• 제목/요약/키워드: microwave emission

검색결과 158건 처리시간 0.026초

Effect of FTO coated on stainless steel bipolar plate for PEM fuel cells

  • 박지훈;장원영;변동진;이중기
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.55.2-55.2
    • /
    • 2009
  • A polymer electrolyte membrane (PEM) fuel cell has been getting large interest as a typical issue in useful applications. The PEMFC is composed of a membrane, catalyst and the bipolar plate. SnOx:F films on SUS316 stainless steel were prepared as a function of substrate with using electron cyclotron resonance-metal organic chemical vapor deposition (ECR-MOCVD) in order to achieve the corrosion-resistant and low contact resistance bipolar plates for PEM fuel cells. The SnOx:F films coated on SUS316 substrate at surface plasma treatment for excellent stability, before/after heat treatment for good crystalline structure and microwave power for were characterized by X-ray diffraction (XRD), auger electron microscopy (AES) and field emission-scanning electron microscopy (FE-SEM). The SnOx:F film coated on SUS316 substrate with various process parameters were able to observe optimum interfacial contact resistance (ICR) and corrosion resistance. It can be concluded that fluorine-doping content plays an important function in electrical property and characteristic of corrosion-protective film.

  • PDF

증착변수 및 첨가가스에 따른 다이아몬드 박막의 구조적 물성 및 전계방출 특성의 변화 분석 (Characterization of structural and field-emissive properties of diamond films in terms of growth conditions and additive gases)

  • 박재현;이태훈;박창균;서수형;박진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1571-1573
    • /
    • 2003
  • Diamond films including nanocystalline and graphite phase are grown by microwave plasma chemical vapor deposition using $N_2$ additives and negative substrate bias at growth step. The microstructure of the films is controlled by changing $N_2$ gas ratio and negative bias. Defects and grain boundaries between diamond and graphite are proposed to be crucial factors for forming the conducting path of electron emissions. The effect of growth parameters on the film microstructure are investigated by Raman spectroscopy and scanning electron microscopy(SEM). Electron emission characteristics are also examined in terms of the film growth conditions.

  • PDF

테라헤르츠 영역에서의 BST 박막의 유전 특성 평가 (Terahertz dielectric characteristics of (Ba,Sr)$TiO_3$ thin films)

  • 조광환;강종윤;윤석진;이영백;맹인희;손주혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.28-28
    • /
    • 2007
  • Ferroelectric $(Ba_{0.5}Sr_{0.5})TiO_3$ (BST) thin films of thickness 500nm were deposited on $LaAlO_3$, (LAO) substrates by at $800^{\circ}C$. BST films were characterized for structure using X-ray diffraction (XRD). The surface morphology and thickness of BST the films were characterized by atomic force microscopy (AFM) and field emission scanning electron microscope (FESEM). We measured the dielectric properties at microwave frequencies (1~3 GHz) using a symmetrical stripline resonator with shorted ends and terahertz frequencies (0.2~2.5 THz) using a time-domain terahertz spectroscopy. The real and imaginary parts of the complex dielectric constant of the BST thin films on LAO substrates were in agreement with those previously reported.

  • PDF

글리터를 포함한 네일 에나멜 제품의 유해 금속 분석 (Determination of Hazardous Metals in Nail Enamel Containing Glitter)

  • 고숙경;정삼주;박영혜;박애숙;김현정;박건용;오영희
    • 한국환경보건학회지
    • /
    • 제43권2호
    • /
    • pp.103-110
    • /
    • 2017
  • Objectives: This study was performed to provide basic data for the re-establishment of standards (criteria) and analytical methods for hazardous metals in nail enamel. Methods: Ten metals (lead; Pb, arsenic; As, cadminum; Cd, antimony: Sb, cobalt; Co, nikel; Ni, copper; Cu, chromium; Cr, aluminum; Al, and mercury; Hg) were measured in 67 commercial nail enamels containing glitter and/or pearls. The content of hazardous metals (excepting Hg) was determined by using an inductively coupled plasma-optical emission spectrophotometer (ICP-OES) after microwave digestion. Mercury content was measured by a mercury analyzer without any preparation. Results: The detected ranges of the intact samples were as follows: $ND-1.756{\mu}g/g$ for Pb, $ND-1.24{\mu}g/g$ for As, ND for Cd, $ND-20.41{\mu}g/g$ for Sb, $ND-12.36{\mu}g/g$ for Co, $ND-7.908{\mu}g/g$ for Ni, $0.088-79.27{\mu}g/g$ for Cu, $0.281-18.54{\mu}g/g$ for Cr, $13.78-3563{\mu}g/g$ for Al, and $ND-0.044{\mu}g/g$ for Hg. After centrifugation, the detected ranges of supernatant were as follows: $ND-0.435{\mu}g/g$ for Pb, $ND-0.504{\mu}g/g$ for As, ND for Cd, $ND-0.035{\mu}g/g$ for Sb, $ND-13.17{\mu}g/g$ for Co, $ND-0.232{\mu}g/g$ for Ni, $0.117-90.07{\mu}g/g$ for Cu, $0.174-2.787{\mu}g/g$ for Cr, and $9.459-1565{\mu}g/g$ for Al. The results of this analysis showed that the levels of heavy metals such as Pb, As, and Sb were much higher in the intact samples than those of supernatant. Conclusion: In the present study, we found that the levels of hazardous metals were significantly different depending on the status of the presence of glitter. Based on the results, we recommend that the product consumer refrain from prolonged application of nail enamel, avoid biting or chewing the nails, and wear gloves during cooking and washing dishes.

