• 제목/요약/키워드: microwave emission

검색결과 158건 처리시간 0.028초

Fabrication of Transparent Ultra-thin Single-walled Carbon Nanotube Films for Field Emission Applications

  • Jang, Eun-Soo;Goak, Jung-Choon;Lee, Han-Sung;Kim, Myoung-Su;Lee, Nae-Sung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.353-353
    • /
    • 2008
  • Carbon nanotubes (CNTs) are attractive for field emitter because of their outstanding electrical, mechanical, and chemical properties. Several applications using CNTs as field emitters have been demonstrated such as field emission display (FED), backlight unit (BLU), and X-ray source. In this study, we fabricated a CNT cathode using transparent ultra-thin CNT film. First, CNT aqueous solution was prepared by ultrasonically dispersing purified single-walled carbon nanotubes (SWCNTs) in deionized water with sodium dodecyl sulfate (SDS). To obtain the CNT film, the CNT solution in a milliliter or even several tens of micro-litters was deposited onto a porous alumina membrane through vacuum filtration process. Thereafter, the alumina membrane was solvated by the 3 M NaOH solution and the floating CNT film was easily transferred to an indium-tin-oxide (ITO) glass substrate of $0.5\times0.5cm^2$ with a film mask. The transmittance of as-prepared ultra-thin CNT films measured by UV-Vis spectrophotometer was 68~97%, depending on the amount of CNTs dispersed in an aqueous solution. Roller activation, which is a essential process to improve the field emission characteristics of CNT films, increased the UV-Vis transmittance up to 93~98%. This study presents SEM morphology of CNT emitters and their field emission properties according to the concentration of CNTs in an aqueous solutions. Since the ultra-thin CNT emitters prepared from the solutions show a high peak current density of field emission comparable to that of the paste-base CNT emitters and do not contain outgassing sources such as organic binders, they are considered to be very promising for small-size-but-high-end applications including X-ray sources and microwave power amplifiers.

  • PDF

Electron Emission Properties of Selectively Grown Carbon Nanotubes for Electron Emitter in Microwave Power Amplifier

  • Han, Jae-Hee;Lee, Tae-Young;Kim, Do-Yoon;Yoo, Ji-Beom;Park, Chong-Yun;Choi, Jin-Ju;Jung, Tae-Won;Han, In-Taek;Kim, Jong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1021-1023
    • /
    • 2003
  • We studied field-emission characteristics of CNTs under various pre-treatment with $NH_{3}$ plasma on the substrate. The turn-on electric field is the lowest value and field enhancement factor (${\beta}$) is he highest value in CNTs pre-treated by $NH_3$ plasma (80 W and 5 min). The field-emission property of CNTs grown on the Ta substrate is slightly better than on the W substrate.

  • PDF

The Coexistence of OFDM-Based Systems Beyond 3G with Fixed Service Microwave Systems

  • Jo Han-Shin;Yoon Hyun-Goo;Lim Jae-Woo;Chung Woo-Ghee;Yook Jong-Gwan;Park Han-Kyu
    • Journal of Communications and Networks
    • /
    • 제8권2호
    • /
    • pp.187-193
    • /
    • 2006
  • In this paper, we study the coexistence of orthogonal frequency division multiplexing (OFDM)-based systems beyond 3G (B3G) and point-to-point (P-P) fixed service (FS) microwave systems. The advanced general analytical model derived via a power spectral density (PSD) analysis proposed in this paper has two advantages in comparison with the conventional minimum coupling loss (MCL) method. First, the interfering signal power that appears in the band of a victim system can be easily assessed without a spectrum emission mask. Second, when transmit power is not allocated to some subcarriers overlapping the band of the victim system in order to mitigate B3G OFDM-based systems interference with other systems, the general analytical model can successfully assess the interference from the B3G systems into FS systems, whereas the MCL method incorporating the spectrum emission mask cannot be applied in the presence of the same interference condition. The proposed model can be derived in a closed form and is simply implemented with the help of simulation, and thus the solution can be obtained in significantly reduced time. Through application of the proposed model, coexistence results are analyzed in a co-channel and adjacent channel with respect to guard band and minimum separation distance.

백금족 금속과 규산염을 포함하는 모노리스형 자동차 폐촉매의 ICP-AES 분석을 위한 극초단파 분해 전처리 기법의 응용 (Application of Microwave Digestion Pretreatment Techniques for ICP-AES Analysis of Used Monolithic Automobile Catalysts Having Platinum Group-Metals and Silicates)

