• Title/Summary/Keyword: metal reduction

검색결과 1,699건 처리시간 0.03초

In situ monitoring-based feature extraction for metal additive manufacturing products warpage prediction

  • Lee, Jungeon;Baek, Adrian M. Chung;Kim, Namhun;Kwon, Daeil
    • Smart Structures and Systems
    • /
    • 제29권6호
    • /
    • pp.767-775
    • /
    • 2022
  • Metal additive manufacturing (AM), also known as metal three-dimensional (3D) printing, produces 3D metal products by repeatedly adding and solidifying metal materials layer by layer. During the metal AM process, products experience repeated local melting and cooling using a laser or electron beam, resulting in product defects, such as warpage, cracks, and internal pores. Such defects adversely affect the final product. This paper proposes the in situ monitoring-based warpage prediction of metal AM products with experimental feature extraction. The temperature profile of the metal AM substrate during the process was experimentally collected. Time-domain features were extracted from the temperature profile, and their relationships to the warpage mechanism were investigated. The standard deviation showed a significant linear correlation with warpage. The findings from this study are expected to contribute to optimizing process parameters for metal AM warpage reduction.

Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가 (Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT)

  • 손상준;박장필;김민정;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.107-114
    • /
    • 2014
  • 목 적 : 두경부 치료계획 CT영상에서 dental implant로 인한 metal artifact 발생 시 O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands)를 적용할 수 있을지 여부를 평가하고자 한다. 대상 및 방법 : 모든 CT영상은 Brilliance Big Bore CT(Philips, Netherlands)에서 관전압 120kVp, 2mm 두께로 촬영하였으며, O-MAR를 이용하여 Metal artifact reduction 후 전산화치료계획장비(Eclipse ver 10.0.42, Varian, USA)로 원본영상과 비교, 분석하였다. O-MAR의 기본적인 성능 테스트를 위해 Metal artifact가 발생하지 않은 영상과 발생한 영상에서 O-MAR 적용시, HU 변화를 검증하기 위해 원통형 팬텀과 cerrobend 막대, 불균질 팬텀을 이용하여 실험하였다. 각각의 원본 영상과 O-MAR 적용 영상에서 관심영역 내 HU 변화를 측정하였다. 이를 바탕으로 본 연구의 주목적인 dental implant로 인한 metal artifact 발생 영상을 재현하기 위해 팬텀을 제작하여 사용하였고, 실제 임상 환자 영상에 O-MAR를 적용한 영상과 원본 영상 그리고 artifact 부분을 보정한 영상의 선량 분포를 SNC Patient(Sun Nuclear Co., USA)로 비교하였다. 결 과 : 두경부에서의 metal artifact를 재현한 원본 영상과 O-MAR 적용영상의 선량 분포를 비교한 결과 gamma passing rate 는 2 mm / 2% 기준으로 99.8%, 일치를 보였다. 실제 임상 환자 영상을 바탕으로 O-MAR 적용 전후 영상과 density corrected CT 영상에 동일한 조건으로 치료 계획을 수립하여 선량 분포를 비교한 결과는 98.5% 일치로 비교적 높은 gamma passing rate를 보였다. 전체적인 선량 분포 차이는 모두 2% 이내로 팬텀 실험과 실제 임상 환자 영상 실험에서 비슷한 결과로 나타났다. 하지만 선량 편차가 적더라도 국소적으로 집중되어 있는 것은 문제의 소지가 될 가능성이 있다. 화질 개선 면에서는 모든 실험에서 O-MAR 적용영상이 원본에 비해 개선됨을 알 수 있었으나, 두경부 metal artifact를 재현한 팬텀 영상 air cavity 내에서 최대 HU 값이 상승하는 경우가 생겼고, 환자 영상에서는 air cavity가 tissue로 잘못 보정되는 경우 또한 발견할 수 있었다. 결 론 : 업체에서 제시한 사용제한 사항인 피부 근처와 저밀도 영역이 공존하는 두경부에서 O-MAR의 사용 가능성을 확인해 본 결과, 원본의 왜곡과 보정이 동시에 일어났다. 심지어 팬텀 실험보다 더 심한 artifact가 생긴 환자의 경우 air cavity가 tissue로 잘못 보정되는 경우도 발생하였다. 결과적으로 아직까지는 O-MAR 알고리즘이 air cavity와 photon starvation artifact를 정확히 구분하지 못하는 것으로 보인다. 선량 측면에서의 영향은 임상에서 배제될 만큼 큰 차이를 보이지는 않았다. 임상에서 원본과 O-MAR 적용 영상을 비교하며 작업한다면 contouring, artifact 보정작업, DRR 화질 개선 등에 도움을 받을 수 있을 것으로 사료된다.

