• Title/Summary/Keyword: micro beam

검색결과 671건 처리시간 0.028초

Free vibration of sandwich micro-beam with porous foam core, GPL layers and piezo-magneto-electric facesheets via NSGT

  • Mohammadimehr, Mehdi;Firouzeh, Saeed;Pahlavanzadeh, Mahsa;Heidari, Yaser;Irani-Rahaghi, Mohsen
    • Computers and Concrete
    • /
    • 제26권1호
    • /
    • pp.75-94
    • /
    • 2020
  • The aim of this research is to investigate free vibration of a novel five layer Timoshenko microbeam which consists of a transversely flexible porous core made of Al-foam, two graphen platelets (GPL) nanocomposite reinforced layers to enhance the mechanical behavior of the structure as well as two piezo-magneto-electric face sheets layers. This microbeam is subjected to a thermal load and resting on Pasternak's foundation. To accomplish the analysis, constitutive equations of each layer are derived by means of nonlocal strain gradient theory (NSGT) to capture size dependent effects. Then, the Hamilton's principle is employed to obtain the equations of motion for five layer Timoshenko microbeam. They are subsequently solved analytically by applying Navier's method so that discretized governing equations are determined in form of dynamic matrix giving the possibility to gain the natural frequencies of the Timoshenko microbeam. Eventually, after a validation study, the numerical results are presented to study and discuss the influences of various parameters such as nonlocal parameter, strain gradient parameter, aspect ratio, porosity, various volume fraction and distributions of graphene platelets, temperature change and elastic foundation coefficients on natural frequencies of the sandwich microbeam.

Safety and Efficacy of Transluminal Balloon Angioplasty Using a Compliant Balloon for Severe Cerebral Vasospasm after an Aneurysmal Subarachnoid Hemorrhage

  • Choi, Beam-Jin;Lee, Tae-Hong;Lee, Jae-Il;Ko, Jun-Kyeung;Park, Hwa-Seung;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권3호
    • /
    • pp.157-162
    • /
    • 2011
  • Objective : Vasospasm of cerebral vessels remains a major source of morbidity and mortality after an aneurysmal subarachnoid hemorrhage (SAH). The purpose of this study was to evaluate the safety and efficacy of transluminal balloon angioplasty (TBA) for SAH-induced vasospasm. Methods : Eleven patients with an angiographically confirmed significant vasospasm (>50% vessel narrowing and clinical deterioration) were studied. A total of 54 vessel segments with significant vasospasm were treated by TBA. Digital subtraction angiography was used to confirm the presence of vasospasm, and TBA was performed to dilate vasospastic arteries. Medical and angiographic reports were reviewed to determine technical efficacy and for procedural complications. Results : TBA using Hyper-Glide or Hyper-Form balloons (MicroTherapeutics, Irvine, CA) was successfully accomplished in 88.9% vasospastic segments (48 of 54), namely, in the distal internal carotid artery (100%, n=7), the middle cerebral artery (100%), including the M1 (n=10), M2 (n=10), and M3 segments (n=4), in the vertebral artery (100%, n=2), basilar artery (100%, n=1), and in the anterior cerebral artery (ACA), including the A1 (66%), A2 (66%), and A3 segments (100%). Vessel diameters significantly increased after TBA. There were no cases of vessel rupture or thromboembolic complications. GCS at one day after TBA showed an improvement in all patients except one. Conclusion : This study suggests that TBA using Hyper-Glide or Hyper-Form balloons is a safe and effective treatment for subarachnoid hemorrhage-induced cerebral vasospasm.

Eutectic Temperature Effect on Au Thin Film for the Formation of Si Nanostructures by Hot Wire Chemical Vapor Deposition

  • Ji, Hyung Yong;Parida, Bhaskar;Park, Seungil;Kim, MyeongJun;Peck, Jong Hyeon;Kim, Keunjoo
    • Current Photovoltaic Research
    • /
    • 제1권1호
    • /
    • pp.63-68
    • /
    • 2013
  • We investigated the effects of Au eutectic reaction on Si thin film growth by hot wire chemical vapor deposition. Small SiC and Si nano-particles fabricated through a wet etching process were coated and biased at 50 V on micro-textured Si p-n junction solar cells. Au thin film of 10 nm and a Si thin film of 100 nm were then deposited by an electron beam evaporator and hot wire chemical vapor deposition, respectively. The Si and SiC nano-particles and the Au thin film were structurally embedded in Si thin films. However, the Au thin film grew and eventually protruded from the Si thin film in the form of Au silicide nano-balls. This is attributed to the low eutectic bonding temperature ($363^{\circ}C$) of Au with Si, and the process was performed with a substrate that was pre-heated at a temperature of $450^{\circ}C$ during HWCVD. The nano-balls and structures showed various formations depending on the deposited metals and Si surface. Furthermore, the samples of Au nano-balls showed low reflectance due to surface plasmon and quantum confinement effects in a spectra range of short wavelength spectra range.