  • 김충현;우성일;진성환
    • 공업화학
    • /
    • 제10권4호
    • /
    • pp.568-575
    • /
    • 1999
  • 백금족 금소과 규산염을 포함하는 자동차 폐촉매 내의 백금족 금속과 주요 성분들을 ICP-AES로 동시에 분석하기 위한 두 종류의 전처리 방법이 비교되었다. HF, $HNO_3$, HCl, $HClO_4$, $H_2O_2$, 및 $H_3BO_3$ 등의 혼합산의 다양한 조합을 사용하여 열판(hot plate) 용해법과 밀폐용기를 사용하는 극초단파(microwave) 가압-가열법을 비교 검토하였다. 전통적인 열판 용해법보다 밀폐용기를 사용한 극초단파 가압-가열법이 화수율, 분석시간 및 사용하는 양 등의 측면에서 상대적으로 우수한 결과를 나타내었고, 0.25 g의 폐촉매 시료에 대하여 HF 2 mL, $HNO_3$2 mL, 그리고 HCl 6 mL를 사용하여 200 psi(13.79 bar), $180^{\circ}C$ 조건에서 1시간 동안 가열한 후, 5% (w/v) $H_3BO_3$ 16 mL를 사용하여 20 psi(1.38 bar), $100^{\circ}C$ 조건에서 10분간 가열한 다음, 왕수 10 mL로 열판에서 두 번 반복하여 처리하는 것이 백금족 금속의 회수율 측면에서 가장 좋은 결과를 가져왔고(XRF 분석 대비 85~110%), 이 방법은 2% 이내의 상대 표준 편차를 보임으로써, 자동차 폐촉매의 일상적인 분석기법으로서의 충분한 가능성을 보였다.

  • PDF

마이크로파 플라즈마의 광방출 스펙트럼 (optical emission spectra of microwave plasma)

  • 박상현;구효근;심정봉;김경환;박재윤;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.895-897
    • /
    • 1998
  • The optical spectra of microwave plasma by four kinds of gases($N_2$, $N_2-CH_4$, $H_{2}-CH_{4}$ and Air-$CH_4$) have been measured for investigating 388.4[nm] peak which has the same intensity as $H_{\alpha}$(656.4[nm]) peak. A 388.4[nm] peak by $N_2$ plasma, $N_{2}-CH_{4}$ plasma and Air-$CH_4$ plasma may be CN peak because it is with 337.1, 357.8 and 316.0[nm] peaks by $N_2$. And a 388.4[nm] peak by $H_{2}-CH_{4}$ plasma without by $N_2$ 337.1, 357.8 and 316.0[nm] peaks may be CH peak. In the investigation results for optical spectra by $H_{2}-CH_{4}$ plasma and $H_{2}-CH_{4}-O_{2}$ plasma, the density of hydrogen atom was increased because oxygen decompose hydrogen molecules in $H_{2}-CH_{4}$ plasma with oxygen. These hydrogen atom decompose $CH_4$ and increase CH radical. And the crystalline of deposited diamond was good and the growth rate increased.

  • PDF

실리콘고무형과 전자기파에 의한 PDP격벽의 성형에 관한 연구 (A Study on Plasma Display Panel Barrier Rib Fabrication by Silicone Rubber Tooling and electromagnetic Wave)

  • 정해도;손재혁;조인호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.20-23
    • /
    • 2001
  • Plasma Display Panel(PDP) is a type of flat panel display utilizing the light emission produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalks from adjacent sub-pixels. The mold for forming the barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing processes such as screen printing, sand-blasting and photosensitive glass methods. The mold for PDP barrier ribs have stripes of micro grooves transferring glass-material wall. In this paper, Stripes of grooves of which width 48${\mu}{\textrm}{m}$, depth 124$\mu\textrm{m}$ , pitch 274$\mu\textrm{m}$ was acquired by machining of single crystal silicon with dicing saw blade. Maximum roughness of the bottom of the grooves was 59.6nm Ra in grooving Si. Barrier ribs were formed with silicone rubber mold, which is transferred from grooved Si forming hard mold. Silicone rubber mold has the elasticity, which enable to accommodate the waveness of lower glass plate of PDP. The methods assisted by the microwave and UV was adopted for reducing the forming time of glass paste.

  • PDF

초고압초음파분해법을 이용한 축산물내 미량금속 잔류분석을 위한 시료전처리 방법 (A Study on Sample Preparation for the Analysis of Trace Elements in Foods of Animal Origin by Ultra High Pressure Microwave Digestion)

  • 이명헌;이희수;손성완;정갑수;박종명;김상근
    • 대한수의학회지
    • /
    • 제43권3호
    • /
    • pp.393-398
    • /
    • 2003
  • Simple and rapid sample preparation method for trace elements in foods of animal origin using ultra high pressure microwave digestion system (UHP/MDS) and inductively coupled plasma atomic emission spectrometer (ICP/AES) were developed. 1. For the digestion of sample using UHP-MDS, 20% nitric acid (v/v) was the most suitable solvent for the determination of trace elements in foods of animal origin. 2. The optimal digestion conditions for UHP-MDS were as follows: final temperature $180^{\circ}C$, final pressure 400 PSI, and magnetic power 900 W in the solid sample. For the liquid sample final temperature $170^{\circ}C$, final pressure 300 PSI and magnetic power 700 W were optimal conditions. 3. As result of interlaboratory test, the average recovery rate of the for solid sample were 88.3~99.1% for As, 82.4~93.3% for Cd, 89.2~101.2% for Hg and 86.5~93.8% for Pb, respectively. In liquid sample, it were 87.0~96.8% for As, 80.9~96.6% for Cd, 87.5~91.2% for Hg and 91.4~95.5% for Pb, respectively. 4. The average coefficient variation rate were 3.3~15.9% for solid sample and 2.9~10.8% for liquid sample.

