• Title/Summary/Keyword: min-max operation

Search Result 68, Processing Time 0.022 seconds

Conceptual Design of Safety Step System in Urban Railway Platforms (도시철도 승강장 안전발판 시스템 개념설계)

  • Park, Min-Heung;Kwak, Hee-Man;Kim, Min-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2559-2566
    • /
    • 2014
  • Recently, safety accident by misstep at the gap between the platform and railway vehicle have frequently occurred to the mobility handicapped including disabled person, children etc. in metropolitan subway region. Particularly, because the curved platform's gap from platform to railway vehicle is max. 260mm it is important to securement of the passenger's safe mobility right. So it is necessary to platform safety step equipment for needs technology to interface gap between the platform and railway vehicle. In this study we examined the function & production requirements of platform safety step and performed the conceptual design considering the crash safety and maintenance easiness. Moreover, considering various performance requirements we suggested step's operation procedure & control flowchart.

Character Region Detection in Natural Image Using Edge and Connected Component by Morphological Reconstruction (에지 및 형태학적 재구성에 의한 연결요소를 이용한 자연영상의 문자영역 검출)

  • Gwon, Gyo-Hyeon;Park, Jong-Cheon;Jun, Byoung-Min
    • Journal of Korea Entertainment Industry Association
    • /
    • v.5 no.1
    • /
    • pp.127-133
    • /
    • 2011
  • Characters in natural image are an important information with various context. Previous work of character region detection algorithms is not detect of character region in case of image complexity and the surrounding lighting, similar background to character, so this paper propose an method of character region detection in natural image using edge and connected component by morphological reconstructions. Firstly, we detect edge using Canny-edge detector and connected component with local min/max value by morphological reconstructed-operation in gray-scale image, and labeling each of detected connected component elements. lastly, detected candidate of text regions was merged for generation for one candidate text region, Final text region detected by checking the similarity and adjacency of neighbor of text candidate individual character. As the results of experiments, proposed algorithm improved the correctness of character regions detection using edge and connected components.

The Study on the Effect of Electroacupuncture at Ciliao(BL32) on Voiding Pattern and Uroflowmetry in the Patients with Functional Voiding Disease (차류혈(次謬穴) 전침(電鍼)의 기능성(機能性) 배뇨장애(排尿障碍) 환자(患者)에 대한 임상적(臨床的) 관찰(觀察) - 배뇨일지(排尿日誌)와 요속검사(尿速檢査)를 중심으로 -)

  • Kim, Kyung-Tai;Ko, Young-Jin;Kim, Eun-Jung;Ryu, Seong-Ryong;Woo, Hyun-Su;Kim, Chang-Hwan
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.101-113
    • /
    • 2006
  • Objectives : This study was designed to evaluate the effect of electroacupuncture at ciliao(BL32) on voiding pattern and uroflowmetry of patients with functional voiding disease. Methods Subjects were voluntarily recruited by newspaper·s and internet. All the subjects were confirmed as International Prostatism Symptom Score(IPSS), uroflowmetry, voiding diary, symptom. The acupuncture therapy was performed 3 times a week for 3 weeks by oriental medical doctor at hospital. Acupuncture points were BL32. The patient's symptoms were assessed before and after 3 weeks treatments by IPSS. Uroflowmetry for 5minutes and voiding diary for 48 hours was measured before and after 3 weeks treatments. Results : The results were as follows; 1. After 3 weeks compared to the pre-treatment, IPSS(QOL) scores were significantly unproved. 2. After 3 weeks compared to the pre-treatment, mean voiding volume, min voiding volume and mean voiding time on voiding daiary was significantly improved. 3. After 3 weeks compared to the pre-treatment, max flow velocity and mean flow velocity on uroflowmetry in spite of increase of voiding volume show a statistically significant difference. 4. Acupunctue had hardly some side effect compared to operation and medicines and was economical. Conclusion : This study suggests that acupuncture treatments can be applicable to improve symptoms in the patients with functional voiding disease. Further study on the acupuncture and other acupoints in the patients with functional voiding disease is recommended.