Theoretical Investigation of Edge-modified Zigzag Graphene Nanoribbons by Scandium Metal with Pyridine-like Defects: A Potential Hydrogen Storage Material

  • Mananghaya, Michael
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.253-256
    • /
    • 2014
  • Functionalization of zigzag graphene nanoribbon (ZGNR) segment containing 120 C atoms with pyridine (3NV-ZGNR) defects was investigated on the basis of density-functional theory (DFT) calculations, results show that edge-modified ZGNRs by Sc can adsorb multiple hydrogen molecules in a quasi-molecular fashion, thereby can be a potential candidate for hydrogen storage. The stability of Sc functionalization is dictated by a strong binding energy, suggesting a reduction of clustering of metal atoms over the metal-decorated ZGNR.

전해환원공정 관련 후처리공정 - 금속전환체 Smelting 및 용융염 고화 (Post Process Associated with the Electrochemical Reduction Process - Smelting of a Metal Product and Solidification of a Molten Salt)

  • 허진목;정명수;이원경;조수행;서중석;박성원
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.278-284
    • /
    • 2004
  • 전해환원공정에서 발생하는 금속전환체와 용융염을 각각 smelting하고 고화시키는 공정을 개발하였다. 진공조건에서 다단계 가열에 의하여 마그네시아 용기에 담긴 금속전환체를 잔류 용융염과 분리하고 용융시켜 금속 잉곳을 제조하는 운전방법을 제시하는 한편, 금속전환체의 분석을 수행하였다. 전해환원 공정에서 감압이송된 용융염의 경우에는 이송과 계량에 적합하게 이중 용기와 염밸브를 사용하여 일정 형상과 크기로 고화하는 신개념을 도출하였다. 본 연구의 결과는 한국원자력연구소 Advanced Spent Fuel Conditioning Process의 hot cell 실증시스템 설계에 적용되었다.

  • PDF

循環走査법에 의한 廢水로부터 亞鉛 回收에 관한 基礎 硏究 (Basic Studies on the Recovery of Zinc Metal from Wastewater by Cyclic Voltammetry)

  • 김진화;김동수
    • 자원리싸이클링
    • /
    • 제10권3호
    • /
    • pp.29-36
    • /
    • 2001
  • 전기화학적 환원 반응을 이용하는 전기 분해에 의한 방법으로 중금속 폐수를 처리하여 금속성분을 회수하는데 있어 cyclic voltammetry를 적용하였다. 아연용액에서의 아연전극과 탄소전극에 대한 전기적 반응 특성은 voltammogram으로 확인할 수 있었으며 수중 아연이온 환원은 전위가 -0.76V 이하에서 반응이 일어나는 것을 알 수 있었다. 용액 중 아연이온의 산화와 환원으로 인해 형성되는 금속 특성은 X선 회절분석 결과를 통해서 확인할 수 있었으며, AFM 이용하여 구리판에 환원된 아연을 관찰할 수 있었다. 본 연구의 결과는 전기분해에 의한 폐수 중 중금속의 처리 및 회수에 있어 기초자료로 활용죌 수 있을 것으로 사료된다.

  • PDF

The Direct Recycling of Electric Arc Furnace Stainless Steelmaking Dust

  • Zhang, Chuanfu;Peng, Bing;Peng, Ji;Lobel, Jonathan;Kozinski, Janusz A.
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.404-408
    • /
    • 2001
  • This paper focuses on the pilot-scale investigation of direct recycling of electric arc furnace (EAF) stainless steelmaking dust. The direct recycling of EAF dust is to make pellets with the mixture of the dust and the reducing agent carbon, then introduce the pellets to the EAF. The valuable metals in the dust are reduced and get into the steel as the alloying elements. Experiments simulating direct recycling in an EAF were performed using an induction furnace. But it seems difficult to reduce all metal oxides in the dust so that some metal reducing agents added in the late stage of reduction process. The valuable metals in the dust were reduced partly by carbon and partly by metal reducing agent for the economical concern. The recovery of iron, chromium and nickel from the flue dust and the amount of metal oxides in the slag were measured. The results showed that the direct recycling of EAF stainless steelmaking dust is practicable. It wes also found that direct recycling of flue EAF stainless steelmaking dusts does not affect the chemistry and quality of stainless steel produced in the EAF. It is benefit not only for the environmental protection but also for the recovery of valuable metal resources in this way.