기질레진 필러가 UTMA계 광중합형 복합레진의 파괴인성에 미친는 영향 (EFFECT OF RESIN AND FILLER TYPE ON THE FRACTURE TOUGHNESS OF UTMA-BASED LIGHT-CURED COMPOSITES)

  • 안연실;황수진;배태성;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.604-613
    • /
    • 1999
  • This study was performed to evaluate the effect of resin and filler type on the fracture toughness of light-activated composites. Experimental composites were prepared using urethane tetramethacrylate(UTMA) and bisphenol glycidylmethacrylate(Bis-GMA) monomers and five different types of silica fillers. Fracture toughness was measured by a single edge V-notched beam(SEVNB) method, which was discussed from ASTM E399-78. Rectangular bars of $2.5{\times}5{\times}26mm$ were prepared with experimental composites and a notch about 2.25mm deep was carved at the center of the long axis of the specimen using a dental diamond disk driven by a dental micro engine. The flexural test was carried out at a crosshead speed of 0.05mm/min and fracture surfaces were observed under scanning electron microscope. The results obtained were summarized as follows: 1. The fracture toughness values of UTMA-based composites were relatively higher than those of Bis-GMA-based composites. 2. The highest fracture toughness value was observed in the UTMA-based composite containing the $1.5{\mu}m$-spherical fillers. 3 Aging in the distilled water at $37^{\circ}C$ for 10 days showed the increase of fracture toughness, which was severer in the Bis-GMA-based composites than those of UTMA-based composites. 4. The AE amplitude occurring during the fracture toughness tests was the highest at the point of macroscopic fracture.

  • PDF

카본을 첨가한 LTCC 그린 시트에서 UV 레이저를 이용한 미세 홀 터짐 현상 제어 (Control of Explosion Behavior in Micro Hole Using UV Laser on LTCC Green Sheets Containing Carbon Particles)

  • 김시연;안익준;여동훈;신효순;윤호규
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.786-790
    • /
    • 2016
  • Hole explosion behaviors were observed during drilling fine holes with laser beam on the LTCC green bar of $320{\mu}m$ thick after lamination of green sheets prepared by tape casting of thick film process. The incidence of these hole explosions was inversely proportional to hole sizes. The incidence of hole explosion was 20 % number of hole with the size of $60{\mu}m$ exploded for the UV radiation, while the explosion did not appear for hole sizes over $100{\mu}m$. To prevent hole explosion behavior during laser-drilling of fine holes, carbon black powder was added as an additive in the LTCC composition, which has superior thermal durability. As a consequence, hole explosion rate was suppressed to 0.8 % for the hole size of $50{\mu}m$ green sheet with the carbon black amount of 10 weight % and the laser power of 3 watt. Added carbon is thought to reduce the heat-affected region during laser drilling.

고정밀 회전 및 축방향 이송을 위한 신개념 원통형 자기부상 스테이지 (Novel Cylindrical Magnetic Levitation Stage for Rotation as well as Translation along Axles with High Precisions)

  • 전정우;;이창린;정연호;김종문;오현석;김성신
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1828-1835
    • /
    • 2012
  • In this paper, a conceptual design and a detailed design of novel cylindrical magnetic levitation stage is introduced. This is came from planar-typed magnetic levitation stage. The proposed stage is composed of cylinder-typed permanent magnet array and semi-cylinder-typed 3 phase winding module. When a proper current is induced at winding module, a magnetic levitation force between the permanent magnet array and winding module is generated. The proposed stage can precisely move the cylinder to rotations and translations as well as levitations with the magnetic levitation force. This advantage is useful to make a nano patterning on the surface of cylindrical specimen by using electron beam lithography under vacuum. Two methods are used to calculate required magnetic levitation forces. The one is 2D FEM analysis, the other is mathematical modeling. This paper shown that results of two methods are similar. An assistant plate is introduced to reduce required currents of winding module for levitations in vacuum. The mathematical model of cylindrical magnetic levitation stage is used for dynamic simulation of magnetic levitations. A lead-lag compensator is used for control of the model. Simulation results shown that the detail designed model of the cylindrical magnetic levitation stage with the assistant plate can be controlled very well.

Digital PLL을 이용한 초음파진동 측정용 레이저 도플러 진동계의 개발 (The development of laser doppler vibrometer using DPLL for the detection of ultrasonic vibration)