  • PDF

LONG-TERM EVALUATION OF MANDIBULAR CONDYLE FRACTURES (하악 과두 골절에 관한 장기추적조사연구)

  • Min, Seung-Ki;Park, Sang-Kyu;Oh, Seung-Hwan;Kwon, Kyung-Hwan;Choi, Mun-Ki;Chae, Young-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.6
    • /
    • pp.535-544
    • /
    • 2005
  • The management of mandibular condyle fractures continues to be a subject of much debate. It is suggested that, if not properly managed, these fractures may give rise to serious problems, such as malocclusion, mouth opening limitation, temporomandibular joint disorders. Treatment planing of mandibular condyle fractures is very important. The aim of this present study was to evaluate the long-term results according to treatment methods in condylar fractures. Also, it was to evaluate results of treatment according to condylar fracture level. We conducted a retrospective analysis of 43 mandibular condyle fractures. 43 patients followed for average period of 9.00 years(mini. 7yr, max. 12yr). All patients underwent a clinical and radiologic evaluation focusing on mouth opening, mandibular movements, TMJ function, change of ramal height, condylar remodelling. If the level of fracture was positioned in high, especially in level II, mandibular movement disability and ramus length loss was more prominent. This results were similar to the cases of treatment of fragment removal. In high level fracture and fragment removal cases, It is thought that more intensive and long term management are needed than other treatment cases using different operation methods. Also, direct fixation by each approach showed good results in mandibular movement, ramal height change and condylar shape. Through this results, accurate reduction of the mandibular condyle fractures was a very important factor in postoperative prognosis.

Water-hammer in the Pump Pipeline System with and without an Air-Chamber (에어챔버 설치에 따른 펌프관로계의 수격현상)

  • Lee, Sun-Kon;Yang, Cheol-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • When the pumps stopped in the operation by the power failure, the hydraulic transients take place in the sudden change of a velocity of pipe line. Each and every water hammer problem shows the critical stage to be greatly affected the facts of safety and reliability in case of power failure. The field tests of the water hammer executed at Cheong-Yang booster pump station having an air chamber. The effects were studied by both the practical experiments and the CFD(Computational Fluid Dynamics : Surge 2008). The result states that the system with water hammering protection equipment was much safer when power failure happens. The following data by a computational fluid dynamic analysis are to be shown below, securing the system stability and integrity. (1) With water hammering protection equipment. (1) Change of pressure : Up to $15.5\;kg/cm^2$ in contrary to estimating $16.88\;kg/cm^2$. (2) Change rate of water level : 52~33% in contrary to estimating 55~27%. (3) Note that the operational pressure of pump runs approx. 145 m, lowering 155 m of the regularity head of pump. (4) Note that the cycle of water hammering delays from 80 second to 100 second, together with easing the function of air value at the pneumatic lines. (2) Change of pressure without water hammering protection equipment : Approximate $22.86\;kg/cm^2$. The comprehensive result says that the computational fluid dynamics analysis would match well with the practical field-test. It was able to predict Max. or Min. water hammering time in a piping system. This study aims effectively to alleviate water hammering in a pipe line to be installed with air chamber at the pumping station and results in making the stability of pump system in the end.

