압력의 영향)

  • KIM, JUNGHWAN;BAE, DAL-HEE;BAEK, JEOM-IN;PARK, YEONG-SEONG;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.1
    • /
    • pp.85-91
    • /
    • 2017
  • To develop a pressurized chemical looping combustor, effect of pressure on minimum fluidization velocity and transition velocity to fast fluidization was investigated in a two-interconnected pressurized fluidized bed system using oxygen carrier particle. The minimum fluidization velocity was measured by bed pressure drop measurement with variation of gas velocity. The measured minimum fluidization velocity decreased as the pressure increased. The transition velocity to fast fluidization was measured by emptying time method and decreased as the pressure increased. Gas velocity in the fuel reactor should be greater than the minimum fluidization velocity and gas velocity in the air reactor should be greater than the transition velocity to fast fluidization to ensure proper operation of two interconnected fluidized bed system.

Characteristics of Splitting Solid Amount by Friendly Environmental CFB Boiler's Particle Re-circulating Device (환경친화적 CFB 보일러 입자재순환 장치의 고체량 분배 특성)

  • Kim, You-Seok;Hwang, Jae-Dong;Choi, Yong-Joon;Moon, Kil-Ho;Shun, Do-Won;Bae, Dal-Hee
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1756-1760
    • /
    • 2004
  • Circulating Fluidized-Bed (CFB) boilers which have been operated in Korea were manufactured by the design technology of foreign leading companies. As they are not active to transfer their technology, domestic companies don't have the enough ability to design it independently yet. Doosan Heavy Industries & Construction Co. Ltd. and Korean Institute of Energy Research are trying to develop and improve the particle re-circulating device among the components of CFB boiler. Our purpose is to control the amount of particles leaving the re-circulating system by adjusting utility air and reuse the heat of circulating particles. The results of experiments with cold model system show that a fluidization state in the particle re-circulating device is very stable when the amount of utility air is supplied to its wind box with 2.29 times of minimum fluidization velocity. Also the amount of particles entering the riser don't increase linearly when the amount of utility air is supplied over 2.5 times of minimum fluidization velocity. Now we are testing its functional run with the hotstate experiment set-up.

  • PDF

Study on the Fluidized-Bed Drying Characteristics of Sawdust as a Raw-Material for Wood-Pellet Fuel

  • Lee, Hyoung-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.30-36
    • /
    • 2006
  • Wood fuel must be dried before combustion to minimize the energy loss. Sawdust of Japanese red pine was dried in a batch type fluidized-bed to investigate the drying characteristics of sawdust as a raw material for bio-fuel. The minimum fluidization air velocity was increased as particle size was increased. It took about 21 minutes and 8 minutes to dry 0.08 m-deep bed of particles with average particle size of 1.3 mm from 100% to 10% moisture content at air temperature of $20^{\circ}C$ and $50^{\circ}C$, respectively.

Study on the Fluidized Bed Drying of Grains (1) - Fluidization charcteristics of Rough Rice - (곡류의 유동층 건조에 관한 연구 (1))

  • Hur, Jong-Wha;Suh, Gil-Duk
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.3
    • /
    • pp.168-182
    • /
    • 1984
  • For the purpose of drying high moisture rough rice effectively, from the view point of pre-drying, some basic experiments of fluidized bed drying of rough rice were carried out. The minimum fluidization velocities $(U_{mf})$ for both rough rice and glass bead were analyzed to find out fluidizing characteristics. The main results obtained were as follows ; 1) Minimum fluidization velocity of rough rice and glass bead were 2.01m/s and 4.07m/s, respectively, when using the distributor with $16\%$ opening ratio. 2) $U_{mf}$ calculated by Shirai's empirical equation and that calculated by Wen's modified equation were inconsistent with experimental data, while $U_{mf}$ calculated by Ergun's equation was consistent with the experimental data. 3) The following equations, on the basis of Leva's equation, were obtained. $$C_{mf}=1.19\times10^{-4}(Re_p)^{-0.0318)\;(rough rice)$$ $$C_{mf}=1.02imes10^{-4}(Re_p)^{-0.0047)\;(glass bead)$$

  • PDF

Fluidization Study in the Fluidized Bed Drying of Naked and Husked Barley (쌀보리와 겉보리의 유동층 건조에서의 유동화 연구)

