• Title/Summary/Keyword: micro viscosity

Search Result 180, Processing Time 0.028 seconds

The development of biodegradable resin for scaffold fabrication using micro-stereolithography and curing characteristics analysis of the resin (마이크로 광 조형기술을 이용한 인공지지체의 제작을 위한 생분해성 수지의 개발 및 경화 특성 파악)

  • Lee J.W.;Cho D.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.147-148
    • /
    • 2006
  • A research on scaffold fabrication has been progressed in many research groups. However, the mechanical properties of existing biodegradable materials are still not satisfactory. But, PPF (poly (propylene fumarate)) has a good mechanical property in comparison to other biodegradable materials. Nevertheless, the viscosity of the synthesized PPF is too high to fabricate structures using micro-stereolithography. Therefore, the viscosity of the resin was made low by adding the diethyl fumarate and this material could be used in micro-stereolithography apparatus. Then, a photoinitiator was added for photo crosslinking of the DEF/PPF resin. 2.5D and 3D scaffolds were fabricated our system and curing characteristics of the resin were analyzed through the experiment.

  • PDF

Implementation of High Performance Micro Electrode Pattern Using High Viscosity Conductive Ink Patterning Technique (고점도 전도성 잉크 패터닝 기술을 이용한 고성능 미세전극 패턴 구현)

  • Ko, Jeong Beom;Kim, Hyung Chan;Dang, Hyun Woo;Yang, Young Jin;Choi, Kyung Hyun;Doh, Yang Hoi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.1
    • /
    • pp.83-90
    • /
    • 2014
  • EHD (electro-hydro-dynamics) patterning was performed under atmospheric pressure at room temperature in a single step. The drop diameter smaller than nozzle diameter and applied high viscosity conductive ink in EHD patterning method provide a clear advantage over the piezo and thermal inkjet printing techniques. The micro electrode pattern was printed by continuous EHD patterning method using 3-type control parameters (input voltage, patterning speed, nozzle pressure). High viscosity (1000cps) conductive ink with 75wt% of silver nanoparticles was used. EHD cone type nozzle having an internal diameter of $50{\mu}m$ was used for experimentation. EHD jetting mode by input voltage and applied 1st order linear regression in stable jet mode was analyzed. The stable jet was achieved at the amplitude of 1.4~1.8 kV. $10{\mu}m$ micro electrode pattern was created at optimized parameters (input voltage 1.6kV, patterning speed 25mm/sec and nozzle pressure -2.3kPa).

In-vitro study on the hemorheological characteristics of chicken blood in microcirculation

  • Ji, Ho-Seong;Lee, Jung-Yeop;Lee, Sang-Joon
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.89-95
    • /
    • 2007
  • The flow characteristics of chicken blood in a micro-tube with a $100{\mu}m$ diameter are investigated using a micro-Particle Image Velocimetry (PIV) technique. Chicken blood with 40% hematocrit is supplied into the micro-tube using a syringe pump. For comparison, the same experiments are repeated for human blood with 40% hematocrit. Chicken blood flow has a cell-free layer near the tube wall, and this layer's thickness increases with the increased flow speed due to radial migration. As a hemorheological feature, the aggregation index of chicken blood is about 50% less than that of human blood. Therefore, the non-Newtonian fluid features of chicken blood are not very remarkable compared with those of human blood. As the flow rate increases, the blunt velocity profile in the central region of the micro-tube sharpens, and the parabolicshaped shear stress distribution becomes to have a linear profile. The viscosity of both blood samples in a low shear rate condition is overestimated, while the viscosity in a high shear rate range is underestimated due to radial migration and the presence of a cell-depleted layer.

Micro Plishing using Electorheological fluid (ER유체를 이용한 미세 연마 가공)

  • 김욱배;이성재;박철우;이상조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.850-853
    • /
    • 2000
  • It is well-known that Electro-rheological(ER) fluid is a material(suspension) which shows the dramatic change of rheological properties under an electric field. Using these properties, the concept that variable apparent viscosity of ER fluid could be applicable to the polishing for micro parts was introduced. It was investigated that how it works for polishing and how it affects ER effect when abrasives were mixed with an ER fluid. Therefore a few structures for polishing using ER fluid was suggested and evaluated by means of experiments. In this paper, fundamental mechanism and experimental results are described.

  • PDF

An Experimental Study on Vaporization and Combustion Behavior for Single Droplets of Water-in-Oil Emulsified Fuels (유화연료 단일액적의 증발 및 연소거동에 관한 실험적 연구)

  • Park, M.C.;Kim, B.S.;Oh, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 2000
  • An experimental study has been carried on single fuel droplets of water-in-light oil emulsions in an electric furnace to elucidate the dominant factor for the occurrence of micro-explosions. The tests were carried out by changing the following four parameters; the surfactant, the ratio of water to light oil, ambient temperature in electric furnace, and four kinds of fuels having different viscosity(light-oil, kerosene, iso-octane, bunker fuel). The result shows that micro-explosion phenomena is dominated without surfactant and below 30% of water content. Explosion-time is affected by ambient temperature and viscosity of used fuel.

