• Title/Summary/Keyword: min-min

Search Result 127,563, Processing Time 0.099 seconds

Effect of Microcurrent Stimulation at Hand Somatic Acupuncture Points on Experimental Pain Threshold (미세전류가 수부체성경혈점의 실험적 통증 역치에 미치는 영향)

  • Cho Jung-Sun;Chen Jae-Kyun;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.85-93
    • /
    • 1994
  • The purposes of this study were 1) to examine the effects of microcurrent electrical neuromuscular stimulation 2) to compare surface electrode with needle electrode at somatic acupuncture points on experimental pain threshold measured at the distal end of the radius 3) to determine the changes in effect over time. A total of sixty healthy adult male and female subjects were assigned randomly to one of two experimental group or to a control group. Group 1(n=20) received MENS(Microcurrent Electrical Neuromuscular Stimulation) with surface electrode. Group 2(n=20) received HENS with needle electrode. Group 3(n=20) received no MENS. It measured experimental pain threshold at the wrist on pretreatment, 0 min after treatment. 15 min after treatment, 30 min after treatment in two experimental group. The results were as follows: 1. Experimental pain thresholds were higher in males than females(P<0.01). 2. Only the experimental group exhibited a significant increased in pain threshold after MENS treatment(P<0.05). 3. Surface electrode group increased significant pain threshold 0 min, 15 min after treatment, but greatly decrease 30 min after treatment. 4. Needle electrode group increased significant pain threshold 0 min, 15 min after treatment, but decrease 30 min after treatment. The results suggest that MENS applied to appropriate somatic acupuncture point can increase pain threshold. Further research is needed to assess the effects of greatly variety intensity of MENS of pain sufferes.

  • PDF

The Mean Transit Time of the CBD and the Afferent Loop Using $^{99m}Tc-DISIDA$ Scintigram in Truncal Vagotomy (미주신경간절제술에 있어서 $^{99m}Tc-DISIDA$ 신티그램을 이용한 총수담관 및 Afferent loop의 평균지연시간)

  • Moon, Tae-Yong;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.2
    • /
    • pp.199-203
    • /
    • 1988
  • The authors observed functional change of the CBD and the afferent loop with the transit time of $^{99m}Tc-DISIDA$ scintigram in patients treated by the surgical operation of gastric ulcers and cancer at Busan National University Hospital from June, 1987 to April, 1988. So authors estimated the time between the peak activity of the CBD and the afferent loop (TCA), the half transit time of the CBD activity (t 1/2 CBD) and the half transit time of the afferent loop activity (t 1/2 A-loop) in 9 patients undergone truncal vagotomy, who have no specific symptoms at 2 to 6 months after the operation, 5 patients undergone the operation without truncal vagotomy, and 7 persons as a control group. The results were as follows: I) In control group, the mean TCA, t 1/2 CBD and t 1/2 duodenum were $8.6{\pm}9.0$ min, $38.7{\pm}17.3$ min. and $28.6{\pm}10.9$ min, respectively. 2) In the operation group without truncal vagotomy, the mean TCA, t 1/2 CBD and t 1/2 A-loop were $10.0{\pm}7.1$ min. $48.2{\pm}22.3$ min. and $39.4{\pm}26.7$ min. respectively. 3) In the operation group with truncal vagotomy, the mean TCA, t 1/2 CBD and t 1/2 A-loop were $15.0{\pm}8.7$ min., $36.1{\pm}16.5$ min. and $42.6{\pm}24.4$ min, respectively. From the above results, we concluded that the transit time of the CBD and the afferent loop is not affected by truncal vagotomy.

  • PDF

Evaluating Feeding of Organic Waste and Stirring Interval to Optimize Anaerobic Digestion

  • Kim, Gi-Woong;Kim, Sang-Hun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.366-376
    • /
    • 2014
  • Purpose: In the process of anaerobic digestion, stirring of the digester and feeding of organic waste into the digester have been considered important factors for digestive efficiency. The objective of this study was to determine the most appropriate conditions for both stirring interval of the digester and organic feeding frequency in order to improve anaerobic digestion performance. Methods: A 5-L anaerobic digester was used to conduct continuous batch tests to process swine manure and food waste. Four different stirring intervals of the digester were used: 5 min/h, 10 min/2 h, 15 min/3 h, and 20 min/4 h. Results: The application of swine manure to the digester every 5 min/h resulted in the highest production of biogas as well as the highest removal rates of volatile solids (VS) and total chemical oxygen demand. Stirring the digester with a mixture of swine manure and food waste at intervals of 5min/h and 10min/2 h produced the highest biogas yields of 515.3 mL/gVS and 521.1 mL/gVS, respectively. To test different supply frequencies, organic waste was added to the digester in either a 12-hor 24-h cycle. The 24-h cycle produced 1.5-fold greater biogas production than that during the 12-h cycle. Conclusions: Thus, from the above results, to optimize anaerobic digestion performance, the ideal stirring condition must be 5min/h for swine manure feeding and 10min/2h for co-digestion of food waste and swine manure in a 24-h cycle.

