• Title/Summary/Keyword: minimal model

Search Result 653, Processing Time 0.026 seconds

Immuno-chromatographic Analysis for HPV-16 and 18 E7 Proteins as a Biomarker of Cervical Cancer Caused by Human Papillomavirus

  • Kim, Joo-Ho;Cho, Il-Hoon;Seo, Sung-Min;Kim, Ji-Sook;Oh, Kyu-Ha;Kang, Heun-Soo;Kim, In-Gyu;Paek, Se-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.2999-3005
    • /
    • 2009
  • Among the more than 120 different types of human papillomavirus (HPV), types 16 and 18 have been known to be high risk agents that cause cervical cancer. We examined, in an immuno-chromatographic analysis, the potential of using the early gene product, E7 protein, as a diagnostic marker of cervical cancer caused by HPV. We developed monoclonal antibodies specific to HPV-16 and 18 E7 proteins that were produced from bacterial cells using gene recombinant technology. For each E7 protein, the optimal antibody pair was selected using the immuno-chromatographic sandwichtype binding system based on the lateral flow through membrane pores. Under these conditions, this rapid testing assay had a detection capability as low as 2 ng/mL of E7 protein. Furthermore, since viral analysis required the host cell to be lysed using chemicals such as detergents, it was possible that the E7 protein was structurally damaged during this process, which would result in a decrease in detection sensitivity. Therefore, we examined the detrimental effects caused by different detergents on the E7 protein using HeLa cells as the host. In these experiments, we found that the damage caused by the detergent, nonylphenylpolyethylene glycol (NP-40), was minimal relative to Triton X-100 commonly used for the cell lysis. Temperature also affected the stability of the E7 protein, and we found that the E7 protein was stabilized at 4$^{\circ}C$ for about 2 h, which was 4 times longer than at room temperature. Finally, a HPV-infected cervical cancer cell line, which was used as a real sample model, was treated using the optimized conditions and the presence of E7 proteins were analyzed by immuno-chromatography. The results of this experiment demonstrated that this rapid test could specifically detect HPV-infected samples.

THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS (치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 -)

  • Lee Yong-Keun;Lee Keon-Il;Jung Sung-Woo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

Optimal Design of Overlapped Ultrasonic Sensor Ring for High Performance Obstacle Detection Using Effective Beam Overlap (효과적인 빔 폭 중첩을 이용한 고성능 장애물 탐지용 중첩 초음파 센서 링의 최적 설계)

  • Kim, Sung-Bok;Kim, Hyun-Bin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.1
    • /
    • pp.67-75
    • /
    • 2011
  • This paper presents the systematic optimal design of an overlapped ultrasonic sensor ring for high performance obstacle detection using effective beam overlap. Basically, a set of low directivity ultrasonic sensors of the same type are arranged in a circle at regular intervals with their beams overlapped. First, both real and simplified beam patterns of an ultrasonic sensor and several sensor models for obstacle position estimation within its beam pattern are introduced. Second, the obstacle detection range of an overlapped ultrasonic sensor ring and its simple sensor model for obstacle position estimation are described. Third, for both conic and non-conic shaped beam pattern, the design indices of an overlapped ultrasonic sensor ring for minimal positional uncertainty in obstacle detection are defined. Fourth, the constraints imposed on the structural parameters of an overlapped ultrasonic sensor ring to guarantee non empty beam overlap and to avoid excessive beam overlap are derived. Fifth, the optimal number of ultrasonic sensors for a given radius of an overlapped ultrasonic sensor ring and the optimal radius of an overlapped ultrasonic sensor ring are determined. Throughout this paper, the MA40B8 from Murata Inc. is taken as a representative commercial low directivity ultrasonic sensor.

Characteristics of Heavy Metal Biosorption by Enterobacter intermedious KH410 (Enterobacter intermedious KH410의 중금속 흡착 특성)