Development of Large-Area RF Ion Source for Neutral Beam Injector in Fusion Devices

  • Chang, Doo-Hee;Jeong, Seung Ho;Kim, Tae-Seong;Park, Min;Lee, Kwang Won;In, Sang Ryul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.179.2-179.2
    • /
    • 2013
  • A large-area RF-driven ion source is being developed at Germany for the heating and current drive of ITER device. Negative hydrogen ion sources are major components of neutral beam injection (NBI) systems in future large-scale fusion experiments such as ITER and DEMO. The RF sources for the production of positive hydrogen ions have been successfully developed at IPP (Max-Planck-Institute for Plasma Physics), Garching, for the ASDEX-U and W7-AS neutral beam heating systems. Ion sources of the first NBI system (NBI-1) for the KSTAR tokamak have been developed successfully with a bucket plasma generator based on the filament arc discharge, which have contributed to achieve a good plasma performance such as 15 sec H-mode operation with an injection of 3.5 MW NB power. There is a development plan of RF ion source at the KAERI to extract the positive ions, which can be used for the second NBI system (NBI-2) of the KSTAR and to extract the negative ions for future fusion devices such as Fusion Neutron Source and Korea-DEMO. The development progresses of RF ion source at the KAERI are described in this presentation.

  • PDF

Building battery deterioration prediction model using real field data (머신러닝 기법을 이용한 납축전지 열화 예측 모델 개발)

  • Choi, Keunho;Kim, Gunwoo
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.2
    • /
    • pp.243-264
    • /
    • 2018
  • Although the worldwide battery market is recently spurring the development of lithium secondary battery, lead acid batteries (rechargeable batteries) which have good-performance and can be reused are consumed in a wide range of industry fields. However, lead-acid batteries have a serious problem in that deterioration of a battery makes progress quickly in the presence of that degradation of only one cell among several cells which is packed in a battery begins. To overcome this problem, previous researches have attempted to identify the mechanism of deterioration of a battery in many ways. However, most of previous researches have used data obtained in a laboratory to analyze the mechanism of deterioration of a battery but not used data obtained in a real world. The usage of real data can increase the feasibility and the applicability of the findings of a research. Therefore, this study aims to develop a model which predicts the battery deterioration using data obtained in real world. To this end, we collected data which presents change of battery state by attaching sensors enabling to monitor the battery condition in real time to dozens of golf carts operated in the real golf field. As a result, total 16,883 samples were obtained. And then, we developed a model which predicts a precursor phenomenon representing deterioration of a battery by analyzing the data collected from the sensors using machine learning techniques. As initial independent variables, we used 1) inbound time of a cart, 2) outbound time of a cart, 3) duration(from outbound time to charge time), 4) charge amount, 5) used amount, 6) charge efficiency, 7) lowest temperature of battery cell 1 to 6, 8) lowest voltage of battery cell 1 to 6, 9) highest voltage of battery cell 1 to 6, 10) voltage of battery cell 1 to 6 at the beginning of operation, 11) voltage of battery cell 1 to 6 at the end of charge, 12) used amount of battery cell 1 to 6 during operation, 13) used amount of battery during operation(Max-Min), 14) duration of battery use, and 15) highest current during operation. Since the values of the independent variables, lowest temperature of battery cell 1 to 6, lowest voltage of battery cell 1 to 6, highest voltage of battery cell 1 to 6, voltage of battery cell 1 to 6 at the beginning of operation, voltage of battery cell 1 to 6 at the end of charge, and used amount of battery cell 1 to 6 during operation are similar to that of each battery cell, we conducted principal component analysis using verimax orthogonal rotation in order to mitigate the multiple collinearity problem. According to the results, we made new variables by averaging the values of independent variables clustered together, and used them as final independent variables instead of origin variables, thereby reducing the dimension. We used decision tree, logistic regression, Bayesian network as algorithms for building prediction models. And also, we built prediction models using the bagging of each of them, the boosting of each of them, and RandomForest. Experimental results show that the prediction model using the bagging of decision tree yields the best accuracy of 89.3923%. This study has some limitations in that the additional variables which affect the deterioration of battery such as weather (temperature, humidity) and driving habits, did not considered, therefore, we would like to consider the them in the future research. However, the battery deterioration prediction model proposed in the present study is expected to enable effective and efficient management of battery used in the real filed by dramatically and to reduce the cost caused by not detecting battery deterioration accordingly.

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF