• Title/Summary/Keyword: microDiamond 검출기

Search Result 2, Processing Time 0.014 seconds

Feasibility Study of the microDiamond Detector for Measurement of Small Field Photon Beam (광자선 소조사면 선량측정을 위한 microDiamond 검출기의 유용성 고찰)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Ji, Young Hoon;Kim, Kum Bae;Lee, Sang Hoon;Min, Chul Kee;Jo, Gwang Hwan;Shin, Dong Oh;Kim, Seong Hoon;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.255-263
    • /
    • 2014
  • The dosimetry of very small fields is challenging for several reasons including a lack of lateral electronic equilibrium, large dose gradients, and the size of detector in respect to the field size. The objective of this work was to evaluate the suitability of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the small field dosimetry in cyberknife photon beams of 6 different collimator size (from 5 mm to 30 mm). Measurements included dose linearity, dose rate dependence, output factors (OF), percentage depth doses (PDD) and off center ratio (OCR). The results were compared to those of pinpoint ionization chamber, diamond detector, microLion liquid Ionization chamber and diode detector. The dose linearity results for the microDiamond detector showed good linearly proportional to dose. The microDiamond detector showed little dose rate dependency throughout the range of 100~600 MU/min, while microLion liquid Ionization chamber showed a significant discrepancy of approximately 5.8%. The OF measured with microDiamond detector agreed within 3.8% with those measured with diode. PDD curves measured with silicon diode and diamond detector agreed well for all the field sizes. In particular, slightly sharper penumbras are obtained by the microDiamond detector, indicating a good spatial resolution. The results obtained confirm that the new PTW 60019 microDiamond detector is suitable candidate for application in small radiation fields dosimetry.

Assessment of Dosimetric Leaf Gap According to Measuring Active Volume of Detector (검출기 측정 용적에 따른 Dosimetric Leaf Gap 변화와 정확성 검증에 대한 연구)

  • Dae-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.863-870
    • /
    • 2022
  • DLG (Dosimetric Leaf Gap) and transmission factor are important parameters of MLC modeling in treatment planning system. In this study, DLG and transmission factor of HD-MLC were measured using detector with different measuring volumes, and the accuracy of the treatment plans was evaluated according to the DLG values. DLG was measured using the dynamic sweeping gap method with Semiflux3D and MicroDiamond detectors. Then, 10 radiation treatment plans were generated to optimize the DLG value and compared with the measurement results. Photon energies 6, 8, 10 MV, the DLG measured by Semiflux3D were 0.76, 0.83, and 0.85 mm, and DLG measured by MicroDiamond were 0.78, 0.86, and 0.9 mm. All plans were measured by portal dosimetry and analyzed using Gamma Evaluation. In the 6 MV photon beams, the average gamma passing rate were 94.3% and 98.4% for DLG 0.78 mm and 1.15 mm. In the 10 MV photon beam, the average gamma passing rate were 91.2% and 97.6% for DLG 0.9 mm and 1.25 mm. HD-MLC needs accurate modeling in the treatment planning system. DLG could be used measured data using small volume detector. However, for better radiation therapy, DLG should be optimized at the commissioning stage of LINAC.