  • PDF

Evaluation of Shear Bond Strength and Microleakage of Bulk-fill Resin Composites (Bulk-fill 복합레진의 상아질 전단결합강도 및 미세누출)

  • Lee, Hanbyeol;Seo, Hyunwoo;Lee, Juhyun;Park, Howon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.4
    • /
    • pp.281-290
    • /
    • 2015
  • The aim of this study was to evaluate shear bond strength (SBS) of bulk-fill resin composites (RCs) to dentin and their micro-leakage. One high-viscosity bulk-fill RC and 2 low-viscosity bulk-fill RCs were compared with 1 conventional RC. 7thgenerationbondingagentswereused. In order to evaluate SBS values, 40 permanent molars were selected and divided into 4 groups. The bulk-fill RCs were applied in 4 mm thickness, whereas the conventional RC was applied in 2 mm thickness. In order to evaluate micro-leakage, class I cavities ($5{\times}2{\times}4mm$) were prepared in 32 permanent molars. The teeth were divided into 4 groups and restored with resin composites in an increment of 4 mm for the bulk-fill RC and in 2 horizontal increments of 2 mm for the conventional RC. The mean SBS value of conventional RC showed no statistically significant difference when compared with those of low-viscosity bulk-fill RCs. However, the mean SBS value of high-viscosity bulk-fill RC was significantly lower than that of conventional RC (p < 0.05). There were no statistically significant differences in micro-leakage between the 4 groups. For SBS and micro-leakage, the use of low-viscosity bulk-fill RCs might help clinicians simplify the procedure.

Development of Components in Micro Solid Propellant Thruster. (마이크로 고체 추진제 추력기의 요소 개발)

  • 이종광;이대훈;권세진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.147-150
    • /
    • 2003
  • The purpose of this research was to develope components of micro solid propellant thruster. Micro solid propellant thruster had four basic components: combustion chamber, nozzle, solid propellant and micro heater for ignition. A performance of micro heater and characteristic of solid propellant was investigated. Micro heater was fabricated by conventional MEMS process and Platinum layer was used for heating element. Effect of geometry parameters on micro heater was tested. The temperature responses of heater with respect to each parameters was compared for a given electrical power. The characteristic of solid propellant(HTPB/AP) was investigated to obtain burning velocity in small chamber. Additionally, a capacity of filling propellant with high viscosity in small chamber was checked to guarantee for the micro fabrication.

  • PDF

Characteristics of Micro-polishing using the Electro-rheological Fluid (ER유체를 이용만 마이크로 폴리싱 특성)

  • 이재종;이응숙;황경현;민승기
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.38-42
    • /
    • 2002
  • In the recent, electro-rheological fluid has been used for micro polishing of the 3-dimensional micro-aspherical lens and some sectional parts with defects on the wide flat wafer. The ER fluid has the properties that its viscosity has drastic changed under some electric fields. Therefore, ER fluid can be applicable to the micro polishing fur some parts using these properties. In this paper, the experimental device has been constructed using the precision milling machine in order to micro polishing far some sectional parts of a 4 inches wafer It is consisted of a small steel electrode, a wafer fixture, DC10mA and 5KV power supply unit, and a controller unit. Using the ER experimental device, possibility of amending for wide flat wafer and micro polishing of some micro part has been analyzed.

  • PDF

A Study of High Viscosity Phosphor Dispensing for an Electrostatic Printing System (전기수력학 프린팅 시스템을 이용한 고점도 형광체의 정량 토출 연구)

  • Kim, S.W.;Yang, Y.J.;Dang, H.W.;Yang, B.S.;Kim, H.B.;Choi, K.H.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.83-88
    • /
    • 2015
  • For chromaticity correction, it is necessary to dispense high viscosity phosphor slurry since it greatly affects the performance of white LEDs. However, it is quite difficult to dispense high viscosity fluorescent materials. In the current study, micro-discharge electrostatic printing has been used for dispensing various high viscosity phosphor slurries. We have achieved dispersions of up to 50 µg using drop on demand (DOD) discharge experiments. The experiments were conducted with different combinations of process variables such as applied voltage, pneumatic pressure, and frequency.

Characteristics of ERF Polishing using Chemical-oil (케미컬오일을 이용한 ERF 연마 특성)

  • 윤종호;이재종;이응숙;이동주;김영호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.27-33
    • /
    • 2004
  • Electro-theological fluid is recently used for the micro polishing of 3-dimensional micro-aspherical lens. It's also used for polishing small area defects on the wide flat wafer. Since ER fluid shows a behavior of viscosity changing under certain electric fields. micro polishing efficiency may be enhanced for certain cases. In this paper, a perfluorinated carbonyl fluoride oil based ER fluids was used to improve surface polishing rate and submicron-scale accuracy. As the polishing electrodes, micro size cylindrical tools had been used for maximizing the electric field. An experimental device, which was applied for micro polishing a number of wafers of 4inches in size and other workpiece. was made on a precision polishing system. It consisted of a steel electrode. a wafer fixture. l0㎃ current and DC 5㎸ power supply unit, and a controller unit. From the Experiments. the ER fluid is applicable for micro polishing of small parts.

  • PDF