  • 김호성
    • 한국광학회지
    • /
    • 제11권5호
    • /
    • pp.306-311
    • /
    • 2000
  • 본 논문에서는 초음파영역에서 진동하는 물체의 진동주파수와 크기를 측정할 수 있는 레이저 도플러 진동계(Laser Doppler Vibrometer, 이하 LDV)를 설계, 제작하였다. LDV의 광원으로는 파장이 632.8 nm인 He-Ne 레이저를 사용하였으며 Bragg셀에 의해 주파수가 천이되도록 한 마이켈슨형 간섭게 (Michelson interferometer)로 구성하였다. PIN다이오드의 출력은 중심주파수가 40 MHz인 주파수 변조된 신호이며, 이 신호를 증폭하고 주파수를 2.5MHz로 낮춘 후 디지털로 변환하였다. Digital Phase Locked Loop(이하 DPLL)를 사용하여 진동하는 표면의 속도에 비례하는 전압출력을 얻었으며, 이 신호로부터 진동주파수와 크기를 추출하고 주파수특성을 보상하기 위하여 마이크로프로세서를 사용하였다. 그 결과 300 kHz까지의 진동을 측정할 수 있었으며 300 kHz로 진동하는 경우 측정 가능한 최소진폭은 1 nm이었다. 본 연구에서 개발된 LDV는 대용량 전기기기의 부분방전에 의해 발생되는 초음파진동으로부터 최소형 전기 기기의 미세진동까지 측정하는 비접촉식 진동 측정에 사용할 수 있다고 사료된다.

  • PDF

나노임프린트를 이용한 바이오칩용 나노 패턴 제작 (Fabrication of Nanopatterns for Biochip by Nanoimprint Lithography)

  • 최호길;김순중;오병근;최정우
    • KSBB Journal
    • /
    • 제22권6호
    • /
    • pp.433-437
    • /
    • 2007
  • 본 연구에서는 나노임프린트 리소그래피를 이용하여 500 nm line, 600 nm pore, $1{\mu}m$ pore, $2.5{\mu}m$ pore의 마이크로 수준에서 나노 수준에 이르는 다양한 크기와 모양의 nanopore 형태 패턴을 제작하였다. Thermal imprint 방식과 달리 상온, 저압에서 임프린팅이 가능하며 사용되는 스탬프의 수명을 늘리고 보다 미세하고 복잡한 형태의 패턴을 제작할 수 있는 UV-assisted imprint 방식을 사용하였다. E-beam lithography로 패턴을 각인한 quartz소재의 스탬프를 사용하였으며 스탬프의 재질이 투명하여 UV 조사시 UV curable resin이 경화될 수 있도록 하였다. 또한 스탬프의 표면을 (heptadecafluoro-1,1,2,2-tetrahydrodecyl) trichlorosilane의 monolayer 층으로 미리 코팅하여 임프린트 후 스탬프와 기판과의 releasing을 쉽게함과 동시에 패턴의 일부가 스탬프에 묻어 나와 전사된 패턴에 defect가 없도록 하였다. 또한, gold를 미리 증착하여 임프린팅함으로써 lift-off 시에 필요한 hi-layer 층이 필요 없게 되어 산소 플라즈마를 이용한 에칭이 더욱 쉽고 lift-off 공정이 생략될 수 있도록 하였다. 나노임프린트 공정에 있어 가장 큰 문제점은 잔여층의 생성이며 이러한 잔여층을 제거하고자 산소 플라즈마 에칭을 하였다. 에칭공정을 통해 gold의 표면이 완전히 드러났으며 산소 플라즈마를 통해 gold의 표면이 친수성으로 바뀌어 추후 단백질 고정화를 더욱 쉽게 하였다. 그리하여 나노임프린트 기술을 이용해 나노크기의 바이오소자 제작을 가능하게 하였다.

Comparison of light-transmittance in dental tissues and dental composite restorations using incremental layering build-up with varying enamel resin layer thickness

  • Rocha Maia, Rodrigo;Oliveira, Dayane;D'Antonio, Tracy;Qian, Fang;Skif, Frederick
    • Restorative Dentistry and Endodontics
    • /
    • 제43권2호
    • /
    • pp.22.1-22.9
    • /
    • 2018
  • Objectives: To evaluate and compare light-transmittance in dental tissues and dental composite restorations using the incremental double-layer technique with varying layer thickness. Materials and Methods: B1-colored natural teeth slabs were compared to dental restoration build-ups with A2D and B1E-colored nanofilled, supra-nanofilled, microfilled, and microhybrid composites. The enamel layer varied from 0.3, 0.5, or 1.2 mm thick, and the dentin layer was varied to provide a standardized 3.7 mm overall sample thickness (n = 10). All increments were light-cured to $16J/cm^2$ with a multi-wave LED (Valo, Ultradent). Using a spectrophotometer, the samples were irradiated by an RGB laser beam. A voltmeter recorded the light output signal to calculate the light-transmittance through the specimens. The data were analyzed using 1-way analysis of variance followed by the post hoc Tukey's test (p = 0.05). Results: Mean light-transmittance observed at thicker final layers of enamel were significantly lower than those observed at thinner final layers. Within 1.2 mm final enamel resin layer (FERL) thickness, all composites were similar to the dental tissues, with exception of the nanofilled composite. However, within 0.5 mm FERL thickness, only the suprananofilled composite showed no difference from the dental tissues. Within 0.3 mm FERL thickness, none of the composites were similar to the dental tissues. Conclusions: The supra-nanofilled composite had the most similar light-transmittance pattern when compared to the natural teeth. However, for other composites, thicker FERL have a greater chance to match the light-transmittance of natural dental tissues.

Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서 (A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism)

  • 윤성식;이수현;안종혁;이종현
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.