• Title/Summary/Keyword: metal bridge

Search Result 195, Processing Time 0.023 seconds

Descriptive study on the procedure of dental prostheses at the dental laboratory in Seoul (치과기공소의 보철 기공물 제작 과정에 사용되는 재료 및 방법에 관한 실태조사 연구)

  • Hwang, Kyung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.16 no.1
    • /
    • pp.57-77
    • /
    • 1994
  • The purpose of this study is to investigate the extent to which dental laboratories use proper materials, procedures, devices, and equipments to fabricate crown & bridge, PFM(Porcelain Fused to Metal) crown & bridge, partial denture, complete denture, and other prosteses. 100 laboratories in Seoul were selected for this investigation. Questionnaires were constructed focusing on five topocs:crown & bridge, PFM crown & bridge, partial denture, complete denture, and other prostheses. The results from this survey were as follows : 1. Most dental laboratories used old, inexpensive, and familiar materials rather than newly developed ones. 2. Most of the dental technicians did not stick to the standard procedures of handling materials, but to their own experiences. 3. Newly developed equipments to fabricate dental prostheses were possessed by nearly 30% dental laboratories. 4. About 80% of dental laboratories were using the procedures they had learned in the school : die trimming for accurate crown margin and softening heat treatment after RPD gold casting. But less than 30% of laboratories were shown to follow the boxing procedure to produce master cast and laboratory remounting in the process of complete denture. The findings show that dental laboratory procedures to fabricate dental prostheses are incomplete and inaccurate in some instances. So, further studies are neededs to clarify the causes of some inaccurate procedures, the better and more equipments should be supplied to produce the more accurate dental posthesis, and more efforts at enancing the appropriate use of dental materials and procedures should be made.

  • PDF

Dissolution Phenomenon in BaO-B2O3-ZnO Glass System by Acid Etching (산 에칭에 의한 BaO-B2O3-ZnO계 유리조성물의 용출 현상)

  • Kim, Jae-Myung;Hong, Kyung-Jun;Kim, Nam-Suk;Kim, Hyung-Sun
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.1 s.284
    • /
    • pp.33-37
    • /
    • 2006
  • For producing the fine ribs structure of plasma display panel, the metal ions of barrier materials during the etching process should be understood on the etching mechanism with etching conditions. Etching was done on bulk glasses of the $BaO_B_2O_3-ZnO$ system with $HNO_3$ solution at $40^{\circ}C$. The surface structure of glasses and ion dissolution were analyzed by ICP (Inductive Coupled Plasma measurement). The structure and surface of the etched bulk glass were investigated by using scanning electron microscopy and nanoindenter. As a result, Ba (3-35 ppm/min) and Zn (2-27 ppm/min) ions as major components were leached in the solution and the leached layers were found to be phosphor-rich surface layers. A decrease of the bridge oxygen and relative increase of non bridge oxygen in the etched glass were found by X-ray photoelectron spectroscopy.

Resin-bonded fixed partial denture using In-Ceram and Targis-Vectris system: A clinical report

  • Cha, Young-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.375-381
    • /
    • 2000
  • The conventional approach for replacing missing maxillary lateral incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM)bridge, resin-bonded fixed partial denture, or single implant prosthesis. However, several appearance-related disadvantages have been reported in the use of a prosthesis which incorporates a metal substructure. To address these limitations, metal -free restorative alternatives have been recently developed to expand the clinical options when fabrication of these prostheses is indicated. This clinical report describes the treatment of patients with a missing maxillary lateral incisor where the dentition was non-invasively restored with resin-bonded fixed partial denture(RBFPD) using In-Ceram and Targis-Vectris system.

  • PDF

Pollution Characteristics and Application of River Sediment of the Western Nakdong River (서낙동강의 오염 특성과 오염 퇴적물의 활용 방안)

  • 박흥재;유수진;이봉헌;정징운;안호기;박원우
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.51-55
    • /
    • 2001
  • The pollution characteristics of water quality analysis and the heavy metal analysis of river sediment in the Western Nakdong river, and then a commercial tile using the polluted sediment was produced. The analytical results of the riverbed structure and the depth distribution in the Western Nakdong river were that Macdo Stream(site 2) was the deepest(13 ft). The analytical result of water quality showed that BOD was the highest in the Hogei Stream(site 6); COD, Syanduengchi Island(site 1);SS, Macdo Stream(site 2);T-N, Suanduengchi Island(site 1);T-P, Macdo Stream(site 2). Therefore the deeper the site was the higher the pollution concentration was. The result of heavy metal analysis of the river sediment was that Pb and Cr were the highest in Kangdong Bridge(site 9); Cd, Macdo Stream(site 2), so the deeper the site was the higher the pollution concentration was. The production of tile using the mixure of the polluted sediment and the raw material was successful, so the reuse of polluted sediment was possible.