  • Kim, Hee-Yun;Hur, Jong-Hwa;Cho, Duk-Jae
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.414-422
    • /
    • 1992
  • To keep up with urgent need of continuous, effective and rapid drying unit, a fluidized bed drying system with computer controlling air temperature, velocity and relative humidity was designed. This study was attempted to determine physical properties and some basic experiments of fluidized bed d교ing of barley. Also experimental data of the designed fluidized bed drying system using the barely were compared with those of published equations to confirm the reliability of the system and the following results were obtained. The physical dimension husked barley were shown larger than that of naked barley from the experiment. When air temperature. relative humidity and charged amount were $35^{\circ}C$, 30% and 300g respectively, the minimum fluidization velocity of naked and husked barley were found 1.5 m/s and 1.7 m/s. And the optimum fluidization velocity was shown as 3.0 m/s from the experiment. The empirical equation of $U_{mf}$ in this fluidized system was obtained as follow; $U_{mf}^2= \frac{{\phi_s}\;d_p}{Hk}\;{\cdot}\;\frac{(\rho_s-\rho_g)g\;{{\varepsilon}_{mf}^3}} {\rho_g}(Re_p>1,000)$ Where HK=0.4881 for naked barley, 0.6649 for husked barley.

  • PDF

Combustion Characteristics of Waste Sewage Sludge using Oxy-fuel Circulating Fluidized Bed (슬러지 순산소 유동층 연소특성)

  • Jang, Ha-Na;Sung, Jin-Ho;Choi, Hang Seok;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.846-853
    • /
    • 2017
  • Cold bed and $30kW_{th}$ pilot bed tests using circulating fluidized bed (CFB) were conducted to apply oxy-fuel technology for waste sludge combustion as a carbon capture and storage technology. In cold bed test, the minimum fluidization velocity ($u_{mf}$) and superficial velocity for fast fluidization was determined as 0.120 m/s and 2.5 m/s, respectively. In the pilot test, air and oxy-fuel combustion experiments for waste sludge were conducted using CFB unit. The flue-gas temperature in 21~25% oxy-fuel combustion was higher than that of air and up to 30% oxy-fuel combustion. In addition, the concentration of carbon dioxide was more than 80% with the oxygen injection range from 21% to 25% in oxy-fuel CFB waste sludge combustion.

Experimental Study of Co-firing and Emission Characteristics Fueled by Sewage Sludge and Wood Pellet in Bubbling Fluidized Bed (기포 유동층 반응기를 이용한 하수슬러지 및 우드펠렛 혼소에 관한 연소 특성 분석 및 비교)

  • Lee, Youngjae;Kim, Jongmin;Kim, Donghee;Lee, Yongwoon
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.80-89
    • /
    • 2017
  • The bubbling fluidized bed (BFB) reactor with a diameter of 0.1 m and a height of 1.2 m was used for experimental study of co-firing and emission characteristics fueled by sewage sludge (SS) and wood pellet (WP). The facility consists of a fluidized bed reactor, feeding system, cyclone, condenser and gas analyzer, The mean particle diameter and minimum fluidization velocity are $460{\mu}m$ and $0.21ms^{-1}$ respectively. SS produced from Korea and WP from Canada were examined. The various mixing ratios of WP were 20, 50, and 80% based on HHV. The equivalence ratio of 1.65, reactor temperature of $800^{\circ}C$, air flow rate of $100Lmin^{-1}$, and fluidization number of 4 were fixed in the BFB experiment. In TGA, the range of combustion temperature of SS was wider than that of WP. It represents that the combustibility of WP is higher than that of SS. The BFB reactor temperature was maintained between 800 and $900^{\circ}C$. CO emission of SS was high because of lower combustibility. $NO_X$ and $SO_X$ formation of SS were higher than that of WP since high nitrogen and sulfur contents of SS. CO, $NO_X$, and $SO_X$ formation were suppressed as the mixing ratio of WP was increased. The slagging and fouling tendencies show high in all test conditions.

Flow Behavior and Mixing Characteristics of Rice Husk/Silica Sand/Rice Husk Ash (왕겨/모래/왕겨 회재의 유동 및 혼합 특성 연구)

