• 제목/요약/키워드: microstructure observation

검색결과 380건 처리시간 0.027초

치과용 아말감합금 및 아말감의 마세구조에 관한 연구 (A STUDY ON THE MICROSTRUCTURES OF THE AMALGAM ALLOYS AND AMALGAMS)

  • 연상흠;이정식;이명종;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.87-105
    • /
    • 1996
  • The purpose of this study is to investigate the characteristics of the compositions and phases of amalgam alloys and amalgams by using EMPA and X-ray diffractometer. Each specimen was made from Caulk Fine Cut Clow copper lathe cut amalgam), Caulk Spherical (low copper spherical amalgam), Tytin (high copper unicorn position amalgam), Dispersally (high copper admixed amalgam) and Valiant (Palladium enriched amalgam). For preparing amalgam alloys, Tytin and Valiant were used as powder forms and the others were used as tablet forms after being polished with polishing machine. For preparing amalgams, each amalgam alloy and Hg were measured, and triturated by mechanical amalgamater according to user's instructions. After triturating, the triturated mass was inserted to cylindrical metal mold and simultaneously adapted by cylindrical condenser with same diameter and condensed by Instron universal testing machine with 80kg pressure & 1mm/min speed. Each specimen was removed from the metal mold and stored at room temperature for a week. The specimen was polished with the same polishing machine for amalgam alloy. For observation of microstructure and analysis of composition of amalgam alloys and amalgams, EMPA was used to get secondary electron images, backscattered images and characteristic X-ray images of Ag, Sn, Cu, Zn, Hg. To analyze compositions of amalgam alloys and amalgams, X-ray diffractometer was used. Amalgam alloys were scanned at the range of 2${\theta}$ of 30-$85^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line and amalgams were scanned at the range of 2${\theta}$ of 28-$44^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line. By comparing obtained d(distance between surfaces) and d of expected phases and atoms in amalgam alloys and amalgams in ASTM card, phases and atoms were identified. The results were as follows, 1. In Caulk Fine Cut amalgam alloy typical ${\gamma}$ phase was shown, and in amalgam, ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phases were observed. 2. In Caulk Spherical amalgam alloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, ${\gamma}_2$ and $\eta$ phases were observed. 3. In Tytin amalgam alloy ${\gamma}$, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 4. In Dispersalloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 5. In Valiant alloy ${\gamma}$, Cu and e phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed.

  • PDF

나노 실리카 하이브리드 박막의 산소 투과 특성 (Oxygen Permeation Characteristics of Nano-silica Hybrid Thin Films)

  • 김성우
    • 한국응용과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.174-181
    • /
    • 2007
  • 본 연구에서는 졸-겔 공법을 이용하여 가스 차단 특성을 갖는 $SiO_2/EVOH$(에틸렌 비닐알콜 공중합체) 하이브리드 물질을 제조하였다. 제조된 여러 조성의 하이브리드 졸을 표면 처리한 biaxially oriented polypropylene (BOPP) 기지재에 스핀 코팅 방식을 이용하여 코팅하였다. X선 회절 및 DSC 분석에 의해 하이브리드 내의 EVOH 상과 실리카 상 사이의 결합에 따른 결정화 거동의 변화를 조사하였다. 또한 $SiO_2/EVOH$ 하이브리드 겔의 모폴로지 관찰을 통하여, 100nm 이하의 실리카 입자들이 균열하게 분산된 매우 치밀한 상 미세구조를 갖는 하이브리드 물질을 제조하기 위해 필요한 Tetraethylorthosilicate (TEOS) 무기전구체의 최적 함량이 존재함을 알 수 있었다. 첨가된 TEOS 함량이 최적 함량보다 낮거나 높은 경우에는 큰 도메인의 입자 클러스터들이 형성되어 매우 불안정한 모폴로지를 나타내는 상분리 현상이 관찰되었다. 이러한 모폴로지 결과는 하이브리드 코팅 필름의 산소 투과도의 변화 결과와 일치하였는데, TEOS 함량이 0.01 - 0.02mol로 첨가되어 제조된 하이브리드로 코팅된 필름의 경우 매우 우수한 산소 차단 특성을 나타냈으며, 0.04mol 이상으로 첨가되었을 때는 상 분리 및 미세 균열 발생으로 인하여 그 차단 특성이 급격하게 감소하는 것으로 나타났다.