  • PDF

열화학 수소 제조를 위한 금속 치환 페라이트 매체의 부분 환원 및 물 분해 특성 (Partial Reduction and Water Splitting Characteristics of Metal Substituted Ferrite Mediums for Thermochemical Hydrogen Production)

  • 이동희;김홍순;차광서;박주식;강경수;김영호
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.356-364
    • /
    • 2007
  • The partial reduction and water splitting properties of metal substituted ferrite mediums for two-step thermochemical hydrogen production, were carried out by TPR/O(Temperature programmed reduction/oxidation) method at a temperature of below 1173 K and under atmospheric pressure. $ZrO_2$ was added to the ferrite as a binder to prevent the sintering. As the results, the reactivity of the metal species added to the ferrite mediums decreased in the order of Cu>Co>Ni>Mn, on the basis of water-splitting temperature. It was also found that the produced hydrogen amounts in the water-splitting step on partial reduced mediums were corresponding to the consumed hydrogen amounts in the previously partial reduction step.

금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구 (A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN)

  • 윤종욱;양재호;장익태;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

전기로제강분진으로부터 환원휘발된 조산화아연의 침출용액 정액에 관한 연구 (Purification on the Leaching Solution of the Crude Zinc Oxide Recovered from the Reduction of EAF Dust)

  • 윤기병
    • 자원리싸이클링
    • /
    • 제13권1호
    • /
    • pp.22-27
    • /
    • 2004
  • 전기로제강분진을 환원휘발시켜 얻은 조산화아연을 염화암모늄용액으로 침출, 전해채취하여 99.9%(3-Nine) 이상의 고순도금속아연을 회수하기 위하여 침출용액 중의 Pb 및 Cd 불순원소이온들의 석출, 제거에 관한 기초실험을 수행하였다. Pb 및 Cd 이온 등의 석출, 제거는 금속아연분말의 첨가에 의한 cementation 반응을 이용하였으며, 정제된 용액을 전해액으로 사용한 전해채취실험을 수행하여 정액 중의 Pb 및 Cd 이온농도가 회수되는 금속아연 중의 Pb 및 Cd 함량에 미치는 영향을 분석하여 3N 이상의 고순도금 속아연 회수를 위한 정액조건을 조사, 검토하였다. Pb 및 Cd 이온농도가 각각 2ppm 및 0.1 ppm 이하인 정액을 전해액으로 사용할 때 3N 이상의 고순도금속아연을 회수할 수 있었으며, 이때 침출용액의 정액에 필요한 금속아연분말 첨가량은 8.5g/l 이상으로 조사되었다. 또한 정액과정에서 금속아연분말 첨가 시 용액의 Eh 변화를 측정하여 Eh 변화에 의한 금속아연분말첨가량의 제어가능성을 검토하였다.

열병합발전소 적용을 위한 Metal foam SCR촉매의 공간속도와 바인더 함량에 따른 NOx 저감에 관한 연구 (A Study on the NOx Reduction According to the Space Velocity Variation and Binder Content of Metal foam SCR Catalyst for Cogeneration Power Plant Application)

  • 나우진;박해경
    • 한국응용과학기술학회지
    • /
    • 제36권1호
    • /
    • pp.153-164
    • /
    • 2019
  • 본 연구에서는 기존 상용 SCR 촉매보다 비표면적, 경량성 및 온도 응답성이 우수한 SCR 촉매의 개발을 목적으로 바나듐과 텅스텐의 함량과 바인더의 첨가량을 달리하여 Metal foam 형태의 지지체에 코팅하여 SCR 촉매를 제조한 후, 실험실 규모의 마이크로 상압반응기상에서 공간속도별로 NOx 저감 성능을 측정하였다. 촉매의 특성은 Porosimeter, SEM(scanning electron microscope), EDX(energy dispersive x-ray spectrometer) 및 ICP(inductively coupled plasma), 실체현미경(Stereomicroscope) 기기를 이용하여 분석하였다. 연구 결과 NOx 저감 성능은 공간속도가 증가할수록 감소하였고, 바나듐과 텅스텐의 함량이 3.5 wt.% 일 때 가장 우수한 것으로 확인하였다. 또한, 바인더 첨가량이 많을수록 NOx 저감 성능이 감소하는 것으로 나타났는데, 이는 촉매 표면상의 활성점 수가 바인더에 의해 점유되어 감소된 것에 따른 것으로 판단된다. 또한 표면 코팅 상태 분석을 통하여 바인더의 첨가량이 적절히 조절 되어야 함을 알 수 있었다.