PVC 여과지를 이용한 금속 분석방법에 대한 정확도와 정밀도 평가 (Evaluation of Accuracy and Precision of Analysis of Metals with Polyvinyl Chloride Membrane Filters)

  • 변성욱;최상준
    • 한국산업보건학회지
    • /
    • 제26권1호
    • /
    • pp.48-57
    • /
    • 2016
  • Objectives: This study was conducted to evaluate the accuracy and precision of airborne metal analysis using polyvinyl chloride(PVC) membrane filter by pretreatment methods. Methods: A total of 75 spiked PVC samples for Cr, Fe and Mn ranged from 6 ug/sample to 40 ug/sample were used to evaluate recovery rates for three pretreatment methods: acid extraction, hot plate ashing and microwave digestion. For Mn, an additional 75 spiked mixed cellulose ester(MCE) membrane filters were analysed to compare the recovery rates of PVC samples. All samples were analysed with an inductively coupled plasma optical emission spectrometer(ICP-OES) and manganese samples were additionally analyzed by atomic absorption spectrometer(AAS). Results: The overall mean recovery rates of PVC samples for Cr, Fe and Mn were 90% or higher regardless of pretreatment methods, but there were statistically significant differences in recovery rates for Cr(p<0.05) and Mn(p<0.01) samples by pretreatment methods. The biases and the coefficient variations of PVC samples for three metals pretreated with three kinds of pretreatment methods ranged from 1.7% to 4.7% and from 1.6% to 6.5%, respectively. The manganese PVC samples pretreated by microwave digestion and analyzed with ICP-OES had the lowest bias at 1.9% and also showed lower bias than the bias for MCE samples, 2.7%. Conclusions: In order to accurately analyze the metals sampled with PVC membrane filters, microwave digestion and ICP-OES can be recommended.

Fabrication of carbon nanotube fibers with nanoscale tips and their field emission properties

  • Shin, Dong-Hoon;Song, Ye-Nan;Sun, Yu-Ning;Shin, Ji-Hong;Lee, Cheol-Jin
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.468-468
    • /
    • 2011
  • Carbon nanotubes (CNTs) have been considered as one of the promising candidate for next-generation field emitters because of their unique properties, such as high field enhancement factor, good mechanical strength, and excellent chemical stability. So far, a lot of researchers have been interested in field emission properties of CNT itself. However, it is necessary to study proper field emitter shapes, as well as the fundamental properties of CNTs, to apply CNTs to real devices. For example, specific applications, such as x-ray sources, e-beam sources, and microwave amplifiers, need to get a focused electron beam from the field emitters. If we use planar-typed CNT emitters, it will need several focal lenses to reduce a size of electron beam. On the other hand, the point-typed CNT emitters can be an effective way to get a focused electron beam using a simple technique. Here, we introduce a fabrication of CNT fibers with nanoscale point tips which can be used as a point-typed emitter. The emitter made by the CNT fibers showed very low turn-on electric field, high current density, and large enhancement factor. In addition, it showed stable emission current during long operation period. The high performance of CNT point emitter indicated the potential e-beam source candidate for the applications requiring small electron beam size.

  • PDF

ICP-AES로 바나듐 측정을 위한 마이크로파 용해 장치를 이용한 오산화바나듐 용해 (Dissolution of vanadium pentoxide using microwave digestion system for determination of vanadium by ICP-AES)

  • 최광순;박양순;김연희;한선호;송규석
    • 분석과학
    • /
    • 제23권6호
    • /
    • pp.511-517
    • /
    • 2010
  • 황산 제조 및 그 외에 많은 유기화합물을 산화시키는 촉매제로 널리 이용되고 있는 공업용 오산화바나듐의 용해방법을 연구하였다. 오산화바나듐 시약은 왕수-$H_2O_2$-HF로 완전히 용해되었으나 판상 모양의 오산화바나듐 시료는 혼합산에 완전히 용해되지 않아 시료 전처리 방법을 확립할 필요가 있다. 따라서 본 연구에서는 산 처리법과 용융법을 혼용한 방법 및 마이크로파 용해 장치를 이용한 용해법을 비교 분석하여 바나듐화합물의 용해성을 조사하였다. 바나듐 화합물은 왕수, 플루오르화수소산 및 과산화수소의 혼합산으로 녹이는 것이 최적이었으며, 두 용해 방법 중 마이크로파 용해 장치를 이용한 용해법이 분석의 신속성을 고려하면 보다 유용한 방법으로 판단되었다. 마이크로파 용해 장치로 용해한 다음 유도 결합 플라스마 원자방출분광법으로 측정한 결과 바나듐산화물($V_2O_5$) 함량은 $97.9{\pm}0.9%$이었다.