The Effect of Transverse Magnetic field on Macrosegregation in vertical Bridgman Crystal Growth of Te doped InSb

  • Lee, Geun-Hee;Lee, Zin-Hyoung
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1996년도 The 9th KACG Technical Annual Meeting and the 3rd Korea-Japan EMGS (Electronic Materials Growth Symposium)
    • /
    • pp.522-522
    • /
    • 1996
  • An investigation of the effects of transverse magnetic field and Peltier effect on melt convection and macrosegregation in vertical Bridgman crystal grosth of Te doped InSb was been carried out by means of microstructure observation, Hall measurement, electrical resistivity measurement and X-ray analysis. Before the experiments, Interface stability, convective instability and suppression of convection by magnetic field were calculated theoretically. After doping 1018, 1019 cm-3 Te in InSb, the temperature of Bridgman furnace was set up at $650^{\circ}C$. The samples were grown in I.D. 11mm, 100mm high quartz tube. The velocity of growth was about 2${\mu}{\textrm}{m}$/sec. In order to obtain the suppression of convection by magnetic field in the middle of growth, 2-4KG magnetic field was set on the melt. For searching of the shape of solid-liquid interface and the actual velocity of crystal growth, let 2A current flow from solid to liquid for 1second every 50seconds repeatedly (Peltier effect). The grown InSb was polycrystal, and each grain was very sharp. There was no much difference between the sample with and without magnetic field at a point of view of microstructure. For the sample with Peltier effect, the Peltier marks(striation) were observed regularly as expected. Through these marks, it was found that the solid-liquid interface was flat and the actual growth velocity was about 1-2${\mu}{\textrm}{m}$/sec. On the ground of theoretical calculation, there is thermosolutal convection in the Te doped InSb melt without magnetic field in this growth condition. and if there is more than 1KG magnetic field, the convection is suppressed. Through this experiments, the effective distribution coefficients, koff, were 0.35 in the case of no magnetic field, and 0.45 when the magnetic field is 2KG, 0.7 at 4KG. It was found that the more magnetic field was applied, the more convection was suppressed. But there was some difference between the theoretical calculation and the experiment, the cause of the difference was thought due to the use of some approximated values in theoretical calculation. In addition to these results, the sample with Peltier effect showed unexpected result about the Te distribution in InSb. It looked like no convection and no macrosegregation. It was thought that the unexpected behavior was due to Peltier mark. that is, when the strong current flew the growing sample, the mark was formed by catching Te. As a result of the phenomena, the more Te containing thin layer was made. The layer ruled the Hall measurement. The values of resistivity and mobility of these samples were just a little than those of other reference. It was thought that the reason of this result was that these samples were due to polycrystal, that is, grain boundaries had an influence on this result.

  • PDF

Effect of Intermittent Parathyroid Hormone Administration on the Microstructure of Jaw Bone in the Ovariectomized Rats

  • Kang, Kang-su;Kim, Kun-hyoung;Heo, Hyun-a;Park, Suhyun;Pyo, Sung-woon
    • Journal of Korean Dental Science
    • /
    • 제8권2호
    • /
    • pp.65-73
    • /
    • 2015
  • Purpose: Parathyroid hormone (PTH) therapy has drawn attention, as an alternative to anti-resorptive drugs since PTH accelerates bone density by anabolic action. The purpose of this study was to identify the effect of intermittent PTH administration on jaw bones of rat undergone bilateral ovariectomy. Materials and Methods: Nine female Sprague-Dawley rats were divided into three groups. PTH group was ovariectomized (OVX) to induce osteoporosis and PTH $30{\mu}g/kg$ was administered 1 week after the surgery. In OVX group, ovariectomy was performed and only vehicle was administered by subcutaneous injection 3 times per week. Control group was subjected to sham surgery. The animals were sacrificed 8 weeks after the surgery and specimens were obtained from ilium and upper and lower jaw bones. Histological investigation was carried out by using an optical microscope and micro-computed tomography was taken to examine structural property changes in each bone sample. Result: In the ilium, the bone volume ratio (bone volume/total volume, BV/TV) of PTH, OVX and control groups was $53.75%{\pm}7.57%$, $50.61%{\pm}12.89%$, $76.20%{\pm}5.92%$ (P=0.061) and bone mineral density (BMD) was $1.12{\pm}0.09$, $0.88{\pm}0.48$, $1.38{\pm}0.07g/cm^3$ (P=0.061). In the mandible, BV/TV of PTH, OVX and control groups was $64.60%{\pm}12.17%$, $58.26%{\pm}9.63%$, $67.54%{\pm}14.74%$(P=0.670) and BMD was $1.21{\pm}0.17$, $1.19{\pm}0.13$, $1.27{\pm}0.18g/cm^3$ (P=0.587). In the maxilla, BV/TV of PTH, OVX and control groups was $61.19%{\pm}8.92%$, $52.50%{\pm}11.22%$, $64.60%{\pm}12.17%$ (P=0.430) and BMD was $1.20{\pm}0.11$, $1.11{\pm}0.16$, $1.21{\pm}0.17g/cm^3$ (P=0.561). No statistically significant difference was found in any variables in all groups. Histological observation revealed that the ilium in OVX group demonstrated sparsely formed trabecular bones compared with other groups. However, upper and lower trabecular bones did not present significant differences. Conclusion: Intermittent administration of PTH appears to affect the microstructure of rat jaw bones, but statistical significance was not found. However, the measurements in this study partly implicated the possible anabolic effect of PTH in vivo.

염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구 (Scanning Electron Microscopic Study of the Effect of Tetracycline-HCl on the Change of Implant Surface Microstructure according to Application Time)

  • 김우영;이만섭;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.523-537
    • /
    • 2002
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used. Implant surface was rubbed with 5Omg/ml tetracycline - HCl solution for ${\frac}{1}{2}$ min., 1 min., $1{\frac}{1}{2}$ min., 2 min., and 3min. respectively in the test group and with no conditioning in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. subsequently, the acid-etching process crated the micro roughness, which thus was superimposed on the macro roughness. 3. In the SLA surfaces, irrespective of the application time of 50mg/ml tetracycline-HCl solution, in general, test specimens were similar to control. 4. In the $TiO_2blasted$ surfaces the control specimen showed the rough surface with small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline-HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCl solution. And the $TiO_2blasted$ surfaces conditioned with tetracycline - HCl solution began to be changed from $1{\frac}{1}{2}$ min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.

Cu-7Al-2.5Si 합금의 기계적 및 내식특성에 미치는 열처리 효과 (Effect of the Heat Treatment on the Mechanical Property and Corrosion Resistance of CU - 7Al - 2.5Si Alloy)

  • 이성열;원종필;박동현;문경만;이명훈;정진아;백태실
    • Corrosion Science and Technology
    • /
    • 제13권1호
    • /
    • pp.28-35
    • /
    • 2014
  • Recently, the fuel oil of diesel engines of marine ships has been increasingly changed to heavy oil of low quality as the oil price is getting higher and higher. Therefore, the spiral gear attached at the motor of the oil purifier which plays an important role to purify the heavy oil is also easy to expose at severe environmental condition due to the purification of the heavy oil in higher temperature. Thus, the material of the spiral gear requires a better mechanical strength, wear and corrosion resistance. In this study, the heat treatment(tempering) with various holding time at temperature of $500^{\circ}C$ was carried out to the alloy of Cu-7Al-2.5Si as centrifugal casting, and the properties of both hardness and corrosion resistance with and without heat treatment were investigated with observation of the microstructure and with electrochemical methods, such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram, and a.c. impedance. in natural seawater solution. The ${\alpha}$, ${\beta}^{\prime}$ and ${\gamma}_2$ phases were observed in the material in spite of no heat treatment due to quenching effect of a spin mold. However, their phases, that is, ${\beta}^{\prime}$ and ${\gamma}_2$ phases decreased gradually with increasing the holding time at a constant temperature of $500^{\circ}C$. The hardness more or less decreased with heat treatment, however its corrosion resistance was improved with the heat treatment. Furthermore, the longer holding time, the better corrosion resistance. In addition, when the holding time was 48hrs, its corrosion current density showed the lowest value. The pattern of corroded surface was nearly similar to that of the pitting corrosion, and this morphology was greatly observed in the case of no heat treatment. It is considered that ${\gamma}_2$ phase at the grain boundary was corroded preferentially as an anode. However, the pattern of general corrosion exhibited increasingly due to decreasing the ${\gamma}_2$ phase with heat treatment. Consequently, it is suggested that the corrosion resistance of Cu-7Al-2.5Si alloy can be improved with the heat treatment as a holding time for 48 hrs at $500^{\circ}C$.

폴리카보네이트 임시수복재료의 물성 평가 (Evaluation of physical properties of polycarbonate temporary restoration materials)

  • 김광윤;곽영훈;김희중
    • 구강회복응용과학지
    • /
    • 제36권3호
    • /
    • pp.168-175
    • /
    • 2020
  • 목적: 현재 상용화하여 사용되는 임시 수복물 재료와 새롭게 대두되는 재료들의 기계적 성질을 실험하고, 평가하는 것이다. 연구 재료 및 방법: Polymethyl methacrylate (PMMA) 2종, polyetheretherketone (PEEK), polycarbonate 4군의 고분자 재료들을 평가하였고, 표면 경도, 굴곡강도, 저작 시 마모도, 마모 양상 4가지의 기계적 물성을 실험하였다. 시편의 3축 굽힘 강도와 비커스 경도 테스트는 각각 만능 시험기를 사용하여 측정하였고, 저작 시험기를 이용하여 100,000회의 저작 시험 후 주사 전자 현미경으로 미세구조를 관찰하고 전, 후 무게를 비교하였다. 통계적 유의성 평가를 위해 kruskal wallis test를 시행하였다. 결과: PEEK의 굽힘 강도와 비커스 경도가 가장 높게 나타났으며, PC, PMMA-H, PMMA-T 순으로 나타났다. 미세구조 표면은 PEEK 군에서 거칠기 형태가 가장 적게 나타났으며, PC, PMMA-H, PMMA-T 순으로 적게 나타났다. 결론: PC는 임시치아 제작에 적용할 수 있는 충분한 기계적 성질을 가진 것으로 사료된다. 그러나, 실제 임상 적용을 위해서는 생체 친화성과 같은 추가적인 연구가 필요할 것으로 사료된다.

