• Title/Summary/Keyword: miR-30a

Search Result 426, Processing Time 0.041 seconds

The Effectiveness of Problem-Solving Treatment on Geriatric Depression (노인 우울증에 대한 문제해결치료(Problem-Solving Treatment)의 효과성 연구)

  • Yoon, Hyun-Sook;Koo, Bon-Mi;Lee, Kang;Lee, Jea-Yeon
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.871-894
    • /
    • 2010
  • Research was undertaken to examine the effectiveness of PST for the depression of Korean Elderly. The program and manual for korean elderly was developed based on PST procedures for depression as outlined by Nezu and D'Zurilla(2007). For the purpose, 150 old people over 65 who resided in chunchun were randomly selected. and screened with PHQ-9. 42 elderly who had depression symptom at middle level, were chosen for study and randomly assigned into experimental group(n=23) and control group(n=19). PST is a six session, manual-based conducted over an 6-week period by trained interviewers in the elderly's home. As a results, CES-D and KGDS of the experimental group have been significantly decreased and total SPSI-R has been significantly increased between pre-and post measures while no statically significant change was found in control group. This results suggest that problem-solving therapy program might decrease the depression and enhance the problem solving ability of the elderly and that PST can be suitable to home visit program with social work perspectives.

Development of a Measuring Tool for Spiritual Care Performance of Hospice Team Members (호스피스 팀원들의 영적 돌봄 수행도 측정 도구 개발)

  • Yoo, Yang-Sook;Han, Sung-Suk;Lee, Sun-Mi;Seo, Min-Jeong;Hong, Jin-Ui
    • Journal of Hospice and Palliative Care
    • /
    • v.9 no.2
    • /
    • pp.86-92
    • /
    • 2006
  • Purpose: This study was conducted to develop a measuring tool for spiritual care performance of hospice team members. The tool may be utilized for providing hospice patients with more systematic and standardized spiritual tares. Methods: The concept and questions of the tool were developed, and then its validity and reliability were tested. For the validity and reliability tests, a self-reported questionnaire comprising 33 questions with 4 point scale ($1{\sim}4$), was developed, and the data were collected from 192 hospice team members from December 2005 to February 2006. Results: Thirty three questions, drafted through literature review and professional consultation, were reviewed by 20 professionals for their validity, were revised and supplemented resulted in the final 33 questions. The questions with a correlation coefficient grater than .30 were selected: all the 33 questions were selected based on this criterion. The reliability coefficient, Cronbarh's ${\alpha}$, was 0.95. The 33 questions were analyzed for factors, and six factors were extracted: relationship formation and communication, encouragement and promotion of spiritual growth, linking with spiritual resources, preparation of death, evaluation and quality control for spiritual intervention, Intervention, and spiritual assessment for intervention. Conclusion: The tool developed in this study includes six factors and has high level of reliability. This tool Will greatly contribute to assess and improve hospice care services, providing systematic and standardized spiritual cares for terminally ill patients and their families.

  • PDF

Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests (TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가)

  • Park, Hye-Mi;Yoo, Seon-Hee;Lee, Seon-Ho;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

Physicochemical Characteristics and Antioxidant Activities of Doragi (Platycodon grandiflorum) at Different Aging Temperatures and for Various Durations (숙성온도와 기간에 따른 도라지의 이화학적 특성과 항산화 활성)

  • Lee, Sang Hoon;Song, Eun Mi;Jang, Gwi Yeong;Li, Meishan;Kim, Min Young;Park, Hye Jin;Kang, Tae Su;Jeong, Heon Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.9
    • /
    • pp.1405-1411
    • /
    • 2013
  • We investigated the physicochemical characteristics and antioxidant activities of Doragi (Platycodon grandiflorum) at different aging temperatures (60, 70 and $80^{\circ}C$) and for various periods of duration (5, 10, 15, 30 and 50 days). As the temperature and duration were increased, the pH of Doragi water extracts decreased from 5.22 to 4.17, whereas total acidity increased from 0.265 to 0.998 lactic acid eq.%. In addition, browning index went up from 0.092 to 1.002 and 5-hydroxymethylfurfural (HMF) content steeply rose to 50.40 mg/g from its initial zero value with an increase in temperature and duration. The radical scavenging activity of ethanol extracts was enhanced with a rise in temperature and duration as evident from the value of total polyphenol content (0.589 to 2.358 mg/g), DPPH (0.149 to 1.244 mg Trolox eq/g) and ABTS (0.354 to 1.509 mg Trolox eq/g). The correlation between physicochemical characteristics and antioxidant activities was high; the correlation between pH and total acidity showed a r value of -0.910 (P<0.01), whereas between browning index and 5-HMF content, the r value was 0.880 (P<0.01). Total polyphenol content and DPPH and ABTS radical scavenging activity were highly correlated with the r value of 0.885 (P<0.01) and 0.745 (P<0.01), respectively.

