• 제목/요약/키워드: minimal surface

검색결과 419건 처리시간 0.026초

Antibacterial Activity of CNT-Ag and GO-Ag Nanocomposites Against Gram-negative and Gram-positive Bacteria

  • Yun, Hyosuk;Kim, Ji Dang;Choi, Hyun Chul;Lee, Chul Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3261-3264
    • /
    • 2013
  • Carbon nanocomposites composed of carbon nanostructures and metal nanoparticles have become one of useful materials for various applications. Here we present the preparation and antibacterial activity of CNT-Ag and GO-Ag nanocomposites. Their physical properties were characterized by TEM, XPS, and Raman measurements, revealing that size-similar and quasi-spherical Ag nanoparticles were anchored to the surface of the CNT and GO. The antibacterial activities of CNT-Ag and GO-Ag were investigated using the growth curve method and minimal inhibitory concentrations against Gram-negative and Gram-positive bacteria. The antibacterial activities of the carbon nanocomposites were slightly different against Gram-positive and Gram-negative bacteria. The proposed mechanism was discussed.

차세대전동차의 실내온열환경 연구 (Study on Indoor Thermal Comfort of Advanced EMU)

  • 권순박;박덕신;조영민;박성혁;오세찬;김영남
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1799-1802
    • /
    • 2008
  • More than 7 million people use the Seoul metropolitan subway network daily. This number tends to increase due to the increase of oil price. Indoor air quality of electrical multiple unit (EMU) is strongly affected by outdoor air quality, however, indoor thermal comfort is subjected to heating, ventilating, and air conditioning (HVAC) system of EMU. In general, air temperature, humidity, air velocity, surface temperature, and illumination are key parameters affecting thermal comfort of passenger. It is known that the well-designed HVAC system should improve the thermal comfort of passengers and should increase the energy efficiency of HVAC system also. In this study, we analyzed the thermal comfort of advanced EMU developed by Korea Railroad Research Institute by using the computational fluid dynamics (CFD) in order to find the optimum HVAC system which can improve thermal comfort of passengers with a minimal energy use.

  • PDF

ON TRANSLATION LENGTHS OF PSEUDO-ANOSOV MAPS ON THE CURVE GRAPH

  • Hyungryul Baik;Changsub Kim
    • 대한수학회보
    • /
    • 제61권3호
    • /
    • pp.585-595
    • /
    • 2024
  • We show that a pseudo-Anosov map constructed as a product of the large power of Dehn twists of two filling curves always has a geodesic axis on the curve graph of the surface. We also obtain estimates of the stable translation length of a pseudo-Anosov map, when two filling curves are replaced by multicurves. Three main applications of our theorem are the following: (a) determining which word realizes the minimal translation length on the curve graph within a specific class of words, (b) giving a new class of pseudo-Anosov maps optimizing the ratio of stable translation lengths on the curve graph to that on Teichmüller space, (c) giving a partial answer of how much power is needed for Dehn twists to generate right-angled Artin subgroup of the mapping class group.

6MV 선형가속기에서 Al/Cu에 관한 여과판 사용시 전자오염 감소에 관한 연구 (Reduction of Electron Contamination in Photon Beam by electron Filter in 6MV Linear Accelerator)

  • 이철수
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.41-54
    • /
    • 1996
  • The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.

  • PDF

A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

  • Park Chan-Jin;Kim Yung-Soo;Kim Chang-Whe;Cho Lee-Ra;Yi Yang-Jin
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.271-287
    • /
    • 2003
  • Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

태양복사모델(SOLWEIG)의 복사플럭스 자료를 활용한 노면온도 예측: 서울시 내부순환로 대상 (Predicting Road Surface Temperature using Solar Radiation Data from SOLWEIG(SOlar and LongWave Environmental Irradiance Geometry-model): Focused on Naebu Expressway in Seoul)