Contrast Sensitivity as a function of spatial frequency by using polarization (편광을 이용한 눈의 공간주파수-대비민감도 함수 측정기구 설계)

  • Kim, Young-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2000
  • It was to adjust the luminance of light by the rotation angle of the polarizes and analyzer. The luminance value Lmax, Lmin of Contrast Sensitivity could be obtained from the rotation angle ${\theta}_m$ of the average luminance($L_m$), the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the maximum and the minimum's amplitude. $$L_{max}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1+C_s^{-1})$$ $$L_{min}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1-C_s^{-1})$$ We obtained the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the polarizes and analyzer from the rotation angle ${\theta}_m$ of the average luminance($L_m$) and the Contrast Sensitivity($C_s$). $${\theta}_{max}=cos^{-1}[cos{\theta}_m{\cdot}(1+C_s^{-1})^{1/2}]$$ $${\theta}_{min}=cos^{-1}[cos{\theta}_m{\cdot}(1-C_s^{-1})^{1/2}]$$.

  • PDF

The Energy Expenditure of Female Farmers in Kyungki Area (경기일부지역 농촌주부의 농작업에너지 대사)

  • Kim, Hwa-Nim;Lee, Dong-Tae;Rhie, Seung-Gyo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.18 no.2
    • /
    • pp.189-194
    • /
    • 1989
  • This study was carried out on 10 persons of female farmers to determine the energy expenditure of agricultural work. Their mean age was 44 year-old, mean daily urinary nitrogen excretion was 11.3g, and creatinine excretion was 0.183g. The energy metabolism was determined by indirect calorimetry using Douglas bag and Scholander's gas analyzer. The measured basal metabolism was 1,273 kcal per day and rest metabolism was 1,614 kcal per day. To remove seedling from the seedplot, they spent 2.479kcal per minute, to weed 2.805kcal/min, and to reap with sickle 4.58kcal/min. Energy expenditure of the same work, only sitting on the stool, was significantly reduced. Prolonged work did not change energy expenditure per minute significantly.

  • PDF

Efficient Processing of Multipoints MAX/MIN Queries in OLAP Environment (OLAP 환경에서 다중점 MAX/MIN 질의의 효율적인 처리기법)

  • Yang, Woo-Suk;Kim, Myoung-Ho
    • Journal of KIISE:Databases
    • /
    • v.27 no.1
    • /
    • pp.13-21
    • /
    • 2000
  • Online analytical processing (OLAP) systems are introduced to support decision support systems. Many researches focussed on efficient processing of aggregate functions that usually occur in OLAP queries. However, most previous researches in the literature are deal with the situation in which aggregate functions arc applied to all the values in a given range. Since those approaches utilize characteristic of aggregate functions applied to a range, they are difficult to be applied to a muitipoint query that is a query considering only some points in a given range. In this paper, we propose the Ranking Index and the flanking Decision Tree (RDT) for efficient evaluation of multipoints MAX/MIN queries. The ranking of possible MAX/MIN values are computed with RDT Then MAX/MIN values can be acquired from the Ranking Index. We show through experiments that our method provides high performance in most situations. In other words, the proposed method is robust as well as efficient. A single common set of precomputed results for both MAX and MIN values is another advantage of the proposed method.

  • PDF

Determination of Proper Loading Speed for Deformation Strength Test of Asphalt Concretes (아스팔트 콘크리트 변형강도 시험에서의 적정 하중재하속도 선정 연구)

  • Cho, Byung-J.;Park, Tae-W.;Doh, Young-S.;Kim, Kwang-W.
    • International Journal of Highway Engineering
    • /
    • v.10 no.4
    • /
    • pp.225-234
    • /
    • 2008
  • This study was carried out to select proper loading speed for deformation strength ($S_D$) of asphalt mixtures. Kim test using loading head of diameter(40mm) with radius(10mm) was conducted to measure $S_D$ in different loading speed (10mm/min, 30mm/min, 50mm/min, 70mm/min) and wheel tracking test was also conducted. The regression analyses between the So values and WT results were carried out by loading speeds. Higher $S_D$ was observed as increasing loading speed. This means that loading speed is a high influencing factor on $S_D$. The loading speed of 30mm/min was found as an optimum for better correlation with WT results than any other speeds from the regression analysis between $S_D$ and wheel tracking test results. $S_D$ value measured at other loading speed than 30mm/min has to apply the conversion coefficients.