  • 김영희;정영기;김광현;김병우;정경태;김병석;박지원;이동준;신현철
    • Journal of Life Science
    • /
    • v.13 no.4
    • /
    • pp.421-427
    • /
    • 2003
  • A natural habit at bacterium, Enterobacter intermedious KH410 was isolated from freshwater plant root and identified. Adsorption of heavy metals such as lead, cadmium, and copper by this strain was examined. The minimal inhibitory concentrations(MIC) for each metal were 1.78 mM for lead, 0.17 mM for cadmium and 1.39 mM for lopper, respectively. Maximum production of dried cell was 2.56 g/$\ell$ in LB medium containing 0.5% NaCl, 1% yeast extract and 1% of lactose. Optimal conditions for adsorption were 0.6 dry g-biomass, at pH 4.0 and the temperature of $20^{\circ}C$. Adsorption equilibrium reached maximum after 30 min in 400 mg/$\ell$ metal solution. The adsorption capacity (K) of copper was 1.5 times higher than that of cadmium and lead was 1.1 times higher than that of cadmium. from the results obtained in this study, Freundlich adsorption model was applicable for all metals. Adsorption strength (1/n) of heavy metal ions were in the order of cadmium>copper>lead. The adsorption of dried cell for lead, cadmium, and copper was 56.2, 58.0, 55.8 mg/g-biomass, respectively. Pretreatment to increase ion strength was the most effective with 0.1 M NaOH whereas slight difference was found both KOH and $CaCl_2$ upon same concentration. Effective desorption was induced by 0.1 M EDTA for lead and 0.1 M $HNO_2$ for cadmium and copper.

Study on the Efficient Application of Vision-Based Displacement Measurements for the Cable Tension Estimation of Cable-Stayed Bridges (사장교 케이블의 장력 추정을 위한 영상변위 측정법의 효율적 적용에 대한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.709-717
    • /
    • 2016
  • In this study, the convenience and efficiency of vision-based displacement measurement (VBDM) to estimate the cable tension of cable-stayed bridges and the requirements for its effective application were examined. To demonstrate its convenience and efficiency, it was confirmed that VBDM can be accomplished with a minimum amount of equipment using a commercial camcorder. In this case, it was found that the accuracy of estimation of the natural frequencies is sufficient, even though magnitude errors can occur when conducting high-speed recording at the low resolution afforded by the minimal equipment employed. It was also confirmed that the most important factor in detecting the precise natural frequencies is the use of the appropriate frequency range in the tension estimation using vibration. Based on these results, a study was carried out on the accuracy variation of the estimated tension according to the frame rate of a commercial camcorder. For this purpose, an experiment was performed to estimate the cable tension in a cable-stayed bridge model. Through this experiment, the detectable tensions of cables with various natural frequencies as a function of the frame rate were summarized. As a result, it was shown that the frame rate should be determined based on the natural frequency which is estimated to be located within the appropriate frequency range (approximately 10~75% of theoretical range) considering the aliasing and low-frequency distortion due to excitations.

Designing optimized food intake patterns for Korean adults using linear programming (I): analysis of data from the 2010~2014 Korea National Health and Nutrition Examination Survey (선형계획법을 이용한 한국 성인의 최적 식품섭취패턴 설계 (I) : 2010~ 2014년 국민건강영양조사 자료 분석)

  • Asano, Kana;Yang, Hongsuk;Lee, Youngmi;Yoon, Jihyun
    • Journal of Nutrition and Health
    • /
    • v.51 no.1
    • /
    • pp.73-86
    • /
    • 2018
  • Purpose: The aim of this study was to design optimized food intake patterns that meet the nutritional recommendations with minimal changes from the current food intake patterns among Korean adults using linear programming. Methods: Data of a one day 24-hour dietary recall from the 2010 ~ 2014 Korea National Health and Nutrition Survey were used to quantify the food items that Korean adults usually consumed. These food items were categorized into seven groups and 24 subgroups. The mean intakes and intake distributions of the food groups and the food subgroups were calculated for eight age (19 ~ 29, 30 ~ 49, 50 ~ 64, and over 65 years old) and gender (male and female) groups. A linear programming model was constructed to minimize the difference between the optimized and mean intakes of the food subgroups while meeting the Dietary Reference Intakes for Koreans (KDRIs) for energy and 13 nutrients, and not exceeding the typical quantities of each food subgroup consumed by the respective age and gender groups. Results: The optimized food intake patterns, which were a set of quantities of 24 food subgroups, were obtained mathematically for eight age and gender groups. Overall, major modifications of current diet were required to increase the intake of vegetables and milk/dairy products and decrease the Kimchi intake. The optimized intake of seasonings, including salt, was calculated to be 0 g for all the age and gender groups. Conclusion: The optimized food intake patterns designed using linear programming in this study lack feasibility because they suggest a seasoning consumption of 0 g. Modification of intake goal for sodium is needed to obtain optimized food intake patterns with improved feasibility.