  • 안숙희;권혁기;양호진;이근희;이채연
    • 한국지리정보학회지
    • /
    • 제23권4호
    • /
    • pp.156-172
    • /
    • 2020
  • 본 연구는 대상도로인 내부순환로에 대해 태양복사모델(SOlar and LongWave Environmental Irradiance Geometry-model, SOLWEIG)을 통해 산출한 도로의 그림자 패턴을 사용하여 항상 그늘이 지는 음영지역을 살펴보고, 열수지법을 기반으로 한 노면온도예측모델(road surface temperature prediction model, 이하 RSTPM)과 SOLWEIG 모델을 연계하여 고해상도의 태양복사정보를 활용한 도로의 노면온도를 예측하고자 하였다. 우선, 그림자 패턴 및 복사플럭스 산출의 정확도를 높이기 위하여 안개, 구름, 강수 등의 영향을 최소화할 수 있는 사례일을 선정하여, 고도 및 지형의 효과에 따른 그림자의 영향을 살펴보았다. 그 결과, 터널 입출구와 고도가 높은 지역에서 그림자 영역이 오래 지속되었고, 그림자의 영향을 많이 받는 구간의 복사량 감소가 뚜렷하게 나타났다. 이는 노면온도 예측결과에 반영되어 지형적으로 개방된 지점에서는 노면온도가 높게 예측되고, 고도가 높은 지점들은 그렇지 않은 지점에 비해 상대적으로 낮게 예측되었다. 본 연구의 결과는 겨울철 기상상황에 따른 도로 결빙구간을 예측하여 도로 관리자 및 운전자의 의사결정 자료로서의 활용이 기대된다.

최소가공채소류에 적합한 갈변방지제의 선발 (Screening of Antibrowning Agents for Minimally Processed Vegetables)

  • 박우포;조성환;이동선
    • 한국식품과학회지
    • /
    • 제30권2호
    • /
    • pp.278-282
    • /
    • 1998
  • 편의성과 신선함을 동시에 추구하는 최소가공채소류의 저장 유통중에 품질을 저하시키는 요인중의 하나인 갈변을 억제할 수 있는 적절한 갈변방지제를 선발하기 위하여 ascorbic acid, citric acid 및 allyl isothiocynate (AITC)의 농도를 달리하여 깐마늘, 콩나물, 절단 양파 및 절단 풋고추에 처리하여 저장하면서 이들의 효과를 검토한 결과는 다음과 같았다. 즉 깐마늘은 citric acid 1%, 콩나물은 ascorbic acid 1%, 양파는 citric acid 2%, 풋고추는 ascorbic acid 1% 처리시에 색차가 비교적 낮게 나타나 갈변 억제에 효과가 있는 것으로 나타났다. AITC는 마늘에 있어서 저장 10일까지는 갈변 억제의 효과가 있었으나 다른 품목에 있어서는 오히려 갈변을 촉진하는 것으로 나타났다. 깐마늘은 저장 기간이 경과함에 따라서 시료 표면의 갈변 정도와 polyphenol oxidase의 역가가 증가하였으나 절단 풋고추는 갈변 정도가 커짐에 따라 효소의 역가가 오히려 감소하는 것으로 나타났다.

  • PDF

거골 골절에서 체중 부하 관절면의 중요성 (Impact of Weight Bearing Surface on Fractures of the Talus)

  • 정현욱;유시훈;서진수
    • 대한족부족관절학회지
    • /
    • 제13권2호
    • /
    • pp.156-161
    • /
    • 2009
  • Purpose: The fracture of talus has critical complications and results in various clinical outcomes. The purpose of this study is to evaluate clinical outcome and influence on involvement of ankle and subtalar joint. Materials and Methods: From December 1999 to December 2008, a total of 66 fractures and dislocations of talus was treated with minimal 9 months follow up period. Ankle-hindfoot scale of the American Orthopedic Foot & Ankle Society (AOFAS) was used to evaluate the clinical outcome. The complications and sequential radiologic findings were also analyzed. Results: There were 28 neck fractures, 11 lateral process fractures, 10 body fractures, 7 osteochondral fractures, 4 posteromedial tubercle fractures and 4 medial process fractures. In 38 cases, there were concomitant injuries. Ipsilateral ankle fracture, which found in 19 cases, was most common. The surgical treatment was performed in 36 cases. Mean AOFAS score was 85.5 (range, 72 to 96). In 13 of 47 cases, one or more fracture lines involving weight bearing surface were confirmed. The involvement of ankle or subtalar joint had resulted in unsatisfied outcome. Complications were developed as follows, post-traumatic arthritis in 8 cases, avascular necrosis in 3 cases, and deep infection in 2 cases. Conclusion: The involvement of ankle or subtalar joint in fractures of talus seemed to be common and to impact the clinical outcome. Meticulous consideration about that will be positively necessary.

  • PDF

항균제를 이용한 알루미늄 표면에 생물막 형성 억제효과 분석 (Study of Effectiveness of Antimicrobial on Restraining Formation of Biofilms on the Surface of Aluminum)

  • 박상준;오영환;조보연;최미연;현민우;정재현;김의용
    • KSBB Journal
    • /
    • 제30권2호
    • /
    • pp.69-76
    • /
    • 2015
  • The antibacterial activity of a antimicrobial (organic synthetic or organic natural material) on the bacteria (Bacillus megaterium, Arthrobacter oxydans, Micrococcus luteus, Methylobacterium aquaticum) detected in the automobiles showed 99.9% bacteria decrease rate within 30 min of being in contact with the tested bacteria culture. The MIC of the organic synthetic material based antimicrobials and the organic natural material based antimicrobial on the bacteria were 31~500 mg/mL and 8~250 mg/mL, respectively. The bacteria and biofilms were formed on the surface of aluminum after 5 ~8 days in the case of addition of the organic synthetic material based antimicrobial to the MIC values for the tested bacteria culture. On the other hand, there was no proliferation of bacteria and formation of biofilms on the surface of aluminum even after 30 days in the case of addition of the organic natural material based antimicrobial to the MIC values for the tested bacteria culture. As a result, the organic natural material based antimicrobial was confirmed to be more excellent effect of inhibition of bacterial proliferation and restraint of biofilms formation than the organic synthetic material based antimicrobial.

개질된 Nanoscale Zero-Valent Iron을 이용한 질산성질소 처리 (Removal of Nitrate by modified Nanoscale Zero-Valent Iron)

  • 김홍석;안준영;황경엽;박주양;황인성
    • 상하수도학회지
    • /
    • 제23권4호
    • /
    • pp.471-479
    • /
    • 2009
  • A Nanoscale Zero-Valent Iron(NZVI) was modified to build a reactor system to treat nitrate. Shell layer of the NZVI was modified by slow exposure of the iron surface to air flow, which produced NZVI particles that are resistant to aerial oxidation. A XANES (X-ray Absorption Near-Edge Structure) analysis revealed that the shell consists of magnetite ($Fe_3O_4$) dominantly. The shell-modified NZVI(0.5 g NZVI/ 120 mL) was able to degrade more than 95% of 30 mg/L of nitrate within $30 hr^{-1}$ ( pseudo first-order rate constant($k_{SA}$) normalzed to NZVI surface area ($17.96m^2/g$) : $0.0050L{\cdot}m^{-2}{\cdot}hr^{-1}$). Ammonia occupied about 90% of degradation products of nitrate. Nitrate degradation efficiencies increased with the increase of NZVI dose generally. Initial pH values of the reactor systems at 4, 7, and 10 did not affect nitrate removal rate and final pH values of all experiments were near 12. Nitrate removal experiments by using the shell-modified NZVI immobilized on a cellulose acetate (CA) membrane were also conducted. The nitrate removal efficiency of the CA membrane supported NZVI ($k_{SA}=0.0036L{\cdot}m^{-2}{\cdot}hr^{-1}$) was less than that of the NZVI slurries($k_{SA}=0.0050L{\cdot}m^{-2}{\cdot}hr^{-1}$), which is probably due to less surface area available for reduction and to kinetic retardation by nitrate transport through the CA membrane. The detachment of the NZVI from the CA membrane was minimal and impregnation of up to 1 g of NZVI onto 1 g of the CA membrane was found feasible.