• Title/Summary/Keyword: microwave system

Search Result 874, Processing Time 0.029 seconds

Microwave Dielectric Absorption Spectroscopy Aiming at Novel Dosimetry Using DNAs

  • Izumi, Yoshinobu;Hirayama, Makoto;Matuo, Youichirou;Sunagawa, Takeyoshi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.21-25
    • /
    • 2017
  • Background: We are developing L-band and S-band microwave dielectric absorption systems aiming novel dosimetry using DNAs, such as plasmid DNA and genomic DNA, and microwave technology. Materials and Methods: Each system is composed of a cavity resonator, analog signal generator, circulator, power meter, and oscilloscope. Since the cavity resonator is sensitive to temperature change, we have made great efforts to prevent the fluctuation of temperature. We have developed software for controlling and measurement. Results and Discussion: By using this system, we can measure the resonance frequency, f, and ${\Delta}Q$ (Q is a dimensionless parameter that describes how under-damped an oscillator or resonator is, and characterizes a resonator's bandwidth relative to its center frequency) within about 3 minutes with high accuracy. Conclusion: This system will be expected to be applicable to DNAs evaluations and to novel dosimetric system.

System Requirement Analysis of Passive Microwave Radiometer in Earth Observation Satellite (지구관측위성 수동형 마이크로파 라디오미터의 시스템 설계 요구 사항 분석 연구)

  • Ryu, Sang-Burm;Yong, Sang-Soon;Lee, Sang-Kon;Lee, Seung-Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.2
    • /
    • pp.87-96
    • /
    • 2012
  • In this research, we describe recent technologies and system requirements of the passive microwave radiometer used in Earth observation satellites. And we classify types of microwave radiometer system for Earth observation satellites according to observation targets and ways to scan and discuss a design method. Also, requirements of passive radiometer for Earth observation missions in the latest practical examples used and developed are analyzed in this research.

Study on the Application of Microwave-Heating System for Making Bent-Wood Furniture(I) - Solid-Wood Bending Properties of Robinia pseudo-acacia L. by Microwave-Heating - (국산재(國産材) 곡목가구(曲木家具) 제조(製造)를 위한 Microwave-Heating System 활용에 관한 연구(I) - Microwave-Heating에 의한 아까시나무의 소재(素材)휨가공 특성 -)

  • So, Won-Tek;Chai, Jyung-Ki
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.73-82
    • /
    • 1995
  • Black locust trees(Robinia pseudo-acacia L.) are growing widely in Korea and have been used to get honey and animal feed, but they have seldom been used as manufacturing materials. This study was carried out to evaluate the possibility of using black locust as bent-wood furniture materials. Softening methods were steaming and micro-wave heating. The specimens of 15${\times}$15${\times}$350mm were all air-dried. For softening, specimens were steamed at 100$^{\circ}C$ for 7 min, or microwave heated for 35 seconds. It is known that microwave heating softens wood much faster than steaming. The bending processing conditions are showed in Table 7. The minimum solid-bending radii of black locust were 40mm for steaming and 150mm for micro-wave heating, respectively. In conclusion the steamed black locust, showed very good solid bending properties, but the bending properties of micro-wave heated black locust were not sufficient for bent-wood furniture.

  • PDF

Changes in Methyl Pyrazines of Cocoa Beans during Microwave Roasting (Microwave Roasting에 의한 Cocoa Bean의 Methyl Pyrazine류의 변화)

  • Lee, Joo-Hee;Kim, Suk-Shin
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.654-658
    • /
    • 2000
  • Flavor components focused on the methyl pyrazines(2,3-dimethyl pyrazine, 2,3,5-trimethyl pyrazine, tetramethyl pyrazine) of microwave-roasted cocoa beans were determined and compared with those of conventionally-roasted cocoa beans. Domestic microwave oven was modified to design the microwave roasting system. Temperature measurement technique using thermocouple probes was developed to determine the center temperature of cocoa beans during microwave roasting. Microwave roasting was carried out under two different conditions. Under the first condition, roasting time was fixed to 30 min, while roasting temperature was varied to $110^{\circ}C,\;120^{\circ}C,\;130^{\circ}C,\;140^{\circ}C,\;and\;150^{\circ}C$ Under the second condition, roasting temperature was fixed to $130^{\circ}C$, while roasting time was varied to 5 min, 10 min, 20 min, and 30 min. Conventional roasting was done at $120^{\circ}C$ for 15 min as a reference. Amount of methyl pyrazines and their ratios were influenced by microwave roasting temperature and roasting time. The most suitable methyl pyrazine ratio of cocoa beans was obtained at $140^{\circ}C$ for 30 min of microwave roasting.

  • PDF

Preclinical Prototype Development of a Microwave Tomography System for Breast Cancer Detection

  • Son, Seong-Ho;Simonov, Nikolai;Kim, Hyuk-Je;Lee, Jong-Moon;Jeon, Soon-Ik
    • ETRI Journal
    • /
    • v.32 no.6
    • /
    • pp.901-910
    • /
    • 2010
  • As a supplement to X-ray mammography, microwave imaging is a new and promising technique for breast cancer detection. Through solving the nonlinear inverse scattering problem, microwave tomography (MT) creates images from measured signals using antennas. In this paper, we describe a developed MT system and an iterative Gauss-Newton algorithm. At each iteration, this algorithm determines the updated values by solving the set of normal equations using Tikhonov regularization. Some examples of successful image reconstruction are presented.