Combustion Characteristic Study of LNG Flame in an Oxygen Enriched Environment (산소부화 조건에 따른 LNG 연소특성 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Lee, Dae-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • The ultimate objective of this study is to develop oxygen-enriched combustion techniques applicable to the system of practical industrial boiler. To this end the combustion characteristics of lab-scale LNG combustor were investigated as a first step using the method of numerical simulation by analyzing the flame characteristics and pollutant emission behaviour as a function of oxygen enrichment level. Several useful conclusions could be drawn based on this study. First of all, the increase of oxygen enrichment level instead of air caused long and thin flame called laminar flame feature. This was in good agreement with experimental results appeared in open literature and explained by the effect of the decrease of turbulent mixing due to the decrease of absolute amount of oxidizer flow rate by the absence of the nitrogen species. Further, as expected, oxygen enrichment increased the flame temperatures to a significant level together with concentrations of $CO_2$ and $H_2O$ species because of the elimination of the heat sink and dilution effects by the presence of $N_2$ inert gas. However, the increased flame temperature with $O_2$ enriched air showed the high possibility of the generation of thermal $NO_x$ if nitrogen species were present. In order to remedy the problem caused by the oxygen-enriched combustion, the appropriate amount of recirculation $CO_2$ gas was desirable to enhance the turbulent mixing and thereby flame stability and further optimum determination of operational conditions were necessary. For example, the adjustment of burner with swirl angle of $30\sim45^{\circ}$ increased the combustion efficiency of LNG fuel and simultaneously dropped the $NO_x$ formation.

The effect of local rifampicin instillation on the treatment of suppurative BCG lymphadenitis (BCG 접종에 따른 화농성 림프절염의 rifampicin 국소투여 효과)

  • Kim, Min Son;Jo, Dae Sun;Kang, Mi Kyung;Kim, Sang Jae;Kim, Jung Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.40-45
    • /
    • 2006
  • Purpose : The purpose of this study was to evaluate the types of lymphadenitis after BCG vaccination and the effect of local rifampicin instillation on the treatment of suppurative BCG lymphadenitis. Methods : A total of 32 otherwise healthy infants with suppurative BCG lymphadenitis, who visited the Department of Pediatrics of Chonbuk National University Hospital, from March 2002 through June 2004, were enrolled in this study. They were treated with needle aspiration and local rifampicin instillation. We investigated the time the lymphadenitis took to be suppurative, accompanying clinical manifestations, and the treatment effects. Results : Of the 32 infants, 19 were male and 13 were female. They were full term babies and one preterm baby with a gestational age of 30 weeks. They received intradermal administration, with the BCG vaccine of $Pasteur^{(R)}$(French) strain mostly on the left deltoid area(96.9 percent). Regional lymphadenitis occurred in 1 to 11 months after BCG vaccination, mostly 1-5 months after vaccination (78.1 percent). Among the infants, 87.5 percent had unilocular lesion but 12.5 percent had more than one enlarged lymph node cares. Most of the lymphadenitis presented in the left axillary area(77.8 percent), and the left supuraclavicular area(11.1 percent). After one to three times of needle aspiration with rifampin instillation, all infants recovered completely without surgical excision or severe complication. Conclusion : The regional lymphadenitis is the most common complication in infants who receive intradermal BCG vaccination. This study supports that in suppurative BCG lymphadenitis the needle aspiration and local rifampicin instillation is very effective and can be a more economical treatment modality.

MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA (상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정)

  • Her, Mi-Ja;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

Effect of Cultivars and Cooking Methods on the Trypsin Inhibitor Activities of Potatoes

  • Kim, Mi-Yeon;Son, Chan-Wok;Shim, Hyun-Jung;Lee, Jeung-Hee;Lee, Kun-Jong;Sok, Dai-Eun;Kim, Hyoung-Chin;Yoon, Won-Kee;Kim, Hwan-Mook;Kim, Mee-Ree
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.161-165
    • /
    • 2008
  • The trypsin inhibitor activities (TIA) of various potato cultivars were evaluated by measuring the inhibition of trypsin inhibitor activity using N-benzoyl-DL-arginine-p-nitroanilide (BAPNA) as substrate. The TIA values of 5 potato cultivars (1.99 to 2.88 mg/g) were significantly different among cultivars (p<0.05). When the TIA values of commercially processed potatoes were determined, no TIA was detected. During cooking, the $IT_{50}$ (time required to reach 50% inhibition of TIA) values were decreased as heating temperature and time increased. The ITso of moist heating was estimated to be 0.34 min at $100^{\circ}C$, whereas for deep-fat frying the $IT_{50}$ was 0.13 min at $180^{\circ}C$ and 5.28 min for oven baking at $100^{\circ}C$. The $IT_{50}$ value of microwave cooking was 0.194 min at medium heat, and which was similar to that of pressure cooking at $120^{\circ}C$ (0.185 min). Moreover, there was a negative relationship between temperature (${\geq}80^{\circ}C$) and $IT_{50}$ values ($R^2=0.99$, p<0.01). The TIA of potato was completely inactivated by moist heating at $100^{\circ}C$ within 5 min, whereas the pressure cooking at $120^{\circ}C$ and deep-fat frying at $180^{\circ}C$ within 60 and 30 sec, respectively. Based on our results, deep-fat frying is the most effective cooking method to reduce TIA in potatoes.

