• Title/Summary/Keyword: micro-CT

Search Result 424, Processing Time 0.027 seconds

Effect of the masseter muscle injection of botulinum toxin A on the mandibular bone growth of developmental rats

  • Seok, Hyun;Kim, Seong-Gon;Kim, Min-Keun;Jang, Insan;Ahn, Janghoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.5.1-5.8
    • /
    • 2018
  • Background: The objective of this study was to evaluate the influence of masticatory muscle injection of botulinum toxin type A (BTX-A) on the growth of the mandibular bone in vivo. Methods: Eleven Sprague-Dawley rats were used, and BTX-A (n = 6) or saline (n = 5) was injected at 13 days of age. All injections were given to the right masseter muscle, and the BTX-A dose was 0.5 units. All of the rats were euthanized at 60 days of age. The skulls of the rats were separated and fixed with 10% formalin for micro-computed tomography (micro-CT) analysis. Results: The anthropometric analysis found that the ramus heights and bigonial widths of the BTX-A-injected group were significantly smaller than those of the saline-injected group (P < 0.05), and the mandibular plane angle of the BTX-A-injected group was significantly greater than in the saline-injected group (P < 0.001). In the BTX-A-injected group, the ramus heights II and III and the mandibular plane angles I and II showed significant differences between the injected and non-injected sides (P < 0.05). The BTX-A-injected side of the mandible in the masseter group showed significantly lower mandibular bone growth compared with the non-injected side. Conclusion: BTX-A injection into the masseter muscle influences mandibular bone growth.

The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut

  • Guleryuz, Aysegul;Korkmaz, Cumhur;Sener, Ayse;Tas, Mehmet Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.304-315
    • /
    • 2021
  • PURPOSE. Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS. PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 - 55℃). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS. The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P* = .016, P* = .042, P < .001, respectively). CONCLUSION. Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.

Polydopamine-mediated surface modifications of poly ʟ-lactic acid with hydroxyapatite, heparin and bone morphogenetic protein-2 and their effects on osseointegration

  • Yun, Young Jin;Kim, Han-Jun;Lee, Deok-Won;Um, Sewook;Chun, Heung Jae
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.244-254
    • /
    • 2018
  • Surface modified poly ${\text\tiny{L}}$-lactic acid (PLLA) samples with hydroxyapatite (HA), heparin and bone morphogenetic protein-2 (BMP-2) mediated by polydopamine (pDA) coating (PLLA/pDA/HA/Hep/BMP-2) were prepared, and their effects on the enhancements of bone formation and osseointegration were evaluated in vitro and in vivo as compared to PLLA, PLLA/pDA/HA, and PLLA/pDA/Hep/BMP-2. The changes in surface chemical compositions, morphologies and wettabilities were observed by X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (FE-SEM), atomic force microscopy (AFM) and water contact angle measurements. Pre-coating of HA particles with pDA provided uniform and homogeneous anchoring of particles to PLLA surface. In addition, the strong ionic interaction between heparin and pDA led PLLA surface readily heparinized for loading of BMP-2. In vitro experiments revealed that the levels of alkaline phosphatase (ALP) activity, calcium deposition, and osteocalcin (OCN) gene expression were higher in MG-63 human osteosarcoma cell lines grown on PLLA/pDA/HA/Hep/BMP-2 than on control PLLA, PLLA/pDA/HA, and PLLA/pDA/Hep/BMP-2. In vivo studies using micro-computed tomography (micro-CT) also showed that PLLA/pDA/HA/Hep/BMP-2 screw exhibited greatest value of bone volume (BV) and bone volume/tissue volume (BV/TV) among samples. Histological evaluations with H&E and Von Kossa staining demonstrated that a combination of HA and BMP-2 contributed to the strong osseointegration.

Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT study

  • Emmanuel Joao Nogueira Leal da Silva;Sara Gomes de Moura;Carolina Oliveira de Lima;Ana Flavia Almeida Barbosa;Waleska Florentino Misael;Mariane Floriano Lopes Santos Lacerda;Luciana Moura Sassone
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the shaping ability of the TruShape and Reciproc Blue systems and the apical extrusion of debris after root canal instrumentation. The ProTaper Universal system was used as a reference for comparison. Materials and Methods: Thirty-three mandibular premolars with a single canal were scanned using micro-computed tomography and were matched into 3 groups (n = 11) according to the instrumentation system: TruShape, Reciproc Blue and ProTaper Universal. The teeth were accessed and mounted in an apparatus with agarose gel, which simulated apical resistance provided by the periapical tissue and enabled the collection of apically extruded debris. During root canal preparation, 2.5% sodium hypochlorite was used as an irrigant. The samples were scanned again after instrumentation. The percentage of unprepared area, removed dentin, and volume of apically extruded debris were analyzed. The data were analyzed using 1-way analysis of variance and the Tukey test for multiple comparisons at a 5% significance level. Results: No significant differences in the percentage of unprepared area were observed among the systems (p > 0.05). ProTaper Universal presented a higher percentage of dentin removal than the TruShape and Reciproc Blue systems (p < 0.05). The systems produced similar volumes of apically extruded debris (p > 0.05). Conclusions: All systems caused apically extruded debris, without any significant differences among them. TruShape, Reciproc Blue, and ProTaper Universal presented similar percentages of unprepared area after root canal instrumentation; however, ProTaper Universal was associated with higher dentin removal than the other systems.

LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY (미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구)

  • Lee, Hyeok-Sang;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.498-503
    • /
    • 2006
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements (highly-filled glass ionomer cement, compomer, resin-modified glass ionomer cement) and a resin composite(control). The long-term changes in remineralization caused by each material were evaluated by microtomography. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 for 30 days with constant circulation Tomographic images were obtained with a micro CT scanner at 90, 180, and 270 days, and density-measuring software was used to calculate the micro-density of artificial caries lesions in the specimens. The mean density changes were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using one-way ANOVA and the post-HOC Tukey multiple comparison test at p<0.05. While the density of artificial caries lesions increased for all treatments, the increases for the three glass ionomer groups were significantly higher than that for the resin group in each three month period. As time went on, the amount of density increase of the glass ionomer groups decreased, and significant differences were found between the remineralization effects of the glass ionomer groups.

  • PDF

플라즈마 필러처리를 통한 탄화목분 복합소재 전도도 향상

  • Lee, Heon-Su;Kim, U-Yeong;Park, Hyeong-Cheol;Hwang, Jun-Yeon;Kim, Seong-Ryun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.161.1-161.1
    • /
    • 2015
  • 복합소재는 두가지 이상의 서로 다른 물질을 조합하여, 단일 물질이 가질 수 없는 뛰어난 특성을 가진 소재로 그 중 전기 전도성 복합소재는 일반적으로 폴리머와 전도성 필러의 혼합을 통해 만들어 전자파 차폐, 대전 방지 등의 목적으로 사용되고 있다. 종류에 따라 기존 금속 소재에 비해 가볍거나 탄성율이 높은 등의 장점이 있으나 필러나 레진에 따라 재활용에 어려움이 있으며 전도성 필러로 주로 쓰이는 카본블랙 등이 석유/천연가스 등의 한정적 자원으로부터 만들어짐에 따라 환경적인 이슈가 최근 부각되고 있다. 목재는 가장 널리 쓰이는 소재 중 하나로 재생 가능하며 친환경적인 특성으로 인해 더욱 다양한 분야로의 활용이 모색되고 있다. 본 연구에서는 목재 소재의 탄화를 통해 만들어진 탄화목분의 전도성 필러로의 적용가능성을 시험하고자 CBT 레진과 탄화목분 필러의 복합소재를 제작하였다. 탄화 목분 복합소재의 전도성은 20 wt% 필러 함량 기준 카본블랙 복합소재 전도도에 20%에 이르렀으며, 전도도의 향상을 위해 필러의 플라즈마 처리 시 복합소재의 전도도가 급격히 향상되어, 카본 블랙 복합소재 전도도의 3배에 이르렀다. 플라즈마 처리가 탄화목분 복합소재의 전도도향상에 미치는 영향을 분석하기 위해 micro-CT, TGA 분석을 수행하였으며, 플라즈마 처리 시 탄화 목분 필러가 일부 미분화 되어 복합소재의 전도도를 향상하는 것으로 나타났다. 이와 같이 탄화 목분의 전도성 복합소재 적용과, 탄화목분의 플라즈마 처리를 통해 친환경적일 뿐만아니라 전도도도 우수한 복합소재를 구현하였으며, 실험적으로 전도도 향상 메커니즘을 확인하였다.

  • PDF

Comparative Evaluation of Fibrin for Bone Regeneration in Critical Size Calvarial Defects

  • Song, Gin-Ah;Kim, Soung Min;Woo, Kyung Mi
    • International Journal of Oral Biology
    • /
    • v.39 no.3
    • /
    • pp.153-157
    • /
    • 2014
  • Natural biopolymers such as collagen and fibrin have been widely used in bone regenerative applications. Despite the frequent use, their comparative biological propertiesis are largely unknown. In a previous study, we found the superiority of fibrin to collagen in the adsorption of serum proteins and the proliferation and differentiation of cultured osteoblasts. In this study, we used an in vivo model to evaluate how effectively fibrin supports bone regeneration, as compared with collagen. Collagen and fibrin were placed in critical size defects made on rat calvarial bones. Compared with collagen, fibrin supported substantially more new bone tissue formation, which was confirmed by micro-CT measurement and histological analyses. The cells in the regenerative tissues of the fibrin-filled defects were immunostained strongly for Runx2, while collagen-placed defects were stained weakly. These in vivo results demonstrate that fibrin is superior to collagen in supporting bone regeneration.

Thermal Fatigue Behavior of 3D-Woven SiC/SiC Composite with Porous Matrix for Transpiration Cooling Passages

  • Hayashi, Toshimitsu;Wakayama, Shuichi
    • Advanced Composite Materials
    • /
    • v.18 no.1
    • /
    • pp.61-75
    • /
    • 2009
  • The effect of porous matrix on thermal fatigue behavior of 3D-orthogonally woven SiC/SiC composite was evaluated in comparison with that having relatively dense matrix. The porous matrix yields open air passages through its thickness which can be utilized for transpiration cooling. On the other hand, the latter matrix is so dense that the air passages are sealed. A quantity of the matrix was varied by changing the number of repetition cycles of the polymer impregnation pyrolysis (PIP). Strength degradation of composites under thermal cycling conditions was evaluated by the $1200^{\circ}C$/RT thermal cycles with a combination of burner heating and air cooling for 200 cycles. It was found that the SiC/SiC composite with the porous matrix revealed little degradation in strength during the thermal cycles, while the other sample showed a 25% decrease in strength. Finally it was demonstrated that the porous structure in 3D-SiC/SiC composite improved the thermal fatigue durability.

Preparation and Characterization of Carbon/Phenol Composite by RTM Process (RTM 공정에 의한 탄소/페놀 복합재료의 제조 및 특성 분석)

  • Jin, Da Young;Lee, Hyun Jae;Lim, Sung Chan;Kim, Yun Chul;Yun, Nam Gyun;Lee, Seung Goo
    • Textile Coloration and Finishing
    • /
    • v.28 no.4
    • /
    • pp.239-245
    • /
    • 2016
  • In this study, carbon/phenol composites were prepared from carbon fiber preform and phenol resin by RTM(resin transfer molding) process. And changes in the properties of the composite according to the pre-treatment of phenol resin was mainly studied. RTM process conditions were deduced from viscosity and thermal analysis of phenol resin which were rheometer and thermogravimetric analyzer(TGA). RTM process was performed under various injection and molding temperature. Characterization of the prepared C/P composites were evaluated by various analysis. Morphology of composites was analyzed by Micro-CT(MCT), Mechanical properties of composites were measured through the flexural properties. As results, volatile impurities of phenol resin were effectively removed at resin pre-treatment temperature of $100^{\circ}C$ and composite was sufficiently cured at molding temperature of $180^{\circ}C$.

Characteristics of Sound Response in Ear Canal of Human and Reproduction of Acoustical Space (인간 이도의 소리응답특성과 음향공간의 재현)

  • Ahn, Tae-Soo;Lee, Doo-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.842-849
    • /
    • 2011
  • The human ear canal amplifies the sound pressure level at specific frequency bands. The characteristics of the ear canal are very similar to those of curved cylindrical tube. In this study, the characteristics of sound transfer in human ear canal were measured and the acoustical space of ear canal was reproduced from the canal cavity geometry. For the measurement of sound transfer function in ear canal, a probe microphone and a reference microphone were used. The sound transfer functions were measured for 5 human subjects. To reproduce the acoustical space of the ear canal, two kinds of ear simulator were designed. The first one is a straight cylindrical tube type and the other is a real-shape ear of which geometry was taken from a micro-CT scanning of a human ear. The characteristics of the reproduced apparatus were compared with those of the human and a commercial ear simulator, RA0045 of G.R.A.S. Inc. The comparison results show that the developed apparatus well represent the ear canal characteristics in the low frequency, but have limited coincidence in level over high frequency range.