Microwave Radiometer for Space Science and DREAM Mission of STSAT-2

  • Kim, Y.H.
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.31.4-32
    • /
    • 2008
  • The microwave instruments are used many areas of the space remote sensing and space science applications. The imaging radar of synthetic aperture radar (SAR) is well known microwave radar sensor for earth surface and ocean research. Unlike radar, microwave radiometer is passive instrument and it measures the emission energy of target, i.e. brightness temperature BT, from earth surface and atmosphere. From measured BT, the geophysical data like cloud liquid water, water vapor, sea surface temperature, surface permittivity can be retrieved. In this paper, the radiometer characteristics, system configuration and principle of BT measurement are described. Also the radiometer instruments TRMM, GPM, SMOS for earth climate, and ocean salinity research are introduce. As first korean microwave payload on STSAT-2, the DREAM (Dual-channels Radiometer for Earth and Atmosphere Monitoring) is described the mission, system configuration and operation plan for life time of two years. The main issues of DREAM unlike other spaceborne radiometers, will be addressed. The calibration is the one of main issues of DREAM mission and how it contribute on the space borne radiometer. In conclusion, the radiometer instrument to space science application will be considered.

  • PDF

Effect of Dopants on the Microwave Dielectric Properties of $(1-x)MgTiO_3-xCaTiO_3$ Ceramics (불순물 첨가에 따른 $(1-x)MgTiO_3-xCaTiO_3$ 세라믹스의 마이크로웨이브 유전특성변화)

  • 우동찬;이희영;한주환;김태홍;최태구
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.8
    • /
    • pp.843-853
    • /
    • 1997
  • The effect of dopant on microwave dielectric properties of (1-x)MgTiO3-xCaTiO3 ceramics, known to be used as microwave dielectric resonators for global positioning system and personal communication system, has been analyzed in terms of variations in defect concentrations and microstructural features with its addition. The addition of dopants was revealed to result in a significant change in the microstructure as well as defect concentration of the ceramics. For instance, the quality factor is proportional to sintered density of the ceramics by inversely proportional to grain size as well as vacancy concentration. Accordingly, it is believed that the dopant effect on the microwave dielectric properties should be separately analyzed with either microstructural change or the change in vacancy concentration.

  • PDF

A Study on the Dieless Wire Drawing Using Microwave (마이크로웨이브를 이용한 Dieless Wire Drawing 에 대한 연구)

  • Huh You;Kim S.H.;Kim J.S.;Kim I.S.;Paik Y.N.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.942-945
    • /
    • 2005
  • Micron-sized metal wires are widely used in industries such as filtration, catalyst and composite materials, etc. In the wire drawing process, the die that is used conventionally is an effective and, at the same time, sensitive component. However, a typical array of the dies has caused many problems in the wire drawing process, e.g., large frictional force on the interface between wire and the resulting high heat generation, precise adjustment of the dies, extended cooling system, die abrasion, etc.. Because of these problems, there have been many works that are aiming at improving the efficiency of wire drawing process by analyzing the die geometry and by applying advanced die material to prolong the die life or even at developing a dieless wire drawing system. This paper is dealing with developing a new wire drawing system that is applicable to reduce the wire drawing steps with high draw ratio. The new wire drawing system does not use the dies, but use the self-induced heater that works on the basis of the resonant phenomenon of wire material. The electromagnetic wave is the heating source. The results of the study on the diameter reduction and microwave flow analysis show that the heating effectiveness of the wire is influenced by the energy distribution in the microwave propagation chamber. We can obtain diameter-reduced wires by using microwave in the dieless drawing process. Microwave as a heating source is capable of producing wires without applying dies in wire drawing process.

  • PDF

The Effect of $WO_3$ Addition on Microwave Dielectric Properties in $BaTiO_3-3{(1-x)TiO_2-xWO_3}$ System ($WO_3$ 첨가량 변화에 따른 $BaTiO_3-3{(1-x)TiO_2-xWO_3}$ 계의 고주파 유전특성)

  • 박찬식;변재동;김왕섭;김경용
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.4
    • /
    • pp.448-454
    • /
    • 1995
  • The effect of WO3 addition on microwave dielectric properties of BaTiO3-3{(1-x)TiO2-xWO3} system was studied. Addition of WO3 to this system resulted in the formation of BaWO4 and Ba2Ti9O20 phases. Both the dielectric constant (K) and the temperature coefficientof resonant frequency (Tf) were decreased with the amount of WO3 addition. The value of Q$\times$f0 was increased as the amount of WO3 was increased up to x=0.0275, and then decreased when x exceeded 0.03. At x=0.0275, this ceramic showed excellent microwave proprties of K=34-35, Q$\times$f0=50,000-53,000, and near zero ppm/$^{\circ}C$ of Tf.

  • PDF