• Title/Summary/Keyword: miniature society

Search Result 571, Processing Time 0.022 seconds

Numerical Investigation of Micro Thermal Imprint Process of Glassy Polymer near the Glass Transition Temperature (열방식 마이크로 임프린트 공정을 위한 고분자 재료의 수치적 모델링과 해석)

  • Lan, Shuhuai;Lee, Soo-Hun;Lee, Hye-Jin;Song, Jung-Han;Sung, Yeon-Wook;Kim, Moo-Jong;Lee, Moon-G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.45-52
    • /
    • 2009
  • The research on miniature devices based on non-silicon materials, in particular polymeric materials has been attracting more and more attention in the research field of the micro/nano fabrication in recent years. Lost of applications and many literatures have been reported. However, the study on the micro thermal imprint process of glassy polymer is still not systematic and inadequate. The aim of this research I to obtain a numerical material model for an amorphous glassy polymer, polycarbonate (PC), which can be used in finite element analysis (FEA) of the micro thermal imprint process near the glass transition temperature (Tg). An understanding of the deformation behavior of the PC specimens was acquired by performing tensile stress relaxation tests. The viscoelastic material model based on generalized Maxwell model was introduced for the material near Tg to establish the FE model based on the commercial FEA code ABAQUS/Standard with a suitable set of parameters obtained for this material model form the test data. As a result, the feasibility of the established viscoelastic model for PC near Tg was confirmed and this material model can be used in FE analysis for the prediction and improvement of the micro thermal imprint process for pattern replication.

  • PDF

Bearing Faults Localization of a Moving Vehicle by Using a Moving Frame Acoustic Holography (이동 프레임 음향 홀로그래피를 이용한 주행 중인 차량의 베어링 결함 위치 추정)

  • Jeon, Jong-Hoon;Park, Choon-Su;Kim, Yang-Hann;Koh, Hyo-In;You, Won-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.8
    • /
    • pp.816-827
    • /
    • 2009
  • This paper deals with a bearing faults localization technique based on holographic approach by visualizing sound radiated from the faults. The main idea stems from the phenomenon that bearing faults in a moving vehicle generate impulsive sound. To visualize fault signal from the moving vehicle, we can use the moving frame acoustic holography [Kwon, H.-S. and Kim, Y.-H., 1998, "Moving Frame Technique for Planar Acoustic Holography," J. Acoust. Soc. Am. Vol. 103, No. 4, pp. 1734${\sim}$1741]. However, it is not easy to localize faults only by applying the method. This is because the microphone array measures noise(for example, noise from other parts of the vehicle and the wind noise) as well as the fault signal while the vehicle passes by the array. To reduce the effect of noise, we propose two ideas which utilize the characteristics of fault signal. The first one is to average holograms for several frequencies to reduce the random noise. The second one is to apply the partial field decomposition algorithm [Nam, K.-U., Kim, Y.-H., 2004, "A Partial Field Decomposition Algorithm and Its Examples for Near-field Acoustic Holography," J. of Acoust. Soc. Am. Vol. 116, No. 1, pp. 172${\sim}$185] to the moving source, which can separate the fault signal and noise. Basic theory of those methods is introduced and how they can be applied to localize bearing faults is demonstrated. Experimental results via a miniature vehicle showed how well the proposed method finds out the location of source in practice.

An Experimental Study on Consolidation Effect of Dredged and Reclaimed Ground with PBD using Seepage Pressure (침투압을 이용한 PBD 타입 준설매립 지반의 압밀 효과에 관한 실험적 연구)

  • Lee, Moo-Chul;Park, Min-Chul;Kim, Ju-Hyun;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.13-24
    • /
    • 2012
  • In this study, the in-situ model test has been conducted and used to estimate and analyze consolidation behavior of the ground by using the miniature test that reconstructs economically geotechnical behavior of in-situ full scale structure. To analogize the relation among effective stress, void ratio and coefficient of permeability at the self-weight consolidation stage, the low stress seepage consolidation test has been conducted and the involution function of constitutive equation had been obtained from the result of the curve fitted seepage consolidation test result. As a result of the numerical analysis that had been conducted on the representative section using a constitute equation, final settlement was similar with those of self-weight consolidation of the centrifugal model test. But, it was more or less smaller. It seems that these trends are caused by the difference between estimated values.