Fermentation and Quality Characteristics of Cheonggukjang Fermented with Bacillus subtilis BC-P1 (Bacillus subtilis BC-P1 균주를 이용하여 제조한 청국장의 발효 및 품질 특성분석)

  • Park, Sung-Yong;Bang, Mi-Ae;Oh, Boung-Jun;Park, Jeong-Hoon;Song, Won-Seob;Choi, Kyung-Min;Choung, Eui-Su;Boo, Hee-Ock;Cho, Seung-Sik
    • Korean Journal of Microbiology
    • /
    • v.49 no.3
    • /
    • pp.262-269
    • /
    • 2013
  • The object of this study was to improve the quality of Cheonggukjang with new starter, Bacillus subtilis BC-P1. Twenty strains were isolated from the commercial cheonggukjang and 1 Bacillus strain (BC-P1) with protease activity was selected. The 16S rRNA gene sequence revealed that the BC-P1 was closely related to B. subtilis with 99% homology. The quality characteristics of chunggukjang fermented with B. subtilis BC-P1, Bacillus nato (PC) and commercial chunggukjang (NC) were investigated. The characteristics of fermentation were determined by protease, lipase, xylanase, chitinase, and fibrinolytic activities, reducing sugar, nutrient composition and amino acid contents of cheonggukjang sample. Cheonggukjang fermented with B. subtilis BC-P1 showed the strongest fibrinolytic, xylanase, and chitinase activities. Reducung sugar contents of Cheonggukjang samples were $30.16{\pm}2.11$ mg/g (NC), $28.56{\pm}1.52$ mg/g (PC), $32.39{\pm}1.87$ mg/g (BC-P1). And their total amino acid contents were 338.99 mg% (NC), 445.19 mg% (PC), 741.35 mg% (BC-P1). These results suggested that B. subtilis BC-P1 was suitable to be used as a starter to enhance the quality and effects of cheonggukjang.

Assessment of correlation between markers of ambient monitoring and biological monitoring of dimethylformamide for workers in synthetic leather manufacturing factories in Korea (국내 합성피혁제조업 근로자에 대한 디메틸포름아미드의 공기중 농도와 생물학적 노출지표간의 상관성 평가)

  • Hwang, Yang In;Lee, Mi-Young;Chung, Yun Kyung;Kim, Eun A
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.315-325
    • /
    • 2013
  • The possibility of acute hepatotoxicity caused by dimethylformamide (DMF) requires regular monitoring of the workers who are using DMF to prevent the occupational disease. The authors performed ambient and biological monitoring of workers involved in synthetic leather manufacturing processes using DMF to assess the correlation between the markers of ambient and biological monitoring of DMF. The authors monitored 142 workers occupationally exposed to DMF from 19 workshops in the synthetic leather and ink manufacturing industries located in northern region of Gyeonggi-do. The subjects answered questionnaire on work procedure and use of personal protective equipment to be classified by exposure type. DMF in air samples collected using personal air samplers, diffusive and active sampler, was analysed using gas chromatograph-flame ionization detector (GC-FID) with DB-FFAP column (length 30 m, i.d. 0.25 mm, film thickness 0.25 ${\mu}m$). Urinary N-methylformamide (NMF) was analysed using gas chromatograph-mass selective detector (GC-MSD) at selected ion monitoring (SIM) mode with DB-624 column (length 60 m, i.d. 0.25 mm, film thickness 1.40 ${\mu}m$). Geometric mean (GM) and geometric standard deviation (GSD) of the ambient DMF was $6.85{\pm}3.43$ ppm, and GM and GSD of urinary NMF was $42.3{\pm}2.7$ mg/L. The ratio of subjects with DMF level over 10 ppm was 44%, and those with urinary NMF over 15 mg/L was 87%. NMF in urine adjusted by DMF in air was $4.61{\pm}2.57$ mg/L/ppm and $9.50{\pm}2.41$ mg/L/ppm, respectively, with or without respirator. There was seasonal differences of NMF in urine adjusted by DMF in air, $7.63{\pm}2.74$ mg/L/ppm in summer and $4.53{\pm}2.29$ mg/L/ppm in winter. The urinary NMF concentration which corresponds to 10 ppm of ambient DMF was 52.7 mg/L (r=0.650, n=128). Considering the difference of the route of exposure which resulted from the compliance of wearing personal protective equipment, the estimated contribution of respiratory and dermal exposure route for DMF was 48.5% vs. 51.5%.