  • PDF

Fabrication of the Nano-Sized Nickel Oxide Powder by Spray Pyrolysis Process

  • Yu, Jae-Keun;NamGoong, Hyun;Kim, Dong-Hee
    • Korean Journal of Materials Research
    • /
    • v.22 no.8
    • /
    • pp.426-432
    • /
    • 2012
  • This study involves using nickel chloride solution as a raw material to produce nano-sized nickel oxide powder with average particle size below 50 nm by the spray pyrolysis reaction. The influence of the inflow speed of raw material solution on the properties of the produced powder is examined. When the inflow speed of the raw material solution is at 2 ml/min., the average particle size of the powder is 15~25 nm and the particle size distribution is relatively uniform. When the inflow speed of the solution increases to 10 ml/min., the average particle size of the powder increases to about 25 nm and the particle size distribution becomes much more uneven. When the inflow speed of the solution increases to 20 ml/min., the average particle size of the powder increases in comparison to the case in which the inflow speed of the solution was 10 ml/min. However, the particle size distribution is very uneven, showing various particle size distributions ranging from 10 nm to 70 nm. When the inflow speed of solution increases to 50 ml/min., the average particle size of the powder decreases in comparison to the case in which the inflow speed was 20 ml/min., and the particle size distribution shows more evenness. As the inflow speed of the solution increases from 2 ml/min. to 20 ml/min., the XRD peak intensities gradually increase, while the specific surface area decreases. When the inflow speed of solution increases to 50 ml/min., the XRD peak intensities rather decrease, while the specific surface area increases.

Feasibility of Dacryoscintigraphy in Normal Dogs (정상 개에서 누비공신티그라피의 적용)

  • Cho, Young-Kwon;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.559-564
    • /
    • 2010
  • The purpose of this study was to evaluate the value of dacryoscintigraphy with Tc-99 m Pertechnetate, which is useful in functional nasolacrimal duct obstruction diagnosis in human medical science, by applying it to normal dogs. Dacryoscintigraphy was performed on six clinically healthy beagle dogs to confirm normal passage of their lacrimal ducts. The scintigraphic images of both lacrimal system were obtained at 5 min, 10 min, and 20 min after Tc-99 m Pertechnetate administration, respectively. If lacrimal duct does not come into view within 20 min, delayed images at 30min, 45min and 60 min were gained. After drawing ROI of left and right canaliculus, lacrimal sac, and nasolacrimal duct acquired after dacryoscintigraphy, we measured each counting rate and developed a counting rate table for each time interval. Of the total of 12 places, 10 (83.3%) showed patency within 20 min, and 11 (91.6%) showed patency within 30 min. In one dog, a functional obstruction of right lacrimal canal was observed. Dacryoscintigraphy could provide useful information about functional and anatomical lacrimal duct obstruction in veterinary medicine as well as in clinical research.

Effects of Endotracheal Suction and Position Change on Blood Pressure of Patients with Head and Intracranial Surgery (기관내 흡인과 체위변경이 두부 및 두 개내 수술을 받은 환자의 혈압에 미치는 영향)

  • Jo, Eun Hee;Jung, Yoo Jung;Kim, Eun Jin
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.3
    • /
    • pp.226-234
    • /
    • 2014
  • Purpose: This study was done to present guidelines for deciding appropriate times for measuring blood pressure (BP) in patients with neurological disorders who had surgery due to brain damage. Method: It was a repeated measures-experimental research on time variants in BP after nursing care. SBP (Systolic BP) and DBP (Diastolic) were measured every 2 minutes up to 5 times using an EKG patient monitor. Measured data were analyzed using repeated measures ANOVA and paired t-test. Results: For suctioning, there were significantly higher differences for SBP averages after 2 min. (138mmHg, p<0.01) and 4 min. (133mmHg, p<0.01) compared to before suctioning (120mmHg). For position change, there were significant differences in SBP averages after 2 min. (136mmHg, p<0.01) and 4 min. (130mmHg, p=0.01) compared to before changing position (121mmHg). For position change followed by suctioning there were significant differences in SBP averages after 2 min. (136mmHg, p<0.01), 4 min. (136mmHg, p<0.01) and 6 min. (125mmHg, p=0.003) compared to before the interventions (121mmHg). Conclusions: Results indicate that there are significant differences in SBP and DBP over time during nursing interventions, suggesting clinical measurement of BP after 6 min. or 8 min. be done for patients with neurological disorders in neurosurgery clinics.