The Design of Cardiovascular System Model Equipment for Education (심장 혈관계 시스템의 교육 모형 고안)

  • Won, Doyeon;Jung, Hongmoon;Jung, Jaeeun;Lee, Joonha
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.117-121
    • /
    • 2014
  • The understanding of medical knowledge regarding cardiac shape and cardiovascular system is essentially required for a medical personnel as well as a medical technician. Correct acquisition of medical knowledge through cardiac miniature model is very critical because it is directly related to a patient life. therefore replica model is necessary for the education regarding cardiac and cardiovascular system. In this study anatomical cardiovascular system on fluoroscopy can be shown by cardiac and cardiovascular fluoroscopy replica model. Also, it helps to understand a cardiovascular radiograph. Consequentially medical personnel and medical technician are able to take advantage of this equipment to understand cardiovascular fluoroscopy system.

Optimal Design of Gerotor with Combined Lobe Profiles (Ellipse 1-Elliptical Involute-Ellipse 2) (타원 1-타원형 인벌루트-타원 2 로브 형상의 제로터 최적 설계)

  • Kwak, Hyo Seo;Li, Sheng Huan;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1237-1244
    • /
    • 2015
  • A gerotor can be manufactured in a miniature size because it has a high discharge per cycle and a simple structure. Gerotors are widely used for the lubrication oil of an engine and as the hydraulic source of an automatic transmission. Recently, improvements in fuel efficiency and noise reduction have come to the fore in the automobile industry, and it has been necessary for better fuel efficiency to continuously improve the flow rate and noise of internal gear pumps through the optimal design of the gerotor and port shape. In this study, gerotors were generated based on the equations derived for a lobe shape with multiple profiles (ellipse 1-elliptical involute-ellipse 2). The ranges of the design parameters were considered to prevent a cusp and loop. In addition, the optimal lobe shape was obtained by determining the influence of the lobe shape on the performances (flow rate, irregularity, etc.), according to the values of the design parameters.

A Micro-robotic Platform for Micro/nano Assembly: Development of a Compact Vision-based 3 DOF Absolute Position Sensor (마이크로/나노 핸들링을 위한 마이크로 로보틱 플랫폼: 비전 기반 3자유도 절대위치센서 개발)

  • Lee, Jae-Ha;Breguet, Jean Marc;Clavel, Reymond;Yang, Seung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.125-133
    • /
    • 2010
  • A versatile micro-robotic platform for micro/nano scale assembly has been demanded in a variety of application areas such as micro-biology and nanotechnology. In the near future, a flexible and compact platform could be effectively used in a scanning electron microscope chamber. We are developing a platform that consists of miniature mobile robots and a compact positioning stage with multi degree-of-freedom. This paper presents the design and the implementation of a low-cost and compact multi degree of freedom position sensor that is capable of measuring absolute translational and rotational displacement. The proposed sensor is implemented by using a CMOS type image sensor and a target with specific hole patterns. Experimental design based on statistics was applied to finding optimal design of the target. Efficient algorithms for image processing and absolute position decoding are discussed. Simple calibration to eliminate the influence of inaccuracy of the fabricated target on the measuring performance also presented. The developed sensor was characterized by using a laser interferometer. It can be concluded that the sensor system has submicron resolution and accuracy of ${\pm}4{\mu}m$ over full travel range. The proposed vision-based sensor is cost-effective and used as a compact feedback device for implementation of a micro robotic platform.

Study on Deformation of Miniature Metal Bellows in Cryocooler Following Temperature Change of Internal Gas (내부 기체의 온도 변화에 따른 극저온 냉각기용 소형 금속 벨로우즈의 변형에 관한 연구)

  • Lee, Seung Ha;Lee, Tae Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.429-435
    • /
    • 2015
  • A bellows is an important temperature control component in a Joule-Thomson micro-cryocooler. It is designed using a very thin shell, and the inside of the bellows is filled with nitrogen gas. The bellows is made of a nickel-cobalt alloy that maintains its strength and elastic properties in a wide range of temperatures from cryogenic to $300^{\circ}C$. The pressure of the gas and the volume within the bellows vary according to the temperature of the gas. As a result, the bellows contracts or expands in the axial direction like a spring. To explore this phenomenon, the deformation of the bellows and its internal volume must be calculated iteratively under a modified pressure until the state equation of the gas is satisfied at a given temperature. In this paper, the modified Benedict-Webb-Rubin state equation is adopted to describe the temperature-volume-pressure relations of the gas. Experiments were performed to validate the proposed method. The results of a numerical analysis and the experiments showed good agreement.

