• Title/Summary/Keyword: methods%3A inversion

Search Result 115, Processing Time 0.033 seconds

PSYCHIATRIC CHARACTERISTICS OF CHILD PATIENTS WITH INVERSION OF CHROMOSOME 9 - A PRELIMINARY STUDY - (9번 염색체 전위를 지닌 환아들의 정신과적 특성 - 예비적 연구 -)

  • Lee, Jun-Young;Hwang, Jun-Won;Hong, Kang-E;Kim, Jae-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.1
    • /
    • pp.71-78
    • /
    • 2001
  • Objectives:Few studies have examined the psychiatric properties or child developmental problems associated with inversion of chromosome 9. The purpose of this study is to examine the psychiatric properties of child patients who have inversion of chromosome 9, focused on behavioral problems and child developmental problems like motor or language developmental delay, intellectual impairment, and growth retardation. Methods:1) The authors examined the cases referred for cytogenetic examination from 1984 to 2000 at Seoul National University Hospital in Korea. The cases with the examination result of inversion of chromosome 9 were collected and informations about the departments which referred and the main reasons for referral were also checked. 2) 12 child subjects with inversion of chromosome 9 and their parents underwent psychiatric interview and parent questionnaire(child and adolescent past history questionnare, CBCL). 45 normal students whose sex and age were matched to patients were selected as a control group. Results:1) There were 165 cases of inversion of chromosome 9. The major departments which referred were Obstetrics and Gynecology(47.3%), Pediatrics(23.6%) and Child and Adolescent Psychiatry(17.0%). The major reasons for referral from the Pediatrics and the Child and Adolescent Psychiatry department (67 cases total) were intellectual impairment(35.8%), language or motor developmental delay(31.3%), suspected Fragile X syndrome(23.9%), and growth retardation(20.9%). 2) Compared to normal control group, the rate to be included in the clinical range with regard to the social problems profile was higher in patient group according to the CBCL results. The patient group had language and motor developmental delay. Conclusion:There is a possibility of inversion of chromosome 9 to be associated with child developmental problems or behavioral problems. This study is the first approach to evaluate the developmental aspects associated with inversion of chromosome 9.

  • PDF

Maximising the lateral resolution of near-surface seismic refraction methods (천부 탄성파 굴절법 자료의 수평 분해능 최대화 연구)

  • Palmer, Derecke
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.85-98
    • /
    • 2009
  • The tau-p inversion algorithm is widely employed to generate starting models with most computer programs, which implement refraction tomography. This algorithm emphasises the vertical resolution of many layers, and as a result, it frequently fails to detect even large lateral variations in seismic velocities, such as the decreases which are indicative of shear zones. This study demonstrates the failure of the tau-p inversion algorithm to detect or define a major shear zone which is 50m or 10 stations wide. Furthermore, the majority of refraction tomography programs parameterise the seismic velocities within each layer with vertical velocity gradients. By contrast, the Generalized Reciprocal Method (GRM) inversion algorithms emphasise the lateral resolution of individual layers. This study demonstrates the successful detection and definition of the 50m wide shear zone with the GRM inversion algorithms. The existence of the shear zone is confirmed by a 2D analysis of the head wave amplitudes and by numerous closely spaced orthogonal seismic profiles carried out as part of a later 3D refraction investigation. Furthermore, an analysis of the shot record amplitudes indicates that a reversal in the seismic velocities, rather than vertical velocity gradients, occurs in the weathered layers. The major conclusion reached in this study is that while all seismic refraction operations should aim to provide as accurate depth estimates as is practical, those which emphasise the lateral resolution of individual layers generate more useful results for geotechnical and environmental applications. The advantages of the improved lateral resolution are obtained with 2D traverses in which the structural features can be recognised from the magnitudes of the variations in the seismic velocities. Furthermore, the spatial patterns obtained with 3D investigations facilitate the recognition of structural features such as faults which do not display any intrinsic variation or 'signature' in seismic velocities.