지류 포장재 종류에 따른 중금속 함량 측정 (Determination of Heavy Metal Contents in Various Packaging Boards)

  • 김진우;서주환;윤혜정;이학래
    • 펄프종이기술
    • /
    • 제41권2호
    • /
    • pp.55-63
    • /
    • 2009
  • This study was performed to evaluate the heavy metal contents in various packaging board. Domestic and foreign OCC (old corrugated containers) and old duplex boards were used as raw materials. Tests were made for the printed and unprinted parts of the sample. Heavy metal contents of old food packaging boards made from virgin pulp fibers were also evaluated. The contents of heavy metals including lead (Pb), cadmium (Cd), barium (Ba), arsenic (As), antimony (Sb), selenium (Se), and mercury (Hg) were determined using ICP-AES (Inductively Coupled Plasma - Atomic Emission Spectrometer), and CV-AAS (Cold vapor-atomic absorption spectrometer) after digesting the samples in a microwave oven. The contents of heavy metals contained in domestic packaging board were higher than those in overseas samples, and OCC showed higher contents of heavy metals than old duplex boards. Printed parts gave greater heavy metal contents than unprinted parts. Results indicate that recycling of paper and paperboard products increases the heavy metal contamination of the paper packaging products and this derives mostly from the heavy metals contained in printing inks. Recycling processes that decrease heavy metals in recycled fibers and new printing inks that contains less heavy metals should be developed to solve the problem associated with the heavy metals in packaging paper products.

TRACING BRIGHT AND DARK SIDES OF THE UNIVERSE WITH X-RAY OBSERVATIONS

  • SUTO YASUSHI;YOSHIKAWA KOHJI;DOLAG KLAUS;SASAKI SHIN;YAMASAKI NORIKO Y.;OHASHI TAKAYA;MITSUDA KAZUHISA;TAWARA YUZURU;FUJIMOTO RYUICHI;FURUSHO TAE;FURUZAWA AKIHIRO;ISHIDA MANABU;ISHISAKI YOSHITAKA
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.387-392
    • /
    • 2004
  • X-ray observations of galaxy clusters have played an important role in cosmology, especially in determining the cosmological density parameter and the fluctuation amplitude. While they represent the bright side of the universe together with the other probes including the cosmic microwave background and the Type Ia supernovae, the resulting information clearly indicates that the universe is dominated by dark components. Even most of cosmic baryons turns out to be dark. In order to elucidate the nature of dark baryons, we propose a dedicated soft-X-ray mission, DIOS (Diffuse Intergalactic Oxygen Surveyor). Recent numerical simulations suggest that approximately 30 to 50 percent of total baryons at z = 0 take the form of the warm-hot intergalactic medium (WHIM) with $10^5K < T < 10^7K $which has evaded the direct detection so far. The unprecedented energy resolution (${\~} 2eV$) of the XSA (X-ray Spectrometer Array) on-board DIGS enables us to identify WHIM with gas temperature $T = 10^6 {\~} 10^7K$ and overdensity $\delta$ = 10 ${\~}$ 100 located at z < 0.3 through emission lines of OVII and OVIII. In addition, WHIMs surrounding nearby clusters are detectable with a typical exposure time of a day, and thus constitute realistic and promising targets for DIOS.

국내 유통 한약재의 중금속 함량 모니터링 -서울과 대구지역 한약재 중심으로 - (Monitoring of Heavy Metal Contents in Commercial Herbal Medicines in Korea: Cultivated Herbal Medicines in the Seoul and Daegu Areas)