Study on the Separation of MAs from HLLW and Their Extraction Behavior Using New Extractants of Amido Podand

  • An, Ye-Guo;Luo, Fang-Xiang;Zhu, Zhi-Xuan;Zhang, Xiang-Ye;Zhu, Wen-Bin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.245-256
    • /
    • 2004
  • The extraction of three kinds of amido podands, N,N,N'N'-tetrabutyl-3-oxa-pentanedi- amide (TBDGA), N,N,N'N'-tetra-isobutyl-3-oxa-pentanediamide(TiBDGA) and N,N,N'N'-tetra- butyl-3,6-dioxa-oct-anediam- ide(TBDOODA) on U(VI),Pu(IV), Am(III), Eu(III) and other metal ions is studied in nitric acid solutions. 40%octanol-kerosene is chosen as diluents to eliminate third phase and emulsion. TBDGA and TiBDGA show extraction selectivity to An(III) and Ln(III) much higher than to U(VI) and Pu(IV). Fe, Ru and Mo is poorly extracted by the three kinds of amid podands in 2~3mol/L $HNO_3$ solutions. Aiming to eliminate interface crude when using simulated HLLW solution in the system of 0.2mol/L TBDGA/Octanol+kerosene, acetohydroxyamic acid was adapted. Distribution ratio of zirconium was decreased when adding acetohydroxyamic acid in aqueous solution, and interface crude disappeared as mixing extractant with HLLW. The counter-current extraction test is carried out in a set of miniature mixer-settler, with 0.2mol/L TBDGA/ 40% octanol-kerosene as extractant to separate U(VI), Pu(IV), Am(III) and Eu(III) from simulated high level liquid waste(HLLW) solution. In battery A, lanthanides and actinides are coextracted into organic phase with the recovery of 99.98% for U(Ⅵ), >99.99% for Pu(IV), and >99.99% for Am(III) and Eu(III) respectively. In battery R1, 99.99% U, 86.2% Pu and a part of Am or Eu are stripped into aqueous phase by 0.2mol/L acetohydroxyamic acid (AHA) in 0.01mol/L $HNO_3$ solution. In battery $R_2$, Am, Eu and remained Pu are completely back-extracted by 0.2mol/L AHA. This separation process contains no salt reagent, and it is not necessary to dilute HLLW feed.

  • PDF

Deployment test of shape memory polymer specimens for space antenna design (우주 안테나 설계용 형상기억 폴리머 시편의 전개 시험)

  • Goo, Nam Seo;Le, Van Luong;An, Yongsan;Yu, Woong-Ryeol;Hwang, Jin Ok;Park, Jongkyoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.12
    • /
    • pp.1007-1012
    • /
    • 2017
  • In this study, we performed the deployment test of shape memory polymer specimens for space antenna design. Poly(cyclootene) was cross-linked by dicumyl peroxide to make a PCO shape memory polymer. A miniature specimen with 120 mm diameter for a deployable antenna was fabricated with the PCO shape memory polymer. To investigate the deployment performance, the folded specimen as a temporary shape was heated by two heaters to the $15^{\circ}C$ higher temperature than the glass transition temperature of shape memory polymer. Firstly, the specimen was installed horizontally and tested. The deploying motion was captured by a digital camera and analyzed by a Tracker program. To reduce the effects of gravity, the specimen was installed vertically and tested again. The deployment performance of a shape memory polymer was investigated by comparing the results of horizontal and vertical installation tests.

Review of the UBC Porcine Model of Traumatic Spinal Cord Injury

  • Kim, Kyoung-Tae;Streijger, Femke;Manouchehri, Neda;So, Kitty;Shortt, Katelyn;Okon, Elena B.;Tigchelaar, Seth;Cripton, Peter;Kwon, Brian K.
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.539-547
    • /
    • 2018
  • Traumatic spinal cord injury (SCI) research has recently focused on the use of rat and mouse models for in vivo SCI experiments. Such small rodent SCI models are invaluable for the field, and much has been discovered about the biologic and physiologic aspects of SCI from these models. It has been difficult, however, to reproduce the efficacy of treatments found to produce neurologic benefits in rodent SCI models when these treatments are tested in human clinical trials. A large animal model may have advantages for translational research where anatomical, physiological, or genetic similarities to humans may be more relevant for pre-clinically evaluating novel therapies. Here, we review the work carried out at the University of British Columbia (UBC) on a large animal model of SCI that utilizes Yucatan miniature pigs. The UBC porcine model of SCI may be a useful intermediary in the pre-clinical testing of novel pharmacological treatments, cell-based therapies, and the "bedside back to bench" translation of human clinical observations, which require preclinical testing in an applicable animal model.