Remifentanil Protects Human Keratinocyte Through Autophagic Expression

  • Kim, Eok Nyun;Park, Chang Hoon;Woo, Mi Na;Yoon, Ji Young;Park, Bong Soo;Kim, Yong Ho;Kim, Cheul Hong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.2
    • /
    • pp.101-106
    • /
    • 2014
  • Background: Remifentanil, an ultra-short-acting mu-opioid receptor agonist, is unique from other opioids because of its esterase-based metabolism, minimal accumulation, and very rapid onset and offset of clinical action. Remifentanil can prevent the inflammatory response and can suppress inducible nitric oxide synthase expression in a septic mouse model. However, the effects of remifentanil on human keratinocyte and autophagy have yet to be fully elucidated during hypoxia-reoxygenation. Here we investigated whether remifentanil confers protective effect against hypoxia-reoxygenation in human keratinocyte and, if so, whether autophagy mediates this effect. Methods: The human keratinocytes were cultured under 1% oxygen tension. The cells were gassed with 94% $N_2$, and 5% $CO_2$ and incubated for 24 h at $37^{\circ}C$. To determine whether the administration of affects human keratinocytes hypoxia-reoxygenation injury, cells were then exposed to various concentrations of remifentanil (0.01, 0.1, 0.5 and 1 ng/ml) for 2 h. After remifentanil treatment, to simulate reoxygenation and recovery, the cells were reoxygenated for 12 h at $37^{\circ}C$. Control group did not receive remifentanil treatment. Normoxia group did not receive hypoxia and remifentanil treatment for 36 h. 3-MA group was treated 3-methyladenine (3-MA) for 1h before remifentanil treatment. Cell viability was measured using a quantitative colorimetric assay with MTT, showing the mitochondrial activity of living cells. Cells were stained with fluorescence and analyzed with Western blot analysis to find out any relations with activation of autophagy. Results: Prominent accumulation of autophagic specific staining MDC was observed around the nuclei in RPT group HaCaT cells. Similarly, AO staining, red fluorescent spots appeared in RPT group HaCaT cells, while the Normoxia, control and 3-MA groups showed mainly green cytoplasmic fluorescence. We here examined activation of autophagy related protein under H/R-induced cells by Western blotting analysis. Atg5, Beclin-1, LC3-II (microtubule-associated protein 1 light chain 3 form II) and p62 was elevated in RPT group cells. But they were decreased when autophagy was suppressed by 3-MA (Fig. 5). Conclusions: Although the findings of this study are limited to an in vitro interpretation, we suggest that remifentanil may have a beneficial effect in the recovery of wound from hypoxia-reoxygenation injury.

Development and Application of a Path-Based Trip Assignment Model under Toll Imposition (통행료체계에서의 경로기반 통행배정모형 개발과 적용에 관한 연구)

  • 권용석
    • Proceedings of the KOR-KST Conference
    • /
    • 2000.02a
    • /
    • pp.3-22
    • /
    • 2000
  • 이용자의 경로선택 형태를 모사하는 통행배정모형 결과의 정확도는 교통계획에 상당한 영향을 미친다. 이용자의 경로선택 결정과정에서 가장 중요한 판단기준은 통행시간과 통행요금이다. 그런데 통행요금은 이용자의 경로거리에 따라 다양한 방식으로 부과되므로, 링크를 분석단위로 하는 기존의 통행배정모형은 현실적인 통행요금 반영이 힘들었고 또한 수요예측 결과를 이용한 다양한 분석에서 제약을 받아 왔다. 본 연구는 이러한 배경에서 경로교통량을 도출할 수 있는 경로기반 통행배정모형을 구축하였고, 또한 경로거리에 따라 결정되는 현실적인 통행요금을 반영할 수 있는 알고리즘을 개발하였다. 경로기반 배정모형에서는 GP(Gradient Projection) 알고리즘을 이용하였고, 계산상의 효율성 제고를 위해 K-최단경로 알고리즘 중 MPS(Minimal Path Search) 알고리즘을 이용하였다. 개발된 배정 모형은 현실적인 통행요금을 반영할 수 있으므로 통행배정 결과의 정밀도를 향상시켰을 뿐만 아니라 기존 배정모형에 비해 최적해로의 수렴속도도 개선되는 것으로 나타났다. 본 논문의 배정모형은 경로교통량이 도출되고 통행요금을 반영할 수 있으므로, 통행요금과 통행 거리 관계에 따른 목적함수의 규명과 그에 따른 효과척도를 계량화할 수 있다. 따라서 본 모형은 통행배정에서 실재상황을 보다 현실여건에 맞도록 규명할 수 있고, 기존의 제한적인 효과분석의 문제점을 해결할 수 있으므로 그 활용범위가 넓다. 또한 본 논문은 개발된 배정모형의 적용사례로서 고속도로 수요관리 요금체계 개선방안을 제시하였다. 기존의 고속도로 통행요금 산정 방법은 이론적 근거가 미약했던 반면, 본 논문에서 개발된 배정모형과 고속도로 수요관리 요금체계 개선방안은 고속도로 통행료 결정에 대한 과학적이고 합리적인 분석방법을 제공하였다.한 민감도 분석을 실시한 결과 대안1의 경우 교통량의 변화 및 화물통행의 시간가치의 증가시 사회적 편익이 오히려 감소하였고, 대안2와 3의 경우 사회적 편익이 증가하는 것을 알 수 있었다. 이는 경부고속도로의 화물차량의 구성비에 따라 대안 1의 경우 오히려 화물차의 통행시간이 증가함에 그 원인이 있다 할 것이다. 이상과 같은 결론을 통하여 경부고속도로상의 화물전용차선의 설치시는 수답렬 교통량의 구성비와 구간 평균교통량에 의하여 그 효과가 다르게 나타남을 알 수 있었다. 따라서 물류비용 절감차원에서의 화물전용차선의 설치는 본 연구에서 나타낸 방법과 같이 수단간의 경제적 편익을 고려한 구간별 시간대별 효과분석을 통하여 정책의 시행여부가 결정되어야 할 것이다. 한편, 화물전용차선의 설치로 인한 물류비용의 절감을 보다 효과적으로 달성하기 위해서는 종합류류 전산망의 시급한 구축과 함께 화물차의 적재율을 높이고 공차율을 낮출 수 있는 운송체계의 수립이 필요한 것으로 판단된다. 그라나 이러한 화물전용차선의 효과는 단기적인 치유책일 수밖에 없기 때문에 물류유통 시설의 확충을 위한 사회간접자본의 구축을 서둘러 시행하여야 할 것이다.으로 처리한 Machine oil, Phenthoate EC 및 Trichlorfon WP는 비교적 약효가 낮았다.>$^{\circ}$E/$\leq$30$^{\circ}$NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군으로 추정된다. 이러한 사실은 3개 시추공을 대상으로 실시한 시추공 내 물리검층과 정압주입시험에서도 확인된다.. It was resulted from increase of weight of single cocoon. "Manta"2.5ppm produced 22.2kg of co