  • PDF

Fabrication of low power NO micro gas senor by using CMOS compatible process (CMOS공정 기반의 저전력 NO 마이크로가스센서의 제작)

  • Shin, Han-Jae;Song, Kap-Duk;Lee, Hong-Jin;Hong, Young-Ho;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • Low power bridge type micro gas sensors were fabricated by micro machining technology with TMAH (Tetra Methyl Ammonium Hydroxide) solution. The sensing devices with different heater materials such as metal and poly-silicon were obtained using CMOS (Complementary Metal Oxide Semiconductor) compatible process. The tellurium films as a sensing layer were deposited on the micro machined substrate using shadow silicon mask. The low power micro gas sensors showed high sensitivity to NO with high speed. The pure tellurium film used micro gas sensor showed good sensitivity than transition metal (Pt, Ti) used tellurium film.

Fabrication of Metal Thin-Film Pressure Sensor and Its Characteristics (금속박막형 압력세서의 제작과 그 특성)

  • 정귀상;최성규;남효덕;이원재;송재성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.5
    • /
    • pp.405-409
    • /
    • 2001
  • This paper describes fabrication and characteristics of metal thin-film pressure sensor for working at high temperature. The proposed pressure consists of a chrom thin-film, patterned on a Wheat stone bridge configuration, sputter-deposited onto thermally oxidized Si membranes with an aluminium interconnection layer. The fabricated pressure sensor presents a low temperature coefficient of resistance, high-sensitivity, low non-linearity and excellent temperature stability. The sensitivity is 1.097∼1.21mV/V$.$kgf/$\textrm{cm}^2$ in the temperature range of 25∼200$^{\circ}C$ and the maximum non-linearity is 0.43%FS.

  • PDF

COMPARATIVE STUDY ON THE CASTABILITY OF VARIOUS ALLOYS FOR PORCELAIN-FUSED-TO-METAL CROWN (도재소부전장주조관(陶材燒付前裝鑄造冠)에 사용(使用)되는 각종(各種) 합금(合金)의 주조성(鑄造性)에 관(關)한 비교연구(比較硏究))

  • Lee, Tae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.87-97
    • /
    • 1980
  • To compare the castability of various alloys popularly used in Korea for porcelain-fused-to-metal restorations, author selected Degudent G as precious alloy, J.P. 92 as semiprecious alloy and Vera Bond, Rexillium III, Unit Bond, Fine Bond as non precious alloys. With nylon lines and gauge waxes, author made the wax patterns for the castability comparison test. In the same conditions, wax patterns were invested, burned out and cast. Author obtained the following results from this study. 1. The castability of Degudent G as precious alloy for porcelain-fused-to-metal crown and bridge was the best of all. 2. The castability of nonprecious alloys was less than Degudent G as precious alloy, but their differences were not large. 3. The castability of Rexillium III is the best of all nonprecious alloys and that of Vera Bond, Unit Bond had nearly the same results. 4. Semiprecious alloy (J.P. 92) was less castable than nonprecious alloys.

  • PDF

A Study on the Life Expectancy of the Dental Prosthetic Restorations (치과보철물의 평균수명에 관한 연구)