  • 장설;이아름;이아영;최고야;김호경
    • 한국환경보건학회지
    • /
    • 제41권1호
    • /
    • pp.30-39
    • /
    • 2015
  • Objectives: This study was conducted to determine the heavy metal contents in commercial herbal medicines in Korea. Methods: Monitoring of lead, arsenic, cadmium and mercury was carried out on 116 samples of eleven types of herbal medicines. Among the total samples, 71 samples were domestic and 45 were imported. The samples were digested using the microwave method. The heavy metal contents were measured by inductively coupled plasma atomic emission spectrometry (ICP-AES) and a mercury analyzer. ICP-AES was used to analyze lead, arsenic cadmium. Mercury was analyzed by the amalgamation method. Results: The mean values of the heavy metal contents in the herbal medicines were Pb 0.64mg/kg, As 0.26mg/kg, Cd 0.07mg/kg and Hg 0.004mg/kg. Of the total samples, one violated the MFDS (Ministry of Food and Drug Safety) regulatory guidance on heavy metals in herbal medicines. Lead was detected at more than 5mg/kg in one sample. The measured values of arsenic, cadmium and mercury in the herbal medicines showed levels lower than the recommended levels for herbal medicines in MFDS regulatory guidance. In the comparison of domestic samples with imported herbal medicines, it was found that one domestic sample surpassed the maximum residue limits for lead. Conclusion: These results will be used to establish the regulation and control of heavy metal contents in herbal medicines. In addition, continuous monitoring is needed to ensure confidence in and the safety of these herbal medicines.

한국인 간장 및 신장피질에 함유된 카드뮴, 구리, 수은, 아연 함량과 메탈로치오나인과의 관계 (Relationships Between Cadmium, Copper, Mercury, Zinc Levels and Metallothionein in the Liver and Kidney Cortex of Korean)

  • 이상기;유영찬;윤여표;양자열;오승민;정규혁
    • Environmental Analysis Health and Toxicology
    • /
    • 제19권4호
    • /
    • pp.383-388
    • /
    • 2004
  • In order to elucidate the relationships between cadmium, copper, mercury, zinc levels and metallothionein in the liver and kidney cortex of Korean, the levels of Cd, Zn, Hg, Cu and metallothionein (MT) were determined in the kidney cortex and liver of 50 subjects deceased in the period of January-November, 2001 in the area of Seoul and Gyeonggi Province of Korea. The mean age of the population studied was 36.3+/-12.3 years. The tissues were digested with microwave digestion system and the elements were determined by inductively coupled plasma atomic emission spectrometry. MT was determined by the Cd-hemoglobin affinity assay. The determined levels (mean+/-SD) were: 33.9+/-18.9 micrograms Cd/g wet weight; 47.5+/-12.6 micrograms Zn/g wet weight; 2.5+/-0.57 microgram Cu/g wet weight; 0.26+/-0.31 micrograms Hg/g wet weight, 4.0+/-3.1 mg MT/g wet weight in renal cortex and 2.5+/-1.9 micrograms Cd/g wet weight; 46.9+/-15.0 micrograms Zn/g wet weight; 6.2+/-2.5 micrograms Cu/g wet weight; 0.10+/-0.15 micrograms Hg/g wet weight, 0.92+/-0.57 mg MT/g wet weight in the liver. Positive relationships between Cd and MT, sum of four divalent metal and MT in the kidney cortex were observed. No other correlation was found between Cu and MT, Hg and MT, Zn and MT in either organs.

지역농산물의 회분 및 무기질 함량 비교 (Comparison of Ash and Mineral Contents in Local Agricultural Products)

  • 지수현;강정화;조경숙;이선경;김행란;최용민;이유석
    • 한국식품영양학회지
    • /
    • 제29권6호
    • /
    • pp.1015-1022
    • /
    • 2016
  • The purpose of this study was to investigate ash and mineral contents of agricultural products that are widely and specifically grown in Korea, including 23 fruits, 11 cereals and specialty crops, and 11 leaves and vegetables. Pre-treatment of mineral was performed by microwave method. Mineral contents were analyzed by Inductively Coupled Plasma-Optical Emission Spectrometer (ICP-OES) and Inductively Coupled Plasma Spectrophotometry Mass (ICP-MS). Ash contents ranged from 0.20 to 0.69 g/100 g in fruits, 1.62 to 3.80 g/100 g in cereals, and 0.28 to 2.93 g/100 g in leaves and vegetables. Among the 45 samples, the highest contents of ash were found in quinoa (average 3.80 g/100 g), the highest contents of calcium (Ca) were found in Hansan ramie leaves (average 894.79 mg/100 g), the highest contents of phosphorus (P) were found in yellow amaranth(average 661.88 mg/100 g), the highest contents of potassium (K) were found in quinoa (average 1,455.38 mg/100 g), the highest contents of magnesium (Mg) were found in red amaranth (average 434.02 mg/100 g), the highest contents of molybdenum (Mo) were found in moringa (average $482.50{\mu}g/100g$), and the highest contents of selenium (Se) were found in apple mango(average $23.67{\mu}g/100g$).

Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

  • Yim, Yong-Hyeon;Park, Ji-Youn;Han, Myung-Sub;Park, Mi-Kyung;Kim, Byung-Joo;Lim, Young-Ran;Hwang, Eui-Jin;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.440-446
    • /
    • 2005
  • A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.