경남 두동리가마터 출토 경질과 연질백자에 대한 물성 및 원료 분석 (The Analysis of Physical Characteristics and Raw Materials on Hard and Soft Whiteware at Excavated Kiln in Dudong-ri Gyeongsangnam-do, Korea)

  • 고민정;김지태;고경신;김규호
    • 보존과학회지
    • /
    • 제18권
    • /
    • pp.75-88
    • /
    • 2006
  • 경상남도 진해시 두동리가마터 출토 백자를 중심으로 물리 화학적 분석, 미세구조관찰을 실시하여 경질과 연질백자의 특성을 과학적으로 고찰해보았다. 물리적 특성은 연질백자가 높은 흡수율과 기공률을 갖는 것을 확인하였다. 화학적 조성은 태토와 유약의 지역적 특성은 나타났으나 경질과 연질의 구분은 확인되지 않았다. 미세구조는 물리적 특성으로 확인되는 경질과 연질의 차이를 가시적으로 확인할 수 있다. 경질백자는 기공의 형태가 둥글고 유리질화된 장석과 같은 광물이 관찰되나 연질백자는 기공도 부정형으로 분포정도가 매우 크며 유리질화된 입자를 확인할 수 없다. 이와같은 분석 결과에서 두동리의 경질과 연질백자는 화학적 조성 및 번조조건에 따라 나타나는 차이보다는 물리적 특성이 크게 좌우하는 것으로 확인된다. 그러나 물리적 특성에 따른 사용 원료는 제작된 지역에 따라 가마별로 차이를 보일 수 있으므로 다양한 비교 연구가 필요하다.

  • PDF

INFLUENCE OF BASALT FIBRES ON THE PROPERTIES OF FLY ASH BASED GEOPOLYMER BINDER

  • Temuujin, J.;Minjigmaa, A.;Davaabal, B.;Darkhijav, B.;Ruescher, C.H.
    • 한국입자에어로졸학회지
    • /
    • 제12권2호
    • /
    • pp.43-50
    • /
    • 2016
  • The influence of basalt fibres on the compressive strength of the geopolymer type binders has been studied. For the experiments 2 types of the basalt fibres were used, namely chopped and spooled fibres. Both types of basalt fibres were 7-10 micron thick in diameter and cut into pieces of 6 mm length. The fibres were mixed with 1% weight to the fly ash powder, followed by the addition of the activator solution (8M NaOH). The pastes obtained were cured at $70^{\circ}C$ for 20 h revealing compact bodies. Compressive strength was measured after 7 days and microstructure observation performed with SEM. The cube bodies ($2{\times}2{\times}2cm$) reveal compressive strength of 47.25(4.03) MPa, while it decreased to 34.0(9.05) MPa in spooled basalt fibres and to 17.33(5.86) MPa in the chopped basalt fibres containing binder, i.e 76% and 36% of the strength without fibres, respectively. The much weaker compressive strength of the chopped fibres containing binder is related to the absence of significant adhesion between the geopolymer binder and the basalt fibres, forming voids instead. Alkali leaching effect of basalt fibres could probably explain the drop in the compressive strength with spooled and chopped fibres, respectively.

산화 티타늄 블라스팅 임프란트 표면구조에 대한 염산 테트라싸이클린의 영향 (Micromorphometric change of Ti$O_2$ blast implant surface conditioned with tetracycline-HCI)

  • 이정민;허익;권영혁;박준봉;정종혁;허성주
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.599-611
    • /
    • 2007
  • The present study was performed to evaluate the surface roughness and effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. Ti$O_2$ surface Implant was utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution for 0.5min, 1min, 1.5min, 2min, 2.5min and 3min respectively in the Tetracycline-HCI group. Then, specimens were measured surface roughness and processed for scanning electron microscopic observation. The results of this study were as follows. 1. Ti$O_2$ blast implant surface showed increased surface roughness 1.5 minute after treatment with Tetracycline-HCI. But, there were not significant differences in saline group after treatment. 2. Tetracycline-HCI group showed changed surface micro-morphology in SEM after 1.5 minute. There were not significant differences in saline group after treatment. 3. Between Tetracycline-HCI group and saline group, there were difference in surface roughness change and SEM micro-morphology. Tetracycline-HCI have influence on Ti$O_2$ blast implant surface. In conclusion, the detoxification with 50mg/ml Tetracycline-HCI must be applied respectively with different time according to various implant surfaces.