  • Young-Ku Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.317-325
    • /
    • 1995
  • This study was performed to investigate the mean life expectancy of dental prosthetic restorations. The author has examined 352 dental prosthesis clinically and radiologically, and decided the success(survival) and failure(mortality) of the dental prosthesis. The dental prosthesis which had been treated in the Seoul National University Dental Hospital, two private clinics in Seoul, one university dental hospital, and two private clinics in local province were included in this study. The survival analysis using product limit estimator was used and the mean life expectancy of each type of dental prosthesis was calculated. The results were as follows : 1. The life expectancies were 10.5 years in gold crown and bridge, 8.5 years in porcelain fused to metal crown and bridge, 8.3 years in nonprecious metal crown and bridge, 8.1 years in removal partial denture, and 7.7 years in full denture. 2. The causes of mortality were in the order of dental caries(24.6%), fracture of dental prosthesis(19.2%), periodontal problems(18.6%), chronic chewing difficulty and dysfunction due to dental prosthesis(15.0%), excessive exposure of abutments due to the marginal defect of dental prosthesis(14.4%), abnormal occlusion due to severe attrition of artificial teeth in dentures(3.0%), periapical problems(2.4%), perforation of dental prosthesis(1.8%), and loose contacts with neighboring tooth(1.2%). 3. Among survival cases, 66.5% showed normal chewing ability and 31.9% showed partial chewing ability. However, 1.6% of them complained loss of chewing ability. 4. Among failure cases, 6.6% showed normal chewing ability and 38.9% showed partial chewing ability. However, 54.5% of them complained loss of chewing ability.

  • PDF

Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study

  • Bilhan, Selda Arat;Geckili, Onur;Cilingir, Altug;Bozdag, Ergun;Bilhan, Hakan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.4
    • /
    • pp.199-206
    • /
    • 2019
  • Objectives: In mandibular edentulism, the treatment option with a two-interforaminal implant-retained bridge and a removable partial denture is rarely evaluated in literature. The aim of this in vitro study was to evaluate the stress distribution of this treatment option by comparing it with traditional treatment options with interforaminal implants in the edentulous mandible. Materials and Methods: Two interforaminal implants were placed in a formalin-fixed cadaver mandible, and overdentures with three different types of attachments were fabricated: (1) two ball attachments and an overdenture, (2) a Dolder bar and an overdenture, and (3) screw-retained two-implant inter-canine porcelain fused to a metal bridge and an implant-assisted removable denture (IARD) with precision attachments. Three biting conditions were generated for each denture type, and the strains were documented under vertical loading of 100 N. Results: The calculated strain values from measured strains in all measurement sites and loading conditions for the screw-retained two-implant intercanine porcelain fused to a metal bridge and a cast framework partial denture with precision attachments situation were lower than in the other scenarios (P<0.05). Conclusion: Within the limitations of the present study, it can be concluded that an IARD may be a reasonable and valuable alternative to ball attachments or a bar in two interforaminal implants, especially when the patients prefer to be able to show their teeth even when they take out their removable dentures.

Fracture Resistance of Low Invasive Fixed Partial Dentures (수종 저 침습 고정성 국소의치의 수직하중에 대한 저항)

  • Choi, Jong-In;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.241-251
    • /
    • 2010
  • This study aims at contributing to the restorative dentistry by examining results in the vertical load test of four different low invasive fixed partial dentures. Based on a hypothesis on the right upper first molar is missing, three units of FPDs were made for the second premolar and the second molar abutment. that is, twelve metal dies and FPDs were made for resin bonded FPD and Two Key Bridges and Human Bridge without occlusal rest and Human Bridge with occlusal rest. By using universal test machine, the numerical maximum value were recorded during the vertical load test of each FPDs after the bonding process treated by Maxcem which is resin cement. The failure process and its result of prosthesis were also observed. The maximum load was 7,295 N, 4,729 N, 2,190 N, 3,073 N from groups of resin bonded FPD, Two Key Bridge, Human Bridge without occlusal rest and Human Bridge with occlusal rest respectively. There was a statistical significance among the groups of resin bonded FPD, Two Key Bridge and Human Brides. However, there was no significant difference between Human Bridge without occlusal rest and Human Bridge with occlusal rest. Regarding the failure of prosthesis, the groups of Resin Bonded FPD and Two Key Bridge showed that one of the abutment teeth in the both side of retention part was highly failed earlier than the other one (83.2% and 66.6% respectively). While, Human Bridge without occlusal rest and Human Bridge with occlusal rest showed high percentage of failure in the abutment teeth in the both side of retention part at the same time (91.6% and 58.3% respectively). This study demonstrates that the group of Human Bridges has low resistance to the vertical loads of low invasive FPDs in comparison with the groups of resin bonded FPD and Two Key Bridge. Nevertheless, the maximum occlusal load of the restorative position, resistance to diverse restoration failure, amount of tooth reduction and patients' cooperation should be considered when they are applied in the clinic in order to choose an appropriate restoration for each patient.