Inversion of Geophysical Data via Simulated Annealing (아닐링법에 의한 지구물리자료의 역산)

  • Kim, Hee Joon
    • Economic and Environmental Geology
    • /
    • v.28 no.3
    • /
    • pp.305-309
    • /
    • 1995
  • There is a deep and useful connection between thermodynamics (the behavior of systems with many degrees of freedom in thermal equilibrium at a finite temperature) and combinational or continuous optimization (finding the minimum of a given multiparameter function). At the heart of the method of simulated annealing is an analogy with the way that liquids freeze and crystallize, or metals cool and anneal. This paper provides a detailed description of simulated annealing. Although computationaly intensive, when it is carefully implemented, simulated annealing is found to give superior results to more traditional methods of nonlinear optimization.

  • PDF

Tillage Operational Analysis Based on Soil Moisture Content, Machine Speed, and Disc Space of Compact Disc Harrow

  • Okyere, Frank Gyan;Moon, Byeong Eun;Qasim, Waqas;Basak, Jayanta Kumar;Kahn, Fawad;Kang, Dae Sik;Yoon, Yong Cheol;Kim, Hyeon Tae
    • Journal of Biosystems Engineering
    • /
    • v.43 no.3
    • /
    • pp.161-172
    • /
    • 2018
  • Purpose: During tillage operations, the selection of a working machine (tool) depends on the soil conditions as well as the type of tillage operation to be performed. The goal of this research was to ascertain the effects of varying working machine parameters of a compact disc harrow on tillage operations under various soil moisture content (SMC) conditions. Methods: The working machine parameters were the disc spacing and machine speed. The tillage parameters under investigation were the soil inversion ratio (SIR), tillage cutting depth (TCD), and soil clod breakage ratio (SCB). To determine the SIR, the areas of the white regions before and after tillage were obtained. The ratio of the difference of the areas of the white regions before and after tillage to the area of the white regions before tillage was considered as the SIR. The SCB was obtained as the ratio of the weight of soil clods after sieving with a mesh size of <0.02 m to the total weight of the soil clods before sieving. The soil TCD was measured using a tape measure at random points after the tillage operation. The resulting data were statistically analyzed in a one-way analysis of variance. Results: The highest soil inversion was achieved when the machine speed was 0.2 m/s with the disc spaced at 0.2 m in the 16.5% SMC. At a 0.4-m/s machine speed and 0.3-m disc spacing the highest soil breakage was achieved in the 26.5% SMC. The highest TCD was achieved at a 0.2-m/s machine speed and 0.2-m disc spacing in the 16.5% SMC. Conclusions: It was concluded that varying the working machine parameters, such as the disc spacing and machine speed, could significantly affect the soil inversion and soil clod breakage; however, it had no significant impact on the TCD.

Efficient Masking Methods Appropriate for the Block Ciphers ARIA and AES

  • Kim, Hee-Seok;Kim, Tae-Hyun;Han, Dong-Guk;Hong, Seok-Hie
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.370-379
    • /
    • 2010
  • In this paper, we propose efficient masking methods for ARIA and AES. In general, a masked S-box (MS) block can be constructed in different ways depending on the implementation platform, such as hardware and software. However, the other components of ARIA and AES have less impact on the implementation cost. We first propose an efficient masking structure by minimizing the number of mask corrections under the assumption that we have an MS block. Second, to make a secure and efficient MS block for ARIA and AES, we propose novel methods to solve the table size problem for the MS block in a software implementation and to reduce the cost of a masked inversion which is the main part of the MS block in the hardware implementation.