  • Kim, Bo Hwa;Seo, Myung Won;Kook, Jin Woo;Choi, Hee Mang;Ra, Ho Won;Yoon, Sang Jun;Mun, Tae Young;Kim, Yong Ku;Lee, Jae Goo;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.533-542
    • /
    • 2016
  • We investigate fluidization characteristics of the mixture of rice husk, silica sand and rice husk ash as a preliminary study for valuable utilization of rice husk ash obtained from gasification of rice husk in a fluidized bed reactor. As experiment valuables, the blending ratio of rice husk and sand (rice husk: sand) is selected as 5:95, 10:90, 20:80 and 30:70 on a volume base. Rice husk ash was added with 6 vol% of rice husk for each experiment and air velocity to the reactor was 0~0.63 m/s. In both rice husk/sand and rice husk/sand/ash mixture, the minimum fluidization velocity (Umf) is observed as 0.19~0.21 m/s at feeding of 0~10 vol.% of rice husk and 0.30 m/s at feeding of 20 vol.% of rice husk. With increasing the amount of rice husk up to 30 vol.%, $U_{mf}$ can not measure due to segregation behavior. The mixing index for each experiment is determined using mixing index equation proposed by Brereton and Grace. The mixing index of the mixture of rice husk/sand and rice husk/sand/ash was 0.8~1 and 0.88~1, respectively. The optimum fluidization condition was found for the good mixing and separation of rice husk ash.

Conceptual Design and Hydrodynamic Properties of a Moving Bed Reactor for Intrinsic $CO_2$ Separation Hydrogen Production Process ($CO_2$ 원천분리 수소 제조 공정을 위한 이동층 반응기의 개념 설계 및 수력학적 특성)

  • Park, Dong-Kyoo;Cho, Won-Chul;Seo, Myung-Won;Go, Kang-Seok;Kim, Sang-Done;Kang, Kyoung-Soo;Park, Chu-Sik
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.69-77
    • /
    • 2011
  • The intrinsic $CO_2$ separation and hydrogen production system is a novel concept using oxidation and reduction reactions of oxygen carrier for both $CO_2$ capture and high purity hydrogen production. The process consists of a fuel reactor (FR), a steam reactor (SR) and an air reactor (AR). The natural gas ($CH_4$) is oxidized to $CO_2$ and steam by the oxygen carrier in FR, whereas the steam is reduced to hydrogen by oxidation of the reduced oxygen carrier in SR. The oxygen carrier is fully oxidized by air in AR. In the present study, the chemical looping moving bed reactor having 200 L/h hydrogen production capacity is designed and the hydrodynamic properties were determined. Compared with other reactors, two moving bed reactors (FR, SR) were used to obtain high conversion and selectivity of the oxygen carrier. The desirable solid circulation rates are calculated to be in the range of $20{\sim}100kg/m^2s$ from the conceptual design. The solid circulation rate can be controlled by aeration in a loop-seal. To maintain the gas velocity in the moving beds (FR, SR) at the minimum fluidization velocity is found to be suitable for the stable operation. The solid holdup in moving beds decrease with increasing gas velocity and solid circulation rate.

A Study on the Effect of Fluidizing Media on the N2O Production in Fluidized Bed Incineration of Sewage Sludge (하수슬러지 유동층 소각에서 유동매체가 N2O 발생에 미치는 영향에 관한 연구)

  • Park, Jong-Ju;Lee, Seung-Jae;Ryu, In-Soo;Jeon, Sang Goo;Park, Yeong-Sung;Moon, Seung-Hyun
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.390-397
    • /
    • 2014
  • This study was performed to investigate the effects of fluidizing media on $N_2O$ production in fluidized bed incineration of sewage sludge. The fluidized media were prepared in a form of 2 mm bead by mixing zeolite powders in our lab. Sand having 0.4 mm of the mean size showed 0.44 m/s of minimum fluidization velocity ($U_{mf}$), while the prepared zeolite media 0.5 m/s. When the ratio of fluidizing media height to the inside diameter of the incinerator (bed aspect ratio) increased from 1.4 to 3.1, it was found that $U_{mf}$ of the zeolite media was varied from 0.5 m/s to 0.7 m/s. Under the operation conditions in 1.79 of excess air ratio, $909^{\circ}C$ of bed temperature and ca. 1.65 m/s of superficial velocity, as the weight of fluidizing meadia was increased, $O_2$ concentration in the flue gas was slightly decreased, and $CO_2$ increased. Above 6 kg of fluidizing media weight (1.98 of bed aspect ratio), it was observed that $N_2O$ concentration was significantly reduced, which might result from the decomposition of $N_2O$ on the zeolite media rather than transformation of $N_2O$ to NOx. On the other hand, in a variation of the zeolite media mixing ratio to sand and bed temperature at a constant total bed height, significant difference was exhibited in $N_2O$ emission concentration according to the temperature. Considering the operation temperature in the incineration, the effective calcination temperature of the zeolite media was suggested to be around $900^{\circ}C$.