  • PDF

Statistical Analysis of Receding Horizon Particle Swarm Optimization for Multi-Robot Formation Control (다개체 로봇 편대 제어를 위한 이동 구간 입자 군집 최적화 알고리즘의 통계적 성능 분석)

  • Lee, Seung-Mok
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.5
    • /
    • pp.115-120
    • /
    • 2019
  • In this paper, we present the results of the performance statistical analysis of the multi-robot formation control based on receding horizon particle swarm optimization (RHPSO). The formation control problem of multi-robot system can be defined as a constrained nonlinear optimization problem when considering collision avoidance between robots. In general, the constrained nonlinear optimization problem has a problem that it takes a long time to find the optimal solution. The RHPSO algorithm was proposed to quickly find a suboptimal solution to the optimization problem of multi-robot formation control. The computational complexity of the RHPSO increases as the number of candidate solutions and generations increases. Therefore, it is important to find a suboptimal solution that can be used for real-time control with minimal candidate solutions and generations. In this paper, we compared the formation error according to the number of candidate solutions and the number of generations. Through numerical simulations under various conditions, the results are analyzed statistically and the minimum number of candidate solutions and the minimum number of generations of the RHPSO algorithm are derived within the allowable control error.

Optimal Design of Stiffness of Torsion Spring Hinge Considering the Deployment Performance of Large Scale SAR Antenna (전개성능을 고려한 대형 전개형 SAR 안테나의 회전스프링 힌지의 강성 최적설계)

  • Kim, Dong-Yeon;Lim, Jae Hyuk;Jang, Tae-Seong;Cha, Won Ho;Lee, So-Jeong;Oh, Hyun-Ung;Kim, Kyung-Won
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.3
    • /
    • pp.78-86
    • /
    • 2019
  • This paper describes the stiffness optimization of the torsion spring hinge of the large SAR antenna considering the deployment performance. A large SAR antenna is folded in a launch environment and then unfolded when performing a mission in orbit. Under these conditions, it is very important to find the proper stiffness of the torsion spring hinge so that the antenna panels can be deployed with minimal impact in a given time. If the torsion spring stiffness is high, a large impact load at the time of full deployment damages the structure. If it is weak, it cannot guarantee full deployment due to the deployment resistance. A multi-body dynamics analysis model was developed to solve this problem using RecurDyn and the development performance were predicted in terms of: development time, latching force, and torque margin through deployment analysis. In order to find the optimum torsion spring stiffness, the deployment performance was approximated by the response surface method (RSM) and the optimal design was performed to derive the appropriate stiffness value of the rotating springs.