Comparison of Tillage and Loads Characteristics of Three Types of Rotavators: Rotary-type, Crank-type, and Plow-type

  • Kim, Myoung-Ho;Nam, Ju-Seok;Kim, Dae-Cheol
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.73-80
    • /
    • 2013
  • Purpose: This study was conducted to compare tillage and loads characteristics of three types of rotavators in farmland working condition of Korea. Methods: Tillage operations using three types of rotavators, i.e. rotary-type, crank-type and plow-type, were carried out in a dry field of Korea. The same prime mover tractor was used for driving three types of rotavators, and under several operational conditions, tillage characteristics such as actual working speed, rotavating depth, rotavating width, actual field capacity, flow of tilled soil, soil inversion ratio, and pulverizing ratio were measured. In addition, loads characteristics like torque and required power of Power Take-Off (PTO) shaft were calculated. Results: The average rotavating depth was smaller than the nominal value for all rotavators, and the difference was the greatest in the plow-type rotavator. Nevertheless, the plow-type rotavator showed the largest rotavating depth. The rotavating width was the same as the nominal value of all rotavators. The flow of tilled soil at the same operational conditions was the greatest in the plow-type rotavator and was the smallest in the rotary-type rotavator. In the most commonly used gear conditions of L2 and L3, the average soil pulverizing ratio was the greatest in the rotary-type rotavator, and followed by crank-type and plow-type rotavators in order. In the gear L2 and L3, the plow-type rotavator also had the lowest average soil inversion ratio while the rotary-type and crank-type rotavators had the same soil inversion ratio each other. The average torque and power of PTO shaft in the gear L2 and L3 were the highest in the plow-type rotavator. The load spectra of PTO shaft applying rain flow counting method and Smith-Waston-Topper equation to the measured torque showed that the modified torque amplitude was the greatest in the crank-type rotavator. This may come from the large torque fluctuation of crank-type rotavator during tillage operations. Conclusions: The three types of rotavators had different tillage and loads characteristics. The plow-type rotavator had the deepest rotavating depth, the smallest soil inversion ratio, the largest soil pulverizing ratio and required PTO power. Also, the crank-type rotavator showed a large torque fluctuation because of their unique operational mechanism. This study will help the farmers choose a suitable type of rotavator for effective tillage operations.

Comparison of Tibialis Anterior Muscle Thickness with 4 Different Toe and Ankle Postures: Ultrasonographic Study

  • Jang, Tae-Jin;Hwang, Byeong-Hun;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.1
    • /
    • pp.12-17
    • /
    • 2022
  • Purpose: Ankle dorsiflexion is an essential element of normal functions, including walking, activities of daily living and sport activities. The tibialis anterior (TA) muscle functioned as a dorsiflexor and as a dynamic stabilizer of the ankle joint during walking and jumping. This study aimed to compare TA muscle thickness using ultrasonography according to the four different toe and ankle postures for the selective TA strengthening exercise. Methods: This study were recruited 26 (males: 15, females: 11) aged 20-30 years, with no injury ankle and calf in the medical history, had normal dorsiflexion and inversion range of motion (ROM). The thickness of the TA muscle was measured by ultrasonography in the four different toe and ankle postures: 1. Ankle dorsiflexion with all toe extension and ankle inversion (ITEDF); 2. Ankle dorsiflexion with all toe flexion and ankle inversion (ITFDF); 3. Ankle dorsiflexion with all toe extension and neutral position (NTEDF); 4. Ankle dorsiflexion with all toe flexion and neutral position (NTFDF). One-way repeated analysis of variance (ANOVA) and Bonferroni correction were used to confirm the significant difference among conditions. The level of statistical significance was set at α=0.01. Results: TA muscle thickness with ITFDF was significantly greater than in any other ankle positions, including ITEDF, NTFDF, and NTEDF (p<0.01). Conclusion: Among the four toe and ankle postures, isometric contraction in ITFDF postures showed the greatest increase in thickness of TA rather than ITEDF, NTEDF, and NTFDF postures. Based on these results, ITFDF can be recommended in an efficient way to selectively strengthen TA muscle.

The Effects of Vibration Exercise after Modified Bröstrom Operation in Soccer Players with Ankle Instability

  • Kim, Sanghoon;Kim, Yangrae;Kim, Yongyoun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.2
    • /
    • pp.1791-1796
    • /
    • 2019
  • Background: Vibration exercise after ankle surgery improves proprioception and ankle muscle strength through vibration stimulation. Objective: To examine the effects of vibration exercise on the ankle stability. Design: Randomized controlled clinical trial (single blind) Methods: Twenty soccer players were randomly divided into experimental group and control group. The Vibration exercise program was conducted 12 weeks and 3 times a week. Ankle joint proprioceptive sensory test and Isokinetic muscle strength test were performed using Biodex system pro III to measure plantar flexion / dorsiflexion and eversion / inversion motion. Results: The result of isokinetic test of ankle joint is showed significant improvement in all measurement items, such as leg flexion, lateral flexion, external and internal muscle forces, compared to previous ones by performing vibration movements for 12 weeks. However, in the comparison group, plantar flexor ($30^{\circ}$), eversion muscle ($120^{\circ}$), inversion ($30^{\circ}$) of limb muscle strength were significantly improved compared with the previous phase; was no significant difference in dorsi-flexion. There was no significant difference between groups in all the items. Conclusions: In this study, we analyzed the effects of rehabilitation exercise on soccer players who had reconstructed with an ankle joint ligament injury through vibration exercise device. As a result, we could propose an effective exercise method to improve the ability, and confirmed the applicability as an appropriate exercise program to prevent ankle injuries and help quick return.

The Role of Double Inversion Recovery Imaging in Acute Ischemic Stroke

  • Choi, Na Young;Park, Soonchan;Lee, Chung Min;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.210-219
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate if double inversion recovery (DIR) imaging can have a role in the evaluation of brain ischemia, compared with diffusion-weighted imaging (DWI) and fluid-attenuated inversion recovery (FLAIR) imaging. Materials and Methods: Sixty-seven patients within 48 hours of onset, underwent MRI scans with FLAIR, DWI with b-value of 0 (B0) and $1000s/mm^2$, and DIR sequences. Patients were categorized into four groups: within three hours, three to six hours, six to 24 hours, and 24 to 48 hours after onset. Lesion-to-normal ratio (LNR) value was calculated and compared among all sequences within each group, by the Friedman test and conducted among all groups, for each sequence by the Kruskal-Wallis test. In qualitative assessment, signal intensity changes of DIR, B0, and FLAIR based on similarity with DWI and image quality of each sequence, were graded on a 3-point scale, respectively. Scores for detectability of lesions were compared by the McNemar's test. Results: LNR values from DWI were higher than DIR, but not statistically significant in all groups (P > 0.05). LNR values of DIR were significantly higher than FLAIR within 24 hours of onset (P < 0.05). LNR values were significantly different between, before, and after six hours onset time for DIR (P = 0.016), B0 (P = 0.008), and FLAIR (P = 0.018) but not for DWI (P = 0.051). Qualitative analysis demonstrated that detectability of DIR was higher, compared to that of FLAIR within 4.5 hours and six hours of onset (P < 0.05). Also, the DWI quality score was lower than that of DIR, particularly relative to infratentorial lesions. Conclusion: DIR provides higher detectability of hyperacute brain ischemia than B0 and FLAIR, and does not suffer from susceptibility artifact, unlike DWI. So, DIR can be used to replace evaluation of the FLAIR-DWI mismatch.

Assessment of Diffusion-Weighted Imaging-FLAIR Mismatch: Comparison between Conventional FLAIR versus Shorter-Repetition-Time FLAIR at 3T

  • Goh, Byeong Ho;Kim, Eung Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.88-94
    • /
    • 2016
  • Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter-TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, $0.9{\times}0.9mm$) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWI-matched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; $1.25{\pm}0.20$; $1.